VII. CELOSTÁTNÍ
STUDENTSKÁ KONFERENCE
OPTOMETRIE A ORTOPTIKY
S MEZINÁRODNÍ ÚČASTÍ
SBORNÍK PŘEDNÁŠEK A POSTERŮ
20. 10. 2016
FSS MU
Joštova 10, 602 00 Brno
7. CELOSTÁTNÍ STUDENTSKÁ KONFERENCE OPTOMETRIE A ORTOPTIKY
s mezinárodní účastí
20. 10. 2016
Posluchárna P31
Fakulta sociálních studií Masarykovy univerzity
Joštova 10, 602 00 Brno
Pořadatelé sborníku
Mgr. Pavel Beneš, Ph.D.1
; Mgr. Sylvie Petrová1
;
Doc. MUDr. Svatopluk Synek, CSc.1
; Mgr. Petr Veselý, DiS., Ph.D.1
;
Bc. Marie Kodetová1
; Bc. Zuzana Odvárková; Bc. Jolana Nedvědová1
Generální sponzor
7TH
NATIONAL STUDENT CONFERENCE OF OPTOMETRY AND
ORTHOPTICS
with international participation
20. 10. 2016
Auditorium P31
Faculty of Social Studies, Masaryk University
Joštova 10, 602 00 Brno
Organizers
Mgr. Pavel Beneš, Ph.D.1
; Mgr. Sylvie Petrová1
;
Doc. MUDr. Svatopluk Synek, CSc.1
; Mgr. Petr Veselý, DiS., Ph.D.1
;
Bc. Marie Kodetová1
; Bc. Zuzana Odvárková1
; Bc. Jolana Nedvědová1
General sponsor
1
Katedra optometrie a ortoptiky, LF MU Brno, Pekařská 53, 656 91 Brno.
Obsah
Sekce prezentací
FAKTORY OVLIVŇUJÍCÍ ZDRAVÉ A POHODLNÉ POUŽÍVÁNÍ KONTAKTNÍCH ČOČEK................................. 1
FACTORS INFLUENCING HEALTHY AND COMFORTABLE WEARING OF CONTACT LENSES.......................... 6
BC. TOMÁŠ DOBŘENSKÝ
ROZDÍLY V HODNOTĚ DIOPTRICKÉHO NÁLEZU U DĚTÍ V ZÁVISLOSTI NA POUŽITÍ CYKLOPLEGIE.......... 10
DIFFERENCES IN REFRACTION OF CHILDREN WITH AND WITHOUT CYCLOPLEGIA.................................. 14
BC. KAROLÍNA FOJTLOVÁ
MGR. ANDREA JEŘÁBKOVÁ
VÝTĚŽNOST VYUŽITÍ PENTACAMU PŘI DIAGNOSTICE KERATOKONU................................................... 18
THE USE OF PENTACAM IN THE DIAGNOSIS OF KERATOCONUS............................................................. 22
BC. IVO HLINOMAZ
MGR. ONDŘEJ VLASÁK
STATICKÁ VERSUS DYNAMICKÁ ZRAKOVÁ OSTROST ........................................................................... 26
STATIC VERSUS DYNAMIC VISUAL ACUITY............................................................................................. 29
BC. PAVLA HRABALOVÁ
MGR. SIMONA BRAMBOROVÁ, DIS.
ZMĚNY AKOMODAČNĚ VERGENČNÍCH VLASTNOSTÍ V ZÁVISLOSTI NA VĚKU....................................... 32
AGE-RELATED CHANGES OF ACCOMMODATIVE VERGENT ATTRIBUTES................................................. 35
BC. MARKÉTA HRABOVSKÁ
MGR. DAVID SEVERA
INDIKACE K OPERACI ŠEDÉHO ZÁKALU................................................................................................ 39
INDICATION FOR CATARACT SURGERY.................................................................................................. 43
BC. PETRA JANOUŠKOVÁ
MGR. MATĚJ SKRBEK
OČNÍ PROTÉZY..................................................................................................................................... 47
OCULAR PROSTHESES........................................................................................................................... 54
BC. LUCIE KLUSOŇOVÁ
MGR. SYLVIE PETROVÁ
ADAPTACE NA TMU V ZÁVISLOSTI NA VĚKU........................................................................................ 61
DARK ADAPTATION DEPENDING ON AGE.............................................................................................. 68
BC. VERONIKA KRCHŇÁKOVÁ
MGR. PAVEL KŘÍŽ
THE CORNEA, SCLERA AND CONJUNCTIVA TARSAL – GRADATION DEGREES........................................ 75
SARA LONČAR, DOROTEA PRGUDA
SNÁŠENLIVOST VERTIKÁLNÍHO PRIZMATU.......................................................................................... 81
THE TOLERANCE OF VERTICAL PRISM ................................................................................................... 88
BC. JOLANA NEDVĚDOVÁ
MGR. MATĚJ SKRBEK
BAREVNÉ FOLIE A DYSLEXIE................................................................................................................. 95
COLOUR OVERLAYS AND DYSLEXIA..................................................................................................... 100
BC. ZUZANA ODVÁRKOVÁ
MGR. PETR VESELÝ, DIS., PH.D.
SROVNÁNÍ METOD MĚŘENÍ A VALIDITA HODNOT POTŘEBNÝCH PRO PŘESNÝ ZÁBRUS BRÝLOVÝCH
ČOČEK................................................................................................................................................ 105
COMPARISON OF MEASUREMENT METHODS AND NECESSARY VALIDITY VALUES FOR ACCURATE LENS
GRINDING.......................................................................................................................................... 110
MGR. LUCIE PATOČKOVÁ
MGR. PAVEL BENEŠ, PH.D.
IRISREGISTRACE................................................................................................................................. 115
IRIS REGISTRATION............................................................................................................................. 118
BC. HANA ŠTOLZOVÁ
MGR. ONDŘEJ VLASÁK
Sekce posterů
THE RELATIONSHIP BETWEEN MYOPIA AND CORNEAL ASTIGMATISM IN STUDENTS OF OPTOMETRY
IN CROATIA ....................................................................................................................................... 122
JOSIPA BAGARIĆ, MATIJA DUBOVSKI
URČENÍ POLOHY TORICKÝCH INTRAOKULÁRNÍCH ČOČEK ZA POUŽITÍ NAVIGAČNÍHO SYSTÉMU........ 125
DETERMINING THE POSITION OF TORIC IOLS USING A NAVIGATION SYSTEM...................................... 134
BC. MARTIN FŮS
DOC. MUDR. ŠÁRKA PITROVÁ, CSC., FEBO
INTERNETOVÝ A SAMOOBSLUŽNÝ PRODEJ – NOVÝ FENOMÉN V OBORU OPTIKA A OPTOMETRIE,
VÝHODY A RIZIKA PRO KLIENTA......................................................................................................... 141
INTERNET SALES AND SELF-SERVICE - A NEW PHENOMENON IN THE FIELD OF OPTICS AND OPTOMETRY,
BENEFITS AND RISKS FOR THE CLIENT................................................................................................. 145
BC. MICHAELA GAGOVÁ
MGR. PETR VESELÝ, DIS., PH.D.
PŘÍSTROJE POTŘEBNÉ PRO VYŠETŘENÍ ZRAKOVÉHO NERVU PŘI DIAGNOSTICE GLAUKOMU,
METODIKA VYŠETŘENÍ....................................................................................................................... 149
DEVICES NEEDED FOR EXAMINATION OF THE OPTIC NERVE HEAD IN GLAUCOMA DIAGNOSTICS,
METHODOLOGY OF EXAMINATION .................................................................................................... 153
BC. ZUZANA GERBOCOVÁ
MUDR. MAGDALÉNA MACUROVÁ
METODIKA STANOVENÍ HODNOTY OPTIMÁLNÍ AKOMODAČNÍ ŠÍŘE, OVĚŘENÍ ZÁVISLOSTI
NAMĚŘENÝCH HODNOT NA PRACOVNÍ VZDÁLENOSTI...................................................................... 157
METHODOLOGY OF SETTING THE OPTIMAL ACCOMMODATION AMPLITUDE, THE VERIFICATION OF
MEASURED VALUES DEPENDING ON WORKING DISTANCE.................................................................. 162
BC. ANDREA HANUŠOVÁ
MGR. RADEK ANDERLE, PH.D.
DODRŽOVÁNÍ HYGIENY A NÁVYKY NOSITELŮ MĚKKÝCH KONTAKTNÍCH ČOČEK................……………….168
COMPLIANCE AND HYGIENE BEHAVIOUR AMONG SOFT CONTACT LENS WEARERS............................. 173
BC. BARBORA HRÁČKOVÁ, BC. MARIE KODETOVÁ
MGR. PAVEL BENEŠ, PH.D.
ZMĚNA REFRAKCE A ABERACÍ PO OPERACI ŠEDÉHO ZÁKALU ............................................................ 178
CHANGE IN REFRACTION AND ABERRATION AFTER CATARACT SURGERY............................................ 182
BC. LENKA NOVOTNÁ, DIS.
MUDR. TOMÁŠ MŇUK
PRIZMATICKÁ KOREKCE..................................................................................................................... 187
PRISMATIC CORRECTION.................................................................................................................... 193
BC. TEREZA OUHELOVÁ
MGR. MATĚJ SKRBEK
ZMĚNY ENDOTELOVÝCH BUNĚK ROHOVKY A NITROOČNÍ TEKUTINY PO OPERACI KATARAKTY
FEMOEMULZIFIKACÍ A ZA ASISTENCE FEMTOSEKUNDOVÉHO LASERU............................................... 199
CHANGING OF CORNEAL ENDOTHELIAL CELLS AND AQUEOUS HUMOR AFTER CATARACT SURGERY
USING PHACOEMULSIFICATION AND FEMTOSECOND LASER-ASSISTED PROCEDURE ........................... 206
BC. KATEŘINA PAVLÍČKOVÁ
DOC. MUDR. ŠÁRKA PITROVÁ, CSC., FEBO
SYMETRICKÁ A ASYMETRICKÁ KONVERGENCE .................................................................................. 213
SYMMETRIC AND ASYMMETRIC CONVERGENCE................................................................................. 217
BC. NIKOLA REPKOVÁ
MGR. MATĚJ SKRBEK
VLIV ANIZOMETROPIE NA KVALITU VIDĚNÍ ....................................................................................... 220
ANISOMETROPIA EFFECT ON THE QUALITY OF VISION........................................................................ 228
BC. EVA STAFFOVÁ
MGR. PETR VESELÝ, DIS., PH.D.
LIDS AND CONTACT LENSES............................................................................................................... 236
ERNA VUKALIĆ
PROGRAM
7. celostátní studentské konference Optometrie a
ortoptiky s mezinárodní účastí
pořádané dne 20. 10. 2016 v 10:00 hod.
Posluchárna P31 FSS MU, Joštova 10, 60200 Brno
kontakt: optobrno@med.muni.cz,
csko.muni@gmail.com
9.00 – 9.45 Registrace účastníků - Registration
10.00 – 10.20 1. Zahájení – Opening
za vedení: doc. MUDr. Svatopluk Synek, CSc., přednosta KOO LF MU
za hosty: Prof. Alen Stranjik, mag. ing. aeronaut, University of Applied
Sciences Velika Gorica, Kristina Mihić, M.Sc. in Vision Science and
Business, University of Applied Sciences Velika Gorica
za sponzora: Roman Veselý, ředitel firmy Cooper Vision, generální sponzor,
Mgr. Emanuel Řehola, ředitel společnosti Topcomed
za studenty: Bc. Barbora Hráčková
10.20 – 10.50 2. Bc. Tomáš Dobřenský: Faktory ovlivňující zdravé a pohodlné používání
kontaktních čoček – Factors influencing healthy and comfortable wearing of contact
lenses
10.50 – 11.00 3. Bc. Markéta Hrabovská, Mgr. David Severa: Změny akomodačně vergenčních
vlastností v závislosti na věku – Age-related changes of acommodative vergent attributes
11.00 – 11.10 4. Bc. Jolana Nedvědová, Mgr. Matěj Skrbek: Snášenlivost vertikálního prizmatu
– The tolerance of vertical prism
11.10 – 11.45 5. Mgr. Jitka Krasňanská, Ph.D., Bc. Michal Krasňanský, M.Sc.: Představení
přístrojů, metodika workshopů – Introduction of devices, methodology of workshops
11.45 – 11.55 diskuze k přednáškám – Discussion
11.55 – 12.15 6. prezentace posterů – Poster presentation
12.15 – 13.00 1. přestávka -1st break WORKSHOP 2x15min
13.00 – 13.10 7. Bc. Karolína Fojtlová, Mgr. Andrea Jeřábková: Rozdíly v hodnotě
dioptrického nálezu u dětí v závislosti na použití cykloplegie - Differences in
refraction of children with and without cycloplegia
13.10 – 13.20 8. Bc. Petra Janoušková, Mgr. Matěj Skrbek: Indikace k operaci šedého zákalu –
Indication for cataract surgery
13.20 – 13.30 9. Bc. Pavla Hrabalová, Mgr. Simona Bramborová, DiS.: Statická versus dynamická
zraková ostrost – Static versus dynamic visual acuity
13.30 – 13.40 10. Bc. Ivo Hlinomaz, Mgr. Ondřej Vlasák: Vytíženost využití Pentacamu při
diagnostice keratokonu – The use of Pentacam in the diagnosis of keratoconus
13.40 – 13.50 11. Sara Lončar, Dorotea Prguda: The cornea, sclera and conjunctiva tarsal gradation
degrees – Hodnocení nálezů na rohovce, bělimě a tarzální spojivce
13.50 – 14.00 12. Bc. Hana Štolzová, Mgr. Ondřej Vlasák: Irisregistrace - Irisregistration
14.00 – 14.05 diskuze k přednáškám - Disscusion
14.05 – 14.50 2. přestávka - 2nd break WORKSHOP 3x15min
14.50 – 15.05 13. soutěž - Competition
WORKSHOPY - WORKSHOPS:
Štěrbinová lampa (Slit lamp), Bezkontaktní tonometr (Non-contact tonometer), Fundus kamera (Fundus camera),
Rohovkový topograf (Topographer), ARK, Optotyp do blízka (Near optotype), Akomodometr (Acommodometer), a další.
AFTERPARTY:
Místo konání akce bude upřesněno
18.00 – 18.15
Vyhlášení (Ceremony):
- nejzajímavější přednáška – hodnotí účastníci konference (the best oral presentation- voted by participants),
- nejlepší poster (the best poster, voted by committee) – vyhodnotí komise ve složení: doc. MUDr. Svatopluk Synek,
CSc., Bc. Tomáš Dobřenský a zástupci studentů
- výsledky soutěže + vylosování 3 výherců (competition results + lottery of 3 winners)
19.00 - ……………………………..
Raut, volná zábava (Raut, party)
15.05 – 15.15 14. Bc. Zuzana Odvárková, Mgr. Petr Veselý, DiS., Ph.D.: Barevné folie a dyslexie –
Colour overlays and dyslexia
15.15 – 15.25 15. Bc. Lucie Klusoňová, Mgr. Sylvie Petrová: Oční protézy – Ocular prostheses
15.25 – 15.35 16. Bc. Veronika Krchňáková, Mgr. Pavel Kříž: Adaptace na tmu v závislosti na
věku – Dark adaptation depending on age
15.35 – 15.40 diskuze k přednáškám – Discussion
15.40 – 16.05 3. přestávka + hodnocení konference účastníky WORKSHOP 1x15min
3rd break + Conference evaluation by participians
16.05 – 16.20 17. zhodnocení studenty, sponzorem, hosty – Evaluation by students, sponsor, guests
16.20 – 16.30 18. doc. MUDr. Svatopluk Synek, CSc.: Závěrečné slovo - The final words
POSTERY- POSTERS:
1. Bc. Nikola Repková, Mgr. Matěj Skrbek: Symetrická a asymetrická konvergence – Symmetric
and asymmetric convergention
2. Bc. Lenka Novotná, MUDr. Tomáš Mňuk: Změna refrakce a aberací po operaci šedého zákalu – Change in
refraction and aberration after cataract surgery
3. Bc. Zuzana Gerbocová, MUDr. Magdaléna Macurová: Přístroje potřebné pro vyšetření zrakového nervu
při diagnostice glaukomu, metodika vyšetření – Devices needed for examination of the optic nerve head in
glaucoma diagnostics, methodology of examination
4. Bc. Andrea Hanušová, Mgr. Radek Anderle, Ph.D.: Metodika stanovení hodnoty optimální akomodační šíře,
ověření závislosti naměřených hodnot na pracovní vzdálenosti – Methodology of setting the optimal acommodation
amplitude, the verification of measured values depending on working distance
5. Bc. Tereza Ouhelová, Mgr. Matěj Skrbek: Prizmatická korekce – Prismatic correction
6. Bc. Eva Staffová, Mgr. Petr Veselý, DiS., Ph.D.: Vliv anizometropie na kvalitu vidění - Anisometropia effect on
the quality of vision
7. Bc. Barbora Hráčková, Bc. Veronika Krchňáková, Bc. Zuzana Odvárková, Bc. Kateřina Rosová: Erasmus
v Chorvatsku – Erasmus in Croatia
8. Bc. Barbora Hráčková, Bc. Marie Kodetová, Mgr. Pavel Beneš, Ph.D.: Dodržování hygieny a návyky nositelů
měkkých kontaktních čoček – Compliance and hygiene behaviour among soft contact lens wearers
9. Bc. Michaela Gagová, Mgr. Petr Veselý, DiS., Ph.D.: Internetový a samoobslužný prodej - nový fenomén v
oboru optika a optometrie, výhody a rizika pro klienty – Internet sales and self-service – a new phenomenon in the
field of optics and optometry, benefits and risks for the client
10. Bc.Martin Fůs, Doc. MUDr. Šárka Pitrová, CSc., FEBO: Určení polohy torických nitroočních čoček za pomoci
navigačního systému – Determing the position of toric IOLs using a navigation system
11. Bc. Kateřina Pavlíčková, Doc. MUDr. Šárka Pitrová, CSc., FEBO: Změny endotelových buněk rohovky a
nitrooční tekutiny po operaci katarakty fakoemulzifikací a za asistence femtosekundového laseru – Changing of
corneal endothelial cells and aqueous humor after cataract surgery using phacoemulsification and femtosecond laserassisted
procedure
12. Josipa Bagarić, Matija Dubovski: The relationship between myopia and corneal astigmatism in students of
optometry in Croatia – Závislost mezi myopií a rohovkovým astigmatizmem u studentů optometrie v Chorvatsku
13. Erna Vukalić: Lids and contact lenses – Víčka a kontaktní čočky
Sekce prezentací
Presentation section
VII. CSKO 20. 10. 2016
1
Faktory ovlivňující zdravé a pohodlné používání kontaktních
čoček
Autor: Bc. Tomáš Dobřenský
Anotace
Správný výběr parametrů kontaktních čoček pro klienta má samozřejmě klíčový význam
na jejich pohodlné používání. Proto je první část věnována právě technickým parametrům
kontaktních čoček. Za mnoha případy diskomfortu je ale skryto i nedodržování zásad a
správných návyků při používání kontaktních čoček. Tomuto tématu se pak budeme věnovat
v druhé části.
Úvod
Kontaktní čočky se liší v použitých materiálech, designu a technickém řešení s ohledem
na korigovanou refrakční vadu. Konstrukce kontaktní čočky by měla splňovat následující
základní kritéria: Kontaktní čočka by neměla působit mechanický stres oka a okolí. Vzájemná
interakce kontaktní čočky, povrchu oka a očních víček by nikdy neměla vyvolávat pocit
nepohodlí. Základními předpoklady je zde správná poloha čočky, centrace a přiměřený pohyb
čočky na oku.
Kontaktní čočka by měla co nejméně omezovat oplachování oka slzným filmem. S tím je
totiž spojený dostatečný přísun kyslíku k rohovce a naopak odvod metabolických zplodin od
ní. Tento faktor je ovlivněn celkovou konstrukcí čočky a hlavně oblastí jejího okraje.
Důležitou vlastností materiálu je propustnost kyslíku a dalších malých plynných molekul.
Materiál kontaktní čočky se podílí i na celkovém mechanickém dráždění, kde jsou důležitými
faktory modul pružnosti, povrchová smáčivost i celkový obsah vody v materiálu.
Design čočky
Základní popisné parametry kontaktních čoček uvedené na všech produktech jsou
základní zakřivení (BC = Base Curve) a průměr (DIA = Diameter)
Aplikaci kontaktních čoček ovlivňují oba tyto parametry, tedy přesněji řečeno, výsledná
aplikace je vzájemným vztahem mezi zakřivením a průměrem kontaktní čočky a tvarem
rohovky oka a oblasti sklerokorneálního přechodu. Otázkou je, nakolik oba popisné parametry
skutečně popisují tvar kontaktní čočky.
Pokud jde o průměr čočky, tady je odpověď jednoznačná. Průměr kontaktní čočky v plně
hydratovaném stavu je skutečně takový, jak je uvedeno na jejím balení. Rohovka má ve většině
případů průměr do 12 mm, pro průměr měkké sklerokorneální čočky pak platí, že by měla
přesahovat přes limbus alespoň o 0,5 mm na každé straně. Standardně se vyrábí nejmenší
průměr měkkých kontaktních čoček 13,6 mm. Běžný průměr pak je 14,0 až 14,5 mm.
Komplikovanější je to s otázkou zakřivení. Základní zakřivení kontaktní čočky je popisný
údaj, který vyjadřuje centrální zakřivení čočky v oblasti přibližně dvou až tří milimetrů
v průměru. Konstrukce zadní plochy čočky je ale ve většině případů asférická a tedy skutečné
VII. CSKO 20. 10. 2016
2
zakřivení v těchto místech neodpovídá popisné hodnotě. Údaj o zakřivení je z tohoto úhlu
pohledu pro nás hodnotou orientační. V literatuře se nejčastěji uvádí, že hodnota zakřivení
kontaktní čočky by měla být o jeden milimetr plošší, než je průměrná keratometrie centra
rohovky. Toto pravidlo skutečně platí v případě, že křivka zadní plochy kontaktníčočky je blízká
rotačnímu hyperboloidu. Ale současné křivky zadních ploch čoček jsou výrazně složitější.
Většina kontaktních čoček se dodává na trh v jednom, maximálně dvou různých zakřiveních.
Tento stav nás často vede, v kombinaci s ostatními parametry čoček, k určitému aplikačnímu
kompromisu. Bez kontroly aplikace na štěrbinové lampě ale nejsem schopen správný výběr
potvrdit.
Přesná aplikace kontaktních čoček předpokládá, že tvar čočky bude „kopírovat“ tvar
rohovky a výsledkem bude paralelní postavení kontaktní čočky vůči rohovce ve všech bodech.
Tento ideální stav nastává velmi zřídka. Mnohem častější, vzhledem k nepravidelnému tvaru
rohovek a většinou také kontaktních čoček, je situace, kdy v některých oblastech je kontaktní
čočka povrchu rohovky blíž a jinde dál.
Obvykle je centrální optická oblast kontaktní čočky jako celek strmější než příslušně
velká oblast rohovky. To je celkem paradoxní vzhledem k tomu, že pokud jde o uváděné
centrální zakřivení (BC = Basic Curve), volíme popisně plošší hodnotu, než je průměrná
keratometrie centra oka.
V oblasti přechodu mezi optickou a haptickou částí čočky, bývá její přiblížení k rohovce
nejtěsnější. Okraj kontaktních čoček by pak opět měl směřovat mírně od povrchu oka.
Charakteristika okraje kontaktní čočky ale může být velmi různorodá. Na obrázku
z elektronového mikroskopu vidíme několik různých typů kontaktních čoček od různých
výrobců. Je tu zřejmé, že k problematice okraje čoček rozhodně nepřistupují jednotně.
Dokonce se dají rozdělit do čtyř různých „kategorií“: okraje směřující vzhůru a to do břitového
nebo zaobleného tvaru a podobně okraje směřující dolů: opět buď břitové, nebo zaoblené.
Z dříve řečeného se okraje směřující dolů zdají být celkem nelogickým řešením. Jenže,
ono také záleží na tvaru přechodu mezi rohovkou a sklerou. Pokud je sklerokorneální úhel
velmi otevřený, pak čočka s okrajem vzhůru může příliš odstávat od povrchu oka a výsledkem
je neúměrné dráždění tarzální plochy víčka, případně okraj víčka může přímo hrnout takovou
čočku z oka ven. Naopak, u ostřejšího sklerokorneálního úhlu by se čočka s okrajem dolů
mohla okrajem opírat do perilimbální oblasti. Jednak tu bude působit otlak, ale především
uzavře přirozený průtok slz pod kontaktní čočku. Výsledkem takové aplikace je hypoxie
rohovky. Rohovce totiž chybí kyslík přiváděný výměnou slzného filmu a tento nedostatek není
schopen pokrýt ani ten nejprodyšnější materiál na trhu.
Další důležitou vlastností kontaktní čočky je schopnost stejnoměrně rozkládat tlak, který
na přední segment oka působí. Tento tlak vyvolávají oční víčka, především okraj tarzu. To platí
při otevřeném oku a samozřejmě pak v průběhu mrknutí. Mrkání a tlak okrajů víček je určující
veličinou při řadě dynamických dějů po aplikaci čočky na oku. U sférických nestabilizovaných
kontaktních čoček je výsledkem tlaku okrajů víček při mrkání rotace čočky. Ta spolu s mírným
pohybem nahoru a dolů a také s mírným „pumpovacím“ efektem přitlačením čočky k oku a
opětovným uvolněním, rovněž napomáhá tolik potřebné výměně slz pod čočkou. U
VII. CSKO 20. 10. 2016
3
kontaktních čoček, které vyžadují stabilizaci na oku – například všechny torické kontaktní
čočky - je výměna slz pod čočkou nižší. Jednak chybí rotace, dále čočka kvůli stabilizačním
prvkům je tlustší a tedy pump efekt není tak silný. A často je taková čočka větší i v průměru. O
to více tady záleží na správné volbě parametrů čočky a jejich následné kontrole.
U měkkých kontaktních čoček se musí konstrukce podřídit obsahu vody, elasticitě,
propustnosti pro kyslík, transportu tekutin v materiálu a evaporaci (osychání). Existují přesně
stanovené hodnoty konstrukčních údajů, kde je mimo jiné uvedena minimální středová
tloušťka čočky. Není problém takto tenké, nebo i tenčí čočky vyrobit, ale využít se prakticky
nedají. Takto tenká čočka by se po aplikaci propadla v centrální oblasti a adhezí slz přichytila k
rohovce. Tím by se omezil její pohyb, nedocházelo by k výměně slz pod čočkou, tedy by se
nepřiváděl kyslík a neodváděly zplodiny metabolismu. Proto je nutné tloušťku čočky vždy
vyvážit k příslušnému materiálu.
Vlivy materiálu
Základním a referenčním materiálem měkkých kontaktních čoček je
hydroxyetylmetakrylát – HEMA. Kontaktní čočky z čistého materiálu HEMA obsahují mezi 36
až 38% vody. Voda přitom má v čočce zcela zásadní význam, pokud jde o snášenlivost
materiálu na oku – většinou ji hodnotíme prostřednictvím smáčivosti povrchu, dále jeho
jemnost a pružnost – obvykle dnes vyjádřenou modulem pružnosti čočky, a v neposlední řadě
propustnost materiálu pro kyslík – nejčastěji uvádíme hodnoty Dk a Dk/t. Přídavkem
kopolymerů, jako jsou například vinylpyrolidon, vinylakrylát nebo glycerylmetakrylát, je
možné obsah vody zvýšit – technicky se používá maximální obsah vody okolo 70%. U
hydrogelových materiálů se spolu s vyšším obsahem vody zlepší pružnost a jemnost materiálu
i jeho propustnost pro kyslík. Samostatný polymer je totiž pro plyny nepropustný, proto je
rozhodující obsah vody v hydrogelu, který určuje jeho difuzivitu.
V dnešní době na trhu měkkých kontaktních čoček naprosto převládají materiály s
kategorie silikon hydrogelů. Obsah siloxanů v materiálu čočky výrazně zlepšuje její
propustnost pro kyslík. Molekuly kyslíku stejně jako odpadního CO2 mohou procházet přímo
strukturou silikon hydrogelového materiálu. Teoreticky tak platí, že vyšší obsah vody v silikon
hydrogelových materiálech propustnost pro kyslík snižuje. Na druhou stranu siloxanové
struktury jsou mechanicky tužší a méně ohebné, než tomu je u hydrogelů. Výsledkem je vyšší
hodnota modulu pružnosti. Čisté siloxany jsou také hydrofobní a to má za následek horší
povrchovou smáčivost čočky a větší afinitu k vazbě lipidových depozit na povrch čočky.
S těmito vlastnostmi se většina výrobců snaží bojovat a postupně se mění vnitřní provázanost
jednotlivých struktur materiálu, stejně jako se hledá optimální vyvážený poměr obou složek
pro zachování většiny výhod jak hydrogelů, tak silikon hydrogelů. Moderní silikon hydrogely
se sice možná nepyšní nejvyššími hodnotami propustnosti pro kyslík, zato ale mají výrazně
nižší modul pružnosti, lepší povrchovou smáčivost a vyšší celkový obsah vody.
Hydrogelové materiály jsou díky nižšímu modulu pružnosti více přizpůsobivé tvaru
rohovky pod sebou. Také adhezní síly jsou u hydrogelů vyšší než u silikon hydrogelových čoček.
Důsledkem toho může být menší pohyb čočky na oku a obtížnější hodnocení přesnosti její
VII. CSKO 20. 10. 2016
4
aplikace. Vyšší modul pružnosti u některých silikon hydrogelových čoček zase klade větší
nároky na výběr správných parametrů.
Vliv správného používání kontaktních čoček
Anglický termín ‚complience‘ vyjadřuje právě úroveň dodržování, nebo spíše
nedodržování doporučení, ale i striktních nařízení, spojených s používáním kontaktních čoček
konečnými uživateli. Jedna věc je, jak jsou instrukce předány, zda jsou srozumitelné a dávají
smysl. Druhou věcí pak je konečné chování uživatelů čoček v praxi.
Obecně lze říct, že za velké množství komplikací spojených s používáním kontaktních
čoček jsou odpovědní sami jejich uživatelé. Až 80% těchto potíží vychází z nedodržování
předepsaných režimů. Současně platí, že čím jednodušší péče se doporučí, tím méně se
dodržuje.
Podle studie prováděné v roce 2015 ve Velké Británii týmem pod vedením profesora
Durbana až 20% uživatelů kontaktních čoček si není vědomo, jaký typ čoček vlastně používá.
40% uživatelů používá čočky déle, než výrobce doporučuje, konkrétně podle doporučeného
režimu používání: 15% uživatelů jednodenních čoček, 29% uživatelů měsíčních čoček a 59%
uživatelů čtrnáctidenních čoček.
Typičtí uživatelé nedodržující pravidla jsou mladší (33,1 ± 11,0 let) než ti, co režim
dodržují (35,0 ± 12,8 let). Naopak nebyl zjištěn žádný zásadní rozdíl mezi ženami a muži. A
nezáleží ani na dioptrické korekci. Typické je rovněž to, že tito lidé nechodí na pravidelné
kontroly ani na měření zraku při nákupu brýlí nebo čoček. Statisticky některá z pravidel
porušovalo 79% nositelů čoček ve studii.
Důvody pro nedodržování postupů uváděné ve studii lze rozdělit do následujících
kategorií: péče o čočky jim připadá zbytečně zdlouhavá, nebo zbytečně častá. Prostředky o
péči jsou příliš drahé. Nebo se odvolávají na tvrzení, že když jim někdo něco předepsal, musí
to být bezpečné samo o sobě.
Pokud jde o péči o čočky, 78% nositelů čoček je mechanicky vůbec nečistí. 18% uživatelů
nemění roztok v pouzdře, pouze jej doplňuje. K nedodržení času předepsanému k dezinfekci
čoček se přiznalo 12% jejich uživatelů. Až 5% pak používá k péči o kontaktní čočky pouze
fyziologický roztok. A až 50% uživatelů udává, že si někdy před manipulací s čočkou neumyjí
ruce.
Obecně špatná je pak péče o pouzdro na kontaktní čočky. Až 80% nositelů čoček nedělá
pravidelnou hygienu pouzdra. Téměř polovina uživatelů jej nenechává přes den vyschnout. A
62% jej nevyměňuje v předepsaném intervalu.
Jak postupovat správně
Výběr vhodného typu čočky by měl být vždy v rukou očního specialisty. Nedílnou
součástí výběru je jeho ověření na štěrbinové lampě. Stejně tak jsme odpovědní za správné
poučení klienta o způsobech používání a péče o čočky. V dnešní době se z tohoto úhlu pohledu
jeví jako optimální doporučení používání jednodenních silikon hydrogelových kontaktních
čoček, kde míra nedodržování pravidel hry je logicky nejmenší.
VII. CSKO 20. 10. 2016
5
Zdroje
Papas, E. Treatment and management of contact lens-related discomfort, Optician Magazine,
February 2015
Wilcox, M. Institute for Eye Research. Presented at the annual meeting of BCLA 2015
CooperVision, data on file
VII. CSKO 20. 10. 2016
6
Factors influencing healthy and comfortable wearing of
contact lenses
Author: Bc. Tomáš Dobřenský
Abstract
Proper selection of parameters of contact lenses for the client is obviously crucial to
their ease of use. Therefore, the first part is devoted to the technical parameters of contact
lenses and their influence on the comfort of use. But for many cases of discomfort is hidden
non-compliance and good habits during using of contact lenses. This topic will then be
discussed in the second part.
Introduction
Contact lenses are differed in the used materials, design and technical solutions with
regard to the corrected refractive error. Construction of contact lenses should meet the
following basic criteria: Contact lenses should not cause mechanical stress of the eye and
surrounding area. Mutual interaction of contact lenses, eye surface and the eyelids should
never cause discomfort. The basic assumptions are correct position of the lens, centration and
reasonable movement of the lens on the eye.
The contact lens should at least limit the flushing of the tear film on the eye. With this is
connected a sufficient supply of oxygen to the cornea and also removal of metabolic waste
from it. These factors are influenced by the overall design of the lens and its edge.
Important characteristic of the material is permeability for oxygen and other small
gaseous molecules. Contact lens material also contributes to the overall mechanical irritation,
where are important factors modulus, surface wettability and the total water content in the
material.
The influence of Lens design
The basic descriptive parameters of contact lenses listed on all the products are: Base
curve (BC = Base Curve) and Diameter (DIA = Diameter).
Both of these parametres influence to the contact lens fit. More precisely speaking, the resulting
application is the relationship between the curvature and diameter of contact lenses, corneal shape of
the eye areas and sclera-corneal angle. The question is whether both descriptive parameters really
describing the shape of a contact lens.
Regarding the diameter of the lens, there is a clear answer. Diameter of the contact lens in a
fully hydrated state is indeed such as indicated on the package. The cornea has in most cases diameter
to 12 mm. The diameter of the soft lens should overlap the limbus at least 0.5 mm on each side.
Standard is produced the smallest diameter of the soft contact lenses as 13.6 mm. Most of production
is between 14.0 and 14.5 mm.
With curve it is a more complicated question. BC of a contact lens is descriptive data, which
expresses the central curvature of the lens in approximately two or three millimeters in diameter. But
the rear surface of the lens in most cases has aspheric curvature and in these options the descriptive
VII. CSKO 20. 10. 2016
7
value of BC is not so big. Indication of curvature is from this perspective orientation value only. The
literature often indicates that the value of the curvature of the contact lens should be about one
millimeter flatter than the average keratometry of central cornea. This rule really applies in the case
that the curve of the back surface of the contact lens is close to oblate spheroid. But the current curve
of the rear lens surfaces are considerably more complicated. Most of contact lenses are marketed in a
maximum of two different curvatures. This condition often leads us, in combination with other
parameters of the lenses, make some compromise in fits. Without control on the slit lamp I am unable
to confirm the correct choice.
The precise application of contact lenses assumes that the shape of the lens "copy" the shape
of the cornea and results in the parallel position of the contact lens to the cornea at all points. The
ideal situation occurs very rarely. Much more common, due to the irregular shape of corneas, and
contact lenses too, usually it is a situation where in some areas is the contact lens closer to corneal
surface than in others.
Usually the central region of the optical lenses is steeper than corresponding area of the cornea.
It is quite paradoxical in view of the fact that as regards the mentioned central curvature is chosen
flatter than the average keratometry of centre of eye.
The area between optical and haptic part of the lens is its closest approach to the cornea. Edge
of contact lens would again be directed slightly from the surface of the eye. Characteristics of edge of
contact lenses but may be very diverse. On the pictures from electron microscope we see several
different types of contact lenses from different manufacturers. It's obvious, that the issue of the edges
of the lenses is definitely not treated uniformly. Even can be divided into four different "categories":
the edges pointing upwards and into the shaped or rounded edges and the like pointing down: either
shaped or rounded.
From previously said edges facing down seem quite illogical solution. However, it also depends
on the shape of the angle between the cornea and sclera. If this angle is very open, then the lens edge
can´t protrude upword from the surface of the eye and result in excessive irritation of the tarsal area
lid or rim of the cap may directly pouring a lens out from the eye. Conversely, at a sharper angle should
lens edge to edge down to lean perilimbal area. First, there is cause of bruising, but also closes the
natural flow of tears under the lens. The result is hypoxia of cornea. The cornea is lacking of oxygen
supply in exchange of the tear film and this deficiency is not able to cover even the most permeable
material on the market.
Another important property of contact lenses is the ability to uniformly distribute the pressure
that the front segment of the eye operates. This pressure rise eyelids, especially edge of tarsus. This
applies with open eyes and then, of course, during the blink. Blinking and pressure of edges of the
eyelids is the defining parameter in a number of dynamic processes, after application of the lens on
the eye. For spherical contact lenses rotation of the lens is a result of the pressure of edges of eyelids
during the blinking. This, together with a slight up and down movement, and with a slight "pumping"
effect of pressing the lens to the eye and re-release, also helps much needed exchange of tears under
the lens. For contact lenses which require stabilization on the eye - for example all toric contact lenses
– is the exchange of tears under the lens lower. First, lack of rotation, as well as a lens due to the
stabilizing element is thicker and thus pump effect is not so strong. Often such a lens is a larger in
diameter. The more here depends on the correct choice of parameters lenses and their follow-up.
In soft contact lenses construction must conform water content, elasticity, oxygen permeability,
fluid transport in the material and evaporation (drying time). There are well-defined value of design
VII. CSKO 20. 10. 2016
8
data, which also indicate the minimum central thickness of the lens. There is no problem to produce
this thin or even thinner lenses, but can´t be used practically. Thus a thin lens should be dropped after
application in the central area and by tears adhesion will be sticking to cornea. This would limit its
movement, there would be no exchange of tears under the lens, therefore, would refrain from the not
flow of oxygen and waste products of metabolism. So this is why we must balance the thickness of
each lens to the appropriate material.
Influence of Material
The basic reference material for soft contact lenses is hydroxyethyl methacrylate HEMA.
Contact lenses of pure HEMA material contain between 36-38% of water. Water
content is crucial as regards the compatibility of the material in the eye - usually it evaluate
by surface wettability, as well as its softness and flexibility - usually today expressed as
modulus of the lens, and finally permeability of material for oxygen - typically shows as Dk and
Dk/t. Addition of copolymers such as vinylpyrrolidone, vinyl acrylate or glyceryl methacrylate,
it is possible to increase the water content - technically is used the maximum water content
about 70%. For hydrogel materials, along with a higher water content improves the flexibility
and softness of the material and its permeability to oxygen. Isolated polymer is impermeable
to gases, so the water content is critical for the hydrogel to determine its diffusivity.
Today on the market of soft contact lenses absolutely predominant materials from
silicone hydrogels category. Siloxane content in the lens material greatly improves its oxygen
permeability. Oxygen molecules can come directly across the structure of silicone hydrogel
material. Theoretically, a higher water content in the silicone hydrogel materials decreases
oxygen permeability. On the other hand, siloxane structure is mechanically stiffer and less
pliable than in the case of hydrogels. The result is a higher modulus value. Pure siloxanes are
hydrophobic, and this results in worse surface wettability of the lens and a greater affinity for
binding of lipid deposits on the lens surface. With these features, most manufacturers try to
fight and gradually changing the coherence between the different structures of the material,
as well as looking for an optimal balanced ratio of the two components for maintaining most
of the benefits from hydrogels and silicone hydrogels. Modern silicone hydrogels may perhaps
not highest values of oxygen permeability, but have significantly lower modulus, improved
surface wettability and higher total water content.
Hydrogel materials are due the lower modulus more adaptable to the shape of the
cornea beneath. Also, adhesive strength in hydrogels are higher than in the silicone hydrogel
lenses. This can result in less movement of the lens on the eye and difficult to assess the
accuracy of its application. Higher modulus of some silicone hydrogel lenses in turn puts
greater demands on the selection of the correct parameters.
The influence of the correct use of contact lenses
Compliance or non-compliance of rather recommendations and strict regulations
associated with comfort use of contact lenses. One thing is how the instructions are passed,
next how they are understandable. Then the second thing is the final lens user behavior in
practice.
VII. CSKO 20. 10. 2016
9
Generally, we can say, that a large number of complications associated with the use of
contact lenses are accountable to their users. Up to 80% of these problems come from nonprescribed
regimens. And also, the simpler care to advise the less complies.
According to a study conducted in 2015 in the UK by a team led by Professor Durban
20% of users of contact lenses are not aware of what type of lenses actually used. 40% of users
wear lenses longer than the manufacturer recommends, specifically under the recommended
mode of use: 15% of daily disposable lenses, 29% of monthly lenses and 59% of two weeks
lenses.
Typical non-complying users are younger (33.1 ± 11.0 years) than those who follow
instructions (35.0 ± 12.8 years). Conversely, there was no significant difference between
women and men. And also there does not depend on the power of correction. Typical is also,
that these people do not go for regular exams to optometry when buying glasses or lenses.
Statistically, some of the rules violate the 79% lens wearers in the study.
Reasons for non-compliance procedures reported in the study can be divided into the
following categories: care for the lenses seems too lengthy or too often. Solutions for care are
too expensive. Or refer to the claim that when someone has prescribed something, it has to
be secure in itself.
Concerning lens care, 78% of lens wearers are not cleaning lenses mechanically (no rub).
18% of users do not change the solution in the case, it only adds. The failure to comply with
the prescribed time to disinfect the lenses admitted 12% of their users. Up to 5% were used
for the care of contact lenses only saline. And 50% of users indicate that ever before handling
lenses unwashed hands.
Generally bad then care case for contact lenses. Up to 80% of lens wearers don´t doing
regular hygiene of case. Nearly half of the users do not leave case during the day to dry. A 62%
don´t exchange case in prescribed interval.
How to proceed correctly?
Selecting the appropriate type of lenses should always be in the hands of an eye
specialist. An integral part of the selection is his validation on the slit lamp. We are responsible
for the proper instruction of the client on ways to use and care of the lenses. Today, from this
perspective seems optimal recommend to use daily disposable silicone hydrogel contact
lenses, where the rate of compliance with the rules of the game is logically the smallest.
Resources
Papas, E. Treatment and management of contact lens-related discomfort, Optician Magazine,
February 2015
Wilcox, M. Institute for Eye Research. Presented at the annual meeting of BCLA 2015
CooperVision, data on file
VII. CSKO 20. 10. 2016
10
Rozdíly v hodnotě dioptrického nálezu u dětí v závislosti na
použití cykloplegie
Autor: Bc. Karolína Fojtlová
Školitel: Mgr. Andrea Jeřábková
Úvod
Vyšetřování zrakové ostrosti u dětí se potýká hned s několika úskalími. V první řadě je
třeba si uvědomit, že zraková ostrost se v průběhu prvních let života teprve vyvíjí a nelze ji
srovnávat se zrakovou schopností dospělých. Další otázka, která se nabízí, je samotná
komunikace s dětmi a od ní se odvíjející způsob, jakým vyšetření provedeme. U nejmenších
dětí nám nezbude nic jiného, než se spoléhat na hodnoty naměřené objektivně, u dětí
předškolních a školáků se lze dopátrat i subjektivního dokorigování volbou vhodných testů
úměrných schopnostem dítěte. Poslední z výčtu problémů je velká akomodační schopnost dětí
a s tím spojená nesprávná diagnostika refrakční vady. Proto se jeví nezbytné používat při
pátrání po vhodné korekci cykloplegii k vyloučení akomodačního vlivu.
Vývoj zrakové ostrosti
Po narození stále ještě není dokončen vývoj v makulární oblasti, tudíž v tomto období
převládá skotopické vidění a světlocit. Novorozenec je vybaven dvěma reflexy:
pupilomotorickým a optokinetickým. Od prvního měsíce můžeme zaznamenat monokulární
fixaci a dítě již rozeznává pohyb. V dalších měsících se postupně vyvíjí binokulární fixace a
upevňuje se centrální fixace. Dítě rozlišuje blízké a vzdálené předměty díky konjugovaným a
disjungovaným očním pohybům. V šestém měsíci je ukončen vývoj makuly a zraková ostrost
odpovídá 1/50. Vyvíjí se také fúzní reflex. Během devátého měsíce dosahuje zraková ostrost
hodnoty 5/50, v jednom roce pak 5/25 a dochází k zpevňování binokulárních reflexů. Ve třech
letech koresponduje zraková ostrost s visem 5/10 a utužuje se reflex fixační. Mezi 4. – 6. rokem
věku se visus stabilizuje na hodnotu 5/5 a vyrovnává se tak zrakové schopnosti dospělého
člověka.
Metody vyšetření refrakce u dětí
Při určování refrakce u dětí můžeme využít objektivní skiaskopie, jejíž hlavní výhody
spočívají v nenáročném přístrojovém vybavení a rychlosti a přesnosti vyšetření, pokud lékař
tuto techniku ovládá. Hlavním principem je vyhodnocení chodu světelných paprsků
odražených od sítnice, čímž je vyvolán červený reflex. Podle pohybu stínu v červeném reflexu
pak usuzujeme na refrakční vadu. Cílem metody je nalézt tzv. neutrální bod, kdy vymizí pohyb
stínu, čehož dosáhneme předkládáním vhodných korekčních členů.
Další a dnes využívanější metodou je vyšetření na autorefraktometru. Jedná se o
automatická zařízení, která jsou z fyzikálně-optického hlediska inspirována oftalmoskopií,
skiaskopií, Scheinerovým pokusem, paralaxním uspořádáním měřících a vyhodnocovacích
prvků i principem zaostřování obrazu. Společným prvkem všech těchto přístrojů je
infračervené světlo o vlnové délce kolem 880 nm, které se využívá k vlastnímu měření, aniž by
VII. CSKO 20. 10. 2016
11
jej oko vyšetřovaného zaznamenalo. První generace autorefraktometrů neměla k dispozici
fixační značku, jež má za úkol odstranit nadměrnou akomodaci oka. V druhé generaci přístrojů
byl již tento problém ošetřen a třetí generace obsahuje dokonce i modul pro subjektivní
vyšetření. Ten však není příliš využíván pro svou značnou chybovost.
Alternativou automatických refraktometrů může být přístroj Plus Optix, který se využívá
především pro screening zrakových vad u dětí. Aparát využívá principu excentrické
fotoskiaskopie a mezi jeho nesporné výhody patří rychlost a měření obou očí zároveň.
Vyšetření probíhá z jednoho metru a výstupní informace obsahuje nejen údaje o refrakčním
stavu oka, ale i o postavení očí, rohovkových reflexech, velikosti zornic či strabismu.
Metody vyšetření zrakové ostrosti u dětí
Všechny metody vyšetření zrakové ostrosti se odvíjejí od tří základních stimulů –
detekce, rozlišení a poznání. Podnětem pro detekci jsou nejčastěji bílé kruhy různých velikostí
na černém pozadí. K rozlišení se využívají černobílé mřížky různého jasu. V obou případech má
dítě za úkol stimuly od pozadí odlišit. Poznání využívá identifikace a pojmenování známého
symbolu či písmen dle věku dítěte.
U dětí nonverbálního věku se využívají testy preferenčního vidění odvíjející se od
předpokladu, že dítě bude sledovat strukturované podněty, pokud jej dostatečně upoutají.
Nejznámějšího zástupce těchto testů představují Tellerovy karty tvořené černými a bílými
pruhy různé šířky na šedé indiferentní ploše. Dítě by mělo tento vzor fixovat a dle šíře
nejjemnějších pruhů, které ještě rozezná, lze určit předpokládaný stupeň vidění.
Další objektivní technikou, kterou můžeme zjistit zrakové funkce u dětí, které pro svůj
věk nejsou prozatím schopny spolupráce, je snímání zrakových evokovaných potenciálů – VEP.
Jedná se o elektrofyziologickou metodu snímání vizuálních podnětů pomocí povrchových
elektrod umístěných na týlní části lebky.
Přesněji a za spolupráce vyšetřovaného lze vyšetřit zrakové funkce až u dětí od tří let.
Využívá se metody Grating acuity, která vychází z domněnky, že dítě již umí pojmenovat a
popsat různé symboly. Velikost testů se logaritmicky snižuje obdobně jako u optotypů. Na
tomto principu jsou založeny obrázkové Lea a Kay testy. Kromě obrázků můžeme také použít
Pflügerovy háky či Landoltovy kruhy, u školáků pak číselné nebo písmenné optotypy.
Cykloplegie
Abychom zamezili nesprávné diagnostice refrakční vady, je třeba u dětí vyloučit vliv
akomodace pomocí cykloplegik. Tato farmaka v podobě očních kapek působí jako
parasympatolytikum na vegetativní nervový systém. Parasympatikus inervuje pupilární
sfinkter a ciliární sval, aplikací léčiva dochází k blokaci muskarinových receptorů a tím pádem
k cykloplegii a mydriáze. Do skupiny cykloplegik řadíme například atropin či cyklopentolát,
známý také jako Cyclogyl. Počet kapek, které vyřadí akomodaci z provozu, se odvíjí od barvy
duhovky.
VII. CSKO 20. 10. 2016
12
Metodika práce
Ve své diplomové práci se zabývám rozdíly dioptrického nálezu u dětí před a po použití
cykloplegie. Potřebné údaje jsem získala výpisem z lékařských záznamů pacientů soukromé
ortoptické ambulance Mgr. Andrey Jeřábkové. Celkový počet subjektů se pohybuje kolem sta,
ve věkové skupině od 2 do 15 let. Jedná se o pacienty s ortoptickým statusem, tudíž drtivá
většina z nich je hypermetropická a nalezneme zde pouze malé procento myopů. K rozkapání
a uvedení do cykloplegie byl použit 1% Cyclogyl, vyšetření refrakce probíhalo objektivně na
autorefraktometru.
Hypotézy a dílčí výsledky
První hypotéza, kterou jsem si ve výzkumu stanovila, zní: „Hodnota myopie se
v cykloplegii snižuje, hodnota hypermetropie zvyšuje.” Dle mých dílčích výsledků se hypotéza
prozatím splňuje, ačkoliv fakt, že většina pacientů je hypermetropická, může vést ke zkreslení
výsledků. Pro srovnání bych uvedla výsledky určení vlivu 1% cyklopentolátu na refrakční status
u dětí z čínské provincie Shandong. Do statistické analýzy bylo zahrnuto 5999 dětí ve věku od
4 do 18 let, samotné měření probíhalo na autorefraktometru. Průměrný rozdíl refrakce před
a po použití cykloplegie byl 0,78 +/- 0,79 D. 66,4 % očí s myopií bez cykloplegie zůstalo
myopických i po jejím použití, 18% se stalo emetropickými a 15,7% hypermetropickými.
Z předchozího tedy vyplývá, že refrakce bez použití cykloplegie nevede pouze k nesprávným
hodnotám měření, ale dokonce i ke špatné klasifikaci refrakční vady.
V další hypotéze se zabývám korelací věku a výsledného rozdílu refrakce před a po
použití cykloplegie. Usuzuji, že s rostoucím věkem se snižují rozdíly dioptrického nálezu mezi
oběma metodami. Jelikož v mém předběžném vzorku nejsou věkové skupiny rovnoměrně
rozloženy, správnost této domněnky nelze prozatím potvrdit. Zde jsem vycházela z australské
populační studie, jež srovnává rozdíly refrakce v závislosti na cykloplegii u skupiny šestiletých
a u skupiny dvanáctiletých dětí. První soubor čítal 210 subjektů, druhý 2 233 subjektů. Měření
probíhalo opět na autorefraktometru před a po nakapání 1% cyklopentolátu. Průměrné
zvýšení sférického ekvivalentu po cykloplegii bylo o 0,84 D u 12ti letých a o 1,18 D u 6-ti letých
dětí. Precykloplegická refrakce podstatně přecenila podíl dětí s krátkozrakostí – chybně
klasifikovala 17,8 % 12ti letých a 9,5% 6-ti letých. Zároveň nedetekovala střední až vysokou
hypermetropii u 2,28% 12ti a 17,14% 6-ti letých dětí. Je tedy nutné vyzdvihnout důležitost
používání cykloplegie u dětí alespoň do 12 let.
Poslední hypotéza věnuje pozornost změně osy astigmatismu v závislosti na cykloplegii.
Předpoklad zní, že cylindrická osa by se neměla změnit o více než 10° u 80% subjektů, jelikož
dle mého mínění se vyloučení vlivu akomodace výrazně nepodílí na změně osy astigmatismu.
Moje předběžné výsledky prozatím tuto domněnku potvrzují.
VII. CSKO 20. 10. 2016
13
Zdroje
Kuchynka, P. Oční lékařství. 1.vyd. Praha: Grada, 2007, 768 s. ISBN 9788024711638.
Rutrle, M. Přístrojová optika: učební texty pro oční optiky a oční techniky, optometristy a
oftalmology. 1. vyd. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví, 2000, 189
s. ISBN 8070133015.
Papcunová, R. Korekce refrakčních vad dětského věku: bakalářská práce. Brno: Masarykova
univerzita, Fakulta lékařská, Katedra optometrie a ortoptiky, 2014, 64 s. Vedoucí bakalářské
práce Mgr. Matěj Skrbek.
Jeřábková, A. Stanovení zrakových funkcí u dětí. Česká oční optika. 2014, 55(4), 34-35. ISSN
1211-233X.
Fotedar, R. et al. Necessity of Cycloplegia for Assessing Refractive Error in 12-Year-Old
Children: A Population-Based Study. American Journal of Opthalmology. 2007, 144, 307-309.
HU, Y. Y. et al. Effect of Cycloplegia on the Refractive Status of Children: The Shandong
Children Eye Study. 2015. PLoS ONE 10(2): e0117482. doi:10.1371/journal.pone.0117482.
VII. CSKO 20. 10. 2016
14
Differences in refraction of children with and without
cycloplegia
Author: Bc. Karolína Fojtlová
Supervisor: Mgr. Andrea Jeřábková
Introduction
Examination of visual acuity in children fights with a few pitfalls. In the first place we
must realize fact, that visual acuity is developing during the first years of life and so we can’t
compare it with the visual skills of adults. Another issue, that emerges, is communication with
children and method of examination, which depends on options of communication. We can
use only objective methods at the smallest children. Preschool children and schoolchildren
could be examined by subjective tests depending on their skills. The next problem is large
accommodative ability of children which is connected with incorrect diagnosis of refractive
errors. Therefore, it is necessary to use cycloplegia to eliminate the influence of
accommodation, when we are searching for suitable correction.
Development of visual acuity
After birth macular area isn’t completely development, therefore in this period scotopic
vision and light perception are dominant. The newborn child has two reflexes: pupilomotoric
and optokinetic. From the first month we record monocular fixation and child already
recognizes movement. In following months binocular fixation is evolved and the central
fixation is consolidated. Child distinguishes between near and far objects through a
conjugated and convergent eye movements. In the sixth month evolution of macula is finished
and visual acuity corresponds with 1/50. Also fusion reflex develops in this period. During the
nine months visual acuity reaches value 5/50, in one year it is 5/25 and binocular reflexes is
fixed. Three years old child has visual acuity about 5/10 and reinforced the fixation reflex.
Between 4 to 6 years visual acuity is stabilized at 5/5, which corresponds with VA of adults.
The methods of refractive examination of children
If we want to examine refraction in children, we can use retinoscopy. The main
advantages of this method are simple instrumentation and the speed and accuracy of testing
if the doctor is able to use this technique. The main principle is evaluation of the light rays
reflected from the retina, which we call red reflex. According to the movement of the shadow
of the red reflex we can determine the refractive error. The aim of the method is finding a
neutral point when the movement of the shadow disappears. It happens, when we use right
corrective lens.
Currently autorefractometer is used for objective examination more often. This is an
automatic device inspired by ophthalmoscopy, retinoscopy, Scheiner’s experiment and
parallax organization of measuring and evaluation elements as well as the principle of image
focusing. A common feature of all these devices is infrared light with wavelength around 880
nm. This light can’t be recorded by measured eye. The first generation of autorefractometer
VII. CSKO 20. 10. 2016
15
didn’t have a fixation mark, which eliminates excessive eye accommodation. In the second
generation of devices has been this problem solved and the third generation even includes a
mode for subjective testing. But it isn’t used often because it makes lots of mistakes.
Alternative of automatic refractometer is device called Plus Optix. It is used primarily for
screening of refractive errors in children. System uses the principle of eccentric
photoretinoscopy and it offers speed measurement of both eyes together. Examination takes
place from one meter and output information contains information about the refractive status
of the eye, about the position of the eyes, corneal reflexes, pupil size or squint.
Examination of visual acuity of children
All methods of visual acuity testing are derived from three essential ideas – detection,
resolution and cognition. The stimuli for detection are mostly white circles of different sizes
on a black background. Black and white grid of different brightness is used for resolution. In
both cases, the child has the task to distinguish pattern from the background. Cognition
utilizes known symbols or letters according to the child's age. Child must identify and name
these symbols.
For visual acuity testing of nonverbal children are used preferential looking test. Tests
are based on the assumption that the child attracts a textured pattern and follows it. Teller
cards are the most used of these tests. It consists of black and white stripes of varying widths
on the gray surface. The child should fix this pattern and the width of the narrowest stripes
that child still recognizes determines level of vision.
Another objective technique that we can detect visual function of nonverbal children is
visual evoked potentials - VEP. This is electrophysiological method in which we detect visual
stimuli from surface electrodes placed on the occipital part of the skull.
We can examine visual acuity subjectively and more precisely in children about three
years. Grating acuity method is used, which is based on the assumption that the child already
knows and names different symbols and pictures. The size of symbols decreases
logarithmically similarly to the optotypes. Lea and Kay picture tests belong to this group, but
we can use Pflüger hooks or Landolt rings too. Older children can read optotypes with
numbers or letters.
Cycloplegia
We need to eliminate the influence of accommodation for a correct diagnosis of
refractive errors in children and so we use cycloplegics. These eye drops act as
parasympatholytics on the autonomic nervous system. Parasympaticus innervates the
pupillary sphincter and ciliary muscle. Application of cykloplegics blocks muscarinic receptors
and this leads to mydriasis and cycloplegia. Atropine and cyclopentolate (Cyclogyl) belong to
the group of cycloplegic drugs. Required dose of drugs depends on the color of the iris.
Methodology of the work
In my thesis I deal with differences in refraction of children before and after using
cycloplegia. Data for the research were obtained from the medical records of orthoptic
VII. CSKO 20. 10. 2016
16
patients from archive of Mgr. Andrea Jeřábková. The total number of subjects in research is
around a one hundred at the age of 2 to 15 years. These patients have ortoptic status, so the
most of them are hyperopic and only few of them are myopic. Cyclogyl (1%) was used to
cycloplegia and refraction was examined objectively by autorefractometer.
Hypotheses and partial results
The first hypothesis is: The value of myopia decreases, but the value of hyperopia
increases with cycloplegia. My partial results confirm this, although the fact, that most
patients are hyperopic, may lead to a distortion of the results. For comparison, I mention study
of influence of 1% cyclopentolate on the refractive status of children aged 4 to18 years from
Chinese province of Shandong. Auto-refractometry was performed before and after inducing
cycloplegia and data of 5999 children were included in the statistical analysis. The average
difference between cycloplegic and non-cycloplegic refractive error was 0,78 +/- 0,79 D. 66,4%
of all eyes with non-cycloplegic myopia remained myopic after cycloplegia while the remaining
eyes became emmetropic (18,0%) or hyperopic (15,7%) under cycloplegia. It means that noncycloplegic
refractometric measures lead to a misclassification of refractive error in a
significant proportion of children.
Next hypothesis deals with the correlation of age and difference between noncycloplegic
and cycloplegic refraction. I suppose that the difference between measurements
will decrease with increasing age. I can’t confirm this for now, because of uneven age
distribution of the sample. I relied on the Australian population study, which compared preand
postcycloplegic autorefraction in two separate age samples. Autorefraction was
performed before and after cycloplegia, using 1% cyclopentolate, in the right eyes of 2 233
12-year-old and 210 6-year-old children. The mean spherical equivalent difference between
these measures was 0,84 D in the 12-year-old children and 1,18 D in the 6-year-old children.
Precycloplegic autorefraction substantially overestimated the proportion of children with
myopia, misclassifying 17,8% aged 12 years and 9,5% aged 6 years. Conversely, precycloplegic
autorefraction didn‘t detect moderate to high hyperopia in 2,28% of 12-year-olds and 17,14%
of 6-year-olds. These results reinforce the importance of using cycloplegia in children up to
age 12 years.
The last hypothesis focuses on change of the axis of astigmatism depending on
cycloplegia. I assume that the cylindrical axis shouldn’t change by more than 10 ° in 80% of
cases, because in my opinion the removal of accommodation doesn’t affect the axis of
astigmatism. My partial results confirm this hypothesis for now.
VII. CSKO 20. 10. 2016
17
Resources
Kuchynka, P. Oční lékařství. 1.vyd. Praha: Grada, 2007, 768 s. ISBN 9788024711638.
Rutrle, M. Přístrojová optika: učební texty pro oční optiky a oční techniky, optometristy a
oftalmology. 1. vyd. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví, 2000, 189
s. ISBN 8070133015.
Papcunová, R. Korekce refrakčních vad dětského věku: bakalářská práce. Brno: Masarykova
univerzita, Fakulta lékařská, Katedra optometrie a ortoptiky, 2014, 64 s. Vedoucí bakalářské
práce Mgr. Matěj Skrbek.
Jeřábková, A. Stanovení zrakových funkcí u dětí. Česká oční optika. 2014, 55(4), 34-35. ISSN
1211-233X.
Fotedar, R. et al. Necessity of Cycloplegia for Assessing Refractive Error in 12-Year-Old
Children: A Population-Based Study. American Journal of Opthalmology. 2007, 144, 307-309.
HU, Y. Y. et al. Effect of Cycloplegia on the Refractive Status of Children: The Shandong
Children Eye Study. 2015. PLoS ONE 10(2): e0117482. doi:10.1371/journal.pone.0117482.
VII. CSKO 20. 10. 2016
18
Výtěžnost využití Pentacamu při diagnostice keratokonu
Autor: Bc. Ivo Hlinomaz
Školitel: Mgr. Ondřej Vlasák
Úvod
Práce je rozdělena na tři části. V první pojednávám o keratokonu. Dále se zmiňuji o
přístroji Pentacam (firma Oculus). Ve třetí části je pojednáno o diagnostice keratokonu.
Keratokonus
Keratokonus je nezánětlivé, často bilaterální, degenerativní ektatické onemocnění
rohovky, při kterém rohovka postupně zaujímá nepravidelný kónický tvar. Hlavními
charakteristickými znaky keratokonu jsou: centrální či paracentrální ztenčování stromatu
rohovky, apikální protruze, myopie, a později nepravidelný astigmatismus. Důsledkem těchto
příčin je postupné zhoršení jednak kvantity, ale zároveň kvality vidění.
Onemocnění se často začíná projevovat v pubertálním věku. Není to ale pravidlem, tudíž
může k manifestaci onemocnění dojít v jakémkoli věku. Tato ektázie často vzniká nejprve na
jednom oku, před tím, než se manifestuje na oku druhém. Dle Leea pouze 4% pacientů má
unilaterální keratokonus, navíc toto číslo stále klesá díky moderním přístrojům, které dokáží
odhalit keratokonus v subklinických stádiích. [1,2]
Prevalence onemocnění se pohybuje mezi 1/1000 až 2,3/100, ale i více. Zajímavé je, že
hodnoty prevalence se liší podle místa, kde se měření uskutečňuje. Například na Novém
Zélandu a v Saudské Arábii je výskyt onemocnění vyšší. Může to být dáno zvýšenou expozicí
pacientů na UV záření. Incidence neboli počet nově nemocných za rok je asi 1/2000.
Přesná etiologie keratokonu je doposud neznámá, avšak existuje mnoho faktorů, které
se na vzniku a progresi mohou podílet. Jde tudíž o onemocnění s multifaktoriální etiologií.
Mezi rizikové faktory vzniku keratokonu patří:
Věk - Zřídka kdy je onemocnění kongenitální. Počátek onemocnění je nejčastěji v
pubertě a rozvíjí se do třetí nebo čtvrté dekády života. V tomto věku obvykle stagnuje.
Vliv hormonů - Z důvodu, že keratokonus často vzniká v pubertě a progreduje v
těhotenství, je možnou příčinou také vliv některých hormonů. Tato problematika se
stále nachází v teoretické rovině a zatím nebyla přímo dokázána. Existují však studie,
které se tímto tématem zabývají. Spoerl et al. studovali vliv estrogenů na
biomechanické vlastnosti rohovky. Do prasečích rohovek byl po dobu sedmi dnů
inkubován beta - estradiol. Ve srovnání s fyziologickými prasečími rohovkami bez
aplikovaného estradiolu došlo ke snížení tvrdosti rohovky o 36%. To může mít ve
výsledku vliv na vznik rohovkové ektázie.
Vliv mnutí očí
Atopie
VII. CSKO 20. 10. 2016
19
Systémová onemocnění - Prevalence keratokonu v u osob postižených Downovým
syndromem je 10x - 300x vyšší, než u globální populace. Dále jsou v souvislosti s
keratokonem uváděny prolaps mitrální chlopně, Ehler - Danlosův syndrom a další. [1]
Symptomy
Z pohledu refrakční vady nejčastěji v počátečním stadiu nacházíme myopii a pravidelný
astigmatismus. S postupnou progresí onemocnění se astigmatismus stává nepravidelným.
Symptomy lze rozdělit na ty subjektivní a intersubjektivní (vnější).
Subjektivní symptomy se mění v závislosti na závažnosti onemocnění. V subklinickém
stádiu nemusí mít pacient žádné subjektivní obtíže. Prvním symptomem bývá nejčastěji
nestálné rozmlžené vidění. Jak keratokonus progreduje, může pacient pozorovat haló efekty
kolem světel a jeden či více “duchů” kolem fokusovaných předmětů. Tento jev se nazývá
“ghosting” (monokulární di-, tri-, polyopie). Pacient ho nejčastěji pozoruje na vysoce
kontrastních plochách (zářící měsíc na tmavé obloze nebo světla aut). Pacient může dále trpět
fotoaverzí - zvýšenou citlivostí na světlo. Tyto subjektivní symptomy mohou být doprovázeny
pocitem tlaku v postiženém oku, případně jeho bolestí.
Stejně jako subjektivní symptomy, tak i ty intersubjektivní závisí na závažnosti
onemocnění. U mírného či pokročilého keratokonu může být přítomen jeden či více
následujících klinických rysů.
Tenčení rohovkového stromatu - centrální či paracentrální, nejčastěji inferiorní či
inferiorně - temporální
Vyklenutí rohovky (ektázie)
Fleischerův prstenec - částečná či celá kružnice hemosiderinu (zásobní forma železa)
nacházející se u báze konu.
Vogtovy strie - jemné linie v zadním stromatu a na Descemetově membráně, které
bývají paralelní k nejstrmější ose konu. Vznikají nejspíš z důvodu mechanického
stlačování Descemetovy membrány a kolagenních lamel stromatu. Při vyvinutí
externího tlaku na oko strie přechodně zmizí.
Munsonův znak - vyboulení spodního víčka do tvaru V z důvodu přítomnosti konu,
které nastává při pacientově pohledu dolů
Jizvení rohovky - může vznikat v předním stromatu z důvodu protahování stromálních
vláken, případně kvůli rupturám Bowmannovy vrstvy.
Rizzutiho znak - jasný odraz světla na nazální straně limbu při fokusaci osvětlovacího
paprsku na stranu temporální
Změny na nervech rohovky - může docházet ke zvýraznění rohovkových nervů čizměně
jejich průběhu do podoby meandrovitých vlnovek. Zároveň se může rohovka z důvodu
přítomnosti keratokonu stát méně senzitivní. [1,2,3]
Pentacam
Theodor Scheimpflug popisoval zobrazovací podmínky, které umožňovaly pozorovat
objekty s minimálním zkreslením obrazu a maximálníhloubkou ostrosti. V normálním případě,
například ve fotoaparátu, je rovina obrazu rovnoběžná s rovinou objektivu. Scheimpflugův
VII. CSKO 20. 10. 2016
20
princip je založen na faktu, že rovina obrazu nenírovnoběžná s rovinou objektivu. Zároveň ani
rovina obrazu nenírovnoběžná s ostatními rovinami a všechny se protínajíve Scheimpflugově
bodě. Toto uspořádáníumožňuje získávat snímky s většíhloubkou ostrosti.
Přístroj Pentacam vyráběný firmou Oculus využívá Scheimpflugova principu. Pentacam
obsahuje dvě kamery a štěrbinové osvětlení (zdroj světla rotuje spolu se Scheimpflugovou
kamerou kolem optické osy přístroje). Kamera, která se nachází ve středu přístroje, snímá
neustálé pohyby oka, kontroluje centraci a měří velikost zornice. Druhá kamera, která se
nacházína okraji přístroje, vycházíze Scheimpflugova principu. Rotuje kolem oka a zachycuje
sekční snímky předního segmentu, kterých je 25 – 50, podle druhu měření. Takto získané
snímky jsou nepatrně zkreslené. Toto zkreslení je způsobeno lomem světla na površích
rohovky a čočky. Digitálníúprava dat tato zkresleníspraví. Z každého snímku je generováno
500 elevačních datových bodů, a to znamená až 25000 měřených bodů při jednom vyšetření.
Vyšetření trvá pouze 2 sekundy. Informace z obou kamer jsou odeslány do počítače, který
pomocímatematického vyhodnocenívypočítá přesná data, která umožnínásledné zobrazení
rohovkových parametrů, topografických map (přední i zadní plocha rohovky), elevačních map
(přední i zadní plocha rohovky), pachymetrie, rohovkových aberací, denzitometrie čočky,
zobrazení předního segmentu oka, Scheimpflugův snímek, tomografii rohovky, 3D simulaci
fakické IOL, Belin/Ambrosio zobrazení a Holladay zobrazení. [4,5]
Diagnostika keratokonu
Při nalezení více než jednoho z následujících kritérií lze považovat rohovku za suspektní
či keratokonickou (v závislosti na naměřených hodnotách).
Pomocí sagitální mapy:
strmá K > 48 D
K max > strmá K o více než 1 D
S - I rozdíl > 2,5 D (pokud je horní část strmější - rozdíl keratometrických hodnot mezi
horní a dolní částí rohovky v 5mm průměru)
I - S rozdíl > 1,5 D (pokud je dolní část strmější - rozdíl keratometrických hodnot mezi
dolní a horní částí rohovky v 5mm průměru)
Astigmatismus > 6 D (na přední nebo zadní ploše rohovky)
Astigmatismus proti pravidlu je suspektní
Pomocí pachymetrické mapy:
Kónický tvar
S - I rozdíl > 30 µm (rozdíl pachymetrie horní části rohovky a dolníčásti v 5mm průměru)
Nejtenší místo < 470 µm
Rozdíl tloušťky v nejtenších místech na obou očích > 30 µm
Pomocí elevační mapy:
Isolovaný “ostrůvek” (BFS mód)
Hodnoty > 12 µm v 5mm zóně na přední ploše rohovky (BFTE mód)
Hodnoty > 12 µm v 5mm zóně na zadní ploše rohovky (BFTE mód)
VII. CSKO 20. 10. 2016
21
Belin/Ambrosio zobrazení kombinuje elevační a pachymetrická data. Na grafu “corneal
thickness spatial profile” (CTSP) lze pozorovat průměrné hodnoty tloušťky rohovky od
nejtenčího místa k limbu měřené v koncentrických kružnicích se zvyšujícím se průměrem o 0.4
mm. Pacientova rohovka je znázorněna červenou barvou a měla by kopírovat průběh křivek
normativních dat. Dalším grafem je procentuální progrese pachymetrie (PTI). Náhlá změna
křivek u obou grafů může poukazovat na keratokonus. Index pachymetrické progrese by měl
být nižší než 1,2. Na levé straně se nachází 3 elevační mapy přední plochy rohovky a 3 elevační
mapy zadní plochy. První z nich jsou klasické elevační mapy získané pomocí nejlepšího
sférického referenčního tělesa. Na dalších elevačních mapách je případný konus zvýrazněn (do
výpočtu nejlepšího sférického referenčního tělesa není zahrnuta 4mm zóna kolem nejtenčího
místa na rohovce - díky tomu se konus jeví výraznější). Na třetích elevačních mapách je
zobrazen rozdíl předchozích dvou map. Tato mapa zobrazuje pouze tři barvy. Zelená - typická
pro fyziologické rohovky, žlutá - rohovka spadá do suspektní kategorie, červená - typická pro
pacienty s keratokonem. [1,6]
Závěr
Vyšetření rohovky na pentacamu je v současné době považováno za zlatý standard pro
diagnostiku ektatických onemocnění rohovky zvláště pak keratokonu. Správné snímání a
posouzení jednotlivých paramterů rohovky, indexů a Belin Ambrosiho zobrazení umožní jak
diagnostiku, tak sledování vývoje parametrů v čase, což umožní přesné sledování vývoje
onemocnění s možností včasnho zahájení léčby.
Zdroje
[1] Barbara, A. Textbook on Keratoconus: new insights. New Delhi: Jaypee-Highlights Medical
Publishers, 2012. ISBN 9789350254042.
[2] Keratoconus symptoms. National Keratoconus Foundation [online]. [cit. 2016-06-29].
Dostupné z: http://www.nkcf.org/keratoconus-symptoms-and-diagnosis/
[3] Wong, T. Y. The ophthalmology examinations review. New Jersey: World Scientific, 2001.
ISBN 981-02-4400-2.
[4] Sinjab, M. M. Corneal topography in clinical practice (Pentacam system): basics and clinical
interpretation. 2nd ed. New Delhi: Jaypee Bros. Medical Pub, 2012. ISBN 9350255758.
[5] Celá, N. Pentacam a jeho možnosti. Brno, 2014. Bakalářská práce. Masarykova univerzita,
Lékařská fakulta. Vedoucí práce Sylvie Petrová. Dostupné z:
.
[6] Sinjab, M. M. Keratoconus: when, why and why not. New Delhui: Jaypee Brothers Medical
Publishers, 2012. ISBN 9350259222.
VII. CSKO 20. 10. 2016
22
The use of Pentacam in the diagnosis of keratoconus
Author: Bc. Ivo Hlinomaz
Supervisor: Mgr. Ondřej Vlasák
Introduction
The work is divided into three parts. At first I write about keratoconus. Then I mention
the device Pentacam (Oculus). The third part deals with the diagnosis of keratoconus.
Keratoconus
Keratoconus is a noninflammatory, often bilateral, ectatic degenerative corneal diseas
in which the cornea progressively occupies irregular conical shape. The main characteristics of
keratoconus are: central or paracentral thinning of the corneal stroma, apical protrusion and
myopia, irregular astigmatism later. The consequence of these causes is a gradual worsening
of quantity, but also quality of vision.
The disease often begins to manifest in the adolescent age. But it is not a rule, therefore,
may be a manifestation of the disease at any age. This ectasia often arises firstly on one eye,
before it manifests on the second eye. According to Lee, only 4% of patients have unilateral
keratoconus, moreover this number is steadily declining due to modern devices that can
detect subclinical stages of keratoconus. [1,2]
Prevalence of the disease varies between 1/1000 to 2.3 / 100, or even more.
Interestingly, the prevalence values vary depending on where the measurement takes place.
For example, New Zealand and Saudi Arabia has a higher incidence of disease. This may be
due to the increased exposure of patients to UV radiation. The incidence (the number of new
patients per year) is about 1/2000.
The exact etiology of keratoconus is still unknown, but there are many risk factors that
can partake in the uprise and progression. It is thus a disease with multifactorial etiology.
Among the risk factors for keratoconus include:
Age – Rarely it is a congenital disease. The onset of the disease most commonly
develops during puberty, and evolves into the third or fourth decade of life. In this age
usually it usually stagnates.
The influence of hormones - the reason that keratoconus often occurs in puberty and
progresses during pregnancy is a possible cause of the influence of hormones. This
issue is still theoretical and has not been directly proven. However, there are studies
that deal with this issue. Spoerl et al. studied the effect of estrogen on the
biomechanical properties of the cornea. To pig corneas was for seven days applied
beta - estradiol. In comparison with the physiological pigs corneas without applied
estradiol, corneal hardness decreased by 36%. This may affect the formation of corneal
ectasia.
The effect of rubbing your eyes
VII. CSKO 20. 10. 2016
23
Atopy
System Diseases - Prevalence of Keratoconus in people affected by Down syndrome is
10x - 300x higher than in the global population. Furthermore, in connection with
keratoconus are usual mitral valve prolapse, Ehler - Danlos syndrome, and others. [1]
Symptoms
From the viewpoint of refractive error we often find at an early stage myopia and regular
astigmatism. With the gradual progression of the disease becomes irregular astigmatism. The
symptoms can be divided into those subjective and intersubjective (external).
Subjective symptoms varies depending on the severity of the disease. In the subclinical
stage, the patient may have no subjective complaints. The first symptom is usually unstable
blurry vision. As keratoconus progresses, the patient may see halos around lights, and one or
more "ghosts" around the focussed subjects. This phenomenon is called "ghosting"
(monocular di-, tri-, multiple vision). Patient frequently sees it on high contrast areas (shining
moon on a dark sky lights or cars). The patient may also suffer from photoaversion - increased
sensitivity to light. These subjective symptoms may be accompanied by a feeling of pressure
in the affected eye, or his pain.
Intersubjective symptoms also depend on the severity of the disease. For moderate or
advanced keratoconus may be present one or more of the following clinical features.
Thinning of the corneal stroma - central or paracentral, mostly inferior or inferiorly -
temporal
The bulge of the cornea (ectasia)
Fleischer’s ring - partial or full circle of hemosiderin (storage form of iron) located at
the base of the cone.
Vogt's striae - fine lines in the posterior stroma and Descemet’s membrane which are
parallel to the steepest axis of the cone. They probably arise due to mechanical
compression of Descemet’s membrane and the collagen lamellae of the stroma. When
external pressure is applied on the eye striae temporarily disappear.
Munson’s sign - bulging lower eyelid to V-shape due to the presence of cone, which
occurs when the patient looking down
Scarring of the cornea - can occur in the anterior stroma due to stretching of stromal
fibers, possibly due to ruptures of Bowmann’s layer.
Rizzuti’s sign - a clear reflection of light on the nasal side limbus while focusing the
illuminating beam on the temporal side
Changes of the corneal nerves – the nerves can be highlited or changed into a
meandering wavy lines. At the same time the cornea, due to the presence of
keratoconus, become less sensitive. [1,2,3]
Pentacam
Theodor Scheimpflug was describing imaging the conditions that allow to observe
objects with minimal image distortion and maximum depth of field. In the normal case, such
as in the camera image plane is parallel to the plane lens. Scheimpflug’s principle is based on
VII. CSKO 20. 10. 2016
24
the fact that the image plane is not parallel to the plane lens. Simultaneously the image plane
is not parallel to other planes and all intersect in Scheimpflug’s point. This arrangement
enables to obtain images with greater depth of field.
The device Pentacam, manufactured by Oculus, uses Scheimpflug’s principle. Pentacam
includes two cameras and slit illumination (light source rotating together with the
Scheimpflug’s camera around the optical axis of the device). The camera, which is located in
the center of the instrument captures the eye movements, controls the centering and
measures pupil size. The second camera, located on the edge of the device is based on
Scheimpflug principle. Rotates around the eye and captures sectional images of the anterior
segment, which is 25 to 50, according to the type of measurement. These obtained images are
slightly distorted. This distortion is caused by the refraction of light on the surfaces of the
cornea and lens. Digital editing fixes these distortions. Out of each image is generated 500
elevation data points, which means up to 25 000 measurement points in one examination.
Examination takes only 2 seconds. Information from both cameras are sent to a computer that
uses a mathematical evaluation calculates the exact data that allows subsequent display of
corneal parameters, topographic maps (front and back surface of the cornea), elevation maps
(front and back surface of the cornea), pachymetry, corneal aberrations, lens densitometry,
view of the anterior segment of the eye, Scheimpflug’s image, corneal tomography, 3D
simulation of phakic IOL, Belin / Ambrosio display and the Holladay display. [4,5]
Diagnosis of keratoconus
When more than one of the following criteria is found it may be considered as
keratoconic cornea or a case of suspicion (depending on the measured values).
Using sagittal maps:
steep K-reading > 48 D
K max > steep K by more than 1 D
S - I difference > 2.5 D (if the upper part is steeper - keratometric difference values
between the upper and lower parts of the cornea in a 5 mm diameter)
I – S difference > 1.5 D (if the lower part is steeper - keratometric difference values
between the upper and lower parts of the cornea 5 mm in diameter)
Astigmatism > 6 D (on the front or rear surface of the cornea)
Astigmatism against the rule is suspicious
Using pachymetric maps:
The conical shape
S - I difference of > 30 µm (differential pachymetry top of the cornea and the lower
part 5 mm diameter)
Thinnest location < 470 µm
The difference in the thickness of the thinnest points on both eyes of > 30 µm
Using elevation maps:
The isolated "island" (BFS mode)
The values of > 12 µm within the central 5mm on the anterior elevation map (BFTE
mode)
VII. CSKO 20. 10. 2016
25
The values of> 12 µm within the central 5mm on the posterior elevation map (BFTE
mode)
Belin / Ambrosio display combines elevation and pachymetry data. On the chart "corneal
thickness spatial profile" (CTSP) could be observed average values of corneal thickness from
the thinnest location to limbus measured in concentric circles with increasing diameters by
0.4 mm. The patient's cornea is shown red and should copy the curves of normative data. The
next chart is the percentage thickness increase (PTI). The sudden change of curves on both
graphs can indicate keratoconus. Pachymetric progression index should be less than 1.2. On
the left side there are three anterior elevation maps and three posterior elevation maps. The
first of these are classic elevation maps obtained by using the best fit sphere. On the middle
elevation maps are displayed potential highlighted cone (to calculation of the best spherical
reference body is not included 4 mm zone around thinnest point on the cornea - because of
this the cone appears highlighted). On third elevation maps is displayed the difference of the
previous two maps. This map shows only three colors. Green - typical physiological cornea,
yellow - cornea falls into the category of suspect, red - typical for patients with keratoconus.
[1,6]
Conclusion
Examination of cornea with Pentacam is currently considered as the gold standard for
the diagnosis of ectatic corneal diseases, especially keratoconus. Proper measuring and
assessing individual corneal parameters, indices and Belin/Ambrosio display enable both
diagnosing and monitoring the progression of the parameters over time, which enables
accurate monitoring of the development of disease with early treatment initiation.
Resources
[1] Barbara, A. Textbook on Keratoconus: new insights. New Delhi: Jaypee-Highlights Medical
Publishers, 2012. ISBN 9789350254042.
[2] Keratoconus symptoms. National Keratoconus Foundation [online]. [cit. 2016-06-29].
Dostupné z: http://www.nkcf.org/keratoconus-symptoms-and-diagnosis/
[3] Wong, T. Y. The ophthalmology examinations review. New Jersey: World Scientific, 2001.
ISBN 981-02-4400-2.
[4] Sinjab, M. M. Corneal topography in clinical practice (Pentacam system): basics and clinical
interpretation. 2nd ed. New Delhi: Jaypee Bros. Medical Pub, 2012. ISBN 9350255758.
[5] Celá, N. Pentacam a jeho možnosti. Brno, 2014. Bakalářská práce. Masarykova univerzita,
Lékařská fakulta. Vedoucí práce Sylvie Petrová. Dostupné z:
.
[6] Sinjab, M. M. Keratoconus: when, why and why not. New Delhui: Jaypee Brothers Medical
Publishers, 2012. ISBN 9350259222.
VII. CSKO 20. 10. 2016
26
Statická versus dynamická zraková ostrost
Autor: Bc. Pavla Hrabalová
Školitel: Mgr. Simona Bramborová, DiS.
Úvod
Statická zraková ostrost není v podstatě nic jiného, než vizus pacienta měřeného
v optometrickém či oftalmologickém pracovišti za pomoci klasických optotypových tabulí –
dnes nejspíš nejčastěji používaných LCD optotypů. Jde o zjištěnízrakové ostrosti, kdy není mezi
pacientem a optotypovým znakem žádný pohyb. Označení „statická“ se běžně nepoužívá,
protože ještě donedávna se o žádném jiném typu zrakové ostrosti nemluvilo. V poslední době
se ale můžeme setkat s pojmem dynamická zraková ostrost, což ve zkratce znamená měření
zrakové ostrosti, kdy dochází mezi pacientem a optotypovým znakem k pohybu. Oba typy však
mají spoustu společného. Například jejich zjišťování je měřením subjektivním, tedy čistě
závislé na aktivitě pacienta – na jeho zrakových funkcích a u dynamického měření také na
reakčních funkcích pacienta.
Dále při měření zrakové ostrosti, a to jak statické tak dynamické, vycházíme z rozlišovací
schopnosti oka, která je definována jako schopnost oka rozeznat dva body v předmětovém
prostoru odděleně = tzv. minimum separabile. Předpokladem pro tuto skutečnost je, aby
obrazy takovýchto dvou bodů na sítnici byly odděleny alespoň jedním čípkem, na který se
promítne mezera mezi nimi. Z výpočtů vyplývá, že nejmenší úhlová vzdálenost dvou ještě
rozlišitelných bodů je 0,0003 rad, což je rozteč odpovídající tangentě jedné úhlové minuty (1´).
Tento úhel je základní veličinou pro hodnocení zrakové ostrosti a také pro konstrukci
optotypů.
Dynamická zraková ostrost
Předpokladem pro měření dynamické zrakové ostrosti je kvalitní statická zraková
ostrost, ke které je mimo jiné zapotřebí průchodnosti optického systému oka a správné funkce
a spojení fotoreceptorů se zrakovými korovými centry. Z vnějších vlivů můžeme jmenovat
kontrast samotných optotypových tabulí, intenzitu osvětlení či barvu světla. Dynamické vidění
vyžaduje vedle všech předpokladů pro statické vidění také správnou funkci motorického
mechanismu – tedy konjugované pohyby očí, hlavy a těla, který zajistí udržení obrazu
pohybujícího se předmětu na sítnici. Dále je dynamická zraková ostrost opět ovlivněna i
okolním prostředím, a především rychlostí pohybu daného znaku či délkou jeho expozice. Při
nižších rychlostech jsou hodnoty dynamické zrakové ostrosti v korelaci se statickou, ale při
vyšších rychlostech klesá rozlišovací schopnost a tudíž i dynamická zraková ostrost.
Vyšetření dynamické zrakové ostrosti může probíhat dvěma základními způsoby. První
způsob probíhá při pohybu hlavy vyšetřovaného za použití klasických statických optotypových
tabulí. Druhým způsobem je usazení pacienta, kterému jsou promítány pohybující se znaky.
Oba druhy měření mají však ještě svá další specifika, jako jsou například směr a způsob pohybu
VII. CSKO 20. 10. 2016
27
jak vyšetřované osoby (pohyb navozený vyšetřujícím, pohyb hlavy za chůze), tak použitých
znaků (od/k vyšetřovanému, horizontální, rotační).
Test dynamické zrakové ostrosti
Jelikož se v České republice dynamická zraková ostrost běžně neměří mimo
specializovaná pracoviště zabývající se vizuální či sportovní optometrií, nesetkáme se s
žádným standardizovaným testem k jejímu měření. Test dynamické zrakové ostrosti je pouze
experimentálně sestavený test podle původního návrhu doktorky Krasňanské a kolektivu.
Výchozím bodem k měření je zjištění naturálního vizu a v případě jeho poklesu také
vykorigování ametropie klasickou metodou refrakce. Vyšetření probíhá většinou tedy pouze
binokulárně, a to s nejlepší korekcí, případně s vlastní korekcí (u emetropa bez korekce). Při
tomto testování nedochází k pohybu pacienta, ale pouze k simulovanému pohybu znaku na
obrazovce notebooku. Jako nejvhodnější znak se pro tento typ měření ukázal Landoltův kruh,
který je považován za nejobjektivnější ze všech znaků vůbec. Na výšku má tento znak velikost
pět jednotek („D“), výřez a tloušťka znaku zaujímají velikost jedné jednotky („d“) a lze jej
nabídnout v osmi různých polohách – dvou horizontálních, dvou vertikálních a čtyřech
šikmých. Jeho velikost se odvíjí od pozorovací vzdálenosti („a“), která je v tomto případě
stanovena na 3 m, a především od hodnoty požadované zrakové ostrosti („VA“). Znak se
zvětšuje z hodnoty VA = 2 až po VA = 0,1 lineárně spojitě, čímž dochází k simulaci pohybu
směrem k vyšetřovanému. Rychlosti simulovaného pohybu jsou nabídnuty dvě – v = 20 m/s
(72 km/h) a poloviční hodnota, tedy v = 10 m/s (36 km/h).
Výpočet velikosti samotného znaku a jeho detailů v jednotlivých polohách vychází ze
závislosti VA na zorném úhlu pozorování podle vzorce ω = 1/VA , kde výsledný zorný úhel
dostáváme v úhlových minutách. Další nezbytně nutnou veličinou pro výpočet „d“ – velikosti
kritického detailu, je hodnota „a“ – vyšetřovací vzdálenost (obě v metrech). Dle vzorce d = a ∙
tg ω vypočítáme velikost detailu znaku, ze které po vynásobení pěti (ze vzorce D = 5 ∙ d)
dostaneme výslednou výšku celého znaku pro danou hodnotu VA. Výsledná hodnota
dynamické zrakové ostrosti pak závisí na tom, v jakém časovém okamžiku je test kliknutím
tlačítka bezdrátové myši pozastaven. Jelikož je simulovaná rychlost pohybu znaku poněkud
vysoká a reakční časy člověka ani techniky nejsou úplně zanedbatelné, je zapotřebí spustit test
ještě pozpátku, kdy pacient určuje kliknutím okamžik, kdy se mu znak již rozostří. Obě hodnoty
poté zprůměrujeme a teprve tento výsledek lze považovat za hodnotu dynamické zrakové
ostrosti. Ověření lze provést stejným způsobem za použití jiné polohy znaku.
Závěr
Je jasné, že simulované podmínky v místnosti nikdy plně nenahradí situaci z reálného
života, přesto je měření dynamické zrakové ostrosti vyšetření, které by v praxi mohlo najít
uplatnění. Dynamické vidění je totiž zapojeno nejen při každodenních činnostech, jako je
například řízení, ale třeba i při sportu. Ve sportovní optometrii se různých experimentálních
metod k měření dynamické zrakové ostrosti již využívá, protože trenéři jsou si vědomi, že
dynamická zraková ostrost vypovídá o kvalitě vidění přesněji nežli statické měření. Vhodné by
tak bylo využít této metody například při měření zrakové ostrosti žadatelů o řidičské oprávnění
nebo držitelů řidičského oprávnění vyššího věku, u kterých je právě přezkoumávána
VII. CSKO 20. 10. 2016
28
způsobilost k řízení. První by však měla být zajištěna určitá norma k měření dynamické zrakové
ostrosti, abychom byli schopni správně vyhodnocovat a porovnávat výsledky.
Zdroje
Erickson, G. B. Sports vision: vision care for the enhancement of sports performance. Oxford:
Butterworth-Heinemann, c2007, xi, 308 p. ISBN 07-506-7577-2.
Hrabalová, P. Metodika vyšetření dynamické refrakce. Brno: Masarykova Univerzita. Lékařská
fakulta. Katedra optometrie a ortoptiky,2015. 56 s. Vedoucí práce Mgr. Jitka Krasňanská, Ph.D.
Pivodová, L. Principy vizuální optometrie využívané při přípravě vrcholových sportovců. Brno:
Masarykova Univerzita. Lékařská fakulta. Katedra optometrie a ortoptiky, 2015. 72 s. Vedoucí
práce Mgr. Jitka Krasňanská, Ph.D.
VII. CSKO 20. 10. 2016
29
Static versus dynamic visual acuity
Author: Bc. Pavla Hrabalová
Supervizor: Mgr. Simona Bramborová, DiS.
Introduction
Static visual acuity is basically nothing more than the patient's visual acuity measured in
optometry or ophthalmological department with the help of classic optotype boards nowadays
probably the most often used LCD optotypes. It is the finding out the visual acuity,
while between the patient and optotype sign is no movement. The signification "static" is not
commonly used because until recently anybody didn´t speak about any other type of visual
acuity. Lately however we can encounter the concept of dynamic visual acuity, that in short
means a measurement of visual acuity, when between the patient and optotype character
occurs any movement. Both types have a lot in common. For example, their detection is
subjective measuring, therefore purely dependent on the activity of the patient - on his visual
functions and also on the reaction function of the patient during dynamic measurement.
Additionally measuring of visual acuity, both static and dynamic, that is based on
resolution of the eye, is defined as the ability of the eye to distinguish two points in objective
space separately = so called minimum separabile. The prerequisite for this fact is that images
of these two points on the retina must be separated at least one cone, on which is projected
the gap therebetween. The calculations show that the smallest angular distance two still
distinguishable points is 0.0003 rad, which is a spacing corresponding to the tangent of one
arc minute (1'). This angle is a basic value for the evaluation of visual acuity as well as for the
construction of optotypes.
Dynamic visual acuity
A prerequisite for the measurement of dynamic visual acuity is good-quality static visual
acuity, which requires among others transparency of an eye optical system and correct
function and connection of photoreceptors with visual cortex centres. From external
influences we can nominate a contrast of test types, intensity of illumination or colour of light.
Dynamic vision requires besides all the prerequisites for static vision also correct function of
the motor mechanism – thus conjugate movements of the eyes, the head and the body, which
ensures maintenance of an image of moving subject in the retina. Furthermore, the dynamic
visual acuity is also affected by its background, especially by speed of the symbol´s movement
or by length of exposure. At lower speeds the dynamic visual acuity values are in correlation
with the static, but at higher speeds decreases eye resolution and therefore dynamic visual
acuity too.
Examination of dynamic visual acuity can be done in two basic ways. The first way is
investigation in motion of the examinant by using classic static test types. The second way is
the seating of the patient who is exposed to the moving symbols. Both types of measurement,
however, still have their different characteristics, such as the direction and way of movement
VII. CSKO 20. 10. 2016
30
of both – the investigated person (movement induced by examiner, head movement while
walking) and the symbols (from/to the examinant, horizontal, rotating movement, etc.).
Dynamic visual acuity test
Because in the Czech Republic is the dynamic visual acuity normally not measured
excepting specialized departments dealing with visual or sport optometry, we meet with no
standardised test for its measurement. The test of dynamic visual acuity is only a theoretical
proposal by the doctor Krasňanská et al.
The zero point for measurement is to determine the natural vision and in case of a
decline also adjusting of ametropia with classical method of refraction. Examination is usually
carried out only binocular, with best correction, possibly with its own correction (by the
emmetrope without correction). While this testing does not move the patient, but there is
only the simulated moving sign on laptop screen. As the best symbol for this type of
measurement has shown Landolt ring, which is considered to be the most objective of all the
symbol at all. The height of this character has a size of five units ("D"), the cut and thickness
of the character occupy the size of one unit ("d") and can be offered in eight different positions
- two horizontal, two vertical and four oblique. Its size depends on the viewing distance ("a"),
which was set in 3 m in this case, and especially on the value of the required visual acuity
("VA"). Character is increasing from the value VA = 2 up to VA = 0.1 linearly continuously,
thereby simulating motion toward investigated. Simulated movement speeds are offered two
- v = 20 m / s (72 km / h), and half the value, that is v = 10 m / s (36 km / h).
Calculating the size of the character and its details in the individual positions is based on
the dependence VA upon the viewing angle of observation by the formula ω = 1 / VA wherein
the resulting viewing angle brings in arc minutes. Another quantity necessary for the
calculation of "d" - size of the critical detail, is the value of "a" - investigative distance (both in
meters). According to the formula d = a tg ∙ ω we can calculate the size of symbol´s detail, and
after multiple by five (from the formula D = 5 ∙ d) we will get the final height of the entire
symbol for the given value of the VA. The final value of dynamic visual acuity then depends on
the moment of the pause by the wireless mouse button click. Because the simulated speed of
symbol´s movement is quite high and the reaction times of examinant or techniques are not
negligible, it is necessary to activate a test even backwards, where the patient determines the
moment of blurring the character again by the click. Both values are then averaged and then
this result can be considered as the value of dynamic visual acuity. Verification can be done in
the same manner using a different character position.
Conclusion
It is distinct, that simulated conditions can not fully replace situations from a real life,
nevertheless the dynamic visual acuity examination is a method which could find a use in
practice. Dynamic vision is not connected only in daily activities like driving, but even in sport
also. In sport optometry is nowadays used some experimental methods for measuring
dynamic visual acuity, because the trainers well know that dynamic visual acuity says much
more about the quality of vision than only the static measurement.It would be advisable to
include this method between the criteria for obtaining the driving eligibility, or at least
VII. CSKO 20. 10. 2016
31
between the criteria for retaining the driver's licence to the drivers in a greater age . First,
however, must be ensured a certain standard for this measurement, so we were able to
correctly evaluate and compare the results.
Resources
Erickson, G. B. Sports vision: vision care for the enhancement of sports performance. Oxford:
Butterworth-Heinemann, c2007, xi, 308 p. ISBN 07-506-7577-2.
Hrabalová, P. Metodika vyšetření dynamické refrakce. Brno: Masarykova Univerzita. Lékařská
fakulta. Katedra optometrie a ortoptiky,2015. 56 s. Vedoucí práce Mgr. Jitka Krasňanská, Ph.D.
Pivodová, L. Principy vizuální optometrie využívané při přípravě vrcholových sportovců. Brno:
Masarykova Univerzita. Lékařská fakulta. Katedra optometrie a ortoptiky, 2015. 72 s. Vedoucí
práce Mgr. Jitka Krasňanská, Ph.D.
VII. CSKO 20. 10. 2016
32
Změny akomodačně vergenčních vlastností v závislosti na
věku
Autor: Bc. Markéta Hrabovská
Školitel: Mgr. David Severa
Akomodačně vergenční vlastnosti vizuálního systému nám umožňuji vidět ostře
předměty na různé vzdálenosti. Akomodace zajišťuje vytvoření ostrého obrazu pozorovaného
předmětu a spolu s ní probíhají vergenční pohyby, které vyrovnávají postavení obou oči. Díky
vzájemné spolupráci akomodačního a vergenčního systému dochází ke spojení dvou obrazů v
jeden smyslový vjem – je tak zprostředkováno jednoduché binokulární vidění.
Akomodace
Akomodace je dynamický proces, při kterém se mění optická mohutnost systému oka
tak, aby byl pozorovaný předmět v proměnné předozadní vzdálenosti reálného předmětového
prostoru zobrazen ostře na sítnici. Rozlišujeme čtyři složky akomodace - složku tónickou,
proximální, reflexní a vergenční. Tonická složka akomodace je přítomna i bez přítomnosti
podnětu, je způsobena klidovým napětím ciliárního svalu. Proximální složka je navozena
představou vzdáleného předmětu. Reflexní složka je navozena rozmazaným obrazem a
zajišťuje sítnicové zaostření obrazu. Poslední složkou je složka vergenční, která může byt
spuštěna konvergencí na základě vztahu CA/C a je kontrolována fúzi.
CA/C poměr popisuje změnu konvergenčníakomodace na jednotku změny konvergence.
Udává, kolik dioptrii akomodujeme na 1 pD konvergence. Tento poměr nabývá hodnot 1:10.
V běžné praxi se neměří.
Akomodace a věk
Při narození není řasnaté tělísko plně vyzrálé a čočka je měkčí, než čočka dospělého
jedince. Akomodační pružnost se vyvíjí během prvních měsíců života a okolo čtvrtého měsíce
je přibližně srovnatelná s akomodací dospělého člověka. Vývoj ciliárního svalu a tím i
akomodace je ukončen zhruba ve 3 letech života. Během života se snižuje schopnost čočky
vyklenout se a tím zvýšit svoji optickou mohutnost, což se projeví vzdalováním blízkého bodu
akomodace od oka a poklesem akomodační amplitudy. K prvnímu poklesu dochází kolem 5.
roku života a nadále klesá přibližně o 0,3 D za rok. Pokles akomodační amplitudy v závislosti
na věku znázorňuje Duanova křivka. Dochází tak k fyziologické poruše akomodace –
presbyopií, jejíž první příznaky se objevují okolo 40. roka života. Existuje mnoho teorií, které
vysvětlují vznik presbyopie – pro názornost uvádím jen některé z nich.
VII. CSKO 20. 10. 2016
33
Obrázek 1: Duanova křivka
Hess-Gulstrandova teorie vysvětluje presbyopii jako důsledek věkem podmíněných
změn v čočce – velikost stahu ciliárního svalu, který je nutný pro navození dané akomodace,
zůstává se zvyšujícím se věkem stejná, pokud je toto množství v rámci limitu akomodační
amplitudy. Na rozdíl od ostatních teorií prosazuje názor, že při zvyšujícím se věku dochází
k nárůstu kontrakce ciliárního svalu až za hranici schopnosti čočky a jejího obalu na tento
nárůst reagovat.
Finchmanova teorie je podobná teorii Hess-Gullstranda. Prosazuje, že presbyopie je
důsledkem ztížené deformace čočky se zvyšujícím se věkem, ale pro maximální akomodaci je
požadována maximální kontrakce ciliárního svalu v kterémkoli věku.
Geometrická teorie předpokládá, že presbyopie je důsledkem změny velikosti a tvaru
čočky. Tato změna je příčinou toho, že napětí zonul působí více paralelně k povrchu čočky.
Změny v napětí zonul proto budou mít při akomodaci menší efekt na změnu tvaru čočky.
Extralentikulární teorie tvrdí, že přesbyopie je způsobena oslabením ciliárního svalu
nebo ztrátou elasticity zonul, ciliárního tělesa a choroidálních komponentů.
Vergence
Oční motilitu zajišťují 4 přímé – horní, dolní vnitřní a zevní přímý sval a 2 šikmé – horní a
dolní šikmý sval. Vergenci dělíme na volní a reflexní, kterou dále dělíme na tonickou,
proximální, akomodační a fúzní. Tonická udržuje paralelní postavení očí bez fúzních podmětů.
Proximální vergence je navozena vědomím blízkosti předmětu. Fúzní vergence je vyvolána
retinální disparitou a umožňuje jemné vergenční nastavení pohledových os. Akomodační
vergence je navozena akomodací, kde je akomodace podnětem pro konvergenci. Vztah mezi
akomodací a akomodační vergencí vyjadřuje poměr AC/A.
AC/A poměr popisuje změnu akomodační vergence při změně akomodace. Udává, o
kolik prizmatických dioptrií se změní akomodační vergence při změně hodnoty akomodace o
1 D. Za normální hodnoty jsou u gradientní metody výpočtu považovány poměry 2:1-4:1.
Jestli-že AC/A poměr nabývá vyšších hodnot, znamená to, že oči na danou velikost akomodace
konvergují více, než by měly. Naopak nižší AC/A poměr znamená, že u příslušné akomodace
dochází k menší konvergenci.
VII. CSKO 20. 10. 2016
34
Akomodačně vergenční mechanismus a věk
I když se vergenční vlastnosti s věkem téměř nemění, dochází vlivem snížení akomodační
schopnosti ke změně vztahu mezi akomodací a vergencí. Je tedy možné, že po nástupu
presbyopie je maximální akomodace provázena větším množstvím konvergence než
v předpresbyopickém věku. Aby tedy bylo zachováno binokulární vidění, bude kladen zvýšený
nárok na fúzní konvergenci.
Problematikou změny akomodačně vergenčních vlastností v závislosti na věku se
zabývalo více teorií a studií. Nedospěli však k jednotnému názoru a jejich výsledky se liší.
Některé teorie (Helmholz, Hess, Gullstrand) uvádí, že v každém věku je na vytvoření stejné
změny akomodace potřebná stejná práce ciliárního svalu a vztah mezi akomodací a vergencí
se s věkem nemění. Jiné teorie (Donders, Duane, Finchman a další) naopak usuzují, že tento
vztah se v průběhu života mění.
V důsledku předpokladu Hess-Gullstrandovy teorie, že úsilí ciliárního svalu, které je
potřebné k jednotkové změně akomodace se s věkem nemění, může mezi akomodací a
vergencí dojít ke dvěma situacím. Buď dojde ke snížení AC/A poměru s věkem kvůli snížení
akomodační konvergence, která je důsledkem snížení akomodace, anebo se AC/A s věkem
nemění, protože se akomodační konvergence a akomodace snižují proporcionálně.
Na druhé straně Duanne-Finchamova teorie konstatuje, že úsilí na vytvoření jednotkové
změny akomodace se s věkem zvyšuje. To znamená, že předpokládá, že se buď poměr AC/A
s věkem zvyšuje kvůli zvýšené akomodační konvergenci, anebo že se AC/A výrazně zvyšuje,
protože při zvyšování akomodační konvergence se zároveň snižuje akomodace.
Většina studiíse přiklání ke skutečnosti, že s věkem se poměr AC/A zvyšuje a poměr CA/C
se snižuje, čímž vyvracejí Hess-Gullstrandovu teorii. Některé výzkumy dále potvrzují reciproký
vztah mezi AC/A a CA/C poměrem, což znamená, že se zvyšujícím se věkem se AC zvyšuje do
takové míry, do které se CA snižuje. Na druhé straně jiné studie tento vztah nepotvrdili, ale
přiznávají, že mírné lineární propojení mezi AC/A a CA/C poměry existuje. V odborné literatuře
se však běžně setkáváme s tvrzením, že poměry AC/A a CA/C jsou na sobě zcela nezávislé.
Zdroje
Pluháček, F., Musilová, L. Akomodace a vergence [online], Optometrie UP [cit. 2016-06-20].
Diplomová, dostupné z:
Ouhelová, T. Akomodačně vergenční vlastnosti vizuálního systému [online]. Brno, 2015 [cit.
2016-06-20]. Bakalářská práce. Masarykova univerzita, Lékařská fakulta. Vedoucí práce Mgr.
David Severa, dostupné z:
Nezbedová, I. Vliv věku a ametropií na akomodačně-konvergenční mechanizmus [online].
Brno, 2012 [cit. 2016-06-22]. Bakalářská práce. Masarykova univerzita, Lékařská fakulta.
Vedoucí práce Mgr. Petr Veselý, Dis., Ph.D., dostupné z:
Bruce, A. S., Atchison, D. A., Bhoola, H. Accommodation-Convergence Relationships and Age.
[online]. Investigative Ophtalmology &Visual Science, February 1995 [cit. 2016-06-22],
dostupné z: < http://iovs.arvojournals.org/article.aspx?articleid=2179954>
VII. CSKO 20. 10. 2016
35
Age-related changes of accommodative vergent attributes
Autor: Bc. Markéta Hrabovská
Supervisor: Mgr. David Severa
Accommodative vergent attributes of the visual system allows us to see sharply objects
at different distances. Accommodation ensures creation a sharp image of the object and
vergent movements equalize the position of both eyes. By working together, accommodative
and vergence system unites two images in one sensory perception – so is mediated binocular
vision.
Accommodation
Accommodation is a dynamic process, wherein the optical power of the eye is changed
so, that the observed object in the variable anteroposterior distance is sharply focused on the
retina. There are four components of accommodation - tonic, proximal, reflective and
convergent component. Tonic accommodative component is present even in the absence of
the stimulus, it is caused by resting tension of ciliary muscle. The proximal component is
induced by vision of a distant object. Reflective component is induced by blurred image and
ensures that retinal image is in focus. The last component is convergent component, which
can be triggered by the convergence on the basis of CA/C relationship. Convergent component
is controlled by fusion.
CA/C ratio describes the change of accommodative convergence per unit of the
convergence change. It indicates how many diopter we accommodate to 1 pD of convergence.
This ratio takes the value of 1:10. In current practice is not measured.
Accommodation and age
The ciliary body is not fully developed at birth, and the lens is softer than an adult lens.
Accommodative flexibility develops during the first months of life and is roughly comparable
with accommodation of adult about the fourth month. Development of the ciliary muscle and
thus the accommodation is completed in 3 years of life. The ability of the lens to arch and to
increase its optical power reduce throughout life. The result is distancing near point of
accommodation of the eye and decrease in accommodative amplitude. The first decline in
accommodative amplitude appear around 5 years of life, and continues to drop by about 0.3
D per year. Decrease accommodative amplitude versus age shows Duane curve. This leads to
the physiological accommodative disorder – presbyopia. The first symptoms of presbyopia
appear about the 40th year of life. There are many theories that explain the cause of
presbyopia - to illustrate mention just some of them.
VII. CSKO 20. 10. 2016
36
Picture 1: Duans curve
The Hess-Gullstrand theory attributes presbyopia to age-related changes in the lens,
with the amount of ciliary muscle contraction required for a particular change in
accommodation remaining the same as age increases, provided that this level is within the
amplitude limit. The Hess-Gullstrand theory is distinct from other theories in one important
respect. According to this theory, with increasing age there is an increasing excess of ciliary
muscle contraction beyond the ability of the lens and the capsule to respond to it.
The Fincham theory is similar to the Hess- Gullstrand theory in claiming that presbyopia
is due to the lens being less easily deformed with increasing age, but the maximum ciliary
muscle contraction is required for maximum accommodation at all ages.
The geometric theory posits that presbyopia is attributed to changes in the size and
shape of the lens that make the zonules apply tension more parallel to the surface of the lens.
Changes in zonule tension will thus have smaller effects on lens shape.
Extralenticular theories claim that presbyopia is caused by weakening of the ciliary
muscle or by loss of elasticity of zonules or ciliary body and choroid components.
Vergence
Ocular motility provide 4 rectus muscles - superior, inferior, lateral and medial and 2
oblique muscles - superior and inferior. Vergence is divided into volitional and reflective,
which is further divided into tonic, proximal, accommodative and fusion component. Tonic
vergence keeps a parallel position of the eyes without fusion stimulus. Proximal vergence is
induced by vision of nearer object. Fusion vergence is induced by retinal disparity and allows
exact adjustment visual axis. Accommodative vergence is induced by accommodation, which
is accommodative stimulus for convergence. The relationship between accommodation and
accommodative vergence expresses the ratio of AC/A.
AC/A ratio describes a change in the accommodative convergence when changing
accommodation. It indicates how much prism diopters of accommodative convergence will
change when the value of accommodation change is 1 D. As a normal values for a gradient
calculation methods is considered ratios 2:1-4:1. If AC/A ratio becomes higher values, it means
that the eyes on the amount of the accommodation converge more than they should.
Conversely, lower AC/A ratio indicates that in the respective accommodation occurs less
convergence.
VII. CSKO 20. 10. 2016
37
Accommodative convergent mechanism and age
Although the convergent properties stay with age almost unchanged, there is due to
reduction of accommodative power a change in the relationship between accommodation
and vergence. Therefore it is possible, that after the onset of presbyopia is the maximal
accommodation accompanied with more accommodative convergence than in the prepresbyopic
age. Thus, in order to maintain binocular vision, it will put increased demands on
the fusion convergence.
Issues of age-related changes of accommodative vergent attributes is object of several
theories and studies. However they did not come to a single opinion and their results differ.
Some theories (Helmholz,Hess,Gullstrand) indicates that at any age is required the same work
of ciliary muscle for creation the same change in accommodation and the relation between
accommodation and vergence is unchanged with age. Conversely, other theories (Donders,
Duane, Finchman and others) conclude that this relationship is changing throughout life.
Hess-Gullstrand theory states that for AC/A ratio may occur two situations. Either there
is a reduction in the AC/A ratio with age due to decrease accommodative convergence, which
is due to a reduction of accommodation; or AC/A ratio does not change with age because
accommodative convergence and accommodative reduced proportionally.
On the other side Duanne-Finchamova theory states that efforts to produce unit change
of accommodation increases with age. It means that either the ratio of AC/A increases with
age due to the increased accommodative convergence; or the AC/A is considerably increased,
because when increasing accommodative convergence the accommodation is reduced.
Most of the studies inclines to the fact that the AC/A ratio increases with age and the
CA/C ratio decreases, thus it invalidates Hess-Gullstrand theory. Some studies further confirm
the reciprocal relationship between the AC/A and CA/C ratio, which means that with
increasing age AC increases to such an extent that CA is reduced. On the other hand, other
studies have not confirmed this relationship, but they admit, that there is slight linear
connection between the AC/A and CA/C ratios. However, in the literature we meet with the
assertion that the ratios AC/A and CA/C ratios are completely independent.
Resources
Pluháček, F., Musilová, L. Akomodace a vergence [online], Optometrie UP [cit. 2016-06-20].
Diplomová, dostupné z:
Ouhelová, T. Akomodačně vergenční vlastnosti vizuálního systému [online]. Brno, 2015 [cit.
2016-06-20]. Bakalářská práce. Masarykova univerzita, Lékařská fakulta. Vedoucí práce Mgr.
David Severa, dostupné z:
Nezbedová, I. Vliv věku a ametropií na akomodačně-konvergenční mechanizmus [online].
Brno, 2012 [cit. 2016-06-22]. Bakalářská práce. Masarykova univerzita, Lékařská fakulta.
Vedoucí práce Mgr. Petr Veselý, Dis., Ph.D., dostupné z:
VII. CSKO 20. 10. 2016
38
Bruce, A. S., Atchison, D. A., Bhoola, H. Accommodation-Convergence Relationships and Age.
[online]. Investigative Ophtalmology &Visual Science, February 1995 [cit. 2016-06-22],
dostupné z: < http://iovs.arvojournals.org/article.aspx?articleid=2179954>
VII. CSKO 20. 10. 2016
39
Indikace k operaci šedého zákalu
Autor: Bc. Petra Janoušková
Školitel: Mgr. Matěj Skrbek
Katarakta bývá popisována jako jakékoliv zakalení normálně čiré oční čočky, které vzniká
v pokročilejším věku jejím přirozeným stárnutím a způsobuje tak poruchu její průhlednosti
nebo rozptylu procházejícího světla. Dle WHO hraje katarakta v celosvětovém měřítku velice
významnou roli, protože je jedním z nejčastějších očních onemocnění lidí nad 50 let věku.
Zároveň je toto onemocnění také jednou z hlavních příčin snížení zrakového komfortu a
následné slepoty vůbec. Podle statistik trpí kataraktou vždy jeden ze tří lidí postižených
slepotou a jeden z šesti s poruchou zraku (hlavně v rozvojových zemích). Z hlediska léčby nebyl
doposud objeven žádný účinný konzervativní způsob, jak zabránit vzniku a progresi tohoto
onemocnění na jinak zdravém oku. Proto je v dnešní době jediným možným řešením
chirurgické řešení. K operaci se přistupuje většinou až v případě, že katarakta snižuje kvalitu
života pacienta natolik, že je zhoršen jeho osobní či pracovní život nebo z jiného léčebného
důvodu (např. při specifických typech zeleného zákalu). V České republice je každoročně
indikováno k operaci šedého zákalu zhruba 7% všech pacientů s tímto onemocněním, což
znamená přes 70 000 chirurgických výkonů za rok.
Senilní katarakta se dělí do 3 základních kategorií na kortikální, nukleární a zadní
subkapsulární kataraktu, které si nyní blíže popíšeme.
Kortikální katarakta
Kortikální katarakta bývá lokalizována v kortexu (pouzdru) čočky, hlavně v její přední
nebo zadní ekvatoriální oblasti, kde tvoří široká a ostrá zakalení jehlanovitého tvaru s bází
zevně (ekvatoriálně) a vrcholy směřujícími do centra čočky. Nejčastěji lze tyto zákalky nalézt
na přední nasální straně čočkového pouzdra, což bývá spojeno s vyšší expozicí této části oka
UVB záření, které se zřejmě velkým dílem podílí na vzniku tohoto onemocnění.
Tento typ katarakty postupuje většinou relativně pomalu. Vyskytuje se oboustranně s
různými stádii progrese na každém z očí. Vidění bývá narušeno až v případě, že zákalky zasahují
do centrální pupilární oblasti a způsobují tak zamlžené vidění. První příznaky zhoršení zrakové
ostrosti a glare (oslnění) pociťují pacienti nejčastěji při jízdě autem za šera nebo za tmy, kdy
jsou osvěcováni reflektory protijedoucích automobilů.
Kortikální kataraktu můžeme dle stádia progrese dělit do několika dílčích stádií na
intumescentní kataraktu (v čočce se začíná hromadit voda a čočka začíná bobtnat), maturní
kataraktu (čočka je od kortexu až po jádro celá bílá nebo opalescentní), hypermaturní
kataraktu (kortex začíná kapalnět a unikat z kapsuly ven) a Morgagni kataraktu (jádro čočky
je zmenšeno a vlivem zkapalněného kortexu se volně pohybuje v čočkovém pouzdru, což je
nejtěžší typ katarakty).
VII. CSKO 20. 10. 2016
40
Nukleární katarakta
Nukleární katarakta je charakterizována homogenním nárůstem zakalení čočkového
jádra, které může být od žlutavého po červenohnědé až hnědavé zbarvení. Určitý stupeň
nukleární sklerózy a žlutavého zabarvení čočky je ještě u dospělých jedinců nad 50 let věku
považován za fyziologický a výraznějším způsobem se nepodílí na ovlivnění zrakových funkcí.
Tento typ katarakty se vyvíjí většinou pomalu a bývá obvykle taktéž lokalizován oboustranně.
Problémy s viděním nastávají až v případě,že jsou vlákna v jádru čočky vystavena stále většímu
tlaku, což způsobuje zvyšování jeho tvrdosti. Vzniká tak tzv. nukleární skleróza. S tím je
zároveň i spojeno zvýšení refrakčního indexu lomu a nastává myopický refrakční posun. To
v časném stádiu ocení hlavně někteří počínající presbyopové, kteří tak mohou při čtení do
blízka alespoň na určitou dobu začít odkládat brýle. Někdy se tomuto stavu říká také “druhý
zrak“.
Nukleární katarakta subjektivně způsobuje pacientovi větší problémy při pohledu do
dálky, než na blízko nebo při vyšších intenzitách světla. Mezi další následky nukleární katarakty
můžeme zařadit i méně častou monokulární diplopii, která vzniká jako důsledek výraznější
změny refrakčního indexu sklerotického jádra čočky, kdy se v jejím centru nachází více
lomivých ploch, oproti indexu kortexu čočky. Výsledkem je dvojitý obraz, který pacient může
v zorném poli spozorovat. Dále mohou vlivem progresivního zažloutnutí čočky nastat také
změny v barevného vidění, a to hlavně v oblasti zhoršení rozlišování modrého světla.
Zadní subkapsulární katarakta
Zadní subkapsulární katarakta se vyskytuje na zadním pólu čočky, před jeho zadním
pouzdrem a projevuje se ze všech tří typů katarakty nejdříve, zhruba kolem 55 let věku.
Většinou bývá spojena s celkovým systémovým či očním onemocněním, mezi které patří např.
diabetes mellitus, retinitis pigmentosa, úrazy oka, uveitidy, nebo katarakta jako důsledek
pravidelného požívání léčiv (dlouhodobě kortikosteroidů). Tento typ katarakty může
významným způsobem snižovat vidění v centrální oblasti, které bývá nejvíce citelné při zúžení
zornice, protože zakalení leží přimo v jejich středu.
Pacienti, kteří mají PSC, vykazují docela dobrou zrakovou ostrost do dálky v nižších
světelných podmínkách, ale výrazně snížené vidění do blízka s glare (oslněním ostrým zdrojem
světla při současném pozorování nízkokontrastního objektu) při jasném denním světle, při
čtení nebo při nočním řízení automobilu (glare bývá jedním z prvních a častých příznaků
katarakty).
Rizikové faktory pro vznik senilní katarakty
Senilní katarakta je multifaktoriální onemocnění, na jehož vzniku se podílí mnoho
faktorů, které se navzájem prolínají a doplňují, a každý z nich se podílí na vzniku katarakty
různě velkým dílem. Mezi tyto faktory patří např: genetika (vědecky je prokázána existence
genů, které jsou zodpovědné za vznik katarakty, jejich přímý vliv na vzniku a progresi tohoto
onemocnění se však zdá být docela malý - jednotky procent), věk a pohlaví (mnohem častěji
bývají postiženy ženy než muži, s vyšším věkem výrazně stoupá riziko vzniku katarakty), UV
záření a následný oxidační stres čočky, (čočkový epitel je citlivý na poškození volnými radikály,
které se vlivem působení UV záření v čočce tvoří. Tyto radikály způsobují nevratné
VII. CSKO 20. 10. 2016
41
morfologické změny, jejichž výsledkem je degradace a modifikaci čočkových proteinů. Místo
pobytu (více jsou ohroženi lidé, kteří žijí ve vysokohorských oblastech, kde je vyšší expozice
UVB záření), zdravý životní styl: tělesná váha (vyšší hmotnost nebo naopak podvýživa může
ve spojitosti s cukrovkou nebo kouřením zvyšovat riziko vzniku katarakty), dostatečný přísun
vitamínů, např. riboflavin, kyselina askorbová (vitamín C) či vitamín E významným způsobem
snižují riziko vzniku katarakty. Cholesterol a sůl toto riziko zase zvyšují, stejně jako kouření a
alkohol, léky (např. kortikosteroidy) a systémová onemocnění (diabetes mellitus,hypertenze).
Indikace k operaci katarakty
Zda pacient operaci katarakty podstoupí či nikoliv se rozhoduje lékař s pacientem
společně na základě tří hlavních faktorů, mezi které patří: kvalita zraku, jak ji vnímá pacient,
léky, které pacient užívá a v neposlední řadě i kosmetické účely.
Kvalita zraku hraje před operací katarakty velmi důležitou roli, protože to, do jaké míry
jsou sníženy zrakové funkce, významným způsobem ovlivňuje činnosti, které pacient běžně
vykonává. Operace katarakty tak bývá indikována většinou až v případech, kdy je již výrazným
způsobem pacientovi zabráněno ve vykonávání každodenních aktivit. Pokud však pacient
potřebuje zrak k výkonu specifické profese nebo řízení automobilu, provádí se operace
katarakty i dříve.
Z kosmetických účelů je katarakta indikována v případě maturní katarakty, aby byl
zachován přirozený vzhled oka (tmavá zornice).
Metodika výzkumu
Cílem výzkumu je zjištění možné ochrany oční čočky při dlouhodobém nošení brýlové
korekce (nejméně 20 let), nebo alespoň prokázání pozitivního vlivu používání brýlové korekce
jako protektivního faktoru k oddálení vzniku či zpomalení progrese onemocnění u stálých
nositelů brýlové korekce.
Hypotézy
Hypotéza – zkoumá vztah mezi vykonáváním předem definovaných aktivit a jejich
ovlivněním kataraktou na postiženém oku.
H0: Pacienti s kataraktou budou v testu vykazovat mnohem nižší skóre, než srovnávací
skupina pacientů bez katarakty.
H1: Rozdíly ve skóre mezi pacienty s kataraktou a bez katarakty nebudou diametrálně
odlišné.
Metodika – sběr dat:
Výzkum se uskutečňuje ve FNUSA formou dotazníkové studie, kde pacienti vyplňují
dotazník, který se skládá ze dvou částí: 1. část obsahuje základní údaje o pacientech, mezi
které patří pohlaví, věk (vztažený ke dni operace katarakty), velikost refrakční vady ve formě
sférického ekvivalentu rozdělená na: emetropii od 0 D do + 0,75 D, nízkou hyperopii od + 1,0
D do + 3,0 D, nízkou myopii od -0,25 D do -3,0 D, hyperopii od + 3,25 D, myopii od -3,25 D, a
brýlovou korekci.
VII. CSKO 20. 10. 2016
42
2. část je složena z dotazníku o 13 specifických otázkách, který je kombinací VF-14 testu
a NIKE testu,které pomáhajík lepší diagnostice stádia katarakty. Tyto dotazníky jsou zaměřeny
na denní aktivity, jako je čtení novin nebo cenovek při nakupování, sledování Tv, rozpoznávání
tváří, chůze do schodů, vaření či různé domácí práce. Každá otázka obsahuje číselnou škálu od
0 do 4, podle níž je poté test vyhodnocen (viz. Tab. č.1).
Nejnižší skóre je 0 bodů (maximální potíže při vykonávání dané aktivity), nejvyšší skóre
100 bodů (žádné potíže při vykonávání aktivity).
Tabulka 1: Složení otázek v dotazníku
Tabulka 2: Hodnotící škála pro vykonávání denních aktivit pacientů
Výsledky výzkumu
Výstupem ze studie budou výsledky průměrného věku operace katarakty na daném
pracovišti za určité období, jejich výsledné srovnání v rámci pohlaví mezi ženami a muži,
rozdělení dle věkových kategorií, a velikosti refrakčních vad u pacientů, kteří budou
podstupovat operaci katarakty.
Druhá část výsledků bude vyhodnocení dotazníku a následné zjištění skóre u pacientů s
kataraktou ve srovnání s referenční skupinou zhruba stejně starých pacientů bez katrakty.
Zdroje
Elliott, D. Clinical procedures in primary eye care. 4. vyd. Edinburgh: Elsevier, 2014, 318 s. ISBN
978-0-7020-5144-4.
Vlk, F., Vlková, E. Lexikon očního lékařství – výkladový ilustrovaný slovník. vid. 1 Brno: František
Vlk, 2008, 607 s. ISBN 978-80-239-8906-9.
Kuchynka, P. Oční lékařství. vid. 1. Praha: Grada Publishing a.s., 2007, 812 s. ISBN 978-80-247-
1163-8.
Silverstone, B. The Lighthouse handbook on vision impairment and vision rehabilitation.
Oxford: Oxford University Press, 2000. ISBN 978-0-19-509516-6.
Remington, L. A. Clinical anatomy and physiology of the visual system. 3. vid. St. Louis:
Butterworth-Heinemann, 2012. ISBN 978-1-4377-1926-0.
Kraus, H. Kompendium očního lékařství. 1 vid. Praha: Grada, 1997, 360 s. ISBN 80-7169-079-1.
Kraus, H., Karel, I., Růžičková, E. Oční zákaly. Praha: Grada, 2001. ISBN 80-7169-967-5.
Schnider, C. Vyvrácení mýtů o UV záření. Česká oční optika. Brno: Společenstvo českých optiků
a optometristů, 2015, roč. 56, č. 2, ISSN 1211-233X.
Kanski, J. J. Clinical ophthalmology: a systematic approach. 6. vyd. Edinburgh: ButterworthHeinemann,
2007, 931 s. ISBN 978-0-08-044969-2.
VII. CSKO 20. 10. 2016
43
Indication for cararact surgery
Author: Bc. Petra Janoušková
Supervisor: Mgr. Matěj Skrbek
Cataract is described as opacity in normally clear lens of the eye, which occurs by people
in oldery age its natural aging and causes problems of its transparency or scattering of light.
WHO said, that cataract is globally a very important problem, because it is one of the most
common eye disease of people over 50 years. This disease is one of the main cause which
reduced visual comfort and produced subsequent blindness. According to the statistics, one
in every three people affected by blindness and one of six visually impaired suffer for the
cataracts (especially in developing countries). The conservative ways to treatment and
prevent to development progression of this disease in an otherwise healthy eye has not yet
discovered. Therefore, the only possible solution is a surgical solution. The cataract is treated
usually only if is reduces the quality of life or if it is indicated for the other medical reasons
(e.g. in specific types of glaucoma). In the Czech Republic is annually indicated for cataract
surgery about 7% of all patients with this disesase, which means over 70,000 surgical
procedures per year.
Senile cataract is divided into the three basic categories: cortical, nuclear and posterior
subcapsular cataracts, which are being described now.
Cortical cataract
Cortical cataract is localized in the cortex of the lens, mainly on the front or rear
equatorial areas where they make a broad and sharp pyramidal shapes with a base out
(equatorial) and the tops directed to the center of the lens. We can found most of these
opacities on the front and nasal side in the lens cortex, it is often associated with higher
exposure to the UVB radiation of the eye, which has probably a great deal involved in the
formation of the eye disease. This type of cataract has usually relatively slowly progression. It
occurs both eyes with different stages of progression in every eye. Vision is impaired only if
the opacities extend into the central pupillary area and caused blurred vision. The first signs
of deterioration is visual acuity and glare, which most patients experienced while driving in
the dark or when they are enlightened by the headlights of oncoming cars.
Cortical cataract can be divided into several stages: to intumescent cataract ( the lens
accumulated the water and begins to swell), mature cataract (lens is from the cortex to the
nucleus white or opalescent), hypermature cataract (cortex begins more watery and escape
out from the capsule) Morgagni cataract (the nucleus of the lens is reduced and the influence
of liquefied cortex moves freely in the lens cortex, it is the most difficult type of cataract).
Nuclear cataract
Nuclear cataract is characterized by an uniform increase in the opacities of the lens
nucleus, which can be from yellowish and reddish-brown to brown color. A small degree of
nuclear sclerosis and the yellowish tint is by adults over 50 years of age physiological and does
VII. CSKO 20. 10. 2016
44
not participate in influencing the visual function. This type of cataract usually slowly develops
and usually is located on the both eyes too. Vision problems occur only if is in the lens nucleus
higher pressure of nuclear fibers, which caused increase on its hardness. The result is called
nuclear sclerosis. With this condition is also associated increase in refractive index, and the
refractive myopic shift. This is attractive in early stages by presbyopic patients, who can read
at near vision, for some time without the glasses to near. Sometimes this condition also called
"second sight".
The nuclear cataract subjectively causes major problems when patients looking into the
distance, or when they looking to the light with higher intensities. Other consequences of
nuclear cataract which are less frequent is monocular diplopia, which arises as a result of
significant changes in the refractive index of the sclerotic nucleus compared to the index of
the lens cortex. The result is a double image, which the patient may observe in the visual field.
Due to the progressive yellowing of the lenses also changes the color vision, especially in the
area of blue light.
Posterior subcapsular cataracts
Posterior subcapsular cataracts is located at the back of the lens, just in front of the
posterior capsule, and reflected from all three types of cataract as the first, at around 55 years
of age. It is usually associated with eye diseases such as diabetes mellitus, retinitis pigmentosa,
eye injuries, uveitis, cataracts or as a consequence of regular ingestion of drugs
(corticosteroids for a long term). This type of cataract can cause a dramatic reduction in vision
with pupil constriction, because they are generally centrally positioned within the pupil.
Patients who have PSC have a good visual acuity in low light conditions, but they have a
significantly reduced near vision with glare (glare is a sharp light source when you watching
on a slow-contrast object) in sunny daylight, when reading books or in night driving a car. Glare
is one of the earliest and most frequent symptoms of this disease.
Risk factors of senile cataracts
Senile cataract is an multifactorial disease, which involved many factors. This factors
blends together and each of them has differently contribution to the formation of the
cataracts. These factors included: genetics (scientifically is the existence of genes which are
responsible for cataract formation demonstrated, but their impact on the development or
progression of this disease in comparison with the other effects is probably small - units of per
cents), age and gender (more affected with cataract are women than men, with higher age
very increased risk rise of cataract), UV radiation and oxidative stress (lens epithelium is
sensitive to damage by free radicals. These radicals can caused the morphological changes,
which can modificated lens proteins and so caused irreversible changes in the lens. Place of
residence (more in risk are people who live eg. in higher located areas where is higher
exposure UVB radiation). Healthy lifestyle: body weight (higher weight or malnutrition with
diabetes and smoking can increased the risk of cataract formation), an adequate supply of
vitamins, such as riboflavin, ascorbic acid (vitamin C) and vitamin E significantly reduced the
risk of cataract formation. Cholesterol and salt this risk increased such as smoking and alcohol,
medicaments (mainly corticosteroids) and general disease (diabetes mellitus, hypertension).
VII. CSKO 20. 10. 2016
45
Indications to cataract surgery
If patient go to the cataract surgery depends on doctor and patient which are decided
together according to 3 main factors, such as visual impairment, medicaments which patient
take on its disease and cosmetics purpose.
Visual function play before cataract surgery very important role, because how are visual
function decreased, affected daily activities, which patient usually executed. Cataract surgery
is usually indicated in time when patient cannot this activity executed. If patient needs its
vision to special work or driving a car, it may be indicated earlier. From cosmetics purpose is
cataract surgery indicated if patient have mature type of cataract and need a normal
appearance of its eye (dark pupil).
Research methodology
The aim of the research is to determine the possible protection of the eye lens for a
long-term weared spectacles correction (at least 20 years), or demonstrate the positive impact
of the use spectacles correction as a protective factor to delay or slow down the progression
of the disease by the patients with the permanent spectacle correction.
Hypothesis
Hypothesis I - examined the relationship between execution of defined activities and
cataract influence on this activities.
H0: Patients with cataract will have in test lower score than comparative group of
patients without cataract.
H1: There are no significant differences between patients with cataract and
comparative group of patients without cataract.
Methodology - data collection
Research conducted at the University Hospital FNUSA in the form of questionnaire
study, where patients complete questionnaire, which is divided on 2 parts. 1. part
collected general information about patients, such as sex, age (in the time of cataract
surgery), size of refractive errors in the form of spherical equivalent such as: emetropia
from 0 D to + 0,75 D, lower hyperopia from + 1,0 D to + 3,0 D, lower myopia from -
0,25 D to -3,0 D, hyperopia from + 3,25 D, myopia from -3,25 D, glasses correction.
VII. CSKO 20. 10. 2016
46
2. part is composed from questionnaire, where is 13 specific questions, which are
combinations of VF-14 test and NIKE test, which are used to better indication to cataract
surgery. This questionnaires are intent on daily activities, such as reading newspaper,
watching on Tv, reading price in shops, faces recognizing, seeing step stairs, cooking or
housework making.
Every question have scale from 0 to 4. With this scale is questionnaire evaluated.
Lower score is 0 (patient cannot performed this activity), higher score is 100 (patient
have no problems with this activity).
Research results
The outcome of the study results will bee average age of cataract surgery at the work
place for a certain period and the resulting comparison in the context of sex between men
and women and the size of their refractive errors, in group of patients who go to the cataract
surgery.
The second part will be questionnaire evaluation and find cataract score by patient with
cataract and patients without cataract.
Resources
Elliott, D. Clinical procedures in primary eye care. 4. vyd. Edinburgh: Elsevier, 2014, 318 s. ISBN
978-0-7020-5144-4.
Vlk, F., Vlková, E. Lexikon očního lékařství – výkladový ilustrovaný slovník. vid. 1 Brno: František
Vlk, 2008, 607 s. ISBN 978-80-239-8906-9.
Kuchynka, P. Oční lékařství. vid. 1. Praha: Grada Publishing a.s., 2007, 812 s. ISBN 978-80-247-
1163-8.
Silverstone, B. The Lighthouse handbook on vision impairment and vision rehabilitation.
Oxford: Oxford University Press, 2000. ISBN 978-0-19-509516-6.
Remington, L. A. Clinical anatomy and physiology of the visual system. 3. vid. St. Louis:
Butterworth-Heinemann, 2012. ISBN 978-1-4377-1926-0.
Kraus, H. Kompendium očního lékařství. 1 vid. Praha: Grada, 1997, 360 s. ISBN 80-7169-079-1.
Kraus, H., Karel, I., Růžičková, E. Oční zákaly. Praha: Grada, 2001. ISBN 80-7169-967-5.
Schnider, C. Vyvrácení mýtů o UV záření. Česká oční optika. Brno: Společenstvo českých optiků
a optometristů, 2015, roč. 56, č. 2, ISSN 1211-233X.
Kanski, J. J. Clinical ophthalmology: a systematic approach. 6. vyd. Edinburgh: ButterworthHeinemann,
2007, 931 s. ISBN 978-0-08-044969-2.
VII. CSKO 20. 10. 2016
47
Oční protézy
Autor: Bc. Lucie Klusoňová
Školitel: Mgr. Sylvie Petrová
Skleněné oční protézy
Vývoj
Sklo jako materiál pro výrobu začal jako první propagovat Paré ve Francii v 16. století.
Později se centrum výroby přesunulo do Benátek a přes Francii se dostalo do Německa. To se
stalo ve výrobě skleněných očních protéz velice úspěšným a odtud také pochází technologie
výroby. O největší úspěchy se zasloužil Ludwig Müller-Uri, pocházející z Německa. U nás se
výroba skleněných očních protéz rozvinula po první světové válce v Jablonci nad Nisou. Se
začátkem druhé světové války přestalo být výhradním materiálem pro výrobu sklo. Nicméně
je v Evropě pro své kladné vlastnosti stále používáno.
Obrázek 1: Částečně dokončená protéza, černé tyčinky na pupilu.
Materiál pro výrobu
Do České republiky je sklo pro výrobu očních protéz dováženo z Německa. Materiál lze
rozdělit do tří skupin podle toho, kterou část protézy tvoří. Bulbus je vyroben ze speciálního
opálového skla, které neobsahuje těžké kovy a kadmium. Materiál na duhovku tvoří široká
škála barevných skel. Ty se mezi sebou mísí a tím se dosáhne optimální barvy duhovky.
Rohovka je tvořena krystalickým sklem, které překrývá barevnou duhovku. Vrstvením se docílí
hlubokého a přirozeného pohledu.
Obrázek 2: Nástroje pro měření vzdáleností, barevné tyčinky.
VII. CSKO 20. 10. 2016
48
Postup výroby
Výroba skleněné oční protézy je velmi náročná. Klient je přítomen celému procesu
výroby. Ten trvá přibližně hodinu. Nejprve je nutné změřit pacientovu orbitu a zvolit vhodný
tvar budoucí protézy. Kontroluje se hloubka očnice, tvar víček, funkce víčkových svalů a stav
po provedené operaci. Optimální tvar se posléze vybere vkládáním zkušebních modelů protéz
do prázdné očnice.
Nad kahanem se nahřeje asi 2 cm dlouhé skleněné trubice, ze které se odtáhne odtažek.
Z odtažku se potom vyfoukne kulička o velikosti oka, která je ve středu trubičky, jejíž jeden
konec je odstraněn.
Obrázek 3 a 4: Sklo se vyfoukne do kuličky velikosti oka. Přední nosná část je
násedně odstraněna
Na vrchlík kuličky se nataví základní barva, která se profoukne do tvaru půlkuličky.
Obrázek 5 a 6: Nastavení a tvarování základní barvy
Na vzniklou polokouli se maluje budoucí duhovka vhodně zvolenými barevnými
tyčinkami.
Obrázek 7: Použití barevných tyčinek
Po dobarvení se půlkulička rozehřeje a profukováním je docíleno vyrovnání budoucí
duhovky s koulí. Do středu se nanese černou skleněnou tyčinkou zornice o průměru asi 3 mm.
Hladítkem se černé sklo rozmačká do požadované velikosti. Vše se znovu rozehřeje,
rovnoměrně otáčí a profukuje. Dojde tak ke stavení všech skel.
VII. CSKO 20. 10. 2016
49
Dále se pokračuje vytvořením krystalového povrchu. Rozehřeje se krystalová tyčinka
a vrchlík koule s duhovkou. Krystal se přitaví na duhovku a tím se získá dojem hloubky a lesk
stejný jako u přirozeného oka.
Obrázek 8 a 9: Tvorba rohovky a simulace krevních cév
Výsledný dojem je dotvořen kresbou cévek na bělimu. Cévky se naznačují nitkami
o tloušťce vlasu vytaženými z červené tyčinky. Pro vyhlazení budoucí protézy následuje opět
zatavení v plameni. Ke konci se foukáním dotvarovává koule dle předlohy. Plamenem se
objíždí budoucí okraje a tvar je i nadále neustále kontrolován a měřen měrkou, aby bylo
dosaženo požadovaných rozměrů potřebných pro pacienta. Zadní část koule se nahřeje
a profukuje, čímž je připravena na odstranění a protéza získá požadovaný skořápkovitý tvar.
Obrázek 10 a 11: Finální úprava protézy a odstranění zadní nosné tyčinky
Protéza se posléze chladí v předehřátém grafitovém kelímku s pískem. Tato fáze trvá
přibližně 40 minut a může při ní dojít k popraskání, jelikož výrobek nemá na průřezu stejnou
tloušťku. Po vychladnutí se omyje ve vlažné vodě a lze provést zkoušku na pacientovi.
V případě, že je protéza chybně vytvořena, musí začít výroba nové protézy od začátku.
Chybně vyrobenou oční protézu nelze předělat.
Péče a životnost
O protézu je nutné správně pečovat, předejde se tak případným zdravotním
komplikacím i rychlejšímu opotřebení protézy. Jelikož slzy rozrušují povrch protézy, je nutné
protézu ráno a večer vyndat a opláchnout pod tekoucí vodou. Doporučuje se i vyplachování
orbity, zvláště v případě zánětlivého onemocnění, nachlazení nebo chřipky. Při pocitu suchého
oka se doporučuje použít zvlhčující kapky. Při správném používání je možné kontinuální
nošení. V případě, že pacient nechce mít protézu nasazenou přes noc, je vhodné ji vyčistit,
vysušit a uložit ji do uzavřené nádoby. Pokud dojde v důsledku nepravidelností a drsnosti
povrchu protézy ke dráždění očnice a tím ke zvýšené produkci slz, je vhodné oční protézu
vyměnit.
Pacient má od pojišťovny nárok na 2 kusy skleněných protéz ročně, ty jsou plně hrazeny
zdravotní pojišťovnou. Protéza se vyrábí na lékařský předpis a není nutné schválení revizním
VII. CSKO 20. 10. 2016
50
lékařem. V případě rozbití si pacient novou protézu hradí sám. U očních protéz ze speciálního
skla představuje doporučovaná životnost asi jeden až jeden a půl roku.
Výhody a nevýhody
Skleněné oční protézy jsou řešení pro pacienty, kteří nemohou kvůli alergii nosit
akrylátové oční protézy. K jejich kvalitám patří i stálost barev a lesk věrohodně napodobující
zdravé oko. Duhovka působí plasticky a hloubkově. Technika zpracování navíc vytváří hladký
povrch bez výčnělků, který zajišťuje konfort při nošení. Výborná je i smáčivost skla, díky ní slzy
vytváří na povrchu tenký kluzký film, který chrání citlivou spojivku před výraznějším třením.
Navíc je pacientovi protéza vyrobena během jedné schůzky, a to přímo na počkání.
V porovnání s akrylátovými protézami se při výrobě se sklem pracuje obtížněji.
V důsledku kontaktu protézy s očními tekutinami, které mají nižší pH, je povrch rozrušován,
což způsobuje nepříjemné pocity při nošení. Sklo je náchylné k poškrábání, například prachem
nebo nečistotami, která vniknou pod víčko a poškodí povrch protézy rýhami.
Hlavní nevýhodou skleněné oční protézy je její křehkost. K rozbití dochází zejména při
vyndávání protézy při jejím ošetřování, může se však roztříštit i při sportu či nehodě. Je také
nutno dát pozor na vystavování protézy velkým teplotním změnám, neboť může dojít k jejímu
popraskání. V zimě protéza studí a je zde i možnost přimrzání slz na povrch protézy. Co se
vzhledu týče, jediný problém tvoří zornice, která se zvlášť při pohledu zblízka jeví jako kulička,
působí rušivě a nepřirozeně.
Akrylátové oční protézy
Vývoj
Testování akrylové pryskyřice začalo v USA roku 1943. Bylo nutné najít jiný materiál než
sklo, jehož dovoz byl pozastaven. Navíc některé jeho vlastnosti nebyly plně vyhovující. Začaly
se proto vyrábět skladové akrylátové oční protézy v několika tvarech a barvách duhovky. Ty
však nemohly zajistit pacientovi dostatečný konfort, proto se přešlo na individuální výrobu.
V současné době se jako materiál pro výrobu používá akrylát, superpont a metylmetakrylát.
Tento základní materiál tvoří z 95 % směsi, zbývajících 5 % jsou veřejnosti neznámé stále se
měnící přísady.
Výroba
K sejmutí otisku pacientovi očnice se používají otiskovací lžíce. Tyto lžíce jsou vyrobeny
z akrylátové pryskyřice, mají dutou rukojeť, kterou se zavádí plastová jednorázová otiskovací
stříkačka. Pokud je otisk přesný, odstraní se přebytečný materiál a periferie otisku pak slouží
jako základ pro výrobu oční protézy.
Obrázky 12, 13 a 14: otiskovací lžíce, otisk a voskový model
VII. CSKO 20. 10. 2016
51
Otisk pak slouží k výrobě formy. Po ztvrdnutí formy se její povrch natírá separačním
materiálem a následně se do takto připravené formy může nalít roztavený vosk.
Voskový model se následně zkontroluje a případně upraví, aby přesně simuloval
ztracené oko. Kontroluje se, zda má správnou velikost, podporuje tkáně, simuluje oční pohyby
a má správné pokrytí očními víčky.
K simulaci duhovky při výrobě akrylátové protézy existuje více způsobů výroby
i centrování. Nejjednodušší možností je výběr předvyrobeného disku, který odpovídá barvě
zdravého kontralaterálního oka. K pracnějším způsobům patří malování duhovky na disk
pomocí olejových barev vmíchaných do polymethylmethakrylátového barevného media.
Korneální knoflík se vyrábí za použití teplem polymerizující akrylátové pryskyřice.
Velikost knoflíku je obdobná jako velikost duhovkového disku. Připojuje se k malovanému
duhovkovému disku pomocí kyanoakrylátového lepidla.
Obrázek 15, 16 a 17: Rohovkový knoflík a duhovkový disk, vytváření formy
z dentálního kamene a akrylová protéza s přetokem.
Máme-li voskový vzor, pokračuje se výrobou formy z dentálního kamene nebo sádry. Do
této formy se umístí duhovková destička a zalije se bílým polymethylmethakrylátem. Ten se
pak vytvrzuje v peci po dobu 2,5 hodiny. Udržuje se teplota 110 °C a tlak 4 bary. Po vytvrzení
se odstraní přebytečný materiál, protéza se brousí a leští. Je možné vložením do pacientovy
očnice znovu zkontrolovat velikost a umístění duhovky v bílém základu. Pokud je výsledek
uspokojivý, nastupuje proces tónování.
Pro simulaci krevních cév se používá bavlněných nitíčervené barvy. K vytváření přesného
odstínu bělma odpovídajícího druhému oku se používají suché stabilní přírodní jemně
broušené barevné pigmenty. Jakmile je dosaženo přesného přizpůsobení barev, báze protézy
se umístí do pece, kde se udržuje teplota 85 °C po dobu 30 minut. To dovoluje barvě saturovat
a zabraňuje budoucímu blednutí. Jakmile je tento proces dokončen, nanese se poslední vrstva
čirého plastu, protéza se umístí zpět do formy a vrstva na předním povrchu polymerizuje, čímž
se dokončuje výrobní proces. Poté probíhá ořez a leštění. Konečná protéza ještě může
vyžadovat drobné úpravy, jako je přidání nebo odstranění polymethylmethakrylátu v různých
místech.
VII. CSKO 20. 10. 2016
52
Obrázek 18 a 19: Leštění a konečný vzhled protézy
Životnost
Není přesně definované, jak dlouho protéza vydrží. Moderní plastové protézy jsou
trvanlivé a nepraskají. Dochází však k postupnému zhoršování kvality plastu a pigmentů.
Protéza by měla být měněna každé tři roky. Při případném poškrábání oční protézy je možné
její přeleštění. Velikost se může zmenšit nebo zvětšit v závislosti na změnách očnice. Každý
pacient má nárok na 1 protézu v průběhu 3 let.
Výhody a nevýhody
Protézy ze syntetické pryskyřice se kvůli nižší tvrdosti povrchu vyznačují větší mírou
opotřebení, povrch se stává hrubším a nerovnoměrným po krátké době používání. Není zde
taková smáčivost jako u skleněné protézy. Akrylátové protézy jsou však odolnější vůči
naleptávajícímu účinku slz. Nevýhodou je i menší plasticita duhovky, naopak pupila vypadá
přirozeněji. Doba výroby je delší než u skleněných protéz. U některých pacientů se také
objevují alergie na tento materiál. Velkou výhodou je však menší rozbitnost.
Zdroje
Artopoulou, I.-I. et al. Digital imaging in the fabrication of ocular prostheses. The Journal of
Prosthetic Dentistry. 2006-04, vol. 95, no. 4, p. 327–330. DOI:
10.1016/j.prosdent.2006.01.018.
Darsová, D. Oční protézy u dětí a žáků se zdravotním postižením. Oční klinika dětí a dospělých
UK 2. LF a FN Motol. 2011
Doshi, P., Aruna,B. Prosthetic management of patient with ocular defect. The Journal of Indian
Prosthodontic Society. 2005, vol. 5, no. 1, p. 37–38.
Gliklich, R. E. et al. Combining Free Flap Reconstruction and Craniofacial Prosthetic Technique
for Orbit, Scalp, and Temporal Defects. The Laryngoscope. 1998, vol. 108, no. 4, p. 482–487.
DOI: 10.1097/00005537-199804000-00004.
Goyal, M., Goyal, S., Dhanasekar, B. Modern trends in modeling of extra-oral defects. Indian
Journal of Dental Research. 2014, vol. 25, no. 1, p. 128. DOI: 10.4103/0970-9290.131170.
Guttal, S. S. et al. A Simple Method of Positioning the Iris Disk on a Custom-Made Ocular
Prosthesis. A Clinical Report. Journal of Prosthodontics. 2008-04-01, vol. 17, no. 3, p. 223–227.
DOI: 10.1111/j.1532-849X.2007.00272.x.
VII. CSKO 20. 10. 2016
53
Kathuria, N. et al. A modified technique and simplified laboratory procedure for Ocular
Prosthesis Fabrication. Journal of Prosthodontic Research. 2012-04, vol. 56, no. 2, p. 147–150.
DOI: 10.1016/j.jpor.2011.07.002.
Mccord, C. ARTIFICIAL EYES; THE EARLY HISTORY OF OCULAR PROSTHESES. Journal of
Occupational Medicine. 1965-02, p. 61–8.
Patil, S. B. et al. Ocular prosthesis: a brief review and fabrication of an ocular prosthesis for
a geriatric patient. Gerodontology. 2008-03-01, vol. 25, no. 1, p. 57–62. DOI: 10.1111/j.1741-
2358.2007.00171.x.
Raizada, K., Rani, D. Ocular prosthesis. Contact Lens and Anterior Eye. 2007-07, vol. 30, no. 3,
p. 152–162. DOI: 10.1016/j.clae.2007.01.002.
Waldhegerová, L. Oční protézy. Česká oční optika. 2006, vol. 47, no. 2, p. 44–46. ISSN 1211-
233X.
Muellersoehne. Manufacturing of Ocular Prostheses. F. Ad. Müller Söhne OHG © 2016 [cit.
2016-05-31] Dostupné z: http://www.muellersoehne.com/en/m_tillverkning.htm
VALTERA PROTEŽU LABORATORIJA. Ocular protetics [online]. Scientific Institution „Valters´
Protethic Laboratory“ © 2016 [cit. 2016-05-31]. Dostupné z:
http://www.vpl.lv/eng/ocular_prosthetics/choice_of_prosthesis
ASPIRION. Oční protéza – údržba a často kladené otázky, Nikolaus Kerbl © 2016 [cit. 2016-06-
23]. Dostupné z: http://www.asprion.at/ocni_protezy/casto_kladene_dotazy.html
VII. CSKO 20. 10. 2016
54
Ocular prostheses
Author: Bc. Lucie Klusoňová
Supervisor: Mgr. Sylvie Petrová
Glass ocular prostheses
Development
Pare started propage glass as a material for the prostheses production in France in the
16th century. Later, the manufacturing center moved to Venice and across France finished in
Germany. Germany was very succesful in the production of glass ocular prostheses and the
production technology is from there. The greatest success is credited to Ludwig Müller-Uri,
from Germany. Czech republic manufacture glass eye prosthesis evolved after World War in
Jablonec nad Nisou. With the beginning of World War II ceased to be the exclusive material
for glass. However, it is in Europe for its positive qualities still used.
Picture 1: Parcially finished prostheses with black glass sticks for iris
Production material
Production glass material is imported to Czech republic from Germany. The material can
be devied to three groups by the purpose they are used for. Bulbus is manufactured from
special opal glass which contains no hard metals and cadmium. Iris material is made of colour
range glass. They mix with each other therefore make optimal iris color. Cornea is made from
cristalic glass, which overlaps colored iris. By layering it is made natural and deep look.
Picture 2: Measuring tools, colorfull glass sticks
VII. CSKO 20. 10. 2016
55
Manufacture process
Manufacture glass ocular prosthesis is very difficul. Client sees the hole process by
himself/herself. The process lasts aproximately one hour. At first is mandatory to measure
patient´s orbit and chose proper prosthesis shape. Orbit deep, eyelids shape, eyelids muscles
and after surgery state is checked. Optimal shape is chosen from probationary models.
Two centimetres long glass tube is heated over a burner. Part of the glass tube is blown
to a size of an eye, which is in the center of the tube. It's end is removed.
Picture 3 and 4: The glass tube is blown to the size and shape of the eye.
Additional tube in the front is removed.
First layer of colour is smelt on the top of the ball, which is blown to the shape of a half
of a ball.
Picture 5 and 6: Applying of the base color
On the final half-ball is painted future iris with properly chosen coloured sticks.
Picture 7: The use of coloured sticks
After the paining is done, the half-ball is blown through until it shapes into the final iris
with ball. Black glass stick paints pupil to the center with diameter 3 mm. Black glass is mashed
by float until it gets the right size. Everything is heaten up again, rolled and blown through.
Therefore all glass layers are merged together.
Then we have to make crystalic surface. Crystalic stick and top of the ball with iris is
heaten up. Crystal is melt to the iris, so it makes an illusion of the real eye.
VII. CSKO 20. 10. 2016
56
Arterioles are painted on the sclera for more realistic look. Arterioles are made with
thread which are thick as hair.
Picture 8 and 9: Creation of cornea and arterioles
To rub the prosthesis it has to be heaten up once more. At last, the ball is shaped with
blowing by the pattern. Edges are shaped with flame and the size must be checked all the time
to fit right into patient's eye. Back side of the ball is heated and blown, therefore it is ready
for removing and the prosthesis get the right shell shape.
Picture 10 and 11: Final editing and removal of additional holding tube.
Prosthesis is cooled in warm grafit bowl with sand. This phase lasts about 40 minutes
and prosthesis may crack, because it doesn't have the same diameter thickness. After cooling
process, prosthesis is washed in a warm water, after that it can be tried on the patient.
In case of manufacture failure, whole process must be done all over again, because
defected prosthesis cannot be fixed.
Care and service life
It´s necessary to care about prosthesis to prevent health complications and material
wear. Because tears damage a prosthesis, it must be put out every morning and the evening
to clean it under the water. It is advised to clean orbits as well, especially during inflammation,
cold or influenza. For dry eye, wet drops should be used. In case of right usage it is possible to
wear continually. If patient doesn't want to wear prosthesis during the night, he/she can clean
it, dry it and put it into the closed box. If rough surface irritates orbit to product more tears, it
is wise to change the prosthesis.
Patient has right to have two glass prosthesis per year, which are payed by health
insurance. Prosthesis are described by doctor, and approval by revision doctor is not
necessary. In case of prosthesis damage, patient has to pay the new one himself/herself.
Special glass prostheses are recommended to wear from one to one and a half a year.
VII. CSKO 20. 10. 2016
57
Advantages and disadvantages
Glass ocular prostheses are solution of patients who have allergies on acryl ocular
prostheses. They also have quallities like colour stadiness and shine of a natural healthy eye.
Iris seems to be plastic and deep. Manufacture technique creates smooth surface without
protuberances, which makes wearing comfortable. Wettability of the glass is good as well, and
it makes thin slippery film, which protects sensitive conjuctive from harder friction. Moreover,
patient’s prosthesis is manufactured during the appointment, so he/she can wait to pick it up.
In comparison to acryl prostheses, glass ones are more difficult to make. When
prosthesis has contact with eye liquids, which have lower pH, then surface is damaged, and it
makes uncomfortable feeling when wearing. Glass is prone to scratch, mostly by dust or other
kind of dirts that enter under an eyelid and damages prosthesis with grooves.
Main disadvantage of a glass prosthesis is it’s fragility. Prosthesis is damages especially
during putting it out phase when cleaning, but it can be shattered when doing sports or in an
accident. It is important to care about hot temperatures, or elseprosthesis can
crack.Prosthesis is uncomfortably cold during winter, there is also chance for tears to freeze
to the surface of the ball. The only appearance problem is the pupil, which seems like an
artificial ball, and makes unnatural look.
Acryl ocular prostheses
Development
Testing acrylec resin began in USA in 1943. It was necessary to find new materialbecause
the import of glass was suspended. In adition, some characteristics of glass were not fully
complying. From this reason started manufacture of storage acrylate ocular prosthesis in
several shapes and colors of the iris. This prosthesis could not provide adequate comfort for
patients, so it started individual manufacture. Currently acrylate, superpont and
methylmethacrylat are used as amterial for manufacturing prostheses. This base material
comprises 95 % mixture, the remaining 5 % are unknown for public, constantly changing
additives.
Manufacture
Impression patient´s orbit is taken by impression tray. This impression trays are made
from acrylic resin, they have hollow handle, the moulding material is injected . If the
impression is right, the excess material is removed and the periphery of the impression serves
as basis for manufacturing of ocular prostheses.
Pictures 12, 13 and 14: Impression tray, moulding materiál and the
impression
VII. CSKO 20. 10. 2016
58
The impression is used to manufacture the mold. After hardening the mold, its surface
is rebbed by separating material and then molten wax can be poured into the prepared mold.
Wax model is after then check and adjusted to right simulate the lost eye. It´s checking
the correct, size, tissues support, eye´s movement and rigt place eyelids. There are more
methods of manufacture and centration of the iris. The most easy method is choosing the
premade disc, which color is same like the natural contralateral eye. The most dificult method
is painting the iris on the disk with oil colors mixed into the polymethecrylate color medium.
Corneal button is made using a heat-polymerizing acrylic resin. The button size is similar
to the size of the iris disc. It´s connected to the painted iris disc using cryanacrylate glue.
If we have done wax pattern, we continue with manufacture mold from dental stone or
plaster.
Picture 15, 16 and 17: Corneal button, iris disk and and making of mold
The iris disk is placed into this mold and it´s poured by white polymethylmethacrylat. It´s
cured in an oven for 2,5 hours. It ´s kept at 110 °C temperature and at 4 bar pressure. After
curing it´s excess material remove and the prosthesis is ground and polished. It´s possible to
insert prosthesis into a patient´s orbit and check the size and iris location in white base. If the
result is satisfactory, we can start with toning process. Cotton rayon threads are used to give
the appearance of blood vessel appearance. Dry stable natural fine grinded colour pigments
are used to give the exact shade to the sclera corresponding to the patient's fellow eye. Once
it is ensured that the exact colour matching has been achieved, the base of the prosthesis is
kept in the oven at 85 °C for 30 min. This cures the colours to saturation levels and prevents
any future fading. Once the artwork is completed, the shell is put back into mould and a layer
of clear plastic is polymerized on the front surface, completing the fabrication process. After
trimming and polishing, the final prosthesis may need minor adjustments such as adding or
removal of PMMA in different places.
Picture 18 and 19: Polishing of the prostheses and final look
VII. CSKO 20. 10. 2016
59
Service life
It is not precisely defined, how long the prosthesis will last. Modern plastic prostheses
are durable and do not crack. Plastic and pigment quality are gradual degradation. Prosthesis
should be changed every three years. In the case scratching the ocular prosthesis, can be
polished. The prosthesis size can be decrase or increase in dependence of an orbital changes.
The patient has the right to have one prosthesis per three years.
Advantages and disadvantages
Prostheses of a synthetic resin due to the lower hardness of the surface characterized
by greater degree of wear, the surface becomes rough and uneven after a short period of use.
This prostheses have not wettability like the glass prostheses. Acrylic prosthese are however
more resistant to acid tears effect. The disadvantage is also smaller plasticity of iris, on the
other side the pupil look more natural. The manufacture time is longer than manufacture time
glass prostheses. Some patients have alergies to this material. The great advantage is however
less breakage.
Resources
Artopoulou, I.-I. et al. Digital imaging in the fabrication of ocular prostheses. The Journal of
Prosthetic Dentistry. 2006-04, vol. 95, no. 4, p. 327–330. DOI:
10.1016/j.prosdent.2006.01.018.
Darsová, D. Oční protézy u dětí a žáků se zdravotním postižením. Oční klinika dětí a dospělých
UK 2. LF a FN Motol. 2011
Doshi, P., Aruna,B. Prosthetic management of patient with ocular defect. The Journal of Indian
Prosthodontic Society. 2005, vol. 5, no. 1, p. 37–38.
Gliklich, R. E. et al. Combining Free Flap Reconstruction and Craniofacial Prosthetic Technique
for Orbit, Scalp, and Temporal Defects. The Laryngoscope. 1998, vol. 108, no. 4, p. 482–487.
DOI: 10.1097/00005537-199804000-00004.
Goyal, M., Goyal, S., Dhanasekar, B. Modern trends in modeling of extra-oral defects. Indian
Journal of Dental Research. 2014, vol. 25, no. 1, p. 128. DOI: 10.4103/0970-9290.131170.
Guttal, S. S. et al. A Simple Method of Positioning the Iris Disk on a Custom-Made Ocular
Prosthesis. A Clinical Report. Journal of Prosthodontics. 2008-04-01, vol. 17, no. 3, p. 223–227.
DOI: 10.1111/j.1532-849X.2007.00272.x.
Kathuria, N. et al. A modified technique and simplified laboratory procedure for Ocular
Prosthesis Fabrication. Journal of Prosthodontic Research. 2012-04, vol. 56, no. 2, p. 147–150.
DOI: 10.1016/j.jpor.2011.07.002.
Mccord, C. ARTIFICIAL EYES; THE EARLY HISTORY OF OCULAR PROSTHESES. Journal of
Occupational Medicine. 1965-02, p. 61–8.
Patil, S. B. et al. Ocular prosthesis: a brief review and fabrication of an ocular prosthesis for
a geriatric patient. Gerodontology. 2008-03-01, vol. 25, no. 1, p. 57–62. DOI: 10.1111/j.1741-
2358.2007.00171.x.
VII. CSKO 20. 10. 2016
60
Raizada, K., Rani, D. Ocular prosthesis. Contact Lens and Anterior Eye. 2007-07, vol. 30, no. 3,
p. 152–162. DOI: 10.1016/j.clae.2007.01.002.
Waldhegerová, L. Oční protézy. Česká oční optika. 2006, vol. 47, no. 2, p. 44–46. ISSN 1211-
233X.
Muellersoehne. Manufacturing of Ocular Prostheses. F. Ad. Müller Söhne OHG © 2016 [cit.
2016-05-31] Dostupné z: http://www.muellersoehne.com/en/m_tillverkning.htm
VALTERA PROTEŽU LABORATORIJA. Ocular protetics [online]. Scientific Institution „Valters´
Protethic Laboratory“ © 2016 [cit. 2016-05-31]. Dostupné z:
http://www.vpl.lv/eng/ocular_prosthetics/choice_of_prosthesis
ASPIRION. Oční protéza – údržba a často kladené otázky, Nikolaus Kerbl © 2016 [cit. 2016-06-
23]. Dostupné z: http://www.asprion.at/ocni_protezy/casto_kladene_dotazy.html
VII. CSKO 20. 10. 2016
61
Adaptace na tmu v závislosti na věku
Autor: Bc. Veronika Krchňáková
Školitel: Mgr. Pavel Kříž
Úvod
Běhen dne a noci dopadá do oka světlo o různé intenzitě. Schopnost oka se těmto
odlišným hladinám osvětlení přizpůsobit se nazývá adaptace. Oko dokáže rozeznat hladiny
osvětlení v rozmezí zhruba od 0,003 luxů do 80 000 luxů. Abychom si mohli tento rozsah lépe
představit, tak intenzita osvětlení za slunečného letního dne je větší jak 70 000 luxů a za jasné
měsíční noci při úplňku je zhruba 0,5 luxů.
Rozlišujeme dva typy adaptace a to adaptaci na světlo a adaptaci na tmu. K adaptaci
na světlo dochází například při přechodu z tmavší místnosti do světlejší. U adaptace na tmu je
tomu naopak. Pokud jsou změny intenzit malé, tak se oko docela rychle přizpůsobí. Ale pokud
jsou tyto změny velké, tak adaptace trvá delší dobu, hlavně při přechodu ze světlejšího
prostředí do tmavšího. Přizpůsobení se hladinám osvětlení je závislé hlavně na
fotopigmentech tyčinek a čípků. Za světla dochází k rozpadu fotopigmentu tyčinek –
rhodopsinu. Za tmy dochází k jeho resyntéze. Tento děj je podstatou adaptace na tmu.
Adaptace oka na světlo je velice rychlá a je doprovázena zúžením zornic a přivřením víček.
Adaptace na tmu je naopak pomalá. Konečného prahu citlivosti na intenzitu osvětlení je
dosaženo až po 40. nebo 45. minutě. Při adaptaci na tmu dochází nejdříve k přizpůsobení čípků
a následně tyčinek. Adaptace čípků je rychlá (asi do 10 minut), ale málo vydatná. Citlivost
sítnice se zvýší asi 100 krát. Následuje fáze přizpůsobení se tyčinek, která je pomalá, ale
citlivost sítnice se zvýší tak 100 000 krát.
Při adaptaci dochází ke změně funkce sítnice. Když je oko adaptované na světlo, jedná
se o tzv. fotopické vidění. Tohoto procesu se účastní převážně čípky a vidění je ostré a barevné.
Při denním vidění je sítnice nejvíce citlivá na světlo o vlnové délce 555 nm, což odpovídá
žlutozelené barvě. Za tmy pak nastává vidění skotopické. Oko je tedy adaptované na tmu.
Vidění se účastní tyčinky a je nebarevné a neostré. Jelikož se v centru žluté skvrny nachází
pouze čípky, tak vzniká i tzv. centrální skotom. Za tmy je sítnice nejcitlivější na vlnovou délku
světla o hodnotě okolo 500 nm, modrozelená barva. Posun spektrální citlivosti sítnice
ke kratším vlnovým délkám se nazývá Purkyňův jev. Za šera, kdy ještě fungují jak čípky, tak
tyčinky, se vidění označuje jako mezopické.
VII. CSKO 20. 10. 2016
62
Obr. 1: Purkyňův jev
Adaptaci na tmu můžeme měřit pomocí adaptometrů. Jedním z nejznámějších je
Goldmann – Weekersův a Hartingerův adaptometr. Při měření adaptace se nejdříve začíná
preadaptací na světlo a následuje adaptace na tmu, kdy se zjišťuje hraniční osvětlení, kdy
pacient ještě rozezná světlo od tmy. Z měření získáváme adaptační křivku, která má bifázický
tvar. První část odpovídá adaptaci čípků, poté následuje zlom, tzv. Kohlrauschův zářez. Tento
zářez se vyskytuje mezi 3. a 8. minutou a značí přechod z adaptace čípků na adaptaci tyčinek.
Poslední část křivky značí adaptaci tyčinek. Další způsob jak změřit adaptaci je pomocí
nyktometru. Ten však měří pouze rychlou fázi adaptace. Používá se jako screeningové
vyšetření např. u řidičů z povolání.
Obr. 2: Křivka adaptace na tmu
Poruchy adaptace sítnice mohou být buď vrozené, nebo získané. Porucha vidění za šera
neboli hemeralopie se vyskytuje u chorioretinitid, pigmentové retinopatie, u šedého zákalu,
VII. CSKO 20. 10. 2016
63
při onemocnění nervu optiku, při siderore či avitaminose vitaminu A. Zhoršená adaptace
na světlo se může vyskytovat u lidí, kteří mají poruchu v optických médiích (fakosklerom).
Cíl práce a pracovní hypotézy
Ve své práci se zaměřuji na měření adaptace na tmu. Mým cílem je zjistit, zda se
adaptace na tmu mění v různých věkových kategoriích. Pro svou diplomovou práci jsem si
stanovila dvě hypotézy. První hypotéza je, že s přibývajícím věkem se bude práh citlivosti
zvyšovat. Myslím si, že s přibývajícím věkem bude člověk potřebovat čím dál větší hodnotu
jasu, aby tento jas odlišil od tmy. Budu tedy porovnávat jas, kterého vyšetřované osoby
dosáhnou po 45 minutách ve tmě. Druhá hypotéza zní: s přibývajícím věkem se bude
Kohlrauschův zářez vyskytovat později. Myslím si, že adaptace na tmu se bude s přibývajícím
věkem zpomalovat a proto bych chtěla zjistit, zda se bude Kohlrauschův zářez posunovat.
Metodika výzkumu
Pro svůj výzkum jsem si zvolila, že budu vyšetřovat lidi ve věku od 20 do 59 let. Budou
rozděleni do skupin podle věku: 20 – 29 let, 30 – 39 let, 40 – 49 let a 50 – 59 let. Probandi by
neměli trpět oční patologií, jako jsou glaukom, katarakta, VPMD, změny očního pozadí
u diabetiků, aby výsledky nebyly zkreslené. Vyšetřované osoby mohou být jak amatropové,
tak emetropové.
Vyšetření bude probíhat za binokulárních podmínek a naturálního vizu. Měření se
uskutečňuje ve Fakultní nemocnici u sv. Anny na oddělení nemocí očních a optometrie. Měření
probíhá na Hartingerově adaptometru v místnosti bez oken, takže je v místnosti zajištěná
dostatečná tma.
Obr. 3: Hartingerův adaptometr
VII. CSKO 20. 10. 2016
64
Výzkum začíná zjišťováním osobní anamnézy, abych mohla z výzkumu vyřadit osoby
s oční patologií. Následuje měření zrakové ostrosti, které provádím na optotypu, který jsem si
vytvořila, na vzdálenost 4 m. Nejprve zjišťuji visus monokulárně pro pravé a pak pro levé oko
a následně binokulárně. Zaznamenána je hodnota visu, kdy probandi přečtou správně alespoň
60% znaků na řádku. Následuje vlastní měření adaptace na tmu, které probíhá celou dobu
ve tmě. Měření začíná 5 minutovou preadaptací na světlo. Vyšetřovaná osoba si opře bradu
o opěrku a dívá se před sebe do přístroje do osvětlené koule. Po uplynutí této doby je
vyšetřovaná osoba požádána, aby se odklonila od přístroje a posunula se do vzdálenosti 60 cm
od přístroje. Během posunu i pak během celého vyšetření se stále dívá před sebe
do adaptometru. Následuje adaptace na tmu. Probandovi je pouštěno světlo se zvyšujícím se
jasem. Vyšetřovaná osoba má potom ohlásit moment, kdy světlo uvidí. Vyšetřující tento
moment zaznamená do adaptometru, kde se to zaznačí do záznamového grafu.
Obr. 4: Záznamový graf
Stanoví se tím nejmenší jas, který vyšetřovaný ještě odliší od tmy, tzn. práh citlivosti.
Světlo se prvních 10 minut pouští po minutě, dalších 10 minut po dvou minutách a potom po
5 minutách. Část ve tmě trvá 45 minut. Na konci měření získáme adaptační křivku, u níž
posuzujeme dobu, kdy vznikl Kolrauschuv zářez a práh citlivosti dosažený ve 45. minutě.
Dílčí výsledky práce
Doposud se měření zúčastnilo celkem 22 lidí. Z toho bylo 12 mužů a 10 žen. Ve věkové
kategorii 20 – 29 let je 10 lidí (5 mužů a 5 žen, průměrný věk 23,3), ve skupině 30 – 39 let jsou
3 lidi (2 muži a 1 žena, průměrný věk 32,67), ve třetí kategorii 40 – 49 let jsou 3 lidi (2 muži a
1 žena, průměrný věk 46) a v poslední skupině 50 – 59 let je 6 lidí (3 muži a 3 ženy, průměrný
věk 51,3). Probandi jsou bez očních patologií.
Z grafu můžeme pozorovat, že jednotlivé křivky se od sebe moc neliší. Práh citlivosti po
věkovou kategorii dvacátníků dosáhl hodnoty 4,15 log jednotky, u třicátníku bylo dosaženo
hodnoty 4,05 log jednotky, u čtyřicátníků 3,95 log jednotky a nakonec u padesátníků 3,91 log
jednotky. Je tedy vidět, že s přibývajícím věkem je potřeba větší hodnoty jasu, pro to, aby
vyšetřovaný zaznamenal světlo. Nicméně se tyto hodnoty liší velice málo. Proto bych svou
VII. CSKO 20. 10. 2016
65
první hypotézu, která zněla, že s přibývajícím věkem se bude práh citlivosti zvyšovat, prohlásila
za neplatnou.
Graf 1: Křivka adaptace na tmu
Dále jsem zjišťovala, kdy dochází ke vzniku Kohlrauschova zářezu. Z prvního grafu to není
tolik patrné, proto se podíváme na grafy jednotlivých kategorií.
V kategorii dvacátníků vzniká Kohlrauschův zářez v 5. minutě, u třicátníků je tomu ve 3.
minutě, u čtyřicátníků ve 2. minutě a u padesátníků ve 4. minutě. Myslela jsem si, že se tento
zářez bude s věkem vyskytovat později. Zatím se prokazuje, že je tomu spíš naopak. Proto bych
i svou druhou hypotézu prohlásila za nepotvrzenou.
Graf 2: Adaptační křivka kategorie 20 – 29 let
0
1
2
3
4
5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
CitlivostE=log(1/jas)
Čas (min)
Adaptace na tmu
20 - 29 let
30 - 39 let
40 - 49 let
50 - 59 let
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
CitlivostE=log(1/jas)
čas (min)
VII. CSKO 20. 10. 2016
66
Graf 3: Adaptační křivka kategorie 30 – 39 let
Graf 4: Adaptační křivka kategorie 40 – 49 let
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
CitlivostE=log(1/jas)
Čas (min)
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
CitlivostE=log(1/jas)
Čas (min)
VII. CSKO 20. 10. 2016
67
Graf 5: Adaptační křivka kategorie 50 – 59 let
Zdroje
Janovič, A. Vnímání barev [online]. Brno, 2005 [cit. 2016-29-06] Diplomová práce. Masarykova
universita, Pedagogická fakulta. Vedoucí práce Jindřiška Svobodová. Dostupné z:
http://www.ped.muni.cz/wphy/publikace/jancovic1.html
Kallonatis, M., Luu, Ch. Light and dark adaptation [online]. 2015 [cit. 2015-10-06]. Dostupné z:
http://webvision.med.utah.edu/book/part-viii-gabac-receptors/light-and-dark-adaptation/
Kraus, H. Kompendium očního lékařství. 1. vyd. Praha: Grada Publishing, 1997, 341 s. ISBN
8071690791.
Rozsíval, P. Oční lékařství. Vyd. 1. Praha: Galén, 2006, 373 s. ISBN 8072624040.
Synek, S., Skorkovská, Š. Fyziologie oka a vidění. 2., doplněné a přepracované vydání. Praha:
Grada, 2014. ISBN 978-80-247-3992-2.
Kvapilíková, K. Vyšetřování oka. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví,
1995. ISBN 80-7013-195-0.
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
CitlivostE=log(1/jas)
Čas (min)
VII. CSKO 20. 10. 2016
68
Dark adaptation depending on age
Author: Bc. Veronika Krchňáková
Supervisor: Mgr. Pavel Kříž
Introduction
The light falls to the eye with a different intensity during the night and day. An ability of
the eye to adapt these different levels of the illumination is called adaptation. The eye can
recognize the illumination in a range from 0,003 luxs to 80 000 luxs. For a better imagination,
the intensity of the illumination of the sunny day is bigger than 70 000 luxs and the intensity
of the illumination of the bright moonlight night under a full moon is about 0,5 luxs.
We can distinguish two types of the adaptation, it is adaptation to the light and
adaptation to the night. Adaptation to the light can occur for example in transition from darker
room to lighter. In dark adaptation is the opposite. When the changes of the adaptation are
small the eye can quickly adapt. But when the changes are bigger the adaptation take a longer
time mainly in transition from lighter room to darker. The adaptation to the level of the
illumination depends mainly on photopigmnents of the rods and cones. The photopigments
of the rods - rhodopsin crumble in the light. In the dark leads to its resynthesis. This action is
the essence of the dark adaptation. Light adaptation of the eye is really quick and it is
accompanied of tne miosis and of closing of eyelid. Adaptation to the dark is on the other
hand slow. Final threshold of sensitivity to light intensity is achieved after 40. or 45. minutes.
In dark adaptation cones can adapt first and than rods. Adaptation of the cones is fast (about
to 10 minutes) but it is small. The sensitivity of the retina is increase of hundreds of times.
Next phase is adaptation of the rods which is slow but the sensitivity is increase 100 000 times.
The function of the retina is changed during the adaptation. When the eye is adapted to
the light it is called photopic vision. Mainly cones participate of this action and the vision is
sharp and color. The retina is the most sensitive on the light with wavelength 555 nm witch
correspond to the yellow – green color in photopic vision. The scotopic vision occurs in the
dark. The eye is adapted to the dark. Rods attend to the vision which is not sharp and which
is uncolor. There are only cones in the macula lutea so the the central scotoma is appeared.
Spectral sensitivity of the retina is moved to the shorter wavelength which is 500 nm, blue –
green color. The action is called Purtkyně's phenomenon. The vision is called mesopic when is
dusk. The cones and also rods work.
VII. CSKO 20. 10. 2016
69
Picture 1: Purkyňe's phenomenon
We can measure dark adaptation with help adatometer. One of the famous
adaptometer is Doldmann – Weekers's and Hartinger's adaptometer. At first the
measurement starts with preadaptation to the light and then the adaptation to the dark
follows when we have to find out a border illumination when the patient distinguish the light
from the dark. We get adaptation curve from the measurement which has biphasic shape. The
first part corresponds to the adaptation of the cones than a break follows which is called
Kohlrausch's cut.
Picture 2: Dark adaptation curve
The cut appeards between 3. and 8. Minutes. The next possibility how to measure the
adaptation is with help nyctometer. It measure only fast phase of the adaptation. It is used as
the screening measurement for example for professional drivers.
Fotopic vision
Scotopic vision
Wavelenght
VII. CSKO 20. 10. 2016
70
A disorders of adaptation can be congenital or obtained. The disorder of the scotopic
vision is called hemeralopia. It can occurred in chorioretinitis, retinopathia pimentosa,
glucoma, disease of the nervus opticus, siderosis, vitamin deficiency of the vitamin A. The
impaired adaptation to the light can have people who have the disorder of the optical media
(facosclerom).
Object of the thesis and working hypothesis
I concentrate to the measurement of the dark adaptation in my thesis. My target is to
find out if the dark adaptation is changed in different age categories. I determine two
hypothesis for my thesis. The first hypothesis is that the sensitivity treshold will increase with
aging. I think that the person will need bigger value of the luminance with aging that he
distinguish the lminance from the dark. I will compare the luminance which the probands
reach after 45. Minutes in dark. The second hypothesis is that tka Kohlrausch's cut appear
later with aging. I think that dark adaptation will be slower with ahing and so I would like to
find out if the Kohlrausch's cut will move.
Methods of the research
I chose that I will measure the people from 20 to 59 age for my research. Thy will be
separate to the group depend on the age: 20 – 29 age, 30 – 39 age, 40 – 49 age and 50 – 59
age. The probands should not have an eye pathology like glaucoma, cataract, ARMD, changes
of the fundus in diabetic that the results will not distorted. The which I will measure can be
ametrops and also emetrops.
The measurement will under binocular condition and natural visus. The measurement
takes place at University hospital at st. Anna at the department of ophthalmology and
optometry. The measurement will be made on Hartinger's adaptometer. (Picture 3) in the
room without the windows so the dark will in the room.
Picture 3: Hartinger's adaptometer
VII. CSKO 20. 10. 2016
71
The research starts find out of the personal anamnesis that I can discard people with
ocular pathology from my thesis. The measurement of the visual acuity follows which I will do
on optotype which I made for a distance 4 m. At first I find out visual acuity under monocular
condition for right and left eye than under binocular condition. The value of visus is wrote
down when the probands read correctly at least 60 % of the symbol in the line. The
measurement of the dark adaptation follows which is done in the dark during the
measurement. The measurement starts with preadaptation to the light which take 5 minutes.
The person which is measured give his chin on the prop and he looks straight to the
adaptometer which id lighting. After 5 minutes the person is asked to move to the distance 60
cm from adaptometer. He still looks straight to the light during the moving and whole
measurement. The dark adaptation follows. The light is turn on and I change the luminance
from the lowest to the biggest. The proband have to say the moment when he see the light.
The moment I register to the adaptometer to the recor graph.
Picture 4: Record graph
The lowest luminance which the proband distinguish from the dark is wrote down, it
means the sensitivity treshold. The light turn on first 10 minutes every one minutes, next 10
minutes every two minutes and then every five minutes. The part in the dark takes 45 minutes.
At the end of the measurement we will get the adaptation curve where we judge the time
when the Kohlrausch's cut appear and we judge the sensitivity treshold which were reached
at 45. minutes.
The partial results of the thesis
I have measured 22 peoples yet of which 12 were men and 10 were women. I have 10
people in the category 20 – 29 age (5 men and 5 women, average age is 23,3), 3 people in
category 30 – 39 age (2 men and 1 women, average age is 32,67), 3 people in category 40 –
49 age (2 men and 1 women, average age is 46) and 6 people in the last category 50 – 59 ages
(3 men and 3 women, average age is 51,3). Probands are without ocular pathology.
VII. CSKO 20. 10. 2016
72
In the graph 1 we can see that the curves is not so different. The sensitivity treshold
reached 4,15 log unit for 20s, 4,05 log unit for 30s, 3,95 log unit for 40s and 3,91 log unit for
50s. We can see that it is need bigger value of the luminance for distinguish the light from dark
with aging. But the value is not so different so I should say that the first hypothesis which says
that the sensitivity treshold will increase with aging is declared invalid.
Grap 1: Dark adaptation curve
I also analyzed when the Kohlrausch's cut appears. It is not so clear to see from the first
graph so we have to take a look at the graphs of each category. The Kohlrausch's cut appears
at minute 5 in category of 20s, at minute 3 in category of 30s, ate minute 2 in category of 40s
and at minute 4 in category of 50s. I thought that the cut would appear later with aging. But
result show, that it is the opposite. Which means that I have to declare my second hypothesis
as not confirmed.
Graph 2: Adaptation curve of category 20 – 29 ages
0
1
2
3
4
5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
SensitivityE=log(1/jas)
Time (min)
Dark adaptation curve
20 - 29 let
30 - 39 let
40 - 49 let
50 - 59 let
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
IntensityE=log(1/jas)
Time (min)
VII. CSKO 20. 10. 2016
73
Graph 3: Adaptation curve of category 30 – 39 ages
Graph 4: Adaptation curve of category 40 – 49 ages
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
IntensityE=log(1/jas)
Time (min)
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
IntensityE=log(1/jas)
Time (min)
VII. CSKO 20. 10. 2016
74
Graph 5: Adaptation curve of category 50 – 59 ages
Resources
Janovič, A. Vnímání barev [online]. Brno, 2005 [cit. 2016-29-06] Diplomová práce. Masarykova
universita, Pedagogická fakulta. Vedoucí práce Jindřiška Svobodová. Dostupné z:
http://www.ped.muni.cz/wphy/publikace/jancovic1.html
Kallonatis, M., Luu, Ch. Light and dark adaptation [online]. 2015 [cit. 2015-10-06]. Dostupné z:
http://webvision.med.utah.edu/book/part-viii-gabac-receptors/light-and-dark-adaptation/
Kraus, H. Kompendium očního lékařství. 1. vyd. Praha: Grada Publishing, 1997, 341 s. ISBN
8071690791.
Rozsíval, P. Oční lékařství. Vyd. 1. Praha: Galén, 2006, 373 s. ISBN 8072624040.
Synek, S., Skorkovská, Š. Fyziologie oka a vidění. 2., doplněné a přepracované vydání. Praha:
Grada, 2014. ISBN 978-80-247-3992-2.
Kvapilíková, K. Vyšetřování oka. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví,
1995. ISBN 80-7013-195-0.
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0 1 2 3 4 5 6 7 8 9 10 12 14 16 18 20 25 30 35 40 45
IntensityE=log(1/jas)
Time (min)
VII. CSKO 20. 10. 2016
75
The cornea, sclera and conjunctiva tarsal –
Gradation degrees
Authors: Sara Lončar, Dorotea Prguda
Abstract
Changes on the eye, or to be more exact, on the sclera, cornea and tarsal conjunctiva,
are interpreted from the gradations. By gradation degree or intensity of gradation, changes
on the eye are determined, and those changes can be caused by foreign body in the eye,
contact lenses or other factors.
Rhythm of the life of people in the 21st century, leads to the situation that they do not
pay enough attention to their own health. Looking from a point of view of an professional
optometrist, one of the mistakes that clients do, is that they buy, at their own risk, contact
lenses and cleaning solutions over the internet, without proper care that optometrists give
and that is required for contact lens wearers. This can cause different eye health problems.
Furthermore, staying in environmentally polluted areas very much affects the eye.
All of those can cause allergies, conjunctivitis or keratitis, which are manifested as
redness, enlarged blood vessels, small bulges and other conditions that can appear on tarsal
conjunctiva, sclera and the cornea.
Examination
For the inspection of cornea, sclera and conjunctiva tarsal, biomicroscope is used.
Conjunctiva tarsal and cornea are inspected with fluorescein, under the blue light and yellow
filter settings on the biomicroscope.
Cornea, conjunctiva tarsal and sclera are inspected during general inspection of the eye
which is the first examination that is done under the biomicroscope.
If blood vessels are to be inspected, as they are most common change on the sclera, red
free filter is used. Under the red free filter is visible if there are any new blood vessels,
hyperemia (increased blood supply) and other diseases of the sclera. It would be manifested
with widen blood vessels, redness, accumulation of inflammatory cells and increased
secretion from the eye.
Conjunctiva tarsal and cornea are divided into five areas and sclera into six, all marked
with numbers, by which is determined what area is affected with an infection, inflammation
or similar.
The tarsal conjunctiva is checked by ectropion of the eyelid. It is performed in the way
that upper eyelid is inverted upwords to see is there is a presence of a foreign body in the eye
or suspicion of an inflammation, such as conjunctivitis.
VII. CSKO 20. 10. 2016
76
An unsuitable material of contact lens can cause GPC (Giant Papillary Conjunctivitis), but
this disease can also be caused by allergy to the proteins in the contact lenses cleaning solution
and first signs would be visible on tarsal conjunctiva.
Folicular conjunctivitis is an inflammation of conjunctiva caused by a bacteria. Small
knots appear on the conjunctiva and those changes are visible on the sclera as well.
Intensity of the colour and the size of blood vessels on tarsal or sclera show if there are
any deviations from the normal healthy condition of the eye.
With fluorescein to the eye, under the biomicroscope is visible if there are any
abnormalities, such as bumps or clusters.
On the cornea, corneal stippen and erosions can be found and seen, which is also
examined with biomicroscope under blue light an yellow filter, with use of fluorescein. Stippen
on cornea are positioned on “3, 9 or 6, 12 hours”.
Results
Grade 1 Grade 2 Grade 3 Grade 4
Chart 1: Principles of grading scales
Conjunctiva tarsal
Picture 1: Classification of conjunctiva tarsal on 5 areas
NORMAL BORDERLINEE ABNORMAL
VII. CSKO 20. 10. 2016
77
Picture 2: GPC Giganto Papilare Conjunctivitis zone 1, intensity 4.
Picture 3: Injection of blood vessels of conjunctiva tarsal, zone 2, intensity 1.
Picture 4: Follyculare conjunctivitis, zone 1 and 4, intensity 4.
Cornea
Picture 5: Classification of cornea on 5 areas
VII. CSKO 20. 10. 2016
78
Picture 6: Cornea stippen zone 5, intensity 1.
Picture 7: Cornea stippen zone 5 and 2, intensity 2
Sclera
Picture 8: Irritated sclera
Picture 9: Classification of sclera in 6 areas
VII. CSKO 20. 10. 2016
79
Picture 10: Bulbar injection of blood vessels intesity 2,zone 6
Picture 11: Bulbar injection of blood vessels, intensity 3 zone 6
Picture 12: Bulbar injection of blood vessels, intesity 4,zone 6
Conclusion
The human eye is sensitive to all the changes taking place around it, and it is important
at the beginning of the general inspection of the eye to ask the client for the changes that they
may noticed. Gradation show how serious condition of the client is.
If the client wears contact lenses, optometrist has a duty to advise him what kind of
materials they should use and the type of cleaning solution. Special attention should be paid
to reviewing the eyelids and client advised to have regular follow ups. These tips prevents
diseases and eye infections such as conjunctivitis and keratitis.
VII. CSKO 20. 10. 2016
80
Resources
Benčić, D., Dona, I., Raizner, A., Tocilj, P., Vrebčević, Z., Vretenar, P. Leksikon očne optike i
optometrije, Zagreb, 2006.
Gavrić N., Čupak K., Cerovski B. Oftalmologija, Zagreb ,2004.
Poltner Gustav, Slitlamp. Kontaktne leće 1., Veleučilište Velika Gorica, Očna optika.Velika
Gorica, March 2016. [Lecture]
Schweizer Helmer, Material for contact lenses, Kontaktne leće 1., Veleučilište Velika Gorica,
Očna optika, Velika Gorica, April, 2016. [Lecture]
VII. CSKO 20. 10. 2016
81
Snášenlivost vertikálního prizmatu
Autor: Bc. Jolana Nedvědová
Školitel: Mgr. Matěj Skrbek
Abstrakt
Práce pojednává o vzniku a účincích spřaženého vertikálního prizmatu. Shrnuje
geometrii progresivní čočky, popis prizmatického ztenčování brýlových čoček a rozbor
krátkodobé objektivní snášenlivosti vertikálního prizmatu při každodenních činnostech. Vliv
prizmatu byl měřen na vzorku české populace, byly stanoveny základní hypotézy vlivu
prizmatu na vnímání člověka a průběžné výsledky byly shrnuty v závěru textu. Měření
probíhalo na různých typech činnosti. Jednalo se o činnost statickou, dynamickou a činnost
testující opto-motorickou koordinaci. Z částečných výsledků vyplývá, že spřažené vertikální
prizma má vliv na rychlost čtení a přesnost hodu na cíl. Vliv na rychlost chůze se nepodařilo
prokázat.
Úvod
Vertikální prizma před okem může vzniknout několika způsoby. Využívá se jako korekce
heteroforií či heterotropií, vzniká při prizmatickém ztenčováních progresivních čoček, nebo se
objevuje jako vedlejší produkt chybné vertikální centrace čočky. Tento text se bude zabývat
metodou prizmatického ztenčení progresivních čoček, které se využívá pro snižování váhy a
zlepšení jejich estetiky. Za předpokladu, že je progresivní čočka vybrána klientovi dobře,
mohou představovat vzácné případy, kdy se klient korekci nepřizpůsobí, záhadu pro optiky,
optometrista i pro oční lékaře. Zvláště v případech, kdy klient v minulosti progresivní čočky
bez problémů nosil. Cílem tohoto textu je popsat prizmatické ztenčení čoček jako jednu
z příčin neschopnosti adaptace klienta na korekci a zabývat se i krátkodobou adaptací na
vertikální spřažené prizma (VYP z angl. Vertical Yoked Prism).
Geometrie progresivní čočky
Progresivní čočka se vyznačuje plynulou změnou dioptrické hodnoty bez viditelného
přechodu. Je určená pro pohodlné vidění na všechny vzdálenosti. To je zajištěno měnícím se
zakřivením čočky, čímž dochází ke změně její vrcholové lámavosti.
Obrázek 1: Měnící se zakřivení progresivní čočky
VII. CSKO 20. 10. 2016
82
Na příčném řezu spojnou progresivní čočkou můžeme vidět, že v důsledku většího
zakřivení zóny do blízka vzniká čočka se silnějším horním okrajem a užším spodním okrajem.
Rozptylné progresivní čočky pro myopy mají minimální tloušťku poblíž centra blanku.
Obrázek 2: Příčný řez spojnou progresivní čočkou. Čočka má silnější horní
okraj a slabší spodní okraj
Prizmatické ztenčení
Pro vyrovnání tloušťky u horního a spodního okraje čočky se používá technika zvaná
prizmatické ztenčení. Dochází k přidávání prizmatu k vrcholové lámavosti čočky.
Obrázek 3: Prizmatickým tenčením čočky vzniká prizma orientované bází
dolů
Jeho hodnota se udává v prizmatických dioptriích (cm/m) a obecně bývá přibližně 2/3
hodnoty adice. Hodnota prizmatu se měří v prizmatickém referenčním bodě čočky, který je
obvykle shodný s geometrickým středem čočky.
VII. CSKO 20. 10. 2016
83
Obrázek 4: Centrovací a referenční body progresivní čočky
Hodnota prizmatického ztenčení by neměla překročit hodnotu 2,00 pD bází dolů.
Metodou prizmatického ztenčení čočky s vrcholovou lámavostí segmentu do dálky +2,0 D a
adicí 2,0 D je možné redukovat její tloušťku až o 21 %. [1]
Přesné určení geometrie čočky s prizmatickým ztenčením se provádí s pomocí
výpočetního programu v laboratoři. Výpočet hodnoty prizmatického ztenčení je funkcí
vrcholové lámavosti čočky v segmentu do dálky, použité adice, vertikální centrace čočky před
okem, decentrace čočky v brýlové obrubě a velikosti a tvaru vybrané obruby.
Ztenčené progresivní čočky obsahují spřažená prizmata bází dolů (BD) o stejné hodnotě,
která je aplikována před obě oči. Spřažené v tomto smyslu znamená, že prizma posouvá
obrazy před oběma očima o stejnou hodnotu a ve stejném směru. Tím vyloučíme výskyt
rozdílu vertikálních prizmat mezi oběma očima. [2]
Snášenlivost vertikálního prizmatu nositeli brýlové korekce
Posunutí obrazu je zpravidla malé a mezi oběma očima stejné. Proto si většina jejich
nositelů tento posun ani neuvědomí. Nicméně malé množství klientů pravděpodobně
registruje i tyto nejmenší změny. Citliví klienti si při nasazení korekce s prizmatickým efektem
zvýšeným proti předchozímu stavu stěžují na naklonění podlahy směrem k nim, což je
způsobeno posunem obrazu nahoru. Tento klient má pocit, jako by šel neustále z kopce, nebo
bude naklánět hlavu dolů, aby se díval neustále přes oblast do dálky. Podobně tak, citlivý
klient, kterému byl při ztenčení prizmatický efekt snížen, může mít potíže s nalezením zóny do
blízka nebo mu bude připadat v obrubě příliš nízko. Obecně platí, že tyto reakce nejsou běžné,
ale u určitého procenta klientů k nim dochází. [3]
Zajímavým aspektem prizmaticky ztenčených čoček je zvýšené vidění tzv. duchů
(ghosting). Prizmatické ztenčení zesiluje přítomnost fenoménu duchů natolik, aby ho uživatel
vnímal a byl mu nepříjemný. Tento jev může být ale snadno eliminován pomocí antireflexní
vrstvy. [2]
Důležitou otázkou je, jak velká hodnota VYP je pro klienta obvykle přijatelná. Tuto otázku
si kladli i Sheedy a Parsons ve své studii [4], kde zkoumali efekt dlouhodobého nošení VYP na
držení těla a jeho toleranci nositeli. Účastníci studie vybírali mezi 0 pD a 2 pD. 46% z nich
VII. CSKO 20. 10. 2016
84
subjektivně zvolilo 2 pD před plan čočkou, přestože i tento optický klín měl významný vliv na
jejich držení těla. Při výběru mezi 0 pD a 4 pD si už prizmatickou čočku nevybral nikdo. Důvody
odmítnutí 4pD BD hranolu vyšetřovanými zahrnovaly bolesti hlavy, únavu očí, zkreslení
vnímaného obrazu, nepříjemné odrazy a prostorovou dezorientaci. Důvody pro preferenci 2
pD jsou nejasné, ale může jít o placebo efekt. [4]
Cíl práce a pracovní hypotézy
Provedené zahraniční studie zjistily nezanedbatelný vliv VYP na vidění. Cílem této práce
je ověření krátkodobého vlivu VYP na každodenní činnosti na vzorku české populace. K tomuto
účelu byly vybrány tři typy činností: statická – čtení, dynamická – chůze a opto-motorická
koordinace – hod na cíl.
První hypotézu H1 definujeme tak, že s vyšším prizmatem umístěným vyšetřovanému
před oko, bude číst vyšetřovaný pomaleji a bude dělat v textech více chyb. Druhá hypotéza H2
zní, že, s vyšším prizmatem bude vyšetřovaný házet na cíl méně přesně a pomaleji. Podle
hypotézy H3 bude chůze vyšetřovaného méně pravidelná a pomalejší.
Kritéria výběru vzorku
Do výběru vzorku byli zařazeni pouze jedinci bez oční patologie, s ametropií do 1,0 D
včetně, a maximálním astigmatismem 1,5 D. Všichni vyšetřovaní s vertikální heterotropií nebo
hetertoforií byli dopředu vykorigováni.
Metodika
Ve výzkumné části jsou aplikována VYP o velikosti 0, 1, 3 a 5 pD BD. Všechny tři úkoly
odpovídající hypotézám H1, H2, H3 byly mezi sebou pravidelně střídány vždy s náhodně
vybranou hodnotou VYP, aby se statisticky vyloučil efekt učení. Vyšetřovaným byly vždy
poskytnuty 2 minuty na adaptaci s daným prizmatem. Při úkolu čtení se čte pět textů
v náhodném pořadí, čímž se sníží pravděpodobnost vlivu rozdílné náročnosti jednotlivých
textů. Při tomto měření je zaznamenáván počet chyb ve čtení a celkový čas. Ve druhém úkolu
házejí vyšetřovaní vždy 10 míčků na cíl ve stále stejné vzdálenosti. Vzdálenost se určí tak, aby
bez prizmatu zasáhl vyšetřovaný cíl v 50 - 80 % hodů. U tohoto měření je zaznamenáván čas
každého hodu a jejich úspěšnost. Při těchto dvou úkolech je 0 pD vždy první a poslední
měřenou hodnotou. Posledním měřeným úkolem je chůze. Vyšetřovaný jde po schodech
s akcelerometrem připevněným k noze, který snímá rychlost jednotlivých kroků.
Průběžné výsledky práce
Závislost rychlosti čtení na hodnotě předřazeného prizmatu je zobrazena na
následujícím grafu.
VII. CSKO 20. 10. 2016
85
Graf 1: Závislost normovaného času čtení vztaženého k 1. pokusu s 0 pD
Závislost průměrného počtu chyb, které vyšetřovaní udělali v jednom textu v závislosti
na hodnotě předřazeného prizmatu je zobrazená na grafu č. 2.
Graf 2: Závislost průměrného počtu chyb v textu na hodnotě předřazeného
prizmatu.
Závislost průměrného počtu přesných zásahů na hodně prizmatu předřazeného před
oko vyšetřovanému je zobrazená na grafu 3.
94,0
96,0
98,0
100,0
102,0
104,0
106,0
108,0
110,0
112,0
0 1 3 5 0
100,0
104,9
108,2
111,8
100,9
rychlostčtení(%)
hodnotaprizmatu
Normovaný čas čtení vztažený k prvnímu pokusu s 0 pD (%)
0,00
0,20
0,40
0,60
0,80
1,00
0 1 3 5 0
0,73 0,73
0,88
0,69
0,62
početchyb
hodnotaprizmatu
Průměrný počet chyb na 1 text
VII. CSKO 20. 10. 2016
86
Graf 3: Závislost počtu přesných zásahů na hodnotě VYP
Graf 4 znázorňuje časy hodů každého z deseti míčků v sekundách. Barevnými sloupci
jsou vyznačeny hody pro porovnání mezi jednotlivými prizmatickými hodnotami
Graf 4: Závislost rychlosti hodu každého míčku v sekundách na hodnotě VYP
Na grafu č. 5 je vyjádřena závislost průměrné doby jednoho kroku vztažené k hodnotě
vertikálního spřaženého prizmatu. Rychlost kroku je vyjádřena v procentech, kdy za základní
hodnotu 100 % je považováno 0 pD. Modrá linka znázorňuje chůzi ze schodů a červená do
schodů.
0,0
1,0
2,0
3,0
4,0
5,0
6,0
7,0
0 1 3 5 0
6,0
4,8
3,8 3,8
6,0
početzásahů
hodnotaprizmatu
Průměrný počet zásahů
0,00
5,00
10,00
15,00
20,00
25,00
1 2 3 4 5 6 7 8 9 10
sekundy
číslo pokusu
0pD
1pD
3 pD
5 pD
0 pD2
VII. CSKO 20. 10. 2016
87
Graf 5: Závislost Průměrné doby jednoho kroku vztažené k hodnotě VYP
vyjádřená v procentech.
Shrnutí
Průběžné výsledky ukazují, že hypotéza H1 a H2 se potvrzují. Naproti tomu hypotéza H3
se zdá být neprůkazná. Tyto výsledky jsou předběžné a následně budou podloženy analýzou
většího vzorku vyšetřovaných, aby se zvýšila statistická průkaznost měření. Měření bylo
prováděno s cílem zjištění krátkodobé adaptace na VYP a je pravděpodobné, že
v dlouhodobém měřítku by se výsledky lišily. Téma snášenlivosti spřažených vertikálních
prizmat jejich nositeli je široké. Nabízí potenciál k dalšímu zkoumání VYP na držení hlavy a
celého těla, nebo na změnu schopnosti rovnováhy jeho nositele.
Zdroje
[1] Meslin, D. Progressive lenses, Listy očních optiků: Essilor academy Europe, Paris, 2006,
[vid. 27-6-2016] ISBN 979-10-90678-07-1, [Online], Dostupné z:
http://www.zkcoo.cz/files/Cahier-Progressive%20Lenses-CZ.pdf
[2] Meister, D. Understanding Prism-Thinning, Lens Talk, [Online], 1998, [vid. 2-6-2016], Vol.
26, No. 35, Dostupné z: http://www.dicoptic.izispot.com/Files/thinpsm.pdf
[3] Hanlin, P.Prism thinning and progressive addition lenses, 20/20, magazine [Online], 2008,
[vid. 12-3-2016] Dostupné z: http://www.2020mag.com/
[4] Sheedy, J. E., Parsons, S. D. Vertical yoked prism-patient acceptance and postural
adjustment, Ophthalmic & Physiological Optics: The Journal Of The British College Of
Ophthalmic Opticians (Optometrists) 1987, MEDLINE Complete [Online], [vid. 26-1-2016]
255–257, Dostupné z: http://eds.a.ebscohost.com.ezproxy.muni.cz/
100,0
104,1
105,3 105,7
100,0
102,2 102,5
104,1
99,0
100,0
101,0
102,0
103,0
104,0
105,0
106,0
0 1 2 3 4 5
průměrnýčaskroku(%)
hodnotaprizmatu
Průměrná doba jednoho kroku (%) dolů nahoru
VII. CSKO 20. 10. 2016
88
The Tolerance of Vertical Prism
Author: Bc. Jolana Nedvědová
Supervisor: Mgr. Matěj Skrbek
Abstract
This thesis discusses the origin and effects of the Vertical Yoked Prism (VYP). It
summarizes the geometry of the progressive lenses, describes the prism thinning of the
progressive lenses and analyses the objective short-term tolerance of people performing daily
activities to the vertical prism. The Vertical Yoked Prism Effect was measured on a sample of
the Czech population, the basic hypotheses of the prismatic effect on the human perception
were defined, and the partial results were summarized at the end of the article. The
measurement was carried out on various types of activities - a static and dynamic activities
and the activity testing an opto-motoric locomotion coordination. The partial results show
that the VYP has an effect on the reading speed and the accuracy of the shooting the target.
An effect on the walking speed was not proved.
Introduction
Vertical prism in front of the eye can occur in several ways. It is used as a correction for
heterotropia or heterophoria, arises when prism thinning method is applied to the progressive
lenses, or appears as a by-product of an improper vertical center (axis) alignment of the lens.
This text reports on the prism-thinning method of progressive lenses which is used to reduce
the weight and improve their aesthetic. Assuming that the progressive lens was selected to a
client properly, there can be rare cases where the client does not adapt to the correction. It
can be a mystery for opticians, optometrists and the eye doctors. Especially in cases, when the
client worn progressive lenses in the past without any problems. The aim of this paper is to
describe the prism-thinning progressive lenses impact on a client adaption on a lens
correction. Additionally it deals with short-term adaptation to the VYP.
Vertical prism
Created intentionally, as a correction to the client with heterotropia or heterophoria,
and is used as a method of thinning progressive lenses, or arise unintentionally in incorrect
vertical lens centration. I would like to describe the second case, in which is the prism thinning
use for the weight reduction of progressive lenses and improve their aesthetics design.
Geometry of Progressive Lenses
A progressive lens is characterized by continuous change of dioptric values without a
visible transition step. It is designated for comfortable vision at all distances. This is ensured
by the variable curvature of the lens which leads to its variable refractive power (depicted in
Fig. 1).
VII. CSKO 20. 10. 2016
89
Figure 1: Variable curvature of the progressive lens
A cross-section of a progressive lens shown in Fig. 2 explains how the increased
curvature of the near vision zone results into a stronger top edge and a narrower lower edge
of the lens. The progressive diverging lenses for Myopia have a minimum thickness near the
center of the blank.
Figure 5: A cross section of a progressive lens. The lens has wider top edge
and a narrower lower edge.
Prism thinning
To equalize the thickness of the upper and lower edges of the lens a conventional
technique, called the prism thinning, is used. A prism is added to the refractive power of the
lens.
Figure 6: Prism-thinning generates a base down
VII. CSKO 20. 10. 2016
90
Its value is measured in prism diopters (cm/m) and it is generally about 2/3 of the
addition value. The prism value is measured at the reference point of the lens which is usually
placed in the geometric center of the lens.
Figure 7: Fitting and reference points of progressive lens
The value of a prism thinning should not exceed 2.00 pD base down (BD). Application of
the prism thinning method on a lens with the refractive power in far zone of +2.0 D and the
addition of 2.0 D can result in reduction of its thickness by up to 21%. [1]
The accurate geometry of the lens with the prism thinning is calculated by a specialized
computer program in a laboratory. This calculation is a function of the refractive power in the
far zone of the lens, addition, vertical centeration of the lens regarding the eye, the center
offset in respect to the frames, and their size and shape.
The thinned progressive lenses contain the equivalent vertical yoked prims (VYP) BD
which is applied for both eyes. Yoked prims in this context mean that they shift the entire field
of the view of the same amount and in the same direction. This ensures no difference of the
VYP between the eyes. [2]
Tolerance of Spectacle Correction Wearer to VYP
The shift of the view field is small and the same for the eyes. Therefore the most wearers
of the thinned prism lenses do not notice the shift. However few clients probably perceive
even the slightest changes of their eyeglass correction. These sensitive clients who have been
provided with the increased VYP correction in comparison to their former corrections
complain about a floor tilted upwards which is caused by the shift of the perceived image
upwards. These clients have permanent feeling of going downhill or they incline their heads
down to look through the far zone of the lenses. Similarly, the sensitive clients who have been
provided with the decreased VYP may have troubles finding the near zone of the lenses or
they find the near zone to be excessively low in the frames. Generally, these effects are not
usual, but few clients are still affected by them. [3]
VII. CSKO 20. 10. 2016
91
An interesting effect of the prism thinned lenses is increase in seeing ghosts (ghosting).
The prism thinning increases the presence of the ghosting phenomenon enough to be
perceptive and uncomfortable for the lenses wearers. This phenomenon can be easily
eliminated by an anti-reflection layer. [2]
An important question is what the maximum VYP is usually accepted by the clients.
Sheedy and Parsons developed that question in [4] when they examined how the long-term
wearing of the VYP affects the body and head posture and tolerance of the wearers. The
examined wearers voted between 0 pD and 2 pD. The 46% of them subjectively chose 2 pD in
preference of plan lenses. Additionally they voted between 0 pD and 4 pD and nobody
preferred the 4pD lenses to 0 pD. They refused 4 pD lenses as they caused a headache, eye
strain, distortion of the perceived view, annoying reflections, and a spatial disorientation.
Reasons for the preference 2pD are unclear, but it could be a placebo effect. [4]
Aim and Hypotheses of the Work
The international research articles report not negligible effect of the VYP on the human
vision. The aim of this work is to verify the reported VYP effects on every-day activities also on
the Czech population sample. For this purpose three types of activities were selected: static –
reading; dynamic – walking; and opto-motoric coordination – shooting the target.
The first hypothesis H1 is defined as the greater VYP is applied, the examined reads
slower and makes more mistakes in reading. The second hypothesis H2 is that the examined
shoots the target in lower frequency and less successfully. Finally, the hypothesis H3, the
examined walking is slower and less regular.
Criterions of Sample Selection
Only persons without eye pathology, with ametroipa up to 1.0 D, and maximum
astigmatism of 1.5 D were permitted for the examination. Everybody suffering from vertical
heterotropia or heterophoria was compensated before the examination.
Methodology
For practical research part of this work, the VYP of 0, 1, 3, and 5 pD BD are applied. All
the used tasks corresponding to the hypotheses H1, H2, H3 were regularly alternated and
randomly selected. VYP used to statistically eliminate the learning effect. The examined
adapted for two minutes to the new VYP every time VYP changed. Regarding the first task, the
five texts are read in a random order which decreases the influence of varying difficulties of
particular texts in statistical analysis. The number of made mistakes and total reading time is
measured and noted during this test. During the second task, the examined shoots 10 balls in
a target from a defined distance. The distance is defined individually to success rate be from
50 to 80% without the VYP. The time of each shot and its success is recorded. When examining
these two tasks, the VYP of 0 pD is the first and the last once again. The final test is walking.
The examined walks on the stairs with an accelerometer which records the frequency of his
steps.
Continous results
Dependence of the speed reading on value of the prism is shown in Graph 1.
VII. CSKO 20. 10. 2016
92
Graph 1: Dependence of the reading speed on value of the VYP
Dependence of the average number of errors that the examined made in one text on
the value of the prism is shown in Graph 2.
Graph 2: Dependence of the average number of errors in reading of a one
text on the value of the VYP
Dependence of the average number of precise hits on the prism positioned in front of
the examined’s eye is shown in graph 3.
94,0
96,0
98,0
100,0
102,0
104,0
106,0
108,0
110,0
112,0
0 1 3 5 0
100,0
104,9
108,2
111,8
100,9
readingspeed(%)
value of the VYP
Standardized reading time relative to the first attempt with
0 pD (%)
0,00
0,20
0,40
0,60
0,80
1,00
0 1 3 5 0
0,73 0,73
0,88
0,69
0,62
numberoferrors
value of the VYP
Average number of errors
VII. CSKO 20. 10. 2016
93
Graph 3: Dependence of the average number of precise hits on the VYP
positioned in front of eyes
Graph 4 shows the times of each thrown ball in seconds. Bar colors represents different
prism values.
Graph 4: Times of each thrown ball in seconds.
Raph 5 expresses the dependence of the average step time on the VYP. The time of the
step is expressed in percentage, when as a base value of 100% is considered 0 pD. The blue
and red lines show walking down and up the stairs respectively.
0,0
1,0
2,0
3,0
4,0
5,0
6,0
7,0
0 1 3 5 0
6,0
4,8
3,8 3,8
6,0
numberofprecisehits
value of the VYP
Average number of precise hits
0,00
5,00
10,00
15,00
20,00
25,00
1 2 3 4 5 6 7 8 9 10
seconds
attempt number
0pD
1pD
3 pD
5 pD
0 pD2
VII. CSKO 20. 10. 2016
94
Graph 5: Dependence of the average time duration of steps on the VYP
expressed in percentage
Summary
Intermediate results show that the hypothesis H1 and H2 are could be confirmed. In
contrast hypothesis H3 seems to be inconclusive. These results are preliminary and will
subsequently be supported by the analysis of a larger sample examined in order to increase
the statistical value of the measurement. Measurement was conducted with the aim of finding
short term adaptation to the VYP and it is probable that in the long-term adaptation the results
would differ. The topic of tolerance to the VYP of their wearer is wide. It offers the potential
for further exploration of the body and head posture, or the ability to keep the balance of its
wearer.
Resources
[1] Meslin D. Progressive lenses, Listy očních optiků: Essilor academy Europe, Paris, 2006,
[vid. 27-6-2016] ISBN 979-10-90678-07-1, [Online], Dostupné z:
http://www.zkcoo.cz/files/Cahier-Progressive%20Lenses-CZ.pdf
[2] Meister, D. Understanding Prism-Thinning, Lens Talk, [Online], 1998, [vid. 2-6-2016], Vol.
26, No. 35, Dostupné z: http://www.dicoptic.izispot.com/Files/thinpsm.pdf
[3] Hanlin, P.Prism thinning and progressive addition lenses, 20/20, magazine [Online], 2008,
[vid. 12-3-2016] Dostupné z: http://www.2020mag.com/
[4] Sheedy, J. E., Parsons, S. D. Vertical yoked prism-patient acceptance and postural
adjustment, Ophthalmic & Physiological Optics: The Journal Of The British College Of
Ophthalmic Opticians (Optometrists) 1987, MEDLINE Complete [Online], [vid. 26-1-2016]
255–257, Dostupné z: http://eds.a.ebscohost.com.ezproxy.muni.cz/
100,0
104,1
105,3 105,7
100,0
102,2 102,5
104,1
98,0
100,0
102,0
104,0
106,0
0 1 2 3 4 5
Averagetimeofonestep(%)
Value of the VYP
Standardized average time duration of steps
relavtive to attempt with 0 pD (%)
dolů nahoru
VII. CSKO 20. 10. 2016
95
Barevné folie a dyslexie
Autor: Bc. Zuzana Odvárková
Školitel: Mgr. Petr Veselý, DiS., Ph.D.
Anotace
Studie se zabývala použitím barevných průhledných folií jako kompenzační pomůcky pro
žáky s dyslexií. Do studie bylo zahrnuto 31 dyslektických žáků s průměrným věkem 11 let a 31
nedyslektických žáků s průměrným věkem 10 let (jako kontrolní skupina). Příznaky dyslexie
nejvýrazněji snižoval zelený odstín folie, naopak jako nejméně vhodný se ukazoval žlutý odstín
folie. Zrychlení čtení s použitím barevné folie nastalo téměř u 70 % dyslektických žáků.
Průměrné zlepšení u dyslektické skupiny bylo o 7,3 %, kdežto u nedyslektické skupiny dosáhlo
zlepšení v průměru 4,2 %, což představuje rozdíl 3,1 %.
Úvod a cíle
Nároky na čtení se v dnešním světě stále zvyšují. Avšak někteří lidé se potýkají s čtecími
potížemi již od dětství, protože trpí specifickou poruchou učení, dyslexií. Dyslexie je komplexní
porucha čtení, která se projevuje několika způsoby. Jedinci popisují skoky písmen a celých slov
na řádcích, nepříjemné odlesky a zamlžování textu, občasné zdvojení písmen apod. (Pipeková
2010) Problémy se čtením je potřeba zachytit co nejdříve a začít je kompenzovat specifickými
pomůckami, aby jedince omezovaly co nejméně. Specifickými poruchami učení se zabývají
psychologové, speciální pedagogové a v dnešní době i oftalmologové a optometristé.
(Scheiman 2004) Dyslexii řadíme mezi komplexní poruchy ovlivňované nervovými,
senzorickými a psychickými příčinami, avšak konkrétní důvody jejího vzniku nebyly zatím
odhaleny. (Bater 2011) K optickým příčinám bývá zařazena porucha v magnocelulárním
systému v thalamu, části mezimozku (diencephalon). Významná úloha je také přikládána
očním pohybům, především sakádám, které hrají při čtení důležitou úlohu. (Pokorná 2010)
Mezi možnosti optické kompenzace dyslexie patří předkládání barevné folie před čtený
text, barevné filtry v brýlových obroučkách nebo také barevné kontaktní čočky. Uvedené
barevné pomůcky upravují vzájemný kontrast textu a pozadí, mění chod paprsku
přicházejícího do oka. (Russnáková 2014)
Soubor a metodika
Výzkum probíhal celkem na třech základních školách. Vyšetřila jsem 31 dyslektických
dětí ve věku od 9 do 15 let ze ZŠ Svážná Brno, Starý Lískovec a ze ZŠ Košinova 22 Brno, Královo
pole. Měření tzv. kontrolní skupiny, tj. nedyslektických žáků, bylo realizováno na ZŠ Riegrova
4 Svitavy. Kontrolní skupina čítala také 31 žáků, a to ve věku od 9 do 12 let. Průměrný věk
v dyslektické skupině byl přibližně 11 let a průměrný věk nedyslektické skupiny se pohyboval
kolem 10 let.
Jako základní měřící vybavení jsem používala sadu barevných folií Standard Overlay
Testing Set z Velké Británie, který obsahuje dvě sady 12 odstínů barevných folií velikosti A5,
návod na použití, testovací arch a ukázku subjektivního testu. Pro samotné měření jsem
VII. CSKO 20. 10. 2016
96
využívala pouze 4 základní odstíny sady (žlutou, růžovou, modrou a zelenou). Se všemi odstíny
sady jsem nepracovala především pro zkrácení doby měření, aby děti byly schopné se
soustředit po celý jeho průběh, a také z důvodu jednoduššího výběru a určení konkrétního
odstínu.
Obrázek 8: Standard Overlay Testing Set
V počáteční fázi výzkumu jsem rozdala dětem informované souhlasy, kde jsem rodičům
nejen popisovala smysl a průběh studie, ale také jsem sdělovala možnosti dalšího využití pro
jejich děti. Další fázi představovalo samotné měření žáků, jejichž rodiče se zařazením do
výzkumu souhlasili. Výzkum probíhal v budovách jednotlivých škol ve volných třídách, a to
většinou v době po vyučování.
Měření s jedním žákem trvalo 10 až 15 minut. Zahrnovalo zjištění identifikačních údajů
(jméno a příjmení, datum narození a školu), datum měření, orientační určení zrakové ostrosti
pro případné vyloučení nekorigované refrakční vady jako příčiny dyslexie. Do studie byli
zahrnuti žáci se zrakovou ostrostí 0,9 a lepší s používanou korekcí. Při zjištění zhoršené zrakové
ostrosti žák nebyl do výzkumné skupiny zařazen a doporučila jsem mu návštěvu očního lékaře.
Po zaznamenání vstupních informací jsem zjišťovala subjektivní příznaky dyslexie, tj. zda je žáci
pociťuje a uvědomuje si je. Mezi hlavní dotazované příznaky dyslexie patřily skoky/vlnění
písmen a řádků,mlžení textu, odlesky, zdvojení a slévánítextu do jednoho. Po té jsem navázala
výběrem vhodného barevného odstínu používané folie, se kterým budou žáci číst nejrychleji a
budou nejméně pociťovat typické dyslektické příznaky. V rozřazovacím testu byli žáci vyzváni
ke čtení deseti různých slabik, a to co nejrychleji a správně, postupně se všemi čtyřmi
barevnými odstíny a s jednou čirou, kontrolní folií. Tato metoda výběru barevného odstínu
folie byla porovnána a doplňována subjektivním testem, kdy si žák sám vybíral nejpříjemnější,
nejpohodlnější čtení s pomocí folií. Nakonec jsme pracovali s odstínem vybraným
v rozřazovacím testu. Po výběru vhodného odstínu folie začalo hlavní měření rychlosti a
správnostičtení s barevnou folií ve srovnání s kontrolní folií. Žáci četli po dobu 30 vteřin určený
text s čirou folií, poté s vybranou barevnou folií, opět 30 vteřin, přičemž tento proces se
opakoval ještě jednou, aby se mohla vyhodnotit průměrná hodnota rychlosti čtení. Text byl
složen ze čtyř nebo pěti písmenných slov v základním tvaru, obsahoval podstatná jména,
přídavná jména a slovesa a byl tištěný hůlkovým písmem Arial. Na závěr měření jsem
VII. CSKO 20. 10. 2016
97
zaznamenala subjektivní pohled žáka, s jakou folií mu čtení bylo příjemnější, zda s barevnou
nebo čirou.
Výsledky
Výsledky měření jsem zapisovala do vlastních záznamových archů, které jsem následně
přenesla do grafické podoby. Nedyslektické děti přečetli v průměru 41,52 slov za 30 sekund,
zatímco dyslektické děti přečetli za uvedenou dobu pouze 30,57 slov. To potvrzuje očekávání,
že nedyslektické děti čtou rychleji než dyslektické. Zlepšení v rychlosti čtení u dyslektických
žáků však dosahovalo v průměru 7,3 %, což představuje statisticky významný rozdíl (Wilcoxon
test, p=0,005). Také zlepšení nedyslektické skupiny, které činilo 4,2 %, lze hodnotit jako
statisticky významné zlepšení (Wilcoxon test, p=0006). Avšak při porovnávání přírůstku čtení
s barevnou folií mezi dyslektickou a nedyslektickou skupinou nebyl zaznamenán statisticky
významný rozdíl (p=0,33) s výsledkem 53 slov pro dyslektickou skupinu a 51 slov pro
nedyslektickou skupinu. Téměř 70 % dyslektických dětí vykazovalo zlepšení v rychlosti čtení
(celkem 22 žáků).
Graf 1: Zlepšení čtení s barevnými foliemi u dyslektických dětí
Graf 2: Zlepšení čtení s barevnými foliemi u nedyslektických dětí.
4,2 %
VII. CSKO 20. 10. 2016
98
Počet vybraných barevných odstínů používaných folií v obou skupinách nevykazoval
velké rozdíly. Nejčastěji vybíranou barvu prostřednictvím rozřazovacího testu představovala
zelená, která byla v obou skupinách použita u dvanácti žáků. Nejméně byl naopak použit žlutý
odstín barevné folie, kterou využili čtyři dyslektičtí žáci a jeden nedyslektický žák. Výběr
barevných folií je zaznamenán v Tabulce 1. V chí-kvadrát testu byla prokázána rozdílnost v
přiřazování barevných filtrů mezi dyslektickou a nedyslektickou skupinou (p=0,02).
Odstín barvy Dyslektická skupina Nedyslektická skupina
Zelená 12 12
Modrá 9 11
Růžová 6 7
Žlutá 4 1
Tabulka 1: Rozložení výběru barevných odstínů používaných folií.
Diskuze
Jeannette J. Jansky v roce 1958 jako první popsala případ, kdy jedinec nedokázal
rozeznat tištěná slova na bílém papíře, ale byl schopen je přečíst na žlutém papíře. Na ní
později navazovali další autoři, například Bruce J. W. Evans se svou studií z roku 1999, kdy
zaznamenal zlepšení u 80 % žáků při používání barevných folií ve školách. (Uccula et al. 2014).
Jak uvádím výše, sama jsem v průběhu svého výzkumu zaznamenala zlepšení u 70 %
dyslektických žáků.
Určitou podobnost výsledných hodnot lze také sledovat v případě studie Joelle
Bouldoukian a spol. z roku 2002, ve které autoři zaznamenali zlepšení v rychlosti čtení
s barevnou folií minimálně o 5 %. Naopak jedinci, kteří si vybrali kontrolní folii (placebo),
zaznamenali zlepšení pouze o 1,7 %. (Bouldoukian et al. 2002).
Ve studii z roku 2011 od Lindsay Bater se uvádí, že pro praktickou aplikaci barevných folií
je nutné dosáhnout při čtení alespoň zlepšení o 5 %. V opozici s naším výzkumem v této studii
vyšla růžová barva jako nejvíce zlepšující plynulost čtení. (Bater 2011)
Arnold J. Wilkins ve své studii z roku 2011 píše, že ke zlepšení při čtení o 5 % dochází u
1/3 jedinců, zlepšení o 10 % už pouze u 1/10 jedinců a zlepšení o 25 % pouze u 1/20 jedinců.
Na druhou stranu udává, že alespoň nějaké zlepšení bylo zaznamenáno u více než poloviny
jedinců. (Uccula et al. 2014)
Závěr
Tato studie dokazuje pozitivní vliv používání barevných folií při čtení. Zvyšují rychlost
čtení jak u dyslektických žáků, tak u nedyslektických žáků. Konkrétně má používání barevných
folií za následek zlepšení rychlosti čtení o 7,3 % u dyslektických žáků a 4,2 % v případě
nedyslektických žáků. Výsledky mého výzkumu jsou také srovnatelné se závěry proběhlých
studií v zahraničí.
VII. CSKO 20. 10. 2016
99
Literatura
Pipeková, J. et al. Kapitoly ze speciální pedagogiky, 3. ed. Paido, Brno. 2010. ISBN
9788073151980.
Pokorná, V. Vývojové poruchy učení v dětství a dospělosti, 1. ed. Portál, Praha. 2010. ISBN
9788073677732.
Bater, L. Visual factors in specific learning difficulties. Optometry Today no. 12/2011, vol. 51,
pp. 44–48.
Bouldoukian, J. et al. Randomised controlled trial of the effect of coloured overlays on the rate
of the reading of people with specific learning difficulties. Ophthalmic Physiological Optic,
2002, no. 1, vol. 22, pp. 55–60.
Russnáková, L. Terapeutické účinky barevných filtrů. Česká oční optika, Praha: Společenstvo
českých optiků a optometristů č. 4/2014, roč. 55, s. 12–16. ISSN 1211-233X.
Scheiman, M. Colored Lenses to Improve Reading Comfort and Performance: Are Underlying
Vision Problems being Missed? Journal of Optometric Vision Development no. 1/2004, vol. 35,
pp. 37–41.
Uccula, A. et al. Colors, colored overlays, and reading skills. Frontiers in Psychology no. 7/2014,
vol. 5.
CERIUM VISUL TECHNOLOGY. Overlay testing set © 2016 [online]. [cit. 2016-02-28]. Dostupné
z: http://ceriumvistechproducts.com/shop/overlay-testing-set/
VII. CSKO 20. 10. 2016
100
Colour overlays and dyslexia
Author: Bc. Zuzana Odvárková
Supervizor: Mgr. Petr Veselý, DiS., Ph.D.
Annotation
Study deals of using colour transparent overlays as compensatory aid for dyslectic
children. To the study 31 dyslectic children of eleven years old were put and 31 non-dyslectic
children of eleven years old as control group. A green tint of overlay decreased symptoms of
dyslexia the most. On the contrary a yellow tint was used at least. Acceleration of reading with
colour overlays occurred in almost 70 % of dyslectic children. Overage improvement with
colour overlays was in the case of dyslectic children 7.3 % whereas improvement of nondyslectic
group was 4.2 %. Differences of improvement between both groups are 3.1 %.
Introduction
Demands on reading increase permanently in today's world. However some people are
struggling with reading difficulties since childhood because they suffer from specific learning
disorders called dyslexia. Dyslexia is complex disorders of reading which prove in several ways.
Individuals describe jumping of letters and whole words in the line, uncomfortable glare, and
fogging of the text, occasional double vision of letters etc. (Pipeková 2010) Reading problems
are needed to detect as soon as possible and begin to compensate it by specific tools for least
individual limiting. Psychologists, special education teachers, and nowadays even
ophthalmologists and optometrists deal with specific learning disorders. (Scheiman 2004)
Dyslexia belongs among complex disorders affected by neural, sensorial and psychological
causes. However the specific reasons for its emergence have not been revealed yet. (Bater
2011) The optical causes is included disorders in the magnocellular system in thalamus, part
of diencephalon. A significant role is given to eye movements, mainly saccades that play an
important role in reading. (Pokorná 2010)
Among the possibilities for optical compensation of dyslexia are included the coloured
overlays in front of the text, colour filters in the frames or colour contact lenses. Mentioned
colour tools adjust contrast of the text and the background, they change trajectory of the ray
coming to the eye. (Russnáková 2014)
Subject and Methods
Research was conducted at three elementary schools. I measured 31 dyslectic children
from 9 till 15 years old from ZŠ Svážná Brno, Starý Lískovec and from ZŠ Košinova 22 Brno,
Královo pole. Measurement of control group, nondyslectic children was realized at ZŠ Riegrova
4 Svitavy. Control group contained 31 children from 9 till 12 years old. Average age is 11 year
old at dyslectic group and 10 year old at non-dyslectic group.
I used set of colour overlays called Standard Overlay Testing Set from Great Britain. The
set contains 2 times 12 tints of colour overlays A5, manual, test sheet and demonstration
subjective test. For measuring I used only four baric tints (yellow, rose, aqua blue, apple
VII. CSKO 20. 10. 2016
101
green). I used only these tints to shorten the measuring time and children could be able to
focus throughout whole process, and also for more easily chosen of the tint.
Picture 9: Standard Overlay Testing Set.
At the beginning of research I distributed informed consent among children’s parents.
There were described sense and process of study in the letter. I offer them some opportunity
to use colour overlays in future of themselves. Other parts included measuring of children who
parents agree to add to research. Research took place in the building of schools in the free
classes, usually at the end of lessons.
Measurement lasted 10 to 15 minutes with one child. Fist part included finding the
identification data (name and surname, date of birth and school) measuring date,
approximate determination of visual acuity for elimination of uncorrected refractive error
which could be a cause of dyslexia. The study included child with visual acuity 0.9 and better
with their using correction. When I found decrease visual acuity the child was not added to
the study and I referred him to the ophthalmologist. After recording the entrance information
I investigated the subjective symptoms of dyslexia i.e. whether children feels and realizes it.
The main symptoms of dyslexia were interviewed jumps / waves of letters and lines, blurry
image, reflections, double vision and flowing together. Then we continued by selecting of
appropriate tint of overlays which the students will read quickly with. They will not feel the
typical dyslexic symptoms so much. Children were asked to read ten different syllables in the
dividing test the quickest and right. Children read it step by step with four colour overlays and
one control transparent overlay. This method was compared and supplemented by a
subjective test. Child chose colour tint himself which was the most comfortable. Finally, we
worked with the tint selected in the dividing test. After selection of tint the principal
measurement began which included the speed and accuracy of reading with colour overlays
to compare with control overlay. Children read for 30 seconds specified text with transparent
overlay, then with selected colour overlay again 30 second. This process was repeated once
more to be able to assess the value of the average reading speed. The text was composed of
four or five-letter words in their basic form, contained nouns, adjectives and verbs. It was
VII. CSKO 20. 10. 2016
102
printed in capital letters Arial. At the end of measurement I noticed a subjective view of child,
his reading was more comfortable with colour or control overlay.
Results
The results of measuring I have noticed in my own registration sheets afterwards
transferred in the graphic form. Non-dyslectic children read 41.52 words on the average in 30
seconds, while dyslectic children only 30.57 words in the same time. It confirms the
expectation that non-dyslectic children read faster than dyslectic children. Improvement in
reading speed dyslexic pupils averaged 7.3% which represents a statistically significant
difference (Wilcoxon test, p = 0.005). Also, improvements non-dyslectic groups can be
evaluated as statistically significant improvement (Wilcoxon test, p = 0,006) which amounted
to 4.2%. However difference between dyslexic and non-dyslectic group was not statistically
significant difference (p = 0.33), with the result of 53 words for dyslexic group and 51 words
for non-dyslectic group. Almost 70 % of dyslectic children achieve the improvement in the
speed of reading with using of colour overlays (22 children).
Graph 1: Improvement reading with coloured overlays of dyslexic children.
7.3 %
4,2 %
VII. CSKO 20. 10. 2016
103
Graph 2: Improvement reading with coloured overlays of non-dyslectic
children
The number of chosen colour tints of used overlays in the both groups show only quite
small differences. The most frequent one was the green tint that was chosen through the
dividing test and then used by 12 pupils in the both groups. The less frequent one was the
yellow tint that was used by 4 dyslectic children and by 1 non-dyslectic children. The choice of
colour overlays is shown in the Table 1. The chi-square test demonstrated difference in the
assignment of colour filters between dyslexic and non-dyslectic group (p = 0.02).
Tint Dyslectic group Non-dyslectic group
Apple green 12 12
Aqua blue 9 11
Rose 6 7
Yellow 4 1
Table 1: Layout selection of colours used overlays.
Discussion
Jeannette J. Jansky in 1958 as the first one describes the example, when the individual
wasn’t able to distinguish printed words on the white paper, but was able to read them on the
yellow paper. J. J. Jansky was followed by others authors, for example Bruce J. Ewans with his
study from 1999, when he detected an improvement of 80 % of pupils thanks to using colour
overlays in schools. (Uccula et al. 2014) Also in my research I have registered the improvement
of 70 % of dyslectic pupils.
Similar resulting values we can also find in the study of Joelle Bouldoukian et al. from
200. In this study was monitored the improvement in the speed of the reading with colour
overlays of 5 %. On the other hand in the case of individuals, that chose the control overlay
(placebo), was detecting only 1.7 % improvement. (Bouldoukian et al. 2002)
In the study from 2011 by Lindsay Bater is mentioned that for practical application of
colour overlays is necessary to achieve the 5 % improvement at least. In this study was
indicated, in the opposition to my research, that the best for fluency of reading is the pink
colour (Bater 2011).
Arnold J. Wilkins in his study from 2011 writes that the 5 % improvement occurs in 1/3
of individuals, the 10 % improvement occurs in 1/10 of individuals and the 25 % improvement
only in the case of 1/20 of individuals. On the other hand he mentions that some minimum
improvement was detected at least in more than half of individuals. (Uccula et al. 2014)
Conclusion
This study proves the positive influence on using of colour overlays by reading. They
increase the speed of reading of both dyslectic and non-dyslectic children. Specifically, using
of colour overlays results in the 7.3 % improvement of reading speed in the case of dyslectic
children and 4.2 % improvement in the case of non-dyslectic children. The results of my
research are also comparable with conclusions of studies from abroad.
VII. CSKO 20. 10. 2016
104
Resources
Pipeková, J. et al. Kapitoly ze speciální pedagogiky, 3. ed. Paido, Brno. 2010. ISBN
9788073151980.
Pokorná, V. Vývojové poruchy učení v dětství a dospělosti, 1. ed. Portál, Praha. 2010. ISBN
9788073677732.
Bater, L. Visual factors in specific learning difficulties. Optometry Today no. 12/2011, vol. 51,
pp. 44–48.
Bouldoukian, J. et al. Randomised controlled trial of the effect of coloured overlays on the rate
of the reading of people with specific learning difficulties. Ophthalmic Physiological Optic,
2002, no. 1, vol. 22, pp. 55–60.
Russnáková, L. Terapeutické účinky barevných filtrů. Česká oční optika, Praha: Společenstvo
českých optiků a optometristů č. 4/2014, roč. 55, s. 12–16. ISSN 1211-233X.
Scheiman, M. Colored Lenses to Improve Reading Comfort and Performance: Are Underlying
Vision Problems being Missed? Journal of Optometric Vision Development no. 1/2004, vol. 35,
pp. 37–41.
Uccula, A. et al. Colors, colored overlays, and reading skills. Frontiers in Psychology no. 7/2014,
vol. 5.
CERIUM VISUL TECHNOLOGY. Overlay testing set © 2016 [online]. [cit. 2016-02-28]. Dostupné
z: http://ceriumvistechproducts.com/shop/overlay-testing-set/
VII. CSKO 20. 10. 2016
105
Srovnání metod měření a validita hodnot potřebných pro
přesný zábrus brýlových čoček
Autor: Mgr. Lucie Patočková
Školitel: Mgr. Pavel Beneš, Ph.D.
Cílem práce je uvedení do problematiky přesného zábrusu brýlových čoček, vysvětlení
základních principů oko - brýlový střed, uvedení základních metod měření vstupních údajů
zábrusu a popsání důsledků nepřesně zhotovené brýlové korekce. Výzkum je zaměřený na
četnost přesáhnutí hodnot decentrace optických středů brýlových čoček ku středům zornic
nad hraniční hodnotu, u které by brýlová korekce nebyla u jedinců snášena. U zabroušených
tórických čoček je zkoumáno, zdali nedošlo ke stočení osy cylindrické složky nad tolerovanou
hranici. Práce je zakončena porovnáním vstupních hodnot měření, a to srovnáním hodnot
pupilární distance, naměřené třemi metodami - přímou metodou, digitálním PDmetrem a
softwarem Omega smart mirror.
Použitými metodami byly:
Metoda značení na fólie – měření na nekonečno
Při této metodě fixuje vyšetřovaný předmět v minimální vzdálenosti 6 metrů. Poloha
středů zornic je zakreslena na fólie v brýlové obroučce, nebo je pupilární distance změřena PD
měřítkem.
Měřítko má milimetrovou stupnici a je přizpůsobené svým výřezem pro nosní kořen a
pro oči potřebám měření.
Metoda měření s digitálním PDmetrem NIDEK PM-600
Pupilární vzdálenost byla změřena přiložením PDmetru na kořen nosu a pomocí
posuvných jezdců přístroje byly nalezeny středy zornic. Přístroj automaticky vypočítává
pupilární vzdálenost.
PDmetr s rozsahem 47 až 83 mm s odkrokováním po 0,5 mm. Součástí přístroje je otočný
šroub, pomocí kterého lze nastavit pohledovou vzdálenost na 30 cm, 35 cm, 40 cm, 50 cm, 65
cm, 1 m, 2 m a do nekonečna.
Metoda měření se softwarem Oculus smart mirror
Software spolu s násadou s referenčními značkami, která se umisťuje na brýlovou
obrubu, změří pupilární distanci s přesností na milimetry. Také měří vzdálenost mezi dolním
okrajem brýlové čočky a středem zornice. Software měří PD jak do dálky, tak i do blízka.
Metoda měření s fokometrem NIDEK LM-600PD
Na fokometru jsou zjišťovány polohy optických středů brýlových čoček a také provádí
kontrolu výsledného zábrusu. Pomocí fokometrů lze také zjišťovat vrcholová lámavost brýlové
čočky.
VII. CSKO 20. 10. 2016
106
Fokometr je vybavený Hartmannovým senzorem se 108 měřícími body a s režimem pro
automatické rozpoznávání typů čoček (monofokální, multifokální). Součástí je 4.7" barevný
LCD displej. LM-600PD má vestavěnou tiskárnu, je vybavený zařízením na měření PD a
automatické rozpoznání měřené očnice (P/L). Fokometr obsahuje režim pro měření
propustnosti UV.
Výzkumu se účastnilo 192 osob, z toho 98 můžu a 94 žen ve věku od 3 do 87 let.
Hypotézy a výsledky:
Decentrace nepřekročí povolenou toleranci (mm) v 95 % případů.
Doposud nebyla provedena studie, která by byla totožná s mým výzkumem, a proto je
stanoven limit k posouzení na 5 % jako možné odchylky. Porovnány jsou hodnoty decentrace
u přímé metody (vstupní hodnota) – měření pravítkem po označení na fokometru (výstupní
hodnota), přímé metody – software fokometru, digitální PDmetr – pravítko, digitální PDmetr
– fokometr, software Omega smart mirror – pravítko, software Omega smart mirror –
fokometr, které jsou vztažené na Zásady posuzování brýlí jako korekční pomůcky vydané
Společenstvem českých optiků a optometristů.
Vrcholová lámavost včetně [D] horizontálně vertikálně
1,0 5 2,5
2,0 2,5 1,25
3,0 1,5 1
4,0 1,25 1
5,0 1 1
10,0 1 1
20,0 1 1
50,0 1 1
Tab. 1: Povolená tolerance mm (binokulárně)
Záměrem hypotézy je ověření, v jaké míře překročí po provedeném zábrusu decentrace
optického středu ve vztahu ke středu rohovky povolenou hranici. Data decentrací jsou
vztažena k vrcholové lámavosti čočky a porovnána s kritériem v tabulce 1. Z výsledků vyplývá,
že decentrace nad zvolenou hranicí je 9 %, a tudíž je hypotéza nepotvrzena.
Graf 1: Grafické znázornění hodnot, které překročily zvolenou hranici.
Osa x – jednotlivé metody, osa y – četnost.
VII. CSKO 20. 10. 2016
107
Stočení osy u tórických čoček nepřekročí osovou toleranci dle SČOO v 95 %
případů.
U stočení osy tórických čoček je opět stanovena tolerance požadované polohy na 95 %.
Vstupní hodnotou výzkumu je lékařský předpis či údaje naměřené optometristou a výstupní
hodnotou naměřená osa po zábrusu. Kritéria jsou stanovena Zásadami posuzování brýlí jako
korekční pomůcky vydané Společenstvem českých optiků a optometristů
Vstupní – výstupní hodnoty
měř-prav PD změřené PD měřítkem – PD změřené měřítkem z označených brýlových
středů
měř-foko PD změřené PD měřítkem – PD změřené fokometrem
dig-prav PD změřené digitálním PDmetrem – PD změřené měřítkem z označených
brýlových středů
dig-foko PD změřené digitálním PDmetrem – PD změřené fokometrem
tab-prav PD změřené tabletem s Omega smart mirror – PD změřené měřítkem
z označených brýlových středů
tab-foko PD změřené tabletem s Omega smart mirror – PD změřené fokometrem
VP měř-prav Výška OP – změřená PD měřítkem – zkontrolovaná měřítkem
VP tab-prav Výška OP – změřená tabletem s Omega smart mirror – zkontrolovaná měřítkem
VL měř-prav Výška OL – změřená PD měřítkem – zkontrolovaná měřítkem
VL tab-prav Výška OL – změřená tabletem s Omega smart mirror – zkontrolovaná měřítkem
Korekční cylindr v [D] Osová tolerance [°]
≤ 0,75 ± 5
< 1,00 ≥ 1,5 ± 3
≤ 1,75 - 6 ± 2
Tab. 2: Závislost korekčního cylindru a tolerance ve stupních.
Cílem hypotézy je zjištění, jak centrace a zábrus tórických čoček ovlivňují stočení osy
cylindru. Data jsou vztažená na vrcholovou lámavost brýlové čočky a jsou uvedená v tabulce
číslo 3. Tolerovaná hranice je překročená 2x. Jednou o jeden stupeň, podruhé o dva stupně.
Požadovaného zábrusu je docíleno v 99 % případů, a tedy je hypotéza potvrzená.
Korekční cylindr [D] Celkem V tolerančním rozmezí Nad toleranční hranicí
≤ 0,75 134 134 0
< 1,00 ≥ 1,5 40 40 0
≤ 1,75 - 6 24 22 2
Tab. 3: Data spadající do tolerovaného rozmezí a nad tolerovanou hranici ve
vztahu k vrcholovým lámavostem brýlových čoček.
Naměřené PD (binokulárně) pomocí 3 metod (PD měřítko, digitální PDmetr a
software) se od sebe nebudou v průměru lišit o více jak 1,5 mm.
U srovnávání metod měření jsou porovnány hodnoty naměřené přímou metodou,
PDmetrem a softwarem Omega smart mirror. Porovnány jsou průměry naměřených hodnot s
kritériem 1,5 mm.
VII. CSKO 20. 10. 2016
108
Hypotéza porovnává průměry hodnot binokulárního PD naměřených 3 metodami
s cílem zjistit, jak se od sebe jednotlivé metody liší. Kritérium je stanoveno na rozdíl 1,5 mm.
Porovnáním metod měřeníPD měřítkem a digitálním PDmetrem je rozdíl průměrů 0,1937 mm,
u metod PD měřítka a softwaru Omega smart mirror je naměřen rozdíl 0,4853 mm a rozdíl
0,2916 mm je naměřen u rozdílu průměru digitálního PDmetru a softwaru. Hypotéza je tedy
potvrzena.
Způsob měření Rozdíl [mm] Potvrzení/nepotvrzení hypotézy
PD měřítko – PDmetr 0,1937 hypotéza potvrzena
PD měřítko – Software 0,4853 hypotéza potvrzena
PDmetr-software 0,2916 hypotéza potvrzena
Tab. 4: Porovnání metod měření.
Diskuze
K první hypotéze nejsou doposud provedené adekvátní výzkumy, jež jsou porovnatelné
s výzkumem této práce. Z toho důvody jsou data vztažená na doporučené zásady posuzování
brýlové korekce, které vydalo SČOO v roce 2006. Data byla vztažena na jednotlivé rozsahy
vrcholových lámavostí a z chybovosti v jednotlivých částech byla vypočítána decentrace v
procentech nad povolenou hranicí. Výsledky nepotvrdily hypotézu č. 1. Jelikož byl zábrus
čoček prováděn na 2 zábrusových automatech, je vhodným námětem na další výzkum užití
pouze jednoho automatu.
Druhá hypotéza rovněž neměla srovnání s doposud provedenými výzkumy, a proto opět
vycházela z doporučených zásad od SČOO. Hodnocení dat bylo vztažené k jednotlivému
rozsahu korekčního cylindru. Data potvrdila hypotézu č. 2.
Ani třetí hypotéza nemá doposud srovnatelný výzkum. Kritéria pro porovnání byla
stanovena na 1,5 mm rozdílu mezi jednotlivými metodami měření. Dohromady byly
porovnávány jak hodnoty PD do dálky, tak i do blízka. Průměry PD u jednotlivých metod byly
srovnány a z výsledků vyplynulo potvrzení hypotézy č. 3.
Závěr
V současné době má optometrista, potažmo oční optik, možnost využití moderních
technologií, které je vhodné kombinovat s tradičními metodami. Jedná se především o použití
minimálně dvou technik při zjišťování pupilární distance, a to např. měření s digitálním
PDmetrem v kombinaci s přímou metodu nebo s využitím softwaru v tabletu či centrovací věži.
Výhodou užití minimálně dvou metod je nejen zaručena zvýšená přesnost, ale také se v
zákazníkovi vzbuzuje důvěra, že je o jeho zrak kvalitně postaráno.
Poděkování
Děkuji vedoucímu diplomové práce, panu Mgr. Pavlu Benešovi, Ph.D., za rady ke
zpracování výzkumné části, za připomínky k části teoretické a za vstřícnost při konzultacích.
Poděkování patří též Oční opice Hana Stárková, kde mi bylo umožněno získat veškerá
data potřebná pro výzkum.
VII. CSKO 20. 10. 2016
109
Zdroje
Najman, L. Možné chyby při zhotovení korekčních brýlí. Česká oční optika, Praha: Česká
společnost očních optiků a optomet, 2012, No 3, p. 24-25. ISSN 1211-233X.
NIDEK, Co., LTD. LM-600PD/600P/600. [Online]. 2009, Japonsko. [cit. 2016-04-10]. Dostupné
z: http://www.oculus.sk/lens/lm600.pdf
NIDEK, Co., LTD. PM-600. [Online]. 2007, Japonsko. [cit. 2016-04-10]. Dostupné z:
https://www.genop.co.za/media/pdf/Nidek/Nidek%20Files/Nidek%20PM-600.pdf
SČOO, představenstvo. Zásady posuzování brýlí jako korekční pomůcky. Informační brožura.
Praha 2006. [cit. 2016-03-21]
VII. CSKO 20. 10. 2016
110
Comparison of measurement methods and necessary
validity values for accurate lens grinding
Author: Mgr. Lucie Patočková
Supervisor: Mgr. Pavel Beneš, Ph.D.
The aim is to introduce the problems of accurate lens grinding, explanation of the basic
principles of the eye - glasses, explanation methods of measuring of input data and
consequences described inaccurately of glasses correction. Research is focused on the
frequency exceeding the values of decentralization optical centers of the lenses to the centers
of the pupil over the threshold at which the spectacle correction was not tolerated in
individuals. For toric lens is examined if there was no twist axis cylindrical component of the
tolerated threshold. The work is finished by comparing the input values of measurement,
comparing the values pupillary distance, measured by three methods - direct method, PD
meter and software Omega smart mirror.
The methods:
Measurements at infinity
In this method, the examinee fixates object at a minimum distance of 6 meters. Position
of the center of the pupil is drawn to the foil in the glasses. It has a millimeter scale.
Method for measuring by digital PDmeter NIDEK PM-600
Pupillary distance was measured by placing PDmeter on the nose and sliders devices
were placed in the centre of pupil. The device automatically calculates the pupillary distance.
PDmetr with a range of 47-83 mm with steps 0,5 mm. Part of the device is a rotary screw,
which allows you to set a visual distance of about 30 cm, 35 cm, 40 cm, 50 cm, 65 cm, 1 m, 2
m and to infinity.
Method for measuring software Oculus smart mirror
Software along with the stick with reference marks, which will be placed on the glasses,
pupillary distances measured with an accuracy of millimeters. Also measure the distance
between the bottom edge of the lens and the center of the pupil. The software measures the
PD for distant and near vision.
Method for measuring by the focometer NIDEK LM-600PD
The Focometer is determined position of the optical centers of lenses and also checks
the resulting accurate lens grinding. Using focometer can also detect peak brittleness lenses.
Focometer is equipped with a sensor 108 measuring points with the regime for
automatic recognition type lenses (monofocal, multifocal). It includes a 4.7 "color LCD display.
LM-600PD has a built-in printer is equipped with a device for measuring PD and
automatic recognition of the measured orbit (R / L). Focometer includes a mode for measuring
UV transmittance.
VII. CSKO 20. 10. 2016
111
The research included 192 people, 98 men and 94 women aged between 3-87 years.
Hypotheses and results:
Decentration exceed the allowed tolerance (mm) in 95% of cases.
There is no study, which would be the same with my research, and is therefore a limit
to assess the 5% deviation as possible. Compared to the value of decentralization by direct
methods - measuring after marking on focometer (output value), direct methods - software
focometer digital PDmetr - ruler, digital PDmetr - focometer, software Omega smart mirror ruler,
like Omega smart mirror - focometer, which are related to the assessment principles
spectacles as corrective aids issued by the Association of Czech Opticians and Optometrists.
Dioptre [D] Horizontal Vertical
1,0 5 2,5
2,0 2,5 1,25
3,0 1,5 1
4,0 1,25 1
5,0 1 1
10,0 1 1
20,0 1 1
50,0 1 1
Chart 1: Permissible tolerance mm (binocular).
The intent is to verify hypotheses, to what extent exceeds after conducting lens grinding
decentration of the optical center relative to the center of the cornea permitted limit. Data
decentration (Graph 1) are referenced to the peak refractive power lenses and compared with
the criteria in Chart 1. The results show that decentration above a selected threshold is 9%,
and therefore hypothesis unconfirmed.
Graph 1: Graphical representation of values that exceeded the permitted
limit. The x-axis - each method, the y axis - frequency.
Twisted axis for toric lenses exceed axial tolerance according the Association of
Czech Opticians and Optometrists in 95% of cases.
For toric lenses twist axis is again determined tolerances required position at 95%. Input
value of research is prescription or measured data optometrists and output value measured
VII. CSKO 20. 10. 2016
112
along the axis after lens grinding. The criteria are set out principles for the assessment of
spectacles as corrective aids issued by (ACOO).
Input - output values
měř-prav PD measured by PD ruler – PD checked by ruler
měř-foko PD measured by PD ruler – PD checked by focometer
dig-prav PD measured by digital PDmeter – PD checked by ruler
dig-foko PD measured by digital PDmeter – PD checked by focometer
tab-prav PD measured by software with Omega smart mirror – PD checked by ruler
tab-foko PD measured by software with Omega smart mirror – PD checked by focometer
VP měř-prav Height OR – measured by PD ruler – PD checked by ruler
VP tab-prav Height OR – measured by software with Omega smart mirror – PD checked by
ruler
VL měř-prav Height OL – measured by PD ruler – PD checked by ruler
VL tab-prav Height OL – measured by software with Omega smart mirror – PD checked by
ruler
Dioptre [D] Axis tolerance [°]
≤ 0,75 ± 5
< 1,00 ≥ 1,5 ± 3
≤ 1,75 - 6 ± 2
Chart 2: The dependence of the correction cylinder and tolerances in degrees.
The aim is to determine hypotheses as centration and grinding of toric lenses affect twist
axis of the cylinder. Data are based on peak refractive power lenses and are listed in Chart 3.
Tolerable limit is exceeded 2x. One by one degree, the second of two degrees. Desired lens
grinfing is achieved in 99% of cases, and hence the hypothesis is confirmed.
cylinder [D] number within the tolerance above the tolerance
≤ 0,75 134 134 0
< 1,00 ≥ 1,5 40 40 0
≤ 1,75 - 6 24 22 2
Chart 3: Data within the tolerable range and above the tolerated threshold
in relation to dioptres.
The measured PD (binocular) using 3 methods (PD ruler, digital PDmeter and
software) from one another will not vary in diameter by more than 1,5 mm.
In comparison measurement methods are compared to the values measured by the
direct method, PDmeter and spftware Omega smart mirror. Comparing the averages of the
measured values with a criterion of 1,5 mm.
Hypothesis compares the averages of the binocular PD measured by 3 methods to
determine how the one from the other methods vary (Chart 4). The criterion is set at a
difference of 1,5 mm. Comparing methods of measuring PD ruler and measure digital PDmeter
difference is 0,1937 mm, with PD ruler and software Omega smart mirror is measured
difference 0,4853 mm and 0,2916 mm difference is measured by the difference between
average digital PDmeter and software. The hypothesis is confirmed.
VII. CSKO 20. 10. 2016
113
methods of measurement difference [mm] Confirmation of the hypothesis
PD ruler – PDmeter 0,1937
PD ruler – Software 0,4853
PDmeter-software 0,2916
Chart 4: Comparison of measuring methods.
Discussion
The first hypothesis is not yet carried out adequate investigations, which are comparable
to the research of this work. For this reason, the data relative to the recommended principles
for assessment of glasses correction, which published ACOO in 2006. The data was based on
the individual ranges and senior fragility of error in various parts of decentralization was
calculated as a percentage of the allowable limit. The results confirmed the hypothesis 1. Since
grinding of lenses was carried out on two ground-glass machines, it is a good topic for further
research use only one controller.
The second hypothesis is also not compared with studies carried out and therefore,
again based on the principles recommended by ACOO. Evaluation of data was related to a
particular extent of the correction cylinder. The data confirmed the hypothesis no. 2.
Neither the third hypothesis is not yet comparable research. Criteria for comparison was
set at 1,5 mm a difference between measurement methods. Altogether they were compared
to PD into the distance and near vision. PD averages in individual methods were compared
and the results showed the hypothesis no. 3.
Conclusion
Currently optometrist, optician hence, the possibility of using modern technologies that
can be combined with traditional methods. This is primarily the use of at least two techniques
for detecting pupillary distance, eg. Digital measurement PDmeter in combination with the
direct method or using software in the tablet or centering tower. An advantage of using at
least two methods are not guarantees increased accuracy, but also in customer raises
confidence that his eyesight well cared for.
Thanks
Thank head of the thesis, Mr. Mgr. Pavel Beneš, Ph.D., for advice on handling the
research section for comments on the theoretical and helpfulness during consultations.
Thanks are also eye optician Hana Starkova, where I was able to get all the data
necessary for the research.
VII. CSKO 20. 10. 2016
114
Resources
Najman, L. Možné chyby při zhotovení korekčních brýlí. Česká oční optika, Praha: Česká
společnost očních optiků a optomet, 2012, No 3, p. 24-25. ISSN 1211-233X.
NIDEK, Co., LTD. LM-600PD/600P/600. [Online]. 2009, Japonsko. [cit. 2016-04-10]. Dostupné
z: http://www.oculus.sk/lens/lm600.pdf
NIDEK, Co., LTD. PM-600. [Online]. 2007, Japonsko. [cit. 2016-04-10]. Dostupné z:
https://www.genop.co.za/media/pdf/Nidek/Nidek%20Files/Nidek%20PM-600.pdf
SČOO, představenstvo. Zásady posuzování brýlí jako korekční pomůcky. Informační brožura.
Praha 2006. [cit. 2016-03-21]
VII. CSKO 20. 10. 2016
115
Irisregistrace
Autor: Bc. Hana Štolzová
Školitel: Mgr. Ondřej Vlasák
Irisregistrace je jednou z nejnovějších metod využívaných ke sledování očních pohybů
v refrakční chirurgii. V praxi může být aplikována k rozpoznávání limbu a pupily a v plné verzi
i k detekci horizontálních, vertikálních i torzních pohybů. Sledování volních i mimovolních
očních pohybů během operace je důležité kvůli správnému umístění laserové korekce, a tak i
přesnému oploštění rohovky.
Využití metody a komplikace
Optické stabilizační metody jsou nyní nejčastěji využívaným detekčním systémem
v refrakční chirurgii. Při jejich aplikaci však musí být řešeny komplikace spojené s pořizováním
snímků a jejich následnou analýzou.
Mezi základní aspekty komplikující optickou stabilizaci patří změna velikosti zornice,
která indukuje změnu polohy kontrastních oblastí na duhovce. Nejčastěji lze transpozici
zkoumaných zón zakomponovat do výpočtů a chybovost omezit. Dalším faktorem je možné
rozmazání obrázku pořizovaného při očním pohybu. S příchodem moderních technologií se
však zvýšila frekvence a přesnost snímání obrazu, k danému efektu tak téměř nedochází.
K dosažení potřebného výsledku měření je také nutné kompenzovat míru osvětlení a jeho
směr, odlesky na rohovce, nežádoucí stíny a změnu směru, ze kterého je objekt snímán.
Aby byl vliv těchto chyb omezen na minimum, je výhodné strukturu duhovky převést na
polární souřadnice.
Aplikace metody a průběh operace
Všechny tři sekce operace, diagnostika, vytváření ablačního plánu i samotná operace, by
měly sdílet stejný koordinační systém. Tento systém musí plnit dvě základní funkce. První je
přesné určení polohy oka, horizontální a vertikální umístění i axiální orientace. Druhá důležitá
úloha je opakovatelnost měření a následné analýzy. Irisregistrace je metoda, která splňuje
všechny výše zmíněné podmínky.
Pořízení snímku
Během předoperačních vyšetření je nejdříve pořízen obraz duhovky. Speciální program
určí vnější a vnitřní okraj duhovky, středy pupily a iris a hlavní body na duhovce, tady oblasti
s vysokým kontrastem. Problém může nastat u velmi světlých duhovek, kde není program
schopen nalézt záchytné body nebo okraj, a u duhovek s vrozenou vadou, jako je například
kolobóm duhovky, nebo naevus na limbu, který znemožňuje přečtení kulatého okraje
duhovky.
Snímek iris je pořízen v pozici vsedě, stejně jako předoperační diagnostická data,
a všechny informace jsou ihned spárovány. Operatér naplánuje potřebný zákrok a struktura
tohoto zákroku je opět přiřazena k prvnímu snímku duhovky. Třetím krokem při provádění
VII. CSKO 20. 10. 2016
116
laserové refrakční léčby je sejmutí obrázku duhovky v pozici vleže na operačním lůžku. Protože
při změně pozice dochází k rotaci oka, je pořízený obrázek spárován s předchozím, takto je
přiřazen plán zákroku k oku ve správném úhlu.
V průběhu operace jsou uložená obrazová data pravidelně, nebo dokonce nepřetržitě
porovnávána s reálným obrazem iris. Probíhá tedy v podstatě eye tracking, sledování očních
pohybů.
Analýza snímku
Při pořizování a rozboru duhovkové struktury rozlišujeme takzvaný referenční snímek,
zhotovený v průběhu předoperačních vyšetření,a snímky pořizované v průběhu operace. Data
získaná z těchto obrazů jsou porovnávaná s daty z referenčního snímku.
Referenční snímek je černobílý a je snímán CCD kamerou pomocí infračerveného světla.
Dochází k rozlišení téměř 260 odstínů šedi. Obrázek obsahuje pupilu a iris. U některých snímků
může být část duhovky překryta víčkem nebo řasami. Překryvy by však neměly být větší než
šířka duhovky.
Zachycení pacientovy duhovky a pupily může být provedeno již při wavefront analýze
oka. Snímek je poté podroben rozboru pomocí několika speciálních algoritmů.
Nejprve je detekován kruhový charakter limbu i okraje pupily a následně jsou vypočteny
oba jejich středy. Běžně jsou, pro zjednodušení, považována obě centra za identická, což by
v tomto případě mohlo činit potíže s určováním záchytných bodů na duhovce. Problém by
mohl vzniknout i v případě, že by některá z fází operace byla vztažena k jinému středu než
zbylé fáze.
Rozdíl mezi centrem duhovky a pupily a význam dilatace zornice
Vyvstává otázka, jaký je rozdíl mezi středem zorničky a centrem iris. Odpověď je
jednoduchá, okraj pupily je tvořen vnitřní hranicí duhovky a centrum je vypočteno vzhledem
k tomuto rozhraní, střed iris je však odvozen vzhledem k limbu. Obě centra jsou od sebe
vzdálená v jednotkách mikrometrů, ale relativní vzdálenost se může upravit se změnou míry
dilatace zorničky.
Změna velikosti zornice ovlivňuje relativní polohu jejího středu vůči středu duhovky. Při
rozdílné centraci diagnostických dat nebo plánu ablace a jejího provedení by mohlo docházet
k indukci nežádoucích aberací. Některé z metod optické stabilizace jsou již schopny tento jev
eliminovat na minimum, a to díky speciálním přepočtům nebo možnosti individuálního
předoperačního nastavení.
Segmentace duhovky
Pro jednoznačnou identifikaci stejného místa iris v obou snímcích, diagnostickém
referenčním snímku a předoperačním obrázku, je možné analyzovat iris jako celek, ale
nejvýhodnější je duhovku rozdělit do několika oddílů. Duhovka je většinou rozdělena
na 24 sektorů po 15°, což je nejvhodnější rozvržení vzhledem k maximálním fyziologicky
dosažitelným hodnotám úhlu pootočení oka. K rozdělování dochází hlavně kvůli lepší
VII. CSKO 20. 10. 2016
117
identifikaci kontrastních úseků. Po rozdělení vzniknou malé sekce, ve kterých je lépe
zaregistrovatelná shoda pootočených kontrastních oblastí.
Způsoby aplikace optické stabilizace
Prvním způsobem, jak může stabilizační metoda fungovat, je jednoduché zacílení
laserového paprsku na určitý bod a kontrola stálosti podkladu. V tomto případě je správnost
umístění zákroku zajištěna vypínáním laseru. Pokud je oko v nežádoucí pozici vůči operačnímu
přístrojia sledovacímu zařízení, působení laseru je ihned ukončeno. Při operacích intraokulární
čočky je toto sledování možné díky registraci limbu a cév v jeho blízkosti.
Druhým způsobem je průběžné posouvání přístroje s laserem dle pohybu iris tak, aby
došlo ke sjednocení uložených obrazových dat v laserovém systému a dat sledovaných
v reálném čase.
V praxi je možné obě metody kombinovat a kompenzovat tak pohyby oka efektivněji.
Výsledky odborných studií
Praktický význam metody spočívá v přesné centraci diagnostických dat, plánu zákroku,
správné adjustaci laseru a sledovacího zařízení vůči oku pacienta. Ze studií zkoumaných v dané
bakalářské práci vyplývá, že operace prováděné za účasti této metody jsou velmi úspěšné a
spolehlivost centrace je velmi vysoká. Významnější kladný dopad použití metody vzniká při
korekci astigmatismu vyšších hodnot.
Zdroje
Anderle, R. Comparison of visual acuity and higher-order aberrations after standard and
wavefront-guided myopic femtosecond LASIK. Ceska01 A Slovenska01 Oftalmologie: Casopis
Ceske01 Oftalmologicke01 Spolecnosti A Slovenske01 Oftalmologicke01 Spolecnosti [online].
2015, 71(1), 44-50 [cit. 2016-03-20]. ISSN 1211-9059.
Chernyak, D.A. From wavefront device to laser: an alignment method for complete
registration of the ablation to the cornea. Journal Of Refractive Surgery (Thorofare, N.J: 1995)
[online]. 2005, 21(5), 463-8 [cit. 2016-03-20]. ISSN 1081597X.
LENSX® LASER: The Complete anterior segment cataract surgical experience. In: My Alcon:
Resourses for Eye Care and Health Care Professionals [online]. Novartis, 2016 [cit. 2016-04-
11]. Dostupné z: https://www.myalcon.com/products/surgical/lensx-laser/index.shtml
Moshirfar, M. Effect of iris registration on outcomes of LASIK for myopia with the VISX
CustomVue platform. Journal Of Refractive Surgery (Thorofare, N.J: 1995) [online]. 2009,
25(6), 493-502 [cit. 2016-03-20]. ISSN 1081597X.
Ong, J.K.Y. Measuring torsional eye movements by tracking stable iris features. Journal of
Neuroscience Methods [online]. 2010, 192(2), 261-267 [cit. 2016-03-20]. DOI:
10.1016/j.jneumeth.2010.08.004. ISSN 01650270.
VII. CSKO 20. 10. 2016
118
Iris Registration
Author: Bc. Hana Štolzová
Supervisor: Mgr. Ondřej Vlasák
Iris registration is one of the latest methods used to track eye movements in refractive
surgery. In practice, it can be applied to the recognition limbus and pupil and in its full version
as well as the detection of horizontal, vertical and torsional motion. Tracking eye movement
is important for proper placement of laser correction because of voluntary and involuntary
eye movements.
Use of method and its complications
Optical stabilization is now the most frequently used detection system in refractive
surgery. There could be some complications associated with shooting and subsequent
analysis.
The process of optical image stabilization should solve a problem with changing size of
the pupil, which induces a change of contrast areas of the iris in its position. Another issue
may be capturing blurred images during eye movement. However, with the modernization of
capturing technology this effect hardly ever occurs. To achieve the desired result of
measurement is also necessary to compensate the degree of illumination and direction,
reflections on the cornea, shadows and changing the direction from which the object is
recorded.
For reduction of the impact of these errors, it is advantageous to convert the structure
of the iris to polar coordinates.
Application in refractive surgery
All three sections of operation, preoperative examination, creating the ablation plan and
the operations itself, should share the same coordination system. This system must perform
two basic functions. The first is the accurate determination of the eye position, horizontal and
vertical locaion and axial orientation. The second important task is the repeatability of
measurements and subsequent analysis. Iris registration is a method that satisfies all the
above conditions.
Taking a picture
During the preoperative examination image of the iris is captured first. A special
program determines the inner and outer edge of the iris, corneal limbus and pupil, the center
and the main points of the iris (areas with high contrast). An issue can occur while examining
very bright iris, where the program is not able to find clues or edge. The problem can also
appear for irises with congenital defects such as coloboma of the iris, or nevus on limbus,
which prevents recognition of the round edge of the iris.
Iris image is taken in a sitting position, as well as preoperative diagnostic data, and all
information is immediately put together. The plan of the surgery and the structure of this
VII. CSKO 20. 10. 2016
119
procedure is assigned to the first image of the iris again. The third step in the implementation
of laser refractive treatment is converting all the data for a supine patient because changing
head and body position induce rotation of the eye. In supine position is captured one another
picture and it is paired with the previous one, so the plan of the surgery is assigned to the eye
at the correct angle.
During the operation, the stored image data are periodically or even continuously
compared with the real time image of the iris. This process is called eye tracking.
Analysis of the picture
We distinguish two types of pictures. The first is created during the preoperative
examination, it is called reference frame. The second type is taken during the operation. The
data obtained from these images are compared with data from the reference image.
The reference image is black and white and is scanned by a CCD camera with infrared
light. There is a distinction of nearly 260 shades of gray. The image contains the pupil and iris.
Some images of the iris may be partly overshadowed by a lid or algae. Overlaps should not be
greater than the width of the iris.
Capturing the patient's iris and pupil can be carried out during a wave front analysis. The
image is then subjected to analysis using several special algorithms.
First, the circular outline of the limbus and pupil margins is detected and subsequently
calculated both their centers. Normally, they are, for convenience, regarded as one identical
center of iris, which in this case could cause problems with identifying clues and significant
points of iris and centration of different phases of surgery.
The difference between the center of the iris and pupil and importance of
pupil dilation
The question arises, what is the difference between the center of the pupil and iris
center. The answer is simple. The edge of the pupil is formed by the inner boundary of the iris
and the center is calculated with respect to this interface. The center of the iris is derived due
to the limbus. Both centers are spaced from one another in terms of micrometers, but the
relative distance can be adjusted by changing the degree of dilation of the pupil.
Change in pupil size affects the relative position of its center due to the center of the
iris. If there is a different centration of diagnostic data or ablation plan and its implementation,
it could lead to the induction of unwanted aberrations. Some of the methods of optical
stabilization are already able to eliminate this phenomenon to the minimum, thanks to special
conversions or individual preoperative setting.
Iris segmentation
For unambiguous identification of the same place in both iris images, diagnostic
reference frame and the preoperative image, it is possible to analyze the iris as a whole, but
it is best to divide the iris into several sections. The iris is usually divided into 24 sectors of
15°, which is the most suitable layout relation to the maximum attainable values of
VII. CSKO 20. 10. 2016
120
physiological rotation angle of the eye. The dividing to sectors is mainly done due to better
identification of contrasting sections.
Methods of application of optical stabilization
The first way how does the stabilization method work is to focus the laser beam at a
certain point and checking the stability of the substrate. In this case, if the eye is in the
undesirable position relative to the operating device and a viewing device, laser treatment is
terminated immediately.
A second method is to continuously move the laser according to the movement of the
iris, so as to unify the image data stored in the laser system and data monitored in real time.
In practice it is possible to combine both methods and to compensate for movements
of the eye more efficiently.
The results of expert studies
Practical importance of this method is the precise centering of diagnostic data, plans of
surgery, proper adjustment of the laser and the tracking device to the patient's eye. The
studies examined in this thesis show that the operations carried out with the use of these
methods are very successful and reliability centration is very high. Significant positive impact
appears when correcting astigmatism of higher values.
References
Anderle, R. Comparison of visual acuity and higher-order aberrations after standard and
wavefront-guided myopic femtosecond LASIK. Ceska01 A Slovenska01 Oftalmologie: Casopis
Ceske01 Oftalmologicke01 Spolecnosti A Slovenske01 Oftalmologicke01 Spolecnosti [online].
2015, 71(1), 44-50 [cit. 2016-03-20]. ISSN 1211-9059.
Chernyak, D.A. From wavefront device to laser: an alignment method for complete
registration of the ablation to the cornea. Journal Of Refractive Surgery (Thorofare, N.J: 1995)
[online]. 2005, 21(5), 463-8 [cit. 2016-03-20]. ISSN 1081597X.
LENSX® LASER: The Complete anterior segment cataract surgical experience. In: My Alcon:
Resourses for Eye Care and Health Care Professionals [online]. Novartis, 2016 [cit. 2016-04-
11]. Dostupné z: https://www.myalcon.com/products/surgical/lensx-laser/index.shtml
Moshirfar, M. Effect of iris registration on outcomes of LASIK for myopia with the VISX
CustomVue platform. Journal Of Refractive Surgery (Thorofare, N.J: 1995) [online]. 2009,
25(6), 493-502 [cit. 2016-03-20]. ISSN 1081597X.
Ong, J.K.Y. Measuring torsional eye movements by tracking stable iris features. Journal of
Neuroscience Methods [online]. 2010, 192(2), 261-267 [cit. 2016-03-20]. DOI:
10.1016/j.jneumeth.2010.08.004. ISSN 01650270.
VII. CSKO 20. 10. 2016
121
Sekce posterů
Poster section
VII. CSKO 20. 10. 2016
122
The relationship between myopia and corneal astigmatism
in students of optometry in Croatia
Authors: Josipa Bagarić, Matija Dubovski
Introduction
Myopia or nearsightedness is a refractive error in which objects at a distance appear
blurry, while objects up close are seen clearly.
Nearsightedness occurs when the light entering the eye focuses in front of the retina
instead of on it. The eye relies on two critical parts to focus on an image: the cornea, which is
the clear front surface of the eye, and the crystalline lens, a clear structure inside the eye that
changes shape in order to focus on objects.
If the cornea is not smoothly curved, like in the case of people with farsightedness, the
light does not properly bend, and this results in a refractive error.
Children whose parents have nearsightedness have an increased chance to have it as
well. Development of nearsightedness can also be attributed to how a person uses their eyes.
So a person may be more likely to develop nearsightedness if they spend considerable time
reading, working at a computer or doing other close up work.
Picture 1: Myopia
Astigmatism is an irregularity in the curvature of your cornea. The clear, round dome
covering the eye's iris and pupil or in the shape of the eye's lens. Normally, the cornea and
lens are smooth and curved equally in all directions, helping to focus light rays sharply onto
the retina at the back of your eye. However, if your cornea or lens isn't smooth and evenly
curved, light rays aren't refracted properly. This is called a refractive error. When the cornea
has an irregular shape, it is called corneal astigmatism. In astigmatism, images focus in front
of and beyond the retina, causing both close and distant objects to appear blurry.
VII. CSKO 20. 10. 2016
123
Picture 2: Astigmatic cornea
Purpose
The purpose of this research is to find differences, or the relation between astigmatism
measured by traditional refraction, and corneal astigmatism measured with Oculus
topography.
Materials and Methods
The reasurch was conducted on 30 participants, students of optometry at University of
Applied Sciences Velika Gorica. On each participant cross-cylinder method was used, and on
each eye topography was done with Oculus K4. All participants have low myopia.
Picture 3: Oculus
Picture 4: Participant cross-cylinder
VII. CSKO 20. 10. 2016
124
Results
Sixty eyes of 30 patients (age 22.6 +/- 3.1 years) were included in this study. The average
VA before refraction was 0.86 +/- 0.25. After the refraction using a cross-cylinder astigmatism
was 0.75 +/- 0.67 and corneal astigmatism with Oculus topography was 1.16 +/- 0.86. There
was also difference between axes measured with cross-cylinder and topography. Average axa
measured with refraction was 89.76 and with Oculus 80.11.
Picture 5: Comparison of results
Conclusions
Disagreement between refractive and topographic astigmatic axis is common.
Approximately one third of eyes with astigmatism have > 20 degrees difference. The
astigmatism values measured for the cylinder axis correlated well between subjective
refraction and measured with topography. Thus, subjective measurements may be helpful in
determining the cylinder component of best spectacle correction and topography for corneal
astigmatism. However,topographic analysis overestimates astigmatism values in comparation
to subjective measurement of spectacle astigmatism.
References
Benjamin, W. J., Borish, I. M. Borish's clinical refraction. Philadelphia: W. B. Saunders
Company, c1998. ISBN 0-7216-5688-9.
Sinjab, M. M. Corneal topography in clinical practice (Pentacam system): basics and clinical
interpretation. 2nd ed. Jaypee Bros. Medical Pub, 2012. ISBN 93-502-5575-8.
The National Center for Biotechnology Information [online]. [cit. 2016-07-26]. Dostupné z:
www.ncbi.nlm.nih.gov
American Academy of Ophthalmology [online]. [cit. 2016-07-26]. Dostupné z: www.aao.org/
VII. CSKO 20. 10. 2016
125
Určení polohy torických intraokulárních čoček za použití
navigačního systému
Autor: Bc. Martin Fůs
Školitel: Doc. MUDr. Šárka Pitrová, CSc., FEBO
Abstrakt a cíle studie
Cílem naší studie je použití navigačního systém VERION k pooperační diagnostice
a určení pooperační polohy nitrooční čočky. Prvním krokem studie je pořízení dostatečného
množství předoperačních snímků a zvolení optimální metodiky pořizování snímků
pooperačních právě systémem VERION. Následujícím krokem bude aplikace analýzy obrazu a
určení úhlové polohy torických nitroočních čoček (IOL) pomocí vytvořeného jednoduchého
softwaru.
Principem příspěvku je přiblížení základních principů a přínosu systému VERION při
chirurgii katarakty, se zaměřením na nadcházející cíle studie. Prezentováno bude několik
pilotních pooperačních snímků a hlavní myšlenka detekce pooperační polohy nitrooční čočky.
Studie je zpracovávána v rámci diplomové práce na Českém vysokém učení technickém –
Fakultě biomedicínského inženýrství1
a ve spolupráci s Oční klinikou Jána Leštáka2
.
Úvod
Průměrný počet provedených operací katarakty neustále stoupá, stejně jako nároky na
preciznost jejího provedení. Extrakce zkalené čočky a následná implantace čočky umělé je
jednou z procentuálně nejúspěšnějších operací v medicíně. Přesto je snaha tento operační
výkon neustále zdokonalovat. Cílem zákroku není pouze samotné odstranění katarakty, ale
pomocí výpočtů zvolit optimální optickou mohutnost implantované nitrooční čočky pro
dosažení pooperační emetropie. Pooperační zrakovou ostrost lze považovat za jedno z
nejvýznamnějších měřítek úspěšnosti celého chirurgického zákroku.
Problematika torických nitroočních čoček
U pacientů s vyšším rohovkovým astigmatismem je pro dosažení zmíněného cíle nutná
implantace torické IOL. Totožnost osy implantační a plánované korekční osy TIOL je při
správném výpočtu tím nejvýznamnějším kritériem úspěšnosti. Procedura centrace torické
čočky je znesnadněna několika faktory. Změnou polohy těla pacienta (při uložení na operační
lůžko) dochází k cyklorotaci oka, jejíž míra je zcela individuální. Nelze tak s jistotou určit
implantační osu. Řešením se stalo manuální barevné předoperační značení implantační osy
přímo na oko pacienta pomocí úhlového měřítka. Na štěrbinové lampě je naznačena
horizontální nebo vertikální rovina a následně znázorněna implantační osa. Manuální značení
je časově náročné a vyžaduje velmi dobrou spolupráci pacienta. Přesnost a spolehlivost
značení samozřejmě významně kolísá se zručností a zkušeností operatéra. Běžně je
dosahováno přesnosti v řádu desítek úhlových stupňů. Což je s ohledem na výši optické
mohutnosti nitrooční čočky a zrakovou ostrost poměrně vysoká hodnota.
VII. CSKO 20. 10. 2016
126
Pro standardizaci operačního zákroku a zejména pro spolehlivé určování polohy torické
IOL byl vyvinut obrazově řízený navigační systém VERION. Nevyžaduje přímou spolupráci
pacienta a zajistí přesnost i úsporu času.
Systém VERION – předoperační vyšetření a chirurgický plán
Obrazem řízený navigačnísystém VERION je technologie pro real time navigaciv procesu
operace katarakty pomocí referenčního snímku (obrazu). Systém je tvořen Referenčním
modulem, Vision Plannerem, MID (Microscope integrated display) a Digitálním markerem.
Systém tedy kompletně řídí veškeré kroky procesu chirurgie katarakty.
Referenční modul (na obrázku 1) zaznamenává data keratometrie včetně významných
struktur duhovky, sklerálních cév, velikost pupily a limbu. Tento komplex dat vytváří takzvaný
„eye-print“ neboli referenční snímek oka (obrázek 2).
Obrázek 1: Referenční modul systému VERION.
VII. CSKO 20. 10. 2016
127
Obrázek 2: Referenční snímek oka („eye-print“) a měřená data.
Data keratometrie jsou automaticky online přenesena do počítače se softwarem Vision
Planner. Online sdílení informací jednotlivých součástí systému výrazně minimalizuje vznik
transkripčních chyb. V přehledném prostředí Vision Planneru je vytvořen operační plán
(náhled na obrázku 3) lze volit odlišné výpočtové vzorce pro mohutnost nitrooční čočky,
konkrétní typ čočky s přehledem variant mohutností a předpokládanou residuální ametropií,
plánování optimální implantační síly i osy torické IOL nebo relaxační incize. Vytvořený operační
plán s kompletními údaji o pacientovi a vizualizací zákroku je online exportován do Digitálního
markeru (propojeného s MID) na operačním sále.
VII. CSKO 20. 10. 2016
128
Obrázek 3: Printscreen operačního plánu v softwaru Vision Planner.
Virtuální navigace
Na základě referenčního snímku a operačního plánu je MID a Digital markerem
vytvořena virtuální projekce operačního plánu. V markeru je možné kontrolovat základní
informace o pacientovi a lze změnit nebo upravit operační plán, což lze i v průběhu operace
(obrázek 4).
Obrázek 4: Printscreen operačního plánu v softwaru Vision Planner.
Na obrazovce markeru je zobrazen totožný obraz, který operatér vidí v operačním
mikroskopu. Po kontrole koincidence referenčního snímku a aktuálního snímku z mikroskopu
VII. CSKO 20. 10. 2016
129
s MID je zahájen proces virtuální real time navigace. Systém s vysokou frekvencí porovnává
referenční a aktuální snímek oka a přizpůsobuje mu navigační obrazce. Tímto způsobem je
kopírován případný pohyb očí a zejména cyklorotace. Vizualizace operačních kroků a jejich
způsob navigace jsou na obrázku 5.
Obrázek 5: Virtuální projekce navigace operatéra: A – rohovkové incize; B –
kapsulorhexe; C – centrace čočky do osy vidění; D – zobrazení implantační
osy.
První fází operace je vytvoření rohovkových incizí, kdy systém operatéra naviguje pro
umístění primární incize i paracentéz. Operatér tak jednoznačně zohlední cyklorotaci a
kontrolovanou pozicí řezů minimalizuje odchylku pooperačního indukovaného astigmatismu
rohovky. Následuje kapsulorhexe, jejíž parametry (velikost i centrace) jsou volitelné. Po
procesu fakoemulzifikace obsahu čočkového pouzdra následuje implantace nitrooční čočky.
Při tomto kroku lze operatéra navigovat pro centraci čočky do osy vidění a zejména znázornit
implantační osu torické IOL. Operatér je schopen s naprostou jistotou i přesností umístit
korekční osu torické IOL do implantační osy. Úspěšná centrace je závěrečnou fází na
operačním sále.
Pooperační vyšetření jako motivace studie
Úspěšnou implantací proces operace katarakty nekončí. Jako její významnou součást
považujeme pooperační diagnostiku. Běžně se kontrola operovaného pacienta provádí
následující den po zákroku a po následujících dvou týdnech. V pooperační diagnostice je nutné
stanovit, kontrolovat a predikovat případné nežádoucí indukované stavy. Pro zrakovou ostrost
u očí korigovaných torickou IOL je nejpodstatnější její pozice. V ideálním případě úhlová pozice
VII. CSKO 20. 10. 2016
130
čočky odpovídá potřebné korekční ose. Pokud v některých případech není dosaženo
optimálního visu, je nutné stanovit příčinu. Mezi nejčastější patří právě decentrace torické IOL.
Nutné je však spolehlivě tuto příčinu stanovit, kvantifikovat a zhodnotit, případně vyloučit její
potenciální vliv.
Předpokladem využití virtuálního navigačního systému je minimalizace decentrace
torické IOL. Způsob jak tento předpoklad ověřit, vyhodnotit přínos pomocí faktických dat a
přitom využít jeho vlastních komponent je motivací této studie.
Stanovení pozice IOL
Referenční jednotka umožňuje pooperační keratometrické vyšetření operovaného oka
pro kalkulaci indukovaného rohovkového astigmatismu. Před finálním pořízením
pooperačního referenčního snímku je kamera v takzvaném IR (infra-red) módu, kdy je pomocí
reflexe infračervených diod měřící hlavy zjišťována optimální vzdálenost měřící hlavy od
rohovky. Pokud jsou pacientovi před vyšetřením aplikována mydriatika a jimi způsobená
mydriáza je dostatečně velká, jsme v tomto módu schopni zachytit snímek nitrooční čočky ve
stupních šedi a zároveň s úhlovou růžicí odpovídající předoperačnímu snímku, tedy i
předoperačnímu plánu. Forma takto pořizovaných snímků je prezentována obrázkem 6.
Snadnost a úspěšnost pořízení takového pooperačního snímku je pochopitelně závislá na
individuální mydriáze jednotlivých pacientů a na vyšetřovacích podmínkách okolí.
Alternativní technikou pořízení pooperačního snímku je využití digitálního markeru ve
spojení s operačním mikroskopem. Pacient je umístěn na operační lůžko, přičemž je do
chirurgova mikroskopu virtuálně promítnut původní předoperační plán. Pořízením fotografie
včetně i bez projekce operačního plánu budeme schopni zohlednit cyklorotaci oka
způsobenou polohou pacienta. Lehká komplikovanost pořízení takového snímku je
kompenzována jeho kvalitou a možností vizualizace centračních bodů. Snímky pořízené
digitálním markerem jsou prezentovány obrázkem 7.
VII. CSKO 20. 10. 2016
131
Obrázek 6: Pooperační snímky pořízené Referenčním modulem ve stupních
šedi.
Obrázek 7: Pooperační snímek nitrooční čočky pořízený prostřednictvím
Digitálního Markeru.
VII. CSKO 20. 10. 2016
132
Základní principy určení polohy nitrooční čočky
Hlavní myšlenkou je využití znalosti modelu implantované čočky a jeho detekce v obrazu
(obrázek 8). V případě pořízení pooperačního snímku referenční jednotkou nejsme schopni
identifikovat centrační body torické čočky, jelikož je snímek ve stupních šedi. Tyto body jsou
však umístěny standardním způsobem v identické poloze vůči haptikám nitroočních čoček.
V případech, kdy dostatečná mydriáza odhalí alespoň jednu z haptik, budeme schopni
předpokládat polohu centračních bodů nitrooční čočky a určit tak její pozici. Tento předpoklad
můžeme využít i v případě snímků pořízených digitálním markerem jako kontrolní
mechanismus, ačkoliv jsou centrační body poměrně snadno rozlišitelné. Po detekci
konkrétního modelu čočky v daném pooperačním snímku je nutné určit její aktuální úhlovou
polohu a porovnat ji s operačním plánem za využití před i pooperačního referenčního snímku.
Součástí studie je vytvoření jednoduché aplikace pro usnadnění určení polohy a decentrace
torické čočky.
Obrázek 8: Model torické IOL: AcrySof® IQ Toric IOLs SN6Tx by Alcon.
Korekční osa je určena spojnicí šesti protilehlých bodů. Dvojice haptik slouží
pro stabilizaci IOL v kapsule. Všechny rozměry jsou uvedeny v milimetrech.
Obrázek 9: Určení polohy čočky – korekční osa je totožná s osou implantační
(10°).
VII. CSKO 20. 10. 2016
133
Výsledky studie
Zaměřením studie je korekce rohovkového astigmatismu pomocí torických IOL za využití
moderní techniky real time navigace v průběhu chirurgie katarakty. V příspěvku jsme
představili základní princip navigace systému VERION, zmínili důvody a techniky pooperačního
vyšetření a stanovení polohy torické IOL. Výsledkem první části projektu jsou pořízené pilotní
pooperační snímky nitroočních čoček pomocí Referenčního modulu a Digitálního markeru.
Chirurgem provádějícím veškeré chirurgické zákroky zahrnuté do studie je školitel Doc.
MUDr. Šárka Pitrová. Předoperační i pooperační vyšetření a řízení virtuální navigace provádí
autor studie M. Fůs. V období od března 2016 do července 2016 podstoupilo operaci katarakty
pomocí systému VERION dle záznamů cca 150 očí 110 pacientů. Tento soubor považujeme za
dostatečný pro zisk nezbytných zkušeností.
Nadcházející fází studie je pokračování v nastoleném trendu asistence navigačního
systému v operačním procesu katarakty se zaměřením na pacienty s operačním plánem pro
torickou IOL. Závěrů chceme docílit prostřednictvím vytvoření jednoduché aplikace pro
detekci polohy čočky a určení hodnoty případné decentrace. Tato data budou využita pro
optimalizaci pooperační zrakové ostrosti, určení časově závislé stability polohy torické IOL a
jako zpětná vazba pro operatéra.
Reference
VERION Reference Unit: VERION Measurment Module & VERION Elevation Table. Alcon a
Novartis company, 2014. User Manual – Software version 2.5.
VERION Digital Marker M with Microscope Integrated Display. Alcon a Novartis company,
2014. User Manual – Software version 2.5.1.
VERION Reference Unit: VERION Vision Planner. Alcon a Novartis company, 2014. Quickguide
for Software version 2.5.1.
Kuchynka, P. Oční lékařství. 1.vyd. Praha: Grada, 2007. ISBN 978-802-4711-638.
Vlková, E., Vlk, F., Pitrová, Š. Lexikon očního lékařství: výkladový ilustrovaný slovník. 1. vyd.
Brno: František Vlk, 2008. ISBN 978-802-3989-069.
Henderson, B. A., Gills, J. P. 2011. A complete surgical guide for correcting astigmatism: an
ophthalmic manifesto. 2nd ed. Thorofare, NJ: SLACK Inc., xvi, 247 p. ISBN 15-564-2935-5.
ALCON LABORATORIES, NOVARTIS COMPANY PRODUCT INFORMATION: ACRYSOF IQ TORIC:
AstigmatismIOL. United Kingdom, 2014. Dostupné také z: ecatalog.alcon.com/iol_dfu/40-500-
143_us_en.pdf
Alcon Eye Care and Healthcare Professionals[online]. [cit. 2015-12-28]. Dostupné z:
www.myalcon.com
VII. CSKO 20. 10. 2016
134
Determining the Position of Toric IOLs Using a Navigation
System
Author: Bc. Martin Fůs
Supervisor: Doc. MUDr. Šárka Pitrová, CSc., FEBO
Abstract
Objective of the study is using the VERION image guided system to postoperative
diagnostic and to determining the position of toric intraocular lens (IOL). The first step is
capturing preoperative images and find the way for capturing the postoperative image of
intraocular lens position using the VERION. Next step of this study will be applying image
processing and analysis to determine IOL’s angular position by using simple application.
The principle of article is explaining the basics of image guided system in cataract
surgery, with focusing on the upcoming goals of study. We will present several pilot
postoperative images and the main idea of detection position toric IOL. The study is processed
at Czech Technical University in Prague, Faculty of Biomedical Engineering1
and in cooperation
with Eye clinic of Jan Lešták2
.
Introduction
The average number of cataract surgery is still rising, as well as the demands on the
precision of its execution. Extraction clouded lens and the artificial lens implantation is one of
the most successful operations in medicine. Nevertheless the improving of this procedure is
necessary. The goal of surgery is not only removing the cataracts, but to choose the optimal
optical power of the lens implanted to achieve postoperative emmetropia. Postoperative
visual acuity can be considered like one of the most important measures of success in the
surgical procedure.
Problematic of toric intraocular lenses
For the patients with higher value of corneal astigmatism is implantation of toric IOL
necessary. The coincidence of implantation axis and correction axis of intraocular lens is the
most important for patient’s optimal visual acuity. The centration is very difficult because of
the cyclorotation. When the patient lie on the surgery bed, eyes are rotated inside and
upstairs. We are not able to determine the right axis of implantation. The most popular
solution is manual color marking directly on the patient´s eye using angle measuring
instrument. The horizontal or vertical plane is marked at first (at slit lamp) and then the axis
of implantation. This manual technique of marking is very time-consuming. Well cooperation
with patient is needed and precision is varying with experiences and skills of surgeon. The
common precision is about tens of degrees. This is very high value for visual acuity controlling.
To standardization and higher accuracy in toric IOL centration was developed the image
guided system.
VII. CSKO 20. 10. 2016
135
System VERION – preoperative assessment and operating plan
Image guided system is a new technology for real-time navigation during cataract
surgery. Thanks this system we are able to make preoperation assessment and control all
steps of surgery. The system consists of Reference unit, Vision Planner, Digital marker and
Microscope integrated display (MID).
The Reference unit (in figure 1) captures a high resolution image of the patient’s eye.
The software detects the limbus area, location of scleral vessels and important points of iris
structure. That complex creates the “eye-print” (fig. 2) or reference image of patient’s eye.
Figure 1: Reference Module of VERION.
Figure 2: Reference image (”eye-print”) and measured data.
VII. CSKO 20. 10. 2016
136
Data of keratometry are automatically transferred to the Vision planner (using online
sharing for minimize the transcription errors). That’s software for creating the operation plan.
We are able to choose formulas for IOL power calculation, model of IOL, value of residual
refraction and planning of toric IOL implantation procedure. All together in one place for
choosing the best variant for patient. The result is complete surgery plan with all information
about patient and visualization of surgery steps.
Figure 3: Printscreen of surgical plan in Vision Planner.
Virtual navigation
The reference image transported online to the Digital marker and MID is used for virtual
projection of navigation. In marker is able to control or manage all data of operation plan
again. That is possible during the operation too.
Figure 4: Printscreen of surgical plan in Vision Planner.
VII. CSKO 20. 10. 2016
137
In digital marker is displayed the same image of surgeon’s microscope. After controlling
all data and coincidence of reference and actual image is possible to start virtual navigation.
MID creates real time virtual projection in one of the surgeons ocular. System compares
reference and actual image and adjust the navigation pictures. So this projection is noncontact
marking. The projection adjusts to eye movements and especially takes into account the
cyclorotation of the eye. Real visualization of navigation principle is in figure 5.
Figure 5: Virtual projection of navigation: A – corneal incisions; B –
capsulorhexis; C – intraocular lens centration to visual axis; D – projection
axis of implantation.
The first phase of surgery is creating corneal incisions. The system is navigating the
surgeon for precise placing the corneal incisions and paracenthesis. So this way is possible to
take in to account cyclorotation and minimizing the deviation of corneal surgical induced
astigmatism. Next phase is capsulorhexis, there we can chose different parameters of
navigation, like centration to visual axis or the diameter. After facoemulsification and cleaning
the lens capsule comes the IOL implantation. The surgeon is navigated to centration the IOL
in visual axis and especially to axis of implantation. Is very important to implant the toric IOL
to the right axis of implantation. When the angle position of toric IOL is optimal, in coincidence
with axis of implantation, is it the last step of surgery.
Postoperative examination like motivation of study
The successful implantation isn’t the real over of cataract procedure. Very important
part is postoperative examination. First control is commonly next day after surgery and then
for the following two weeks. In postoperative diagnostic is important to check and predict
VII. CSKO 20. 10. 2016
138
potential adverse induced states. For the visual acuity in eyes with toric IOL is the most
important its position. In ideal case is the angle position right in axis of correction. But in some
cases isn’t the visual acuity optimal and is necessary to say why. The most common cause is
toric IOL decentration. However it is necessary to reliably determine right cause, quantify and
to evaluate its potential impact, or possibly completely excluded.
Prerequisite for the using of virtual navigation system is to minimize decentration toric
IOL. A way to verify this assumption, to evaluate the benefits of using factual data and taking
advantage of its own components is the motivation of this study.
Determining the position of toric IOL
Reference unit allows postoperative keratometric assessment of operated eye for
surgically induced astigmatism calculation. We found, that using this “infra-red mode in
grayscale” for focusing of the measuring head allowed us to change frontal plane of focusing,
just easy like in microscopes. The system reports bad focus without capturing (because the
option is on the front surface of cornea), but thanks print-screen mode we are able to create
the image of the lens position. If the patient is applied mydriatics before the examination and
it when the mydriasis is big enough, we're able to capture image of intraocular lens in
grayscale. Simultaneously with angular rosette adequate preoperative image, or the
preoperative plan respectively. The captured images are in figure 6. Easiness and success of
the postoperative image understandably depends on the individual patient and mydriasis and
various investigation on ambient conditions.
Alternative way to capture the postoperative image of lens is with using Digital marker
connected with microscope. Patient (after mydriatics application) is placed to operating bed
and MID project the virtual operating plan. In Digital marker we are able to capture image of
actual lens position, determined with pounts of correction axis and determine the axis of
implantation. Difficult capturing and manipulation with patient is compensate by image
quality and visibility of correction points.
VII. CSKO 20. 10. 2016
139
Figure 6: Postoperative images captured by Reference Module in grayscale.
Figure 7: Postoperative image of intraocular lens captured by Digital Marker.
VII. CSKO 20. 10. 2016
140
Basic principles of determining the toric IOLs position
Main idea is using the postoperative images and knowing the model of toric IOL (in the
figure 8). Then use the object detection in images. In image from Reference module we are
not able to determine centration points of toric IOL, because the image is original in the
grayscale. But these points are placed to identical position, nearby haptics of IOL. So when the
mydriasis will be enough and we will see at least one haptic, we are able to predict the position
of these points. Thanks the original model, we will determine the actual position of toric IOL.
This technique we can use in images by Digital marker like control mechanism too. After
determining the actual position we compare these data with reference image and surgeon
plan.
Figure 8: Model of toric IOL: AcrySof® IQ Toric IOLs SN6Tx by Alcon. The axis
of correction is given by six opposing points. Two haptics are for stabilization
of IOL in lens capsule. All dimensions in millimeters.
Figure 9: Determining the IOL position – axis of correction is identical to the
implant axis (10°)
VII. CSKO 20. 10. 2016
141
Conclusions
We are focused on the correction corneal astigmatism through artificial toric IOLs with
advanced techniques of real-time navigation during the cataract surgery, connected with
preoperative assessment. In this paper we suggested methods of cooperation, using the
VERION Image guided system and its benefits. We indicated the reasons and way how to take
the image of IOLs in postoperative assessment. We presented firsts successful postoperative
images and introduced the main idea of toric IOL detection.
The surgeon performing all surgery procedures is doc. MUDr. Šárka Pitrová. All
preoperative assessments, controlling of Digital marker during surgery, all images and
postoperative assessments were done by M. Fůs. From March 2016 to July 2016 were
operated for cataract by using system VERION about 150 eyes of 110 patients. This number of
cases is sufficient for getting experiences.
Next phase of study is continuing of trend of navigation system in operating process
cataract surgery using assistance of navigation system with focusing on patients with
operation plan for toric IOL. We want to reach the objectives by creating simple application
for determining the position of IOL and the value of eventual decentration. These data will be
used for optimalization of postoperative visual acuity, evaluating of time depended position
of toric IOL and creating feedback ratings of system for surgeon.
Next step of this study will involve create simple application for IOLs detection and
position determine.
References
VERION Reference Unit: VERION Measurment Module & VERION Elevation Table. Alcon a
Novartis company, 2014. User Manual – Software version 2.5.
VERION Digital Marker M with Microscope Integrated Display. Alcon a Novartis company,
2014. User Manual – Software version 2.5.1.
VERION Reference Unit: VERION Vision Planner. Alcon a Novartis company, 2014. Quickguide
for Software version 2.5.1.
Kuchynka, P. Oční lékařství. 1.vyd. Praha: Grada, 2007. ISBN 978-802-4711-638.
Vlková, E., Vlk, F., Pitrová, Š. Lexikon očního lékařství: výkladový ilustrovaný slovník. 1. vyd.
Brno: František Vlk, 2008. ISBN 978-802-3989-069.
Henderson, B. A., Gills, J. P. 2011. A complete surgical guide for correcting astigmatism: an
ophthalmic manifesto. 2nd ed. Thorofare, NJ: SLACK Inc., xvi, 247 p. ISBN 15-564-2935-5.
ALCON LABORATORIES, NOVARTIS COMPANY PRODUCT INFORMATION: ACRYSOF IQ TORIC:
AstigmatismIOL. United Kingdom, 2014. Dostupné také z: ecatalog.alcon.com/iol_dfu/40-500-
143_us_en.pdf
Alcon Eye Care and Healthcare Professionals[online]. [cit. 2015-12-28]. Dostupné z:
www.myalcon.com
VII. CSKO 20. 10. 2016
142
Internetový a samoobslužný prodej – nový fenomén
v oboru optika a optometrie, výhody a rizika pro klienta
Autor: Bc. Michaela Gagová
Školitel: Mgr. Petr Veselý, DiS., Ph.D.
Anotace
Toto sdělení se zabývá výhodami a nevýhodami, se kterými se může klient setkat při
nákupu optických pomůcek přes internet. Její první část je věnována všeobecné
charakteristice internetového a kamenného obchodu. Dále jsou zmíněny i hlavní výhody a
nevýhody těchto dvou typů obchodů. Další část se již týká obchodů, které se věnují prodeji
optických pomůcek. Jsou v ní popsány postupy korekce brýlemi a kontaktními čočkami jak v
kamenné oční optice, tak v internetovém obchodu. Na konci každé části jsou shrnuty rizika, na
které si klient musí dát při nákupu přes internet pozor. V závěrečné části práce jsou popsána
pravidla reklamace a základní legislativní předpisy týkající se provozu.
Úvod
V dnešní době jsou nákupy přes internet na každodenním pořádku. Mnoho zákazníků
tento druh nakupování upřednostňuje a to jak z důvodu nižší ceny, tak z důvodu pohodlí.
Internetové obchodování již zasáhlo také do oboru optika a optometrie. Na českém internetu
je nespočet e-shopů nabízejících brýle nebo kontaktní čočky online. Své zákazníky lákají hlavně
na ceny, které jsou nižší než v očních optikách. Jsou ale brýle či kontaktní čočky zakoupeny na
internetu pro klienta bezpečné? Cílem této bakalářské práce je tedy zejména vytyčit rizika, ale
i některé výhody, se kterými se klient setká při nákupu brýlí či kontaktních čoček přes internet.
Brýlová korekce v internetové oční optice
Počet lidí, kteří by si koupili dioptrické brýle na internetu, v naší zemi bohužel stále
stoupá. Je ovšem také rozdíl v tom, jestli si koupí obrubu i se skly nebo pouze obrubu
samotnou. V případě, že si koupí pouze obrubu, je může také čekat spousta nepříjemností a
komplikací. Počínaje tím, že si brýle nemůžou předem vyzkoušet. Tím pádem nebudou vědět,
jak v nich budou vypadat ani jak se v nich budou cítit. Obruba může tlačit, může být příliš těžká.
Zákazník tedy riskuje, že úplně zbytečně vyhodí peníze. Má samozřejmě možnost je do určité
doby bez udání důvodu vrátit, musí je ovšem správně zabalit a odeslat. To znamená zaplatit
poštovné a poté čekat (většinou měsíc) na jejich odeslání zpět. Mnohem horší je ovšem koupě
kompletních dioptrických brýlí. Laik si jen velmi těžko dokáže vybrat vhodná skla nebo si sám
sobě změřit PD. V prvé řadě nemá zákazník absolutně tušení o tom, jak mu vybrané brýle
budou sedět. Na mnoha internetových stránkách s optickým zbožím má možnost si „brýle
vyzkoušet“, a to za pomocí webové kamery na jeho počítači. Ovšem z toho se zákazník
nedozví, zda mu brýle opravdu sedí nebo zda jej netlačí. Přesně ani neví, jak daleko má hlavu
k monitoru přisunout, aby velikost brýlí na obličeji byla reálná. Správnou anatomickou úpravu
získávají brýle v rukách odborníka a ne pomocí webové kamery na internetu. A nyní už
k samotnému nákupu brýlí. Krok po kroku si projdeme průběh tohoto procesu. Jako první je
VII. CSKO 20. 10. 2016
143
po zákazníkovi požadováno doplnění dioptrických hodnot, které opíše ze svého předpisu.
Některé obchody také zákazníkům nabízí možnost tyto hodnoty překontrolovat a to tím
způsobem, že svůj předpis oskenují a poté jej vloží na stránku. Ovšem tato funkce ne vždy
funguje. Další požadovanou hodnotou je PD. Obchody nabízí mnoho možností, jak si jej
zákazník může změřit. Není ale pravidlem, že nabízený návod správně pochopí a proto si jej
velmi snadno může změřit špatně. Ne vždy chce také obchod hodnotu zvlášť pro pravé a levé
oko, což je taky špatně. Dalším krokem je výběr materiálu čoček. Zákazníkovi jsou nabídnuty
cca 4 typy čoček a to u minerálních i plastových materiálů. Ke každému typu je většinou
připsán index lomu. To ovšem laikovi neřekne skoro nic, vidí jen rozdíl v ceně. Obchod většinou
nabídne optimální volbu pro zadané hodnoty korekce. Zákazník ale bohužel neví, zda
potřebuje skla ztenčená nebo skla s indexem lomu 1,56. Neví, zda mu nebudou brýle
s minerálními čočkami padat kvůli jejich větší váze. Po vyplnění všech náležitostí následuje
výběr způsobu platby a doručení. K ceně je tedy započítána cena poštovného.
Nákup dioptrických brýlí na internetu se tedy může zdát finančně výhodnější, rychlejší a
pohodlnější. Žádný odborník jej ale z mnoha důvodů nedoporučí. Brýle bez správné
anatomické úpravy nemůžou klientovi nikdy správně padnout a nebudou nikdy splňovat
podmínky správné korekce. Pupilární vzdálenost si zákazník nemusí vždy změřit správně. I
kdyby jej změřil správně, chybí zde možnost doplnění hodnoty výšky středu zornice. Žádný
internetový obchod s optickým zbožím tuto možnost nenabízí. Centrace a tedy i samotná
korekce nemůže být správná. Nákup brýlí na internetu je tedy velmi riskantní a zakoupenými
brýlemi si zákazník může snadno uškodit. Špatně nacentrované brýle mohou způsobovat řadu
problémů počínaje bolestmi hlavy a očí, pocitem únavy atd. Brýle, které nebudou správně
anatomicky upravené, budou zákazníkovi padat a budou jej tlačit. Největším problémem je
tedy zcela určitě chybění lidského a osobního přístupu očního optika či jiného odborníka.
Korekce kontaktními čočkami v internetové oční optice
Optickou pomůckou, která je na internetu nejčastěji pořizována, jsou právě kontaktní
čočky a příslušenství k nim. V roce 2012 byl zaznamenán nárůst zájmu o kontaktní čočky o
45%. Lidé si kontaktní čočky kupují na internetu ze dvou hlavních důvodů. Prvním z nich je
nízká cena – kontaktní čočky jsou na internetu opravdu levnější a to z důvodu toho, že
kontaktolog si k jejich ceně musí připočítat náklady na vyšetření a kontroly. A druhým
důvodem je pohodlí nákupu z domova a rychlost dodání. Kontaktní čočky a roztoky jsou
považovány za již hotový výrobek a tím pádem při jejich nákupu přes internet nehrozí velké
riziko. Nákup by měl být tedy bezpečný a čočky by zraku neměly nijak uškodit. Toto ovšem
platí pouze v případě, že zákazník před tímto nákupem absolvuje profesionální aplikaci a
všechna potřebná vyšetření a pokud mu odborník sdělí přesné informace o tom, jaký typ čoček
je pro něj vhodný. Musí tedy znát všechny důležité hodnoty, jako jsou např. poloměr křivosti,
průměr a materiál kontaktní čočky. Zároveň je důležité vědět, jaký roztok se k vybraným
čočkám používá. Zákazník si tedy na vybrané internetové stránce zvolí pro něj vhodný typ
kontaktních čoček. Stejně jako u nákupu brýlí se po něm požaduje doplnění jeho dioptrických
hodnot. Poté si výrobek jen „vloží do košíku“ a doplní informace, jako jsou jméno a adresa.
K ceně se samozřejmě opět připočítává poštovné, které většinou po překročení určité částky
bývá zdarma. Nákup je velmi rychlý a pohodlný tím, že se provádí přímo z domova.
VII. CSKO 20. 10. 2016
144
Nákup kontaktních čoček na internetu není tak riskantní jako nákup dioptrických brýlí.
Podle odborníků má ovšem také nevýhody. Tou největší je to, že při nákupu zákazník vůbec
nepřijde do styku s kontaktologem. Už jen jediným pohledem dokáže odborník poznat, zda
klient netrpí nějakou patologií rohovky, která může být například nadměrně zarudlá. Klient si
tento problém vůbec nemusí uvědomovat. Dokonce je i prokázáno, že lidé, kteří si kontaktní
čočky na internetu kupují, pravidelně zapomínají chodit na pravidelné prohlídky. Tím stoupá
riziko jakýchkoli komplikací. Nejčastějším problémem bývá přenášení čoček. Ve snaze ušetřit
totiž lidé nosí čočky delší dobu, než je doporučeno výrobcem. Pro jejich zrak je to velmi
nebezpečné a to z důvodu zvýšeného rizika přenosu infekce. Mnoho zákazníků si také myslí,
že pokud čočky rozbalí a nenosí je například týden, prodlužuje se jejich doba nošení o sedm
dní. To je ovšem omyl, protože se nepočítá doba, po kterou mají čočku v oku, ale doba od
jejich rozbalení a vyjmutí z původního balení. Dále musí myslet také na každodenní výměnu
roztoku a pravidelnou výměnu pouzdra na čočky, kterou je vhodné provádět alespoň jednou
za tři měsíce. Při tomto nákupu tedy nehrozí až tak velké riziko. Ovšem pouze za předpokladu,
že zákazník opravdu ví, co potřebuje, bude pravidelně navštěvovat svého kontaktologa a bude
se o čočky poctivě starat.
Závěr
Klienty láká při nákupu přes internet hlavně příslib nízké ceny. Zapomínají ovšem na to,
že při nákupu brýlí v optice jsou k jejich ceně připočítány služby optika. Tyto služby a samotný
osobní přístup odborníka jsou ovšem nedílnou součástí správné korekce. Nehledě na to, že
brýle zakoupené na internetu nejsou anatomicky upravené a nejsou ani korektně
nacentrované. Zákazník si jimi tedy může snadno ublížit. Při nákupu kontaktních čoček na
internetu nehrozí zákazníkovi tak velké riziko jako při nákupu brýlí. I přesto není jejich nákup
přes internet doporučován. Nositel kontaktních čoček totiž může snadno zapomínat na
pravidelné kontroly u svého kontaktologa, čímž může docházet ke zdravotním problémům. Na
závěr je tedy důležité říci, že osobní a odborný přístup optometristy či optika je při korekci
stěžejní. Také samotný klient by si měl toto uvědomovat. Vhodným řešením by bylo
upozorňování veřejnosti na možná rizika tohoto nákupu např. formou komunikace
s odborníkem.
Zdroje
Beneš, P. Nákupem čoček přes internet si můžete ohrozit zrak, řekl optometrista [online
24.2.2014]. http://ona.idnes.cz/on-line-rozhovor-kontaktni-cocky-dqn-
/zdravi.aspx?c=A141125_120251_zdravi_pet
FEEDIT.CZ, 2013. Zájem o kontaktní čočky na internetu roste, lidé za ně v loňském roce utratili
téměř půl miliardy. [online 12.12.2014]. http://www.feedit.cz/wordpress/2013/04/03/zajem-
o-kontaktni-cocky-na-internetu-roste-lide-za-ne-v-lonskem-roce-utratili-temer-pul-miliardy/
OTTLENS, 2012. Nedisciplinovaných uživatelů kontaktních čoček přibývá. [online 12.12.2014].
http://www.ottlens.com/clanky/nedisciplinovanych-uzivatelu-kontaktnich-cocek-pribyva
VIDENI.CZ, 2010. Nakupování přes internet. Ano nebo ne? [online 9.12.2014].
http://www.videni.cz/produkty/47-nakupovani-pres-internet-ano-nebo-ne
VII. CSKO 20. 10. 2016
145
Internet sales and self-service - a new phenomenon in the
field of optics and optometry, benefits and risks for the
client
Author: Bc. Michaela Gagová
Supervisor: Mgr. Petr Veselý, DiS., Ph.D.
Summarized
This thesis deals with the advantages and disadvantages with which the client may
encounter when buying optical devices over the internet. The first part is devoted to general
characteristics of the Internet and stone shop. Furthermore, it also mentions the main
advantages and disadvantages of these two types of stores. The second part is concerned with
shops dedicated to selling optical aids. It describes procedures of correction with glasses and
contact lenses at optician´s and in the Internet shop. Risks for which the client must watch out
while buying over the Internet are summerized at the end of each section. The final part is
describing the basic rules of the complaint and legislative provisions relating to the operation.
Introduction
Nowadays the Internet purchases are on the order of the day. Many customers prefer
this kind of shopping because of lower prices and because of the convenience. Internet
commerce has already intervened in the field of optics and optometry. There are countless eshops
on the Czech Internet offering glasses or contact lenses online. Their customers are
attracted mainly to prices that are lower than in ophthalmic optics. But are glasses or contact
lenses purchased on the Internet safe enough for the client? The aim of this thesis is thus to
set out the risks,but also some advantages to which the client encounters when buying glasses
or contact lenses on the Internet.
Spectacle correction on the Internet
The number of people who would buy eyeglasses online, in our country, unfortunately,
is still growing. But it is also a difference in whether you buy a skirt and glasses or only trim
itself. In the event that buys only the flange can also expect a lot of trouble and complications.
Starting with the fact that glasses can not pass a test. Thus, they will not know how they will
look in them or how they will feel in them. Trim can push or it might be too heavy. The
customer therefore risks being needlessly thrown away money. It has a possibility to a certain
time period without giving a reason to return, must, however, correct packaging and shipping.
That means pay postage and then wait (usually a month) to send them back. Much worse,
however, is the purchase of complete spectacles. It can be very difficult for a layman to choose
a suitable glass for himself or to measure his own PD. First, the customer has absolutely no
idea of how the collected glasses will suit. On many websites with optical products he has the
opportunity to "try out glasses"using a webcam on his computer. However, from the customer
to know whether he really fits glasses or if it will not push. Exactly not even know how far has
VII. CSKO 20. 10. 2016
146
the head to monitor move close to the size of the glasses on his face was real. Anatomically
correct adjustment gain glasses in the hands of an expert and not using a webcam on the
Internet. And now to the actual purchase of glasses. Step by step we go through this process.
The first it is required to supplement prescription values cribs from your prescription. Some
stores also offer customers the opportunity to check these values through scanning your
prescription from the machine and then insert it into the page. However, this feature does not
always work. Another desired value is PD. Stores offer many options for the customer to
measure them. But there is no rule that the customer will understand these instructions so
they can easily be measured wrong. Not always the shop wants to store values separately for
left and right eye, which is also wrong. The next step is the selection of lens material. The
customer is offered about 4 types of lenses and for mineral and plastic materials. For each
type is mostly attributed to the refractive index. However, it will say almost nothing to a
layman, the only thing he sees is the difference in price. Business usually offers the optimum
choice for the desired correction value. The customer but unfortunately does not know
whether it needs thinned glass or glass with a refractive index of 1.56. He does not know that
the glasses with mineral lenses can fall due to their greater weight. After completing all
formalities the next step is to choose payment and shipping method. The shipping price is
therefore included.
Buying prescription glasses online may therefore seem more cost-effective, faster and
more convenient. No expert however would recommend it for many reasons. Glasses without
proper anatomical modifications can never properly fit and will never satisfy the conditions
for proper correction. Pupillary distance customer may not always measure correctly. Even if
he measures them correctly, there is not a possibility to add the vertical pupillary distance. No
online shop with optical products offer this option. Centering and thus the correction itself is
not correct. Buying glasses online is very risky and purchased glasses can easily hurt customer.
Poorly centered glasses can cause a variety of problems ranging from headaches and eye
problems, feeling tired etc. Glasses that are not anatomically correctly adjusted can fall and
push. The biggest problem is therefore certainly lack of the human and personal approach of
an optician or any other expert.
Correction with contact lenses on the Internet
Optical aids, that are mostly selled on the Internet are contact lenses and accessories.
In 2012 there was an increase of interest in contact lenses by 45%. People are buying contact
lenses on the internet for two main reasons. The first is a low price - contact lenses on the
internet are really cheaper because of the fact that a doctor recommended to their price must
be added the costs of examination and inspection. A second reason is the convenience of
shopping from home and speed of delivery. Contact lenses and solutions are already
considered finished product and thus when they are purchased over the Internet at low risk.
Purchases should therefore be safe and lenses should not in any way harm the eyesight.
However, this only applies if the customer before the purchase completes professional
application and all required examinations and if he knows on what type of contact lenses is
suitable for him. They must therefore know all relevant values,such as e.g. radius of curvature,
diameter and material of the contact lens. It is also important to know what type of solution
VII. CSKO 20. 10. 2016
147
to select. The customer then chooses a suitable type of contact lenses for him on the website.
While the purchase of glasses is required of him supplement his prescription values. After a
product is referred to as "inserted into the cart" he needs to add informations such as name
and address. The price of the course will be added postage, mostly after exceeding a certain
amount is usually free. Buying is very fast and comfortable because it can be done right from
home.
Purchasing contact lenses on the Internet is not as risky as buying prescription glasses.
According to experts, however, it has its disadvantages. The greatest is that when buying at
the optician´s a customer comes into contact with an expert. Just with one glance expert can
tell if the client does not suffer from any corneal pathology, which can be, for example,
excessive redness. The client can have this problem and may not even realize it. It's even been
shown that people who buys their contact lenses on the internet, are regularly forgetting to
go for their regular checkups. This increases the risk of many complications. The most common
problem is transferring lenses. In order to save money because people wear lenses longer than
recommended by the manufacturer. For their eyesight is very dangerous because of the
increased risk of infection. Many customers also think that if you do not wear lenses expands
and as the week, extending their wearing time of seven days. However, this is misleading
because it does not count the time during which the lens is in the eye. They must also think
about the daily exchange solution and periodic replacement lens case, which should be done
at least once in every three months. With this purchase, therefore there is no so much risk.
But only on condition that the customer really knows what he needs and visits an optician
regulary and will honestly care about his lenses.
Conclusion
What attracts clients the most when buying on the internet especially is the promise of
low prices. They forget, however, that when buying glasses at opticians there is the cost their
services credited. These services includes very personal and professional approach which is a
very important part of proper correction. Despite the fact that glasses purchased on the
Internet are not anatomically adapted and are not centered well. The customer therefore can
be easily hurt. When buying contact lenses on the internet the risk for the customer is not as
big as when buying glasses. Despite of that it is not recommended to buy them online. Contact
lens wearers usually forget about their regular checkups, which can lead to health problems.
In conclusion, it is important to say that personal and professional approach of optometrist or
optical expert is at the core of the correction. Also a client should be aware of this. A suitable
solution would be to alert the public of the risks of buying these optical aids online mainly
through communication with an expert.
Resources
Beneš, P. Nákupem čoček přes internet si můžete ohrozit zrak, řekl optometrista [online
24.2.2014]. http://ona.idnes.cz/on-line-rozhovor-kontaktni-cocky-dqn-
/zdravi.aspx?c=A141125_120251_zdravi_pet
VII. CSKO 20. 10. 2016
148
FEEDIT.CZ, 2013. Zájem o kontaktní čočky na internetu roste, lidé za ně v loňském roce utratili
téměř půl miliardy. [online 12.12.2014]. http://www.feedit.cz/wordpress/2013/04/03/zajem-
o-kontaktni-cocky-na-internetu-roste-lide-za-ne-v-lonskem-roce-utratili-temer-pul-miliardy/
OTTLENS, 2012. Nedisciplinovaných uživatelů kontaktních čoček přibývá. [online 12.12.2014].
http://www.ottlens.com/clanky/nedisciplinovanych-uzivatelu-kontaktnich-cocek-pribyva
VIDENI.CZ, 2010. Nakupování přes internet. Ano nebo ne? [online 9.12.2014].
http://www.videni.cz/produkty/47-nakupovani-pres-internet-ano-nebo-ne
VYHODNE-BRYLE, 2011. [online 9.12.2014]. http://www.vyhodne-bryle.cz/
VII. CSKO 20. 10. 2016
149
Přístroje potřebné pro vyšetření zrakového nervu při
diagnostice glaukomu, metodika vyšetření
Autor: Bc. Zuzana Gerbocová
Školitel: MUDr. Magdaléna Macurová
Diagnostika a sledovanie progresie glaukómu zahŕňa niekoľko diagnostických metód,
vrátane merania vnútroočného tlaku, subjektívneho hodnotenia terča ZN a testovania
zorného poľa. Tieto tradičné metódy hodnotenia glaukómu majú ale niekoľko kľúčových
obmedzení, ktoré dávajú priestor pre doplnkové vyšetrenia.
Vnútroočný tlak je hlavným rizikovým faktorom pre vznik glaukómového poškodenia,
jeho znižovaním sa snažíme zastaviť progresiu degeneratívnych zmien sietnice. Avšak, vysoká
individuálna variabilita a denné kolísanie VOT obmedzujú použitie tohto hodnotiaceho kritéria
pre diagnostiku ochorenia. Okrem toho, hodnoty vnútroočného tlaku nás neinformujú o tom,
či už došlo k poškodeniu, a ak áno, tak do akej miery.
Pozorovanie terča ZN pri glaukóme pri oftalmoskopickom vyšetrení vo veľkej miere
závisí na zručnostiach vyšetrujúceho, čo do istej miery ovplyvňuje funkčnosť tejto
diagnostickej metódy.
Počítačová statická perimetria je bežne používaným vyšetrením, ktoré je
pravdepodobne zlatý štandard pre hodnotenie glaukómovej neuropatie a pre sledovanie
progresie ochorenia. Aj keď je vyšetrenie citlivé na detekciu straty zorného poľa, má niekoľko
významných obmedzení, ktoré sa týkajú subjektívneho hodnotenia vyšetrovaného.
Vzhľadom k tomu, že glaukómové poškodenia sú nevratné, je nutné presne
diagnostikovať pacientov so skorými štrukturálnymi zmenami. Z tohto dôvodu je dôležité
presné a reprodukovateľné kvantitatívne hodnotenie zrakového nervu. Kvantitatívne
zobrazovacie technológie sú v tomto smere citlivejšie vo vyšetrení glaukómovej progresie v
porovnaní s klinickými kvalitatívnymi vyšetreniami.
V priebehu posledných dvoch desaťročí došlo k vývoju a uvedeniu do praxe niekoľkých
zobrazovacích technológií, ktoré sa vo veľkej miere využívajú na odhalenie skorých
glaukómových poškodení. Tento plagát sa zaoberá súčasnými zobrazovacími prístrojmi, ako
sú Heidelberský retinálny tomograf (HRT), Optický koherentný tomograf (OCT), Analyzátor
hrúbky sietnice (RTA) a Laserový skenovací polarimeter (GDx).
Glaukóm
Glaukóm je chronická neuropatia zrakového nervu, ktorého rizikovým faktorom je výška
VOT. Je to skupina očných ochorení, pri ktorých je poškodzovaný v dlhšom časovom horizonte
zrakový nerv, väčšinou z príčiny zvýšeného VOT. Z tohto poškodenia nervových vlákien
vyúsťujú typické zmeny zorného poľa.
VII. CSKO 20. 10. 2016
150
Existuje však i mnoho ďalších faktorov, ktoré môžu spôsobovať typické zmeny terča ZN,
a to i pri štatisticky normálnom vnútroočnom tlaku. Glaukóm je spojený s viacerými rizikovými
faktormi, ale vysoký VOT je z nich najvýznamnejší.
Přístroje potřebné pro vyšetření zrakového nervu při diagnostice glaukomu,
metodika vyšetření
Medzi prístroje potrebné pre vyšetrenie zrakového nervu pri diagnostike glaukómu patrí
Heidelberský retinálny tomograf (HRT), Optický koherentný tomograf (OCT), GDx Nerve Fiber
Analyzer (GDx Laserový skenovací polarimeter) a Retinal Thickness Analyzer (RTA - Analyzátor
hrúbky sietnice). Tieto moderné a objektívne zobrazovacie techniky pomáhajú v diagnostike
glaukómu a monitorovaniu jeho vývoja. Na tomto plagáte v skratke popíšem každý z nich,
hlavne ich princíp vyšetrenia zameraný na diagnostiku glaukómu.
Heidelberg Retina Tomograph – HRT
Heidelberský retinálny tomograf (HRT) je konfokálny laserový skenovací systém.
Vyvinutý nemeckou firmou Heidelberg Engineering patrí k zobrazovacím technikám a je jeden
z hlavných komerčne dostupných prístrojov, ktoré využívajú zobrazovací systém na vyšetrenie
oka. Ponúka tri moduly. Základný glaukómový modul kvantitatívne popisuje terč ZN
a posudzuje jeho zmeny v čase. Zameriava sa na detekciu glaukómových zmien v čase a ich
progresiu. Na tento modul sa zameriam. K ďalším modulom patrí rohovkový a makulárny.
GDx Nerve Fiber Analyzer
Skenovacia laserová polarimetria patrí medzi zobrazovacie technológie, ktoré využívajú
polarizačných vlastností sietnice na meranie hrúbky vrstvy RNFL. Je založená na princípe
dvojlomu (birefringencii). K hlavným dvojlomných vnútroočným tkanivám patrí rohovka, očná
šošovka a sietnica. V sietnici spôsobuje dvojlomnosť paralelné usporiadanie mikrotubulov vo
vrstve RNFL.
Polarizované svetlo laserového lúča, ktorý prechádza sietnicou je z hlbokých vrstiev
odrazené späť a vplyvom dvojlomnosti RNFL má určitý fázový posun. Veľkosť tohto fázového
posunu sa nazýva retardácia a je priamo úmerná hrúbke vrstvy RNFL. Pomocou detektoru sa
kvantifikuje hodnota retardácie, ktorá sa vypočítava pre každý bod sietnice.
Retinal Thickness Analyzer - RTA
Analyzátor hrúbky sietnice – RTA je viacúčelový prístroj, ktorý kombinuje digitálnu
fundus kameru, počítačové skenovanie pomocou štrbinovej lampy a samotný analyzátor
hrúbky sietnice. Poskytuje zobrazenie topografie sietnice a terča ZN s priamym zmeraním
hrúbky vrstvy nervových vlákien v peripapilárnej oblasti. Meria hrúbku sietnice aj v okolí
makuly, pretože pri glaukóme dochádza v tomto mieste tiež k stenčeniu kvôli úbytku
gangliových bb. Patrí k zobrazovacím technikám a slúži primárne k diagnostike a sledovaniu
pacientov s glaukómom, ale aj s diabetickou makulopatiou a makulárnymi degeneráciami
rôznej etiológie.
Optical Coherence Tomography – OCT
Optická koherentná tomografia - OCT (Carl Zeiss Meditec AG, Dublin, USA) je
vyšetrovacou zobrazovacou technológiou, ktorá umožňuje zobrazenie štruktúr sietnice, terča
VII. CSKO 20. 10. 2016
151
zrakového nervu a makuly s vysokým rozlíšením pri využití koherentných vlastností svetla.
Meria hrúbku vrstvy nervových vlákien sietnice na optickom princípe ultrasonografického Askenu.
Používa sa prevažne na vyšetrovanie a diagnostikovanie pacientov s glaukómom.
Rozdiel medzi FD-OCT a TD-OCT spočíva v základoch využívanej technológie. Tieto obe
OCT technológie vychádzajú z merania hrúbky štruktúr tkaniva, ktoré vychádza z princípu
časových oneskorení lúča, ktorý sa vracia z rôznych hĺbok oka.
Klasický OCT s Time-Domain systémom využíva vláknovú optiku Michaelsonovho
interferometru k zmeraniu časového rozdielu v odraze. Laserový lúč vychádza
zo superluminiscenčnej diódy, vstupuje do optického vlákna, ktorý ho pomocou deliča zväzku
rozdelí na 2 samostatné dráhy lúčov. Jeden lúč mieri k referenčnému zrkadlu (kontrolný lúč)
a druhý miericez pupilu do oka, kde sa odráža od jednotlivých vrstiev sietnice. Reflexie z oboch
lúčov sú potom zrekombinované a výsledná interferencia oboch lúčov sa detekuje
a digitalizuje pre počítačové spracovanie. Posudzuje sa časové oneskorenie lúča, ktorý sa
odráža od štruktúr tkanív v oku voči lúču vychádzajúcemu zo zdroja. Zároveň dochádza
k posunu referenčného zrkadla, ku ktorému mieri kontrolný lúč v závislosti na hĺbke
skenovanej štruktúry čím vzniká jeden A-sken, ktorý podáva informáciu o hĺbke v určitej
oblasti. Každý posun referenčného zrkadla vedie k vytvoreniu A-skenu.
Klasický TD-OCT má však svoje limity, ktoré prekonala FD-OCT. Pri TD-OCT sme boli
obmedzení rýchlosťou mechanického pohybu referenčného zrkadla, ktorý bol potrebný
k zachyteniu A-skenu. OCT s Fourier-Domain technológiou má referenčné zrkadlo pevne
upevnené. Rozdiel je v tom, že interferencia lúčov sa pomocou difrakčnej mriežky rozkladá na
spektrum. Potom sú pomocou Fourierovej analýzy jednotlivé vlnové dĺžky spracované
k vytvoreniu A-skenu. Vďaka stacionárnej polohe referenčného zrkadla je celý proces oveľa
rýchlejší ako pri TD-OCT, taktiež tým získame viac skenov za sekundu a skráti sa aj doba
vyšetrovania.
Zistená latencia odrazu lúčov sa následne farebne kóduje a z A-skenov sa vytvorí 2D
obraz prierezom tkanív. Reflektivita tkanív sa na ňom farebne odlišuje, vysokoreflektívne
tkanivá sú v červenej až bielej farbe, s nízkou reflektivitou v modrej až čiernej farbe. Žltozelene
sú zobrazené tkanivá s priemernou reflektivitou. K vysokoreflektivným tkanivám patrí RNFL,
pigmentový epitel sietnice a choriocapillaris cievnatky. Vrstva fotoreceptorov, chorioidea
a ohraničené ložiská tekutiny majú nízku reflektivitu. Označenie terča sa deje automaticky, nie
je nutné vyznačenie kontúrnej krivky ako v predchádzajúcich prístrojoch. Taktiež OCT
umožňuje skenovať 3 osobité očné štruktúry a to peripapilárnu vrstvu nervových vlákien,
makulu a terč zrakového nervu.
Zdroje
Kuchynka, P. Oční lékařství. Praha: Grada, 2007. ISBN 978-80-247-1163-8.
Kraus, H. Kompendium očního lékařství. Praha: Grada, 1997. ISBN 80-7169-079-1.
Stamper, R. L., Lieberman M. F., V. Drake, M. V. Becker-Shaffer's diagnosis and therapy of the
glaucomas. 8th ed. Edinburgh: Mosby/Elsevier, c2009. ISBN 978-0-323-02394-8.
VII. CSKO 20. 10. 2016
152
Rozsíval, P. Trendy soudobé oftalmologie. Praha: Galén, 2012. ISBN 978-80-7262-818-6.
Výborný, P., Rozsíval, P. Glaukom: vybrané kapitoly. Hradec Králové: Nucleus HK, 2008.
Oftalmologie. ISBN 978-80-87009-35-2.
Všetky použité zdroje sú uvedené v kapitole Zoznam literatúry a internetových zdrojov na
konci bakalárskej práce, dostupné na webovej stránke:
https://is.muni.cz/auth/th/411119/lf_b/
VII. CSKO 20. 10. 2016
153
Devices needed for examination of the optic nerve head in
glaucoma diagnostics, methodology of examination
Author: Bc. Zuzana Gerbocová
Supervisor: MUDr. Magdaléna Macurová
Diagnosis and monitoring of glaucoma progression includes a number of diagnostic
methods, including the measurement of intraocular pressure, subjective assessment of the
ONH and visual field testing. These traditional methods for assessing glaucoma have some
limitations that give space for additional examination.
Intraocular pressure is a major risk factor for glaucoma damage, trying to reduce is way
to stop the progression of degenerative changes in the retina. However, the high individual
variability and IOP daily fluctuation limit the use of the evaluation criteria for the diagnosis of
disease. Moreover, IOP values inform us whether damage has occurred, and if so, to what
extent.
Observing the ONH in glaucoma at ophthalmoscopic examinations will largely depend
on the skills of examiner, which to some extent affect the functionality of this diagnostic
method.
Computer static perimetry is a widespread examination, which is probably the gold
standard for evaluation of glaucomatous neuropathy and to monitor disease progression.
Although the testing is sensitive to the detection of the loss of visual field, it has significant
limitations related to subjective evaluation of investigated.
In view of the fact that glaucoma is irreversible damage, it is necessary to accurately
diagnose patients with early structural changes. Therefore, it is important to accurate and
reproducible quantitative evaluation of the optic nerve. Quantitative imaging technology are
more sensitive in screening glaucoma progression compared with clinical qualitative
examination.
Over the past two decades have been developed and put into practice a number of
imaging technologies that are widely used to detect early damage of glaucoma. This poster
presents the current imaging devices such as Heidelberg retinal tomography (HRT), Optical
coherence tomography (OCT), Retinal thickness analyzer (RTA) and Scanning laser polarimeter
(GDx).
Glaucoma
Glaucoma is a chronic optic neuropathy, the risk factor is the hight of IOP. It is a group
of eye diseases in which in the longer term is the optic nerve harmed, most of the causes of
increased IOP. Damage nerve fibers are resulting in characteristic visual field changes.
VII. CSKO 20. 10. 2016
154
However, there are also many other factors that can cause characteristic changes in the
ONH, including the statistically normal intraocular pressure. Glaucoma is associated with
several risk factors, but the high IOP is one of the most important.
Devices needed for examination of the optic nerve head in glaucoma
diagnostics, methodology of examination
The devices necessary for the examination of the optic nerve in glaucoma diagnosis
include Heidelberg retinal tomography (HRT), Optical coherence tomography (OCT), GDx
Nerve Fiber Analyzer (GDx scanning laser polarimeter) and Retinal Thickness Analyzer (RTA).
These modern and objective imaging techniques help in the diagnosis of glaucoma and
monitor its development. On this poster is short description of each of them, especially the
principle of examination for glaucoma diagnosis.
Heidelberg retina tomography – HRT
Heidelberg retinal tomography (HRT) is a laser scanning confocal system. Developed by
the German company Heidelberg Engineering is one of the imaging techniques and it is one of
the major commercially available devices which use an imaging system for the examination of
the eye. It offers three modules. The basic module of glaucomatous ONH quantitatively
describes and assesses its changes over time. It focuses on the detection of glaucoma changes
over time and their progress. Additional modules include corneal and macular.
GDx Nerve Fiber Analyzer
Scanning Laser Polarimetry is among imaging technologies that use polarization
character of the retinal layer for thickness measuring of RNFL. It is based on the principle of
birefringence. The main birefringent intraocular tissues include cornea, eye lens and retina.
Cause of birefrigence of the retina is microtubule configuration in a layer RNFL.
Polarized light of the laser beam that passes through the retina is reflected back from
deep layers and because of the birefringence of the RNFL has a phase shift. The size of this
phase difference is called a retardation and it is proportional to the layer thickness of the RNFL.
The detector is used to quantify the value of retardation, which is calculated for each point of
the retina.
Retinal Thickness Analyzer – RTA
Retinal thickness analyzer - RTA is a multipurpose device that combines digital fundus
camera, computer scanning with slit lamp and retinal thickness analyzer itself. It provides the
topography of the retina and the ONH with direct measurement of the thickness of the layer
of nerve fibers in the peripapillary area. Measures the thickness of the retina around the
macula, glaucoma occurs in this place also because of the thinning of the loss of ganglion cells.
It is one of the imaging techniques primarily used for diagnosis and monitoring of glaucoma
patients, but also with diabetic maculopathy and macular degeneration different etiology.
Optical Coherence Tomography – OCT
Optical coherence tomography - OCT (Carl Zeiss Meditec AG, Dublin, USA) is an
investigative imaging technology that allows you to view the structure of the retina, optic
nerve and macula with high resolution using coherent properties of light. Measures the
VII. CSKO 20. 10. 2016
155
thickness of the retinal nerve fiber layer on the optical principle of an ultrasound A-scan. It is
used primarily for the detection and diagnosis of patients with glaucoma.
The difference between the FD-OCT and TD-OCT is based on the use of technology.
These two OCT technology is based on measurements of tissue structure which is based on
the principle of time delay beam, coming back from different depths of the eye.
Classic OCT with Time-Domain system uses fiber optics of Michaelson´s interferometer
to measure time difference in reflection. The laser beam is based on a superluminescent
diode, enters the fiber optic link, usage the beamsplitters split into two separate beam paths.
One ray heads to a reference mirror (beam control) and a second ray heads through the pupil
of the eye, which is reflected by the different layers of the retina. Reflections of the two beams
are then combinated and the resulting interference of the two beams is detected and
digitalized for computer processing. Computer is assessing the time delay betwen beam that
is reflected from the tissue structure in the eye to the beam coming from the source. At the
same time the displacement of the reference mirror is occuring, the beam is on the way
towards the mirror where depending on the scanning depth structure is an A-scan formed,
which gives an indication of the depth in a particular area. Any shift in the reference mirror
leads to the creation of A-scan.
Classic TD-OCT has its limits, however it was overcomed by the FD-OCT. When TD-OCT
we have speed limits of the mechanical movement of the reference mirror, which was needed
to capture A-scan. OCT with Fourier-Domain technology has a reference mirror firmly
attached. The difference is that the interference of the beams is divided on the spectrum using
the diffraction grating. Then the Fourier analysis of individual wavelengths processed to create
A-scan. Due to the stationary position of the reference mirror, the whole process is much
faster than in the TD-OCT, also allow more scans per second and reduces the time of the
investigation.
Detected latency reflection beam is then color-coded and from the A-scans is created a
2D image section tissues. Reflectivity of the tissues differs in color, highly reflective tissues are
in red and white, with a low reflectivity in blue and black. Yellow-green tissues are shown with
average reflectivity. The highly reflective tissues include RNFL, retinal pigment epithelium and
choriocapillaris of the choroid. Layer of the photoreceptors, chorioidea have low reflectivity.
Target marking is done automatically, it is not necessary marking contour curves than in
previous devices. OCT also allows you to scan 3 eye structure and the peripapillary nerve fiber
layer, macula and optic disc.
Resources
Kuchynka, P. Oční lékařství. Praha: Grada, 2007. ISBN 978-80-247-1163-8.
Kraus, H. Kompendium očního lékařství. Praha: Grada, 1997. ISBN 80-7169-079-1.
Stamper, R. L., Lieberman M. F., V. Drake, M. V. Becker-Shaffer's diagnosis and therapy of the
glaucomas. 8th ed. Edinburgh: Mosby/Elsevier, c2009. ISBN 978-0-323-02394-8.
Rozsíval, P. Trendy soudobé oftalmologie. Praha: Galén, 2012. ISBN 978-80-7262-818-6.
VII. CSKO 20. 10. 2016
156
Výborný, P., Rozsíval, P. Glaukom: vybrané kapitoly. Hradec Králové: Nucleus HK, 2008.
Oftalmologie. ISBN 978-80-87009-35-2.
All the resources are available at: https://is.muni.cz/auth/th/411119/lf_b/ referred to in
Chapter Bibliography and Internet resources at the end of this thesis.
VII. CSKO 20. 10. 2016
157
Metodika stanovení hodnoty optimální akomodační šíře,
ověření závislosti naměřených hodnot na pracovní
vzdálenosti
Autor: Bc. Andrea Hanušová
Školitel: Mgr. Radek Anderle, Ph.D.
Úvod
Akomodaci lze zjednodušeně popsat jako schopnost adaptace optické mohutnosti
systému oka tak, aby bylo možné předměty nacházející se v různých vzdálenostech před okem
vidět ostře, a tak je tedy nutné pozorovat její změny, aby byl zajištěn co největší komfort
vidění. Akomodace je ovlivněna dvěma základními faktory, a to schopností čočky přizpůsobit
svůj tvar (fyzikální akomodace) a také silou ciliárního svalu, která je potřebná ke změně
refrakčního stavu oka (fyziologická akomodace). Akomodaci také provázejí dva další jevy, jako
jsou konvergence a zúžení zornice. Detailní popis obou těchto jevů lze nalézt v literatuře, např.
v [1].
Akomodační interval
Akomodační interval, resp. rozsah akomodační schopnosti čočky, je nezbytné určit pro
výpočet kýžené hodnoty akomodační šíře v [D], která je definována jako převrácená hodnota
jeho krajních bodů. Tyto hraniční body jsou označovány jako daleký a blízký bod, a jejich
definice tedy nutná pro správné pochopení akomodace a stanovení její šíře.
Blízký a daleký bod
Nejbližší bod, na který je oko schopné zaostřit při akomodaci, se nazývá blízký bod P.
Jedná se tedy o bod, který je při maximálním akomodačním úsilí ostře zobrazen na sítnici oka.
Pro účely výpočtu akomodační šíře je nezbytné určit jeho vzdálenost αP [m] od hlavního
předmětového bodu oka H. V důsledku postupné ztráty elasticity čočky se zvyšujícím se věkem
se vzdálenost blízkého bodu od hlavního předmětového bodu oka pohybuje přibližně od
hodnoty 0,0075 m (pro osoby mladší než 10 let) až po hodnotu vzdálenosti dalekého bodu.
Naopak daleký bod R je definován jako nejvzdálenější bod, který je ostře zobrazen na
sítnici oka v relaxovaném stavu, tedy při minimální akomodaci. Jako v předchozím případě je
jeho vzdálenost αR [m] definována jako rozdíl jeho polohy vůči hlavnímu předmětovému bodu
oka H. Poloha promítnutí vzdáleného bodu R vůči sítnici je závislá na aktuální refrakční vadě.
Pro emetropické oko je R promítnut přímo na sítnici, u oka myopického před sítnici, a u
hypermetropického oka se nachází za sítnici. Samozřejmě platí, že s vyšší úrovní refrakční vady
se vzdálenost mezi R a sítnicí zvyšuje.
Teorie akomodace
Existují čtyři základní teorie, které se věnují akomodaci z teoretického hlediska. První,
Helmholtzova, teorie zakládá akomodaci na tzv. vnějším akomodačním mechanismu, který
VII. CSKO 20. 10. 2016
158
způsobuje aktivní akomodaci oka za použití stahů cirkulárních vláken Müllerova (ciliárního)
svalu a uvolňování vláken závěsného aparátu čočky, kdežto pasivní akomodace je způsobena
zakřivením přední plochy čočky. Gullstrandova teorie akomodace naopak definuje tzv. vnitřní
akomodační mechanismus, který využívá přesunu části čočkových hmot o vyšším indexu do
optické osy k akomodaci oka.
Schacharova a Tscherningova teorie akomodace je založena na ekvatoriální části zonuly,
která se upíná do nejpřednějších částí ciliárního svalu, a na deformaci čočky způsobenou
sklivcem. Poslední, Colemanova teorie akomodace uvádí, že diafragma je tvořena čočkou,
závěsným aparátem a přední částí sklivce. U Colemanovy teorie způsobuje ciliární sval tlakový
gradient mezi předním sklivcem a přední komorou při konstrikci, což způsobuje, že tlak sklivce
směrem na čočkové pouzdro způsobuje vyklenutí přední plochy čočky do přední komory.
Velmi zajímavé výsledky v oblasti teorie akomodace jsou uvedeny v [2], kde je vyvracen
vliv tlaku sklivce během akomodace neboť změna polohy předního a zadního pólu čočky je
téměř stejná, což vede k potvrzení Helmholtzovy kapsulární teorie. Další moderní studie
popisuje teorii akomodace na základě změny biometrie oka [3], kde je opět potvrzena
Helmholtzova teorie, neboť nebyly zjištěny žádné významné změny parametrů oka (axiální
délky, atd.) během akomodace. Tuhost čočky je zde uvedena jako pravděpodobný hlavní vliv
na počínající presbyopii.
Poruchy akomodace
Poruchy, které ovlivňují správnou činnost akomodace, můžeme klasifikovat jako
fyziologické nebo patologické. Patologické poruchy jsou způsobeny jinou než oční příčinou a
nejčastěji mezi ně řadíme exces akomodace, insuficienci akomodace, spasmus a obrnu
akomodace. Dalšími faktory, které ovlivňují kvalitu a schopnost akomodace jsou např.
glaukom, zánět duhovky atd. Další poruchy akomodace a jejich detailní popis lze nalézt např.
v [4].
Presbyopie
Mezi nevýznamnější fyziologické poruchy akomodace se řadí presbyopie (stařecká
vetchozrakost), která je definována jako pokles akomodační šíře s přibývajícím věkem. Tento
jev je způsobený dvěma faktory. Prvním významným faktorem způsobující presbyopii je
snižování elasticity a plasticity čočkové hmoty, což je nejčastěji uváděná příčina vzniku
presbyopie. Druhým faktorem je snížená schopnost kontrakce a dilatace svalových vláken
Müllerového svalu, kdy čočka není schopna zaujmout vyklenutý tvar [5].
Vlastnosti presbyopie, její symptomy, vliv na jednotlivé typy refrakčních vad atd. jsou
popsány detailněji např. v [6].
Metodologie
V rámci vlastního výzkumu byla provedená měření akomodační šíře orientována pouze
na skupinu presbyopů, aby byly získány diference mezi jednotlivými hodnotami akomodační
šíře v závislosti na věku uvnitř této skupiny. Akomodační šíře byla změřena dvěma metodami
a to konkrétně metodou push-down (PD) a metodou push-up (PU) k tomu, aby bylo ověřeno,
VII. CSKO 20. 10. 2016
159
zda-li stačí stanovit akomodační rezervu o velikosti 1/2 nebo 1/3 akomodační šíře za pomoci
adice.
Jak již bylo zmíněno, dosavadní měření byla provedena na skupině presbyopů ve věku
41 až 60 let. Celkem bylo změřeno 15 osob, z čehož bylo 9 žen a 6 mužů. Žádná změřená osoba
netrpěla jakoukoliv oční patologií, a její minimální dosažený visus měl hodnotu 1.
Jednotlivá měření probíhala následovně: nejprve byla stanovena objektivní refrakce
pomocí autorefraktometru a poté byla změřena subjektivní refrakce. Následně byla
individuálně metrem změřena pracovní (čtecí) vzdálenost, na kterou byli jednotliví účastníci
zvyklí.
Dále byla změřena pro každý subjekt akomodační šíře za pomoci metod push-up a
push-down nejprve pro každé oko individuálně a poté binokulárně, aby byla ověřena
minimální diference mezi jednotlivými oky. Každé měření proběhlo třikrát, hodnoty použité v
dalším zpracování výsledků jsou průměrem hodnot získaných pro binokulární měření
akomodační šíře. Proces PU a PD metod je detailněji popsán v literatuře, např. v [7].
Za pomoci naměřených hodnot akomodační šíře byla vypočtena adice, která je
definována následujícím vztahem:
𝐴𝐷𝐷 = −
1
ℎ𝑝𝑏
− 𝛽 ∙ 𝐴Š
kde ADD je adice, hpb je hlavní pracovní bod v [m], β je koeficient využití akomodační
šíře (2/3 nebo 1/2), a AŠ je velikost akomodační šíře v [D].
Poté bylo experimentálně zjištěno, zda-li se jednotlivým subjektům lépe čte (subjektivně
vice vyhovuje) s adicí 1/3 nebo 1/2 akomodační šíře v rezervě, aby byla prakticky potvrzena či
vyvrácena teoreticky vypočtená hodnota ADD. Na základě použitých metod byly stanoveny
následující hypotézy:
H1: Naměřené hodnoty akomodační šíře budou větší pro metodu PU.
H2: Alespoň 60% část vzorku bude subjektivně preferovat 1/2 akomodační šíře v rezervě.
Experimentální výsledky
Tato sekce popisuje experimentální výsledky, které byly získány měřením osob z výše
uvedené databáze.
Graf 1: Dosažené výsledky metodou PU
0
1
2
3
4
5
41 46 48 50 51 52 53 54 56 58 60
PrůměrnáAŠ[D]
Věk [roky]
OD_PU
OS_PU
BINO_PU
VII. CSKO 20. 10. 2016
160
První graf ilustruje získané velikosti akomodační šíře metodou PU pro pravé (OD_PU),
levé (OS_PU) a binokulárně (BINO_PU) v závislosti na věku. Z dosažených výsledků touto
metodou vyplývá, že binokulární akomodační šíře je skutečně vyšší než pro každé oko zvlášť,
a má klesající tendenci s rostoucím věkem. Ne zcela ideální klesající průběh naměřených
hodnot je způsoben malým počtem vzorků v jednotlivých věkových kategoriích, což přináší
riziko, že budou zobrazeny výsledky pro krajní intervaly předpokládaného normálního
rozložení.
Graf 2: Dosažené výsledky metodou PD
Druhý graf představuje experimentálně získané velikosti akomodační šíře pro metodu
PD a je ekvivalentem prvního grafu. Naměřená závislost má stejnou tendenci jako pro metodu
PU, avšak s tím rozdílem, že jednotlivé hodnoty jsou přibližně nižší o 0,75 D. Tento fakt je
znázorněn pro binokulární akomodační šíři na grafu č. 3, kde jsou patrné vyšší naměřené
hodnoty metodou PU.
Graf 3: Srovnání výsledků dosažených metodou PU a PD
Následující tabulka uádí naměřené hodnoty hpb, vypočtené hodnoty ADD, subjektivně
preferovanou akomodační rezervu a další údaje jednotlivých naměřených subjektů
z databáze. Z dosažených výsledků je patrné, že žádná hodnota možné akomodační rezervy
není zcela značně preferovaná. Tudíž je nezbytné rozšířit databázi o větší počet vzorků.
0
1
2
3
4
41 46 48 50 51 52 53 54 56 58 60
PrůměrnáAŠ[D]
Věk [roky]
OD_PD
OS_PD
BINO_PD
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
41 46 48 50 51 52 53 54 56 58 60
PrůměrnáAŠ[D]
Věk [roky]
BINO_PU
BINO_PD
VII. CSKO 20. 10. 2016
161
Subjekt Pohlaví Věk hpb [cm] ADD [D] Ak. rezerva [-]
1 Muž 56 33,5 2,25 1/3
2 Muž 60 39 2,5 1/2
3 Žena 53 43 1 1/3
4 Žena 54 44 2 1/3
5 Muž 58 40 1,75 1/3
6 Muž 41 38 0,75 1/2
7 Žena 52 33 2 1/3
8 Žena 58 27 2,25 1/2
9 Muž 46 44 1 1/2
10 Muž 58 54 1,75 1/2
11 Žena 53 36 2 1/3
12 Žena 50 42 2 1/2
13 Žena 51 40 1,75 1/2
14 Žena 46 42 1 1/2
15 Žena 48 37 1,75 1/3
Tabulka 1: Naměřené hodnoty
Závěr
Tímto příspěvkem byla popsána možná metodologie stanovení akomodační šíře. Také
byly za pomocí provedených měření získány údaje pro 15 presbyopů, u kterých byla dále
vypočtena adice a z ní vyplývající subjektivně lépe snášená akomodační rezerva. Provedeným
měřením byla prozatímně potvrzena hypotéza, že větší akomodační šíře je naměřena
metodou PU, kdežto hypotézu týkající se akomodačních rezerv nelze nyní vyvrátit či potvrdit.
Pro další kroky a stanovení příslušných výsledků je nutné databázi značně rozšířit.
Zdroje
[1] Kuchynka, P. Oční lékařství. 1. vydání. Praha: Grada Publishing a.s., 2007.
[2] Farouk, M. M. OCT Reveals New Insights into the Accommodation Mechanism. Journal of
Ophthalmology, vol. 2015, 2015.
[3] Laughton, D. S. A longitudinal study of accommodation changes in biometry during
incipient presbyopia. Ophthalmic and Physiological Optics, vol. 36, no. 1, 2016.
[4] Autrata, J., Černá, J. Nauka o zraku. 1. Brno: NCO NZO, 2006.
[5] Anton, M. Refrakční vady a jejich vyšetřovací metody. Brno: Institut pro další vzdělávání
pracovníků ve zdravotnictví, 1993.
[6] Eferon, N. Optometry A-Z. Oxford: Butterworth – Heinemann, 2007.
[7] K. Koslowe, K., Glassman T., Tzanani-Levi, C., Shneor, E. Accommodative Amplitude
Determination “Pull-away“ versus „Push-up Method“. Optometry & Vision Development, vol.
41, no. 1, 2010.
VII. CSKO 20. 10. 2016
162
Methodology of Setting the Optimal Accommodation
Amplitude, the Verification of Measured Values Depending
on Working Distance
Author: Bc. Andrea Hanušová
Supervisor: Mgr. Radek Anderle, Ph.D.
Introduction
Accommodation can be simply described as the capability of eye optical power to see
the objects located in different distances in front of eye sharply, so it is necessary to observed
its changes to provide as the highest visual comfort as possible. The accommodation is
influenced by two factors- the shape adaptation of lens (physical accommodation) and the
strength of ciliary muscle needed for the change of refraction state (physiological
accommodation). Also two accompanying effects exit with accommodation- convergence and
narrowing the pupil. Detail description of both effects can be found e.g. in [1].
Accommodation range
The accommodation range (the range of lens’ accommodation capability) is necessary
to be set for further accommodation amplitude calculation defined as the reciprocal value of
its boundary points. These boundaries are called near and far point and their definition is
necessary for the correct understanding of accommodation and setting its amplitude.
Near and Far point
The nearest point which can be focused by eye at accommodation state is called as the
near point P. Obviously, this point is sharply projected at retina while accommodation level
occurs its maximum. Its distance αP [m] from the main object point of eye H has to be
measured for further accommodation amplitude calculation. In the case of losing the lens
elasticity depending on age, its distance αP converges from approx. 0,0075 m (age lower than
10 years) to the distance of far point.
The far point R is defined as the most far point which is sharply projected at retina for
relaxed eye (minimal accommodation). As in previous case, its distance αR [m] is defined from
the main object point of eye H and its position with respect to retina is dependent on
refraction defect. For myopic eye, the far point is projected in front of the retina, and for
hypermetropic eye it is projected behind the retina. The distance between R and retina grows
with increasing refractive defect.
Theory of accommodation
Four fundamental theories of accommodation theory exist. First, the Helmholtz theory
is based on the so-called external accommodating mechanism which causes the active eye
accommodation using contractions of circular Müller (ciliary) muscle fibers and releases the
lens suspension apparatus, while passive accommodation is caused by the curvature of the
VII. CSKO 20. 10. 2016
163
anterior surface of the lens. Gullstrand's theory of accommodation conversely defines socalled
inner accommodative mechanism which utilizes the moving parts of lenticular masses
with a higher index of the optical axis of the eye accommodation.
Schachar’s and Tscherning’s theories of accommodation are based on the equatorial
part of the zonule clamped in the foremost part of the ciliary muscle and the lens deformation
caused by vitreous. The last, Coleman's theory of accommodation states that the diaphragm
is formed by the lens apparatus, and coupling the front of the vitreous humor. Coleman’s
theory of accommodation states that the ciliary muscle causes a pressure gradient between
the anterior vitreous and anterior chamber at a constriction, which causes the pressure of the
vitreous body in the direction of the lens capsule caused by the curvature of the front surface
of the lens into the anterior chamber.
Interesting results in the theory of accommodation are described in [2], where the
influence of vitreous pressure during the accommodative change of position since the anterior
and posterior pole of the lens is almost the same, which leads to confirm the capsular
Helmholtz theory, is mentioned. Another study describing the theory of modern
accommodation based on the changes in eye biometrics [3], which leads again to the
confirmation of Helmholtz theory, because there were no significant changes in the
parameters of the eye (axial length, etc.) during accommodation. The rigidity of the lens is
indicated as a likely major influence on incipient presbyopia.
Accommodation defects
Defects affecting the correct functionality of the accommodation can be classified as
physiological or pathological. Pathological disorders are caused by other impact not caused by
eye and the most often among their midst excess of accommodation, accommodative spasm
and paralysis of accommodation. Other factors that affect the quality and ability of
accommodation are e.g. glaucoma, iritis etc. Further accommodation defects and their detail
description can be found e.g. in [4].
Presbyopia
Among the most significant physiological disorders of accommodation include
presbyopia (senile presbyopia),which is defined as a decrease in amplitude of accommodation
with age. This phenomenon is caused by two factors. The first important factor causing
presbyopia is the reduction of elasticity and plasticity of lens material, which is the most
frequent mentioned cause of presbyopia. The second factor is the reduced ability of
contraction and expansion of the fibers of Müller’s muscle when the lens is not able to reshape
itself into a curved shape [5].
Properties of presbyopia, the symptoms, the effect on individual types of refractive
errors etc. are described in detail e.g. in [6].
Methodology
In the case of our own research has been carried out, the measuring of accommodative
amplitude oriented only to a group presbyopics to obtain differences between the values
of amplitude of accommodation according to the age within that group.
VII. CSKO 20. 10. 2016
164
Accommodative amplitude was measured by two methods, namely by the push-down (PD)
and by the push-up (PU) to verify if it is sufficient to determine if the accommodative reserve
size 1/2 or 1/3 of the amplitude of accommodation is enough with respect to addition.
As it has been already mentioned, the current measurement was conducted on the
group of presbyopics aged 41-60 years. Totally were measured 15 persons (9 women and 6
men). No one measured person does not suffer by any ocular pathology, and its minimum
achieved visus reached the value of 1.
Individual measurements were as follows: firstly, it was determined the objective
refraction by autorefractometer and then the subjective refraction was measured. The
working (reading) distance at which they were accustomed to individual participants was
measured by a ruler.
It was also measured, for each subject, the amplitude of accommodation by using the
push-up and push down for each individual eye firstly and then binocularly for verifying the
minimal difference between eyes. Each measurement was performed out three times, the
values used in the further processing are averaged values obtained for binocular measuring
amplitude of accommodation. The process of PU and PD methods is more described in detail
in the literature, e.g., in [7].
By measured values, the amplitude of accommodation of addition was calculated as
follows:
𝐴𝐷𝐷 = −
1
ℎ𝑝𝑏
− 𝛽 ∙ 𝐴Š
where ADD is addition, hpb stands for the main working point [m], β is the coefficient of
the usage of accommodation amplitude (2/3 or 1/2), and AŠ is the size of accommodation
width [D].
Then, it was experimentally determined whether the individual subjects read
(subjectively more comfortable) easier with the addition of 1/3 or 1/2 of amplitude of
accommodation in reserve to confirm or disprove theoretically calculated ADD value. On used
methods, the following hypotheses were stayed:
H1: Measured values of accommodation amplitude are higher for PU method.
H2: At least the 60% of used database will prefer 1/2 of accommodation amplitude in
reserve.
Experimental results
This section describes experimental results obtained by measurement of persons from
the above database.
VII. CSKO 20. 10. 2016
165
Graph 1:
Graph 1 illustrates received values of accommodation amplitude by PU for right eye
(OD_PU), left eye (OS_PU) and binocular (BINO_PU) depending on age. Results achieved by
this method show that binocular amplitude of accommodation is actually higher than for each
eye individually, and it decrease with increasing age. The decreasing trend of measured values
is not ideal, because of the small number of samples in each category, which carries the risk
of displaying the values for the extreme ranges of expected normal distribution.
Graph 2:
Graph 2 resents experimentally obtained values of accommodation amplitude for the
PD and it is equivalent to the first graph. The measured dependence has the same trend as for
the method PU, but with the difference that the individual values are lower by approx. 0,75
D. This fact is illustrated for binocular accommodative range on graph 3, where higher values
measured by the PU are obvious.
0
1
2
3
4
5
41 46 48 50 51 52 53 54 56 58 60
PrůměrnáAŠ[D]
Věk [roky]
OD_PU
OS_PU
BINO_PU
0
1
2
3
4
41 46 48 50 51 52 53 54 56 58 60
PrůměrnáAŠ[D]
Věk [roky]
OD_PD
OS_PD
BINO_PD
VII. CSKO 20. 10. 2016
166
Graph 3:
Chart 1 lists the measured values of hpb, calculated ADD values, subjectively preferred
reserve in accommodation and other individual measured data for each subject from the
database. Obtained results show, that no value of accommodative reserve is not completely
preferred in general. Therefore, it is necessary to expand the database further subjects.
Subjekt Pohlaví Věk hpb [cm] ADD [D] Ak. rezerva [-]
1 Muž 56 33,5 2,25 1/3
2 Muž 60 39 2,5 1/2
3 Žena 53 43 1 1/3
4 Žena 54 44 2 1/3
5 Muž 58 40 1,75 1/3
6 Muž 41 38 0,75 1/2
7 Žena 52 33 2 1/3
8 Žena 58 27 2,25 1/2
9 Muž 46 44 1 1/2
10 Muž 58 54 1,75 1/2
11 Žena 53 36 2 1/3
12 Žena 50 42 2 1/2
13 Žena 51 40 1,75 1/2
14 Žena 46 42 1 1/2
15 Žena 48 37 1,75 1/3
Chart 1:
Conclusion
In this paper, the methodology of determining the accommodation amplitude was
described. The data were obtained for 15 presbyopics, addition values and subjectively better
tolerated accommodative reserve were also achieved for each individual subject. By
performed measurements, the hypothesis that the more accommodative amplitude is
measured by PU can be provisionally confirmed, while the hypothesis concerning the
accommodative reserve cannot be currently rejected or confirmed. In future, it is necessary
to expand the database for achieving more appropriate results.
0
1
2
3
4
5
41 46 48 50 51 52 53 54 56 58 60
PrůměrnáAŠ[D]
Věk [roky]
BINO_PU
BINO_PD
VII. CSKO 20. 10. 2016
167
References
[1] Kuchynka, P. Oční lékařství. 1. vydání. Praha: Grada Publishing a.s., 2007.
[2] Farouk, M. M. OCT Reveals New Insights into the Accommodation Mechanism. Journal of
Ophthalmology, vol. 2015, 2015.
[3] Laughton, D. S. A longitudinal study of accommodation changes in biometry during
incipient presbyopia. Ophthalmic and Physiological Optics, vol. 36, no. 1, 2016.
[4] Autrata, R., Černá, J. Nauka o zraku. 1. Brno: NCO NZO, 2006.
[5] Anton, M. Refrakční vady a jejich vyšetřovací metody. Brno: Institut pro další vzdělávání
pracovníků ve zdravotnictví, 1993.
[6] Eferon, N. Optometry A-Z. Oxford: Butterworth – Heinemann, 2007.
[7] K. Koslowe, K., Glassman T., Tzanani-Levi, C., Shneor, E. Accommodative Amplitude
Determination “Pull-away“ versus „Push-up Method“. Optometry & Vision Development, vol.
41, no. 1, 2010.
VII. CSKO 20. 10. 2016
168
Dodržování hygieny a návyky nositelů měkkých kontaktních
čoček
Autor: Bc. Barbora Hráčková, Bc. Marie Kodetová
Školitel: Mgr. Pavel Beneš, Ph.D.
Úvod
V současné době lidé řeší svou refrakční vadu mnohem častěji než tomu tak bylo dříve.
Řada z nás v práci využívá digitálních technologií, které vyžadují zcela rozdílné požadavky na
vidění než tomu tak bylo při práci s tištěným textem. Dalším důvodem také je nezadržitelné
stárnutí populace. Evolučně bylo naše oko naprogramováno na stáří přibližně čtyřiceti let.
Dnes se však není problém dožít dvojnásobně delšího věku. Proto se dnes setkáváme s větším
počtem lidí, které trápí stařecká vetchozrakost.
Lidé si mohou vybrat z několika způsobů, jak svoji refrakční vadu řešit. Možností volby
je brýlová korekce, aplikace kontaktních čoček či podstoupení zákroku refrakční chirurgie. U
pacientů s kataraktou se také nabízí možnost aplikace nitrooční multifokální čočky, která může
nadobro odbourat potřebu nosit jakoukoliv korekční pomůcku.
V našístudii jsme se zaměřili na skupinu nositelů měkkých kontaktních čoček. Chtělijsme
ověřit, jak nositelé s čočkami zacházejí, zda znají důležitá pravidla pro správné nošení a zda
chodí na pravidelné kontroly. Měkké kontaktní čočky získaly svou oblibu díky řadě výhod. Lidé
je často využívají při sportu, kde nejsou ohroženi úrazem způsobeným nošením dioptrických
brýlí. V oblibě jsou i u jedinců, kteří musí nosit ochranné pomůcky na oči. Mnozí lidé ocenňují
estetickou stránku kontaktních čoček.
Materiál a metody
Výzkum byl prováděn formou online dotazníku. Tuto formu výzkumu jsme zvolili díky
jeho snadné distribuci a následnému zpracování výsledků. Osloveni byli respondenti bez
rozdílu pohlaví a věku prostřednictvím sociální sítě či sesbíraných osobních dat v kartotékách
jednotlivých optik. Statisticky byly zpracovány pouze data respondentů, kteří nemají profesní
vzdělání v této problematice.
Respondenti odpovídali na dvacet sedm otázek, které byly rozděleny do šesti základních
okruhů: základní údaje, měkké kontaktní čočky (důvod nošení, výběr a nákup kontaktních
čoček), nošení kontaktních čoček (režim, délka a frekvence nošení), péče o čočky (způsob
dezinfekce čoček, frekvence výměny pouzdra na čočky), hygiena rukou a spolupráce s
kontaktologem.
Možnosti odpovědi jsme se snažili definovat co nejpřesněji, tak aby si každý respondent
mohl vybrat odpověď, která by nejlépe vystihla jeho názory a postoje k dané problematice. U
většiny otázek byla možnost otevřené odpovědi. Tu mohl dotyčný respondent využít
v případě, kdy chtěl svou odpověď zdůvodnit nebo upřesnit. K dispozici nebyly pouze
zaškrtávací otázky, ale číselné řady, které mohly oživit průběh vyplňování dotazníku.
VII. CSKO 20. 10. 2016
169
Data byla sesbírána zcela anonymně. Zájemci o výsledky studie byli vyzváni ke sdílení
svého emailu. V rámci zpětné vazby jsme pro respondenty připravili stručný přehled těch
nejdůležitějších informací, které by neměly být opomíjeny při nošení měkkých kontaktních
čoček.
Respondenti odpovídali na dotazník zcela anonymně. Zájemce o výsledky studie jsme
požádali o emailové spojení,skrz které jim budou interpretovány výsledky. Jako zpětnou vazbu
jsme pro respondenty vypracovali stručný návod, který shrnuje veškeré důležité informace pro
nositele čoček.
Výsledky
Studie probíhala od ledna do dubna tohoto roku. Celkem jsme dostali odpověď od 231
respondentů, přičemž našim kritériím odpovídalo přesně 200 dotazovaných osob. Šlo o 154
žen a 46 mužů ve věkovém rozmezí 26 5 let. Studie se účastnili jak prvonositelé, tak i lidé, kteří
čočky nosí více jak deset let.
První sekce otázek prověřila, jaký typ kontaktních čoček u nositelů převládá. Většina
respondentů úreferuje vícedenní kontaktní čočky (čtrnáctidenní nebo měsíční). Daný typ
kontaktních čoček nosí 76 % dotazovaných. Důvodem může být fakt, že 64 % respondentů nosí
čočky alespoň čtyřikrát do týdne nebo každodenně. U 48 % respondentů jsou čočky na očích
nasazeny 12-18 hodin denně a u 38 % dotazovaných 6-12 hodin denně. Dále nás zajímalo, na
základě jakých kritérií si lidé vybírají své měkké kontaktní čočky. Správně by tomu mělo být
tak, že čočky dotyčné osobně vybere kontaktolog. Samozřejmě s vámi prokonzultuje vaše
subjektivní pocity a ověří dosaženou zrakovou ostrost s touto korekční pomůckou. Výsledky
studie shrnuje Graf 1.
Graf 1: Rozhodující element při výběru konkrétních čoček
Následující sekce otázek byla věnována hygieně. Pouze 7 % respondentů necítí potřebu
umýt si ruce před aplikací kontaktní čočky. Správný postup je takový, že si ruce umyjeme před
60%25%
7%
5%3%
Na základě vyšetření a doporučení optometristy/oftalmologa
Podle parametrů oka naměřených optometristou/oftalmologem (zakřivení,
průměr, dioptrie)
Vybral jsem podle hodnoty dioptrií v brýlích
Podle toho, která mi subjektivně vyhovovala
Ostatní
VII. CSKO 20. 10. 2016
170
samotnou manipulací s čočkou, tzn. až po otevření blistru s čočkou. Takto postupuje 29 %
respondentů. Důraz musí být kladen také na hygienu pouzdra, ve kterém se vícedenní čočky
uchovávají. V každém novém balení roztoku je obsaženo i nové pouzdro. Ne každý však
s novým roztokem používá i nové pouzdro na čočky.
Graf 2: Režim výměny pouzdra
Otázky zaměřené na péči o kontaktní čočky přinesly velmi zajímavé výsledky (viz. Graf
3). Většina respondentů uvedla, že pro dezinfekci svých čoček používají víceúčelový roztok. Při
použití tohoto roztoku je nutné čočku mechanicky očistit a ne ji pouze vložit do roztoku, tak
jak tomu je například u peroxidových systémů. Víceúčelový roztok používá 63 % respondentů,
ale pravidelné mechanické čištění dodržuje pouze 29 % z nich. To že nositel uvede, že čočky
mechanicky čistí ještě nic nemusí znamenat. Otázkou zůstává jak důkladně a dlouho toto
mechanické čištění provádí. Fyziologický roztok je pro čištění zcela nevhodný. Jde v podstatě
o slanou vodu, kterou využívá 16 % dotazovaných. Nejúčinnějšího čištění čoček dosáhneme
při použití peroxidového systému.
12%
5%
14%
53%
7%
6%
3%
Pouzdro nepoužívám
1x za měsíc
1x za 3 měsíce
Pouzdro vyměňuji s nově otevřeným balením roztoku
Pouzdro vyměňuji s novým balením čoček
Pouzdro nevyměňuji
Ostatní
VII. CSKO 20. 10. 2016
171
Graf 3: Typ používaného čistícího roztoku
Závěrečný okruh otázek byl věnován prevenci. Dotazovali jsme se nositelů, jak často
docházejí na pravidelné kontroly ke kontaktologovi. Výsledky odpovědí shrnuje Graf 4. Na
pravidelné kontroly by měli nositelé docházet pravidelně minimálně jednou do roka. Potíž je
v tom, že kontaktní čočka může na oku způsobit změny, které nositel nebude vůbec vnímat.
Nic ho nemusí bolet, nic na svém oku nemusí pozorovat, ale přesto není vše v pořádku.
Graf 4: Kontroly u kontaktologa
Diskuse
Studie prokázala, že při výběru měkkých kontaktních čoček hraje velkou roli jejich cena.
Proto v České republice lidé nakupují raději čočky pro dlouhodobé nošení než ty jednodenní.
Cenově jsou výhodnější, ovšem vše jde na úkor nositelova pohodlí. Vhodným kompromisem
jsou čtrnáctidenní čočky.
Lidé často v rámci úspory peněz kontaktní čočky nosí delší dobu, než je určeno. Vůbec si
ovšem neuvědomují, že se tímto počinem vystavují vysokému zdravotnímu riziku. Problém je
obvykle v rohovkovém metabolismu. V epitelu rohovky se mohou vyskytovat mikrocysty, ve
stromatu edém a neovaskularizace. Ohrožena je také struktura endoteliálních buněk. Lidé,
16%
63%
10%
3%
2%
6%
Fyziologický roztok
Víceúčelový (All-In-One)
Roztok nepoužívám
Peroxidový
Voda
Ostatní
5%
27%
16%
6%
17%
27%
2% Častěji než 1x za rok
1x za rok
1x za 2 roky
Když mě oftalmolog/optometrista
vyzve
VII. CSKO 20. 10. 2016
172
kteří přespávají s čočkami, aniž by měli čočky pro tento režim nošení uzpůsobeny, se vystavují
riziku vzniku mikrobiální keratitidy. Toto onemocnění obvykle vede k trvalému postižení oka.
Závěr
Dnešní moderní technologie výroby umožňují nošení kontaktních čoček téměř každému.
Ať už tento prostředek využíváme jako korekční pomůcku či kosmetický doplněk (v případě
barevných kontaktních čoček), stále musíme mít na paměti, že jde o zdravotní pomůcku. Proto
je nutné dodržovat určitá opatření a minimalizovat tak možnost vzniku závažného zdravotního
stavu, který může být v případě očí dokonce ireverzibilní.
V rámci osvěty by měli být nositelé kontaktních čoček co nejlépe poučeni svým
optometristou či oftalmologem. Oční specialité by měli co možná nejvíce dbát na
informovanost svých klientů a poskytnout jim potřebné informace formou konzultací a
informačních letáků.
Poděkování
Na tomto místě bychom chtěli moc poděkovat všem participantům a kolegům, kteří nám
pomáhali dotazníky šířit mezi své klienty a pacienty.
Zdroje
Kraus, H. Kompendium očního lékařství. 1. vyd. Praha: Grada Publishing, 1997, 341 s. ISBN 80-
716-9079-1.
Petrová, S., Mašková, Z., Jurečka, T. Základy aplikace kontaktních čoček, 2. vydání, Brno:
Národní centrum ošetřovatelství a nelékařských zdravotnických oborů, 2008, 220 s. ISBN 978-
80-7013-470-2
Petrová, S., Synek, S. Úvod do speciální kontaktologie [online] 2010 [cit. 4.1.2016] Dostupné
z: http://is.muni.cz/do/1499/el/estud/lf/js10/kontakt/web/index.html
Synek, S. Kontaktní čočky [online] 2009 [cit. 4.1.2016] Dostupné z:
http://is.muni.cz/do/1499/el/estud/lf/ps09/cocky/web/index.html
VII. CSKO 20. 10. 2016
173
Compliance and hygiene behaviour among soft contact lens
wearers
Author: Bc. Barbora Hráčková, Bc. Marie Kodetová
Supervisor: Mgr. Pavel Beneš, Ph.D.
Introduction
Since the contemporal digital lifestyle is highly challenging for our eyes, people need to
adress their refractive errors more often than they used to. Prolonged lifespan of nowdays
population causes higher demand on healthy eye sight for longer time period. Evolutionary
our eye was programmed for the average life of about forty years. Today, however, there is
no problem to live twice as long. Thus nowdays we see a greater number of people who suffer
from senile presbyopia.
It is possible to choose from several ways how to solve a refractive error. The most
common approach is the use of spectacles, contact lenses or the option of undergoing a
refractive surgery. Especially but not only for patients with cataract there is also available the
change of intraocular lens. The use of intraocular multifocal lens may altogether eliminate the
need to wear any other corrective aid.
This study was focused on a group of wearers of soft contact lenses. It deals with their
sanitary and lens maintenance habits, the knowledge of essencial principles of safe contact
lens wear and the question whether they are attending their regular check-ups with an eye
care specialist.
Soft contact lenses gained its popularity due to a number of advantages. In sport
industry, contact lenses have a valuable benefit of lowering the risk of injury caused by
wearing prescription glasses. They are also popular among individuals who must use
protective eye equipment and many people appreciate their aesthetic and practical aspect.
Methods
The research was conducted by means of online questionnaire. We have chosen this
approach due to its easy distribution and efficient data processing. Our respondents were
addressed, regardless of gender and age through social media and the data were statistically
processed. The study incudes only respondents who have no professional training in the field
of optometry or oftalmology.
The study consists of twenty-seven questons which were devided into six basic areas:
personal informations
contact lenses – the reason of use, the method of selection and purchase
mode, duration and frequency of contact lens wearing
contact lens maintenance – sanitation and frequency of case replacement
hygiene
eye care specialist
VII. CSKO 20. 10. 2016
174
The majority of the questions were designed as a close-ended type in which all possible
answers were identified and the respondent was asked to choose one or more suitable
answers. Most of the questions were also allowing to write additional comment or their own
answer to choose the best one that convey his views and attitudes to the issue.
All of the data were collected anonymously. However those interested in the results
were offered the chance to share their e-mail address. All of our respondents were also given
a brief online overview of the most important information that should not be neglected while
wearing soft contact lenses.
Results
The study was conducted from January till April 2016. In total we have received response
from 268 respondent where 200 – 154 women and 46 men – were suitable for the study. Our
respondents were aged 26 ± 5 years and variously experienced with contact lens use.
The first section of questions examined what type of contact lens is favoured. Most
respondents - 76% - prefer multi-day contact lenses (Bi-weekly or Monthly). The reason may
be the fact that 64% of respondents wear lenses at least four times a week or daily. 48% of
respondents wear lenses from 12 to 18 hours a day and 38% from 6 to 12 hours a day.
One of our goals was to prioritize the set of criteria upon which people have chosen their
soft contact lenses. The proper way to procede in selection of contact lens is to attend the
proper examination of an eye care specialist, as an optometrist or an oftalmologist to choose
the suitable lens.
Graph 1: Method of contact lens selection
The following section was concerned with hygiene habits of our wearers. The correct
procedure recommends to wash hands before handling the lens itself, ie. after opening the
blister with lens. While 29% of respondents are following this routine, most of people are
washing their hands before opening the lens case. 7% of respondents do not feel the need to
wash their hands at all. The sanitation of lens case in which a multi-day lenses are kept should
also be emphasised. Every new package of contact lens solution contains a new case. Not
everyone, however, changes it.
60%
25%
7%
5% 3%
Eye specialist´s recommendation
Keratometry
According to glasses prescription
Personal choice
Other reasons
VII. CSKO 20. 10. 2016
175
Graph 2: Lens case replacement period
The next set of questions was focused on the process of contact lens sanitation. As
expected, the majority of respondents said that in order to disinfect the lens they use an Allin-one
solution. By using this solution it is also necessary to clean the lens mechanically and
not to merely place it in the solution. The mechanical cleaning is unnecessary only in case of
the peroxid systems. All-in-one solution is used by 63% of our respondents, but only 29% of
them cleanse their lens mechanicaly by rubbing. Our study, moreover, didn’t investigate the
individual process of mechanical sanitation. Due to that we cannot be certain, whether the
cleaning is done properly. Saline solution, which is basicaly a salty water is completely
unsuitable for cleaning. However 16% of respondents is using it regularly. The most effective
lens cleaning is achieved when using the peroxide system.
Graph 3: Type of the contact lens solution
The final set of question was dedicated to prevention. We have interviewed wearers
with a few questions about their eye care specialist and how often do they attend regular
check-ups regarding contact lens care. The results are summarised in Graph 4.
To be cautious and to lower the risk of complications, wearers of soft contact lenses
should visit their optometrist or oftalmologist at least once a year. Contact lens wear can be a
cause of irreversible changes of the eye that can be easily spotted by a specialist but go
unnoticed by a wearer.
12%
5%
14%
53%
7%
6% 3% Doesn't use the case
Once per month
Once per 3 months
Upon new solution opening
Upon new pack of lens opening
Doesn't replace the case
Other reasons
15%
64%
10%
3% 2% 6%
Saline solution
All-in-one solution
Doesn't use the solution
Hydrogen-peroxide solution
Water
Others
16%
63%
VII. CSKO 20. 10. 2016
176
Graph 4: Frequency of regular examinations
Discussion
The results of the study show that the price has the major influence on the type of the
lens that is chosen. Therefore most of the Czech wearers prefer to use Monthly contact lenses
instead of more expensive but easily maintainable Daily-disposable type. The suitable
compromise are Bi-weekly lenses.
People who doesn’t respect the period of wear are more exposed to the risk of eye
problems nonethless most of the respondents don’t respect the proper discard time and wear
their lenses longer than they are supposed to. Long-term contact lens use can lead to
alterations in corneal and stromal thickness, curvature, corneal sensitivity, cell density, and
epithelial oxygen uptake. Other changes may include the formation of epithelial vacuoles and
microcysts as well as the emergence of polymegethism in the corneal endothelium. People
who tend to sleep with lenses and don’t use appropriate type for prolonged wear (lenses
suitable for overnight wear) are exposed to the risk of microbial keratitis. This disease can
usually cause permanent eye demage. While contact lenses are safely used by millions of
people every day, they do carry a risk of eye infection. And this risk is increased by improper
use.
Conclusion
Up to date contact lens production technologies suit almost every user. It is important
to consider the lens as a medical instrument no matter if we are using this tool as for refractive
correction or as an accessory. Following certain basic rules of usage is essential for avoiding
the severe health damage with possible lifelong consequences.
The contact lens wearers should be properly educated in this area before the first
application. Optometrists, ophthalmologists and lens vendors should offer all necessary
information to their clients in form of consultations and flyers and demand the regular
examination for proper health and protection of client‘s eyesight.
Acknowledgement
We would like to thank to all of our colleagues who participated gaining data in this
research.
5%
27%
16%
5%
17%
27%
3% More than once a year
Annually
Once in two years
On the eye specialist's invitation
Only when complications occure
Doesn't go to examinations
Other response
VII. CSKO 20. 10. 2016
177
References
Kraus, H. Kompendium očního lékařství. 1. vyd. Praha: Grada Publishing, 1997, 341 s. ISBN 80-
716-9079-1.
Petrová, S., Mašková, Z., Jurečka, T. Základy aplikace kontaktních čoček, 2. vydání, Brno:
Národní centrum ošetřovatelství a nelékařských zdravotnických oborů, 2008, 220 s. ISBN 978-
80-7013-470-2
Petrová, S., Synek, S. Úvod do speciální kontaktologie [online] 2010 [cit. 4.1.2016] Dostupné
z: http://is.muni.cz/do/1499/el/estud/lf/js10/kontakt/web/index.html
Synek, S. Kontaktní čočky [online] 2009 [cit. 4.1.2016] Dostupné z:
http://is.muni.cz/do/1499/el/estud/lf/ps09/cocky/web/index.html
VII. CSKO 20. 10. 2016
178
Změna refrakce a aberací po operaci šedého zákalu
Autor: Bc. Lenka Novotná, DiS.
Školitel: MUDr. Tomáš Mňuk
Úvod
Jako kataraktu označujeme jakýkoli zákal čočky, který negativně ovlivňuje vidění. Patří
mezi jeden z fyziologických projevů stárnutí, který však může vést až ke slepotě. Podle Světové
zdravotnické organizace (WHO) je v současnosti na světě přes 20 miliónů lidí, kteří oslepli
v důsledku katarakty a v roce 2020 to má být až 40 miliónů lidí. Zatím žádná konzervativní
léčba nemůže oddálit vznik katarakty nebo zastavit její rozvoj. Pro tento stav kalení čočky
neexistuje v současné době lepší léčba, než je léčba chirurgická – operace. Operace šedého
zákalu je jedním z nejčastějších chirurgických výkonů. Hlavním cílem zákroku je zkvalitnění
života nemocného. Indikací k operaci jsou subjektivní potíže nemocného a to především
sníženízrakové ostrosti a kontrastní citlivosti. Standardní operace katarakty je dnes prováděna
ambulantně malým řezem v lokální anestezii technikou fakoemulzifikace s implantací měkké
nitrooční čočky. Budoucí vývoj chirurgie katarakty se v poslední době opírá hlavně o rozvoj
metody laserem asistované operace katarakty. Rychlý vývoj za sebou mají i materiály
používané pro výrobu umělých čoček, kde jejich progrese směřuje k vývoji bioanalogických
materiálů a k zavedení plně akomodujících umělých nitroočních čoček.
Katarakta – příčiny, typy, příznaky
Katarakta může být vrozená nebo získaná. Přičiny kongenitálních katarakt jsou heredita,
teratogenní látky (léky) a virová onemocnění během gravidity. U některých forem získaných
katarakt je příčina zákalu známa. Jinde ji neznáme a hovoříme pouze o tzv. kataraktogenních
faktorech. Mezi ně řadíme UV záření, kouření cigaret, diabetes mellitus nebo podávání
kortikosteroidů. Senilní katarakty, které jsou nejběžnější, můžeme podle lokalizace zákalu
rozdělit na: nukleární, kortikální, zadní subkapsulární a přední subkapsulární. Pro nukleární
kataraktu je typický zákal od jejího jádra, ten mívá pomalý vývoj táhnoucí se několik roků.
Obr. 1: Nukleární katarakta
Hnědavé jádro čočky získává jiný index lomu a oko myopizuje. Kortikální katarakta začíná
kalením korových vrstev čočky.
VII. CSKO 20. 10. 2016
179
Obr. 2: Kortikální katarakta
Stupěň zhoršení zraku se liší podle umístění a hustoty zákalu v čočce. Zákaly v optické
ose oka způsobují větší pokles vidění než zákaly při okraji oční čočky. U zadní subkapsulární
katarakty je zákal přítomen v zadní vrstvě kortexu čočky.
Obr. 3: Zadní subkapsulární katarakta
Častěji se objevuje u mladších pacientů jako důsledek užívání kortikosteroidů, po
ionizujícím záření nebo po traumatu. Přední subkapsulární katarakta je svým výskytem
vzácnější.
Obr. 4: Přední subkapsulární katarakta
VII. CSKO 20. 10. 2016
180
Zkalení čočky se vyskytuje těsně pod předním pouzdrem. U pacientů s kataraktou se
vlivem rozptylu světla zhoršuje kontrastní citlivost a dochází k oslňování. Pacienti pozorují
zhoršené vidění za slunce a při řízení auta. Časté jsou poruchy i barevného vidění a
monokulární diplopie. V důsledku změny indexu lomu čočkové hmoty, dochází k myopizaci,
což u některých pacientů vede k odkládání brýli do blízka a mají pocit zlepšení zraku.
Předoperační vyšetření
Velmi citlivá metoda v diagnostice počínající katarakty je vyšetření zrakové ostrosti za
sníženého světelného kontrastu. K vyšetření transparence oční čočky nejčastěji využíváme
biomikroskopii na štěrbinové lampě při mydriáze. Minimální změny v průzračnosti čočky,
které na štěrbinové lampě nemusíme vidět, umožňuje změřit denzitometrie za pomoci
Scheimpflugovy kamery. S rostoucími požadavky pacientů na refrakční výsledek je kladen
velký důraz na přesnost předoperačních měření. Pomocí těchto vyšetření získáme mimojiné
parametry k výpočtu optické mohutnosti nitrooční čočky, což jsou z refrakčního hlediska
nezbytné údaje pro operaci. Keratometrem zjistíme zakřivení přední plochy rohovky a hodnoty
optické mohutnosti rohovky v daném meridiánu. Pomocí barevných topografických map
získáme dioptrické hodnoty odpovídající naměřeným poloměrům křivosti jednotlivých částí
rohovky a zjišťujeme rohovkový astigmatismus, který můžeme při operaci katarakty vyřešit
pomocí nářezů na rohovce, tzv. keratotomií nebo implantací torické IOL. Biometrie slouží k
výpočtu optické mohutnosti umělé čočky. U optické biometrie je měřena optická délka mezi
povrchem rohovky a pigmentovým epitelem sítnice, která je následně přepočítána na
geometrickou délku. Subjektivní zrakové funkce a jejich vliv na každodenní činnost
nemocného lze zjistit testem VF-14 (Index of Visual Functioning).
Aberometrie
Aberace vyšších řádů představují složku refrakční vady, kterou sférocylindricky nelze
vykorigovat. Aberometrie byla původně zkonstruována pro dignostiku a léčbu aberací vyšších
řádů po refrakčním laserovém zákroku. I při začínající kataraktě se zvyšují aberace vyšších řádů
a proto je pomoc tohoto přístroje při diagnostice i při následném porovnání předoperačních a
pooperačních hodnost, neocenitelná.
Kataraktová chirurgie
Podstata operace šedého zákalu spočívá ve vyjmutí – extrakci oční čočky. Rozlišujeme
extrakci intrakapsulární a extrakapsulární. Intrakapsulární extrakce se dnes používá jen zřídka.
Spočívá ve vyjmutí celé čočky s intaktním pouzdrem a nese sebou řadu komplikací. Dnes se
převážně provádí exktrakapsulární extrakce, kdy je odstraněné zkalené čočkové jádro a kortex
čočky se zachováním převážné části čočkového pouzdra v původním postavení. Do
zachovalého pouzdra implantujeme nitrooční čočku. Nejčastěji technika extrakapsulární
extrakce spočívá ve fakoemulzifikaci, kdy za pomocí ultrazvuku současně odsáváme a
vyplachujeme čočkové jádro a hmoty. Velmi perspektivní metodou v kataraktové chirurgii je
laserem asistovaná operace katarakty. Používány jsou dva typy laserů: Erbium: YAG laser (Er:
YAG) a Neodymium: YAG (Nd: YAG) laser. Předností laserové operace katarakty je precizní
kapsulorhexe a rozmělnění čočkového jádra a také fakt, že nedochází k uvolnění tepelné
VII. CSKO 20. 10. 2016
181
energie jako při fakoemulzifikaci. U nekomplikované katarakty operace trvá přibližně 15
minut. Ke stabilizaci vidění dochází většinou za 2 až 4 týdny po operaci.
Nitrooční čočky
Zjednodušeně lze volit mezi dvěma typy čoček: tvrdou a měkkou. Tvrdé čočky jsou
vyrobeny z polymetylmetakrylátu (PMMA), který má výborné optické vlastnosti, ale není
elastický. Takováto čočka je tvrdá a rigidní, její vložení vyžaduje větší vstupní ránu, což je hlavní
důvod, proč dnes převažuje implantace čoček měkkých. Měkké čočky jsou flexibilní, dají se
složit, srolovat a implantovat pomocí speciálního injektoru velmi malým řezem o velikosti 3,0
mm a menším, s tím je pak spojeno menší riziko endoftalmitidy a pooperačního astigmatismu.
Nejnovějším materiálem, který se začíná implantovat, je Collamer, kombinace silikonu
a kolagenu. Pacient si dnes v praxi může vybrat mezi čočkou standardní, plně hrazenou
zdravotní pojišťovnou nebo nadstandardní (asférickou, tórickou, multifokální, akomodační),
kde si doplácí. Většina nitroočních čoček je vybavena UV filtry, protože vlastní lidská čočka do
jisté míry UV- záření absorbuje, čímž chrání sítnici a ostatní struktury oka.
Závěr
Nespočet studií prokazuje výrazné zlepšení zrakové ostrosti po operaci katarakty. Rozvoj
nových laserových metod operace a biokompatibilních materiálů pro nitrooční čočky sebou
nese velmi nízký výskyt komplikací a pacientům prokazatelně zlepšuje kvalitu jejich života.
Zdroje
Autrata, R. Nauka o zraku. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví,
2002. ISBN 80-7013-362-7.
Brian, G., Taylor, H. Cataract blindness - challenges for the 21st century. Bulletin of the WHO.
2001; 79(3): 249-256.
Kraus, H., Karel, I., Růžičková, E. Oční zákaly. Praha: Grada, 2001. ISBN 80-7169-967-5.
Kuchynka, P. Oční lékařství. 2., přepracované a doplněné vydání. Praha: Grada Publishing,
2016. ISBN 978-80-247-5079-8.
Skorkovská, Š., Michálek, J., Ruberová, M., Synek, S. Srovnání ultrazvukové a optické biometrie
s ohledem na refrakci oří po operaci katarakty. Čes. a slov. Oftal. 2004; 60(1): 24 - 29.
Vlková, E., Vlk, F. Lexikon očního lékařství: výkladový ilustrovaný slovník. Brno: František Vlk,
2008. ISBN 978-80-239-8906-9.
VII. CSKO 20. 10. 2016
182
Change in refraction and aberration after cataract surgery
Author: Bc. Lenka Novotná, DiS.
Supervisor: MUDr. Tomáš Mňuk
Introduction
Cataract is clouding of the lens, which negatively affects vision. Cataract is one of the
physiological effects of aging, but it can lead to blindness. According to the World Health
Organization (WHO) is currently on the world over 20 million people going blind due to
cataracts, and in 2020 it should be up to 40 million people. So far, no conservative treatment
can delay cataract or stop its development. For this state of clouding of the lens currently
there is the best treatment surgical treatment - operation. Cataract surgery is one of the most
frequency surgical procedures. The main aim of surgery is to improve the patient's life.
Indications for surgery are subjective complaints of the patient, especially a reduction in visual
acuity and contrast sensitivity. Standard cataract surgery today is done on an outpatient
department through a small incision under local anesthesia technique of phacoemulsification
with implantation of soft intraocular lenses. Future development of cataract surgery recently
relies mainly on developing methods for laser-assisted cataract surgery. Rapid development
have also materials used to producing intraocular lenses, where their progression lead to
deveploment of bioanalogous materials and the fully accommodating intraocular lenses.
Cataract - causes, types, symptoms
Cataracts may be congenital or acquired. Causes of congenital cataracts are heredity,
teratogenic substances (drugs) and viral diseases during pregnancy. Some forms of acquired
cataracts have known causes. Elsewhere, we do not knot the causes and we are talking only
about cataractogenic factors. Its UV radiation, cigarette smoking, diabetes mellitus, or
corticosteroid therapy. Senile cataracts, which are the most common, can be divided
according to the localization of clouding into: nuclear, cortical, posterior subcapsular and
anterior subcapsular. Typical sign for nuclear cataract is clouding of nucleus, whith usually
slow development for several years.
Picture 1: Nuclear cataracts
VII. CSKO 20. 10. 2016
183
Brown nukleus of lens acquires a different index of refraction and eye make a myopic
eye. Cortical cataract starts as a clouding of the lens cortical layers.
Picture 2: Cortical cataracts
The degree of visual deterioration is different according to location and density of
cloudiness in the lens. Cataracts in the optical axis of the eye cause a greater decrease than
cloudiness at the edge of the ophthalmic lens. By posterior subcapsular cataract is cloudiness
located in the back layer of the lens cortex.
Picture 3: Posterior subcapsular cataracts
Often occurs by younger patients as a result of corticosteroid use, after ionizing
radiation, or after trauma. Anterior subcapsular cataract is rarer.
VII. CSKO 20. 10. 2016
184
Picture 4: Anterior subcapsular cataracts
Clouding of the lens occurs just below the front layer of case. In patients with cataracts
is due to light scattering deteriorates contrast sensitivity and glare occurs. Patients observe
impaired vision in the sun and driving. Disorders are common and color vision monocular
diplopia. As a result of changes in the refractive index of the lens material, there is myopic
eye, which in some patients led to the hold of glasses for near vision and they feel they have
better vision.
Preoperative examination
Very sensitive method in the diagnosis of incipient cataract is visual acuity under
reduced contrast of the light. To investigate the transparency of the eye lens is frequently use
a slit lamp biomicroscopy at mydriasis. Minimal changes in the transparency of the lens, which
slit lamp do not need to see, we can measure with densitometry with Scheimpflug camera.
With the increasing demands of patients in the refractive outcome is a great emphasis on the
accuracy of preoperative measurements. Through these tests we get, among others
parameters to calculate the optical power of intraocular lenses, which are the terms of
refractive information necessary for operation. With keratometer we find out curvature of
anterior corneal surface and the optical power of the cornea in a exist meridian. Use the color
topographic maps we obtained diopter values corresponding to the measured radius of
curvature of the individual parts of the cornea and we find out corneal astigmatism that we
can resolve in cataract surgery through incisions in the cornea called keratotomies or
implantation of toric IOLs. Biometrics is used to calculate the optical power of intraocular lens.
Biometrics is measured optical path length between the surface of the corneal and retinal
pigment epithelium which is subsequently converted to the geometric length. Subjective
visual functions and their impact on the daily activities of the patient's test can detect VF-14
(Index of Visual Functioning).
Aberration
Aberrations of higher order are a component of refractive error, which can not be repair
with sphero-cylindrical values. The instrument for measuring aberration was originally
designed allows diagnostic and treatment of higher order aberrations after refractive laser
surgery. Even when he cataract starts higher order aberrations are increasing and thus help in
VII. CSKO 20. 10. 2016
185
the diagnosis and the subsequent comparison of preoperative and postoperative rank
invaluable.
Cataract surgery
Principle of cataract surgery involves removal - extraction of the ophthalmic lens. We
have extraction intracapsular and extracapsular. Intracapsular extraction is now rarely used.
It consists in removing the whole lens with an intact capsule and brings many complications.
Today, mainly performs extracapsular extraction when the clouded lens nucleus is removed
and cortex of the lens by keeping the major part of the capsule remainin the original position.
The well-preserved capsule we implanted intraocular lens. Most often extracapsular
extraction technique consists in phacoemulsification, when using ultrasound simultaneously
vacuuming and washing the lens nucleus and matter. Very promising method in cataract
surgery is a laser-assisted cataract surgery. We used two types of lasers: Erbium: YAG laser
(Er: YAG) and Neodymium: YAG (Nd: YAG) laser. The advantage of laser cataract surgery is
precise and milling kapsulorhexe lenticular nucleus and the fact that it does not release heat
as during phacoemulsification. For uncomplicated cataract surgery takes approximately 15
minutes. Stabilized vision mostly occurs at 2-4 weeks after surgery.
Intraocular lenses
Simply you can choose between two types of lenses: hard and soft. Hard lenses are made
from polymethylmethacrylate (PMMA) having excellent optical properties, but is not elastic.
Such a lens is hard and rigid, its inclusion requires a larger entry wound, which is the main
reason why today prevails implantation of soft lenses. Soft lenses are flexible, they can be
folded, rolled and implanted using a special injector very small incision of 3.0 mm and smaller,
it is then associated with smaller risk of endophthalmitis and postoperative astigmatism. The
newest material that begins to be implanted, is collamer, a combination of silicone and
collagen. Patients today in practice can choose between a standard lens, fully paid by health
insurance or premium (aspherical, toric, multifocal, accommodative), where pacient have to
paid something. Most IOLs are equipped with UV filters, because of the human lens absorbs
UV radiation, thereby protecting the retina and other structures of the eye.
Conclusion
Countless studies show a significant improvement in visual acuity after cataract surgery.
Development of new methods of laser surgery and biocompatible materials for intraocular
lenses carries a very low incidence of complications and patients significantly improved their
quality of life.
Resources
Autrata, R. Nauka o zraku. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví,
2002. ISBN 80-7013-362-7.
Brian, G., Taylor, H. Cataract blindness - challenges for the 21st century. Bulletin of the WHO.
2001; 79(3): 249-256.
Kraus, H., Karel, I., Růžičková, E. Oční zákaly. Praha: Grada, 2001. ISBN 80-7169-967-5.
VII. CSKO 20. 10. 2016
186
Kuchynka, P. Oční lékařství. 2., přepracované a doplněné vydání. Praha: Grada Publishing,
2016. ISBN 978-80-247-5079-8.
Skorkovská, Š., Michálek, J., Ruberová, M., Synek, S. Srovnání ultrazvukové a optické biometrie
s ohledem na refrakci oří po operaci katarakty. Čes. a slov. Oftal. 2004; 60(1): 24 - 29.
Vlková, E., Vlk, F. Lexikon očního lékařství: výkladový ilustrovaný slovník. Brno: František Vlk,
2008. ISBN 978-80-239-8906-9.
VII. CSKO 20. 10. 2016
187
Prizmatická korekce
Autor: Bc. Tereza Ouhelová
Školitel: Mgr. Matěj Skrbek
Práce celým svým názvem „Podmínky úspěchu předpisu prizmatické korekce“ je jedním
z největších otazníků optometrické praxe. Zatím nebyla stanovena stoprocentně platná
pravidla pro předpis prizmatické korekce. Tento příspěvek je pouze shrnutím základních údajů
o tom, co je to prizmatický účinek a jak vzniká, kde se prizmatická korekce využívá a jak lze
prizmatickou korekci stanovit.
Co je to prizmatický účinek?
Optický klín je hranol s bází a dvěma lámavými plochami. Tento hranol s malým
lámavým úhlem se používá v případě, kdy je potřeba odklonit chod světelných paprsků od
původního směru.
Obrázek 10: Odklon chodu světelných paprsků od původního směru
Odchylku paprsku nazýváme deviace a lze ji vypočítat dle vzorce:
𝛿 = (𝑛 − 1) ∙ 𝜑,
kde 𝛿 je deviací paprsku, 𝑛 je označení pro index lomu hranolu a 𝜑 je lámavý úhel
hranolu.
Deviaci můžeme také nazvat prizmatickým účinkem, jehož hodnotu udáváme
v prizmatických dioptriích [pD]. Prizmatický účinek jedné prizmatické dioptrie má optický klín,
který ve vzdálenosti jednoho metru odkloní paprsek o jeden centimetr.
Obrázek 11: Prizmatický účinek
Prizmatický účinek lze navodit decentrací brýlové čočky, tj. posunem jejího optického
vrcholu. Výhodou takto navozeného prizmatického účinku je nižší cena a brzké zhotovení. Na
VII. CSKO 20. 10. 2016
188
druhé straně ale stojí řada nevýhod jako je například omezený prizmatický účinek, snížení
kvality zobrazení nebo nedostačující průměr čočky. Druhou možností jak dosáhnout
požadované prizmatické korekce je objednání prizmatické čočky, kterou najdeme v katalogu
výrobců brýlových čoček. Hlavní výhodou je vyšší kvalita zobrazení, minimalizace vad
zobrazení a například možnost zhotovení jak sférické, cylindrické tak i bifokální nebo
multifokální čočky. Nevýhodami jsou však například vyšší pořizovací cena a čekací doba výroby
této čočky. Speciálním typem dosažení prizmatického účinku je Waferovo nebo Fresnelovo
prizma. Waferovo prizma z umělé hmoty lze připevnit na normální brýlové sklo. Je složeno
z řady hranolů formovaných do proužku.
Obrázek 12: Waferovo prizma
Novějším typem je Fresnelovo prizma tvořeno soustavou prizmat s bázemi
orientovanými shodně. Jsou to folie, jejichž hlavní výhodou je lehkost, ztenčení a snadná
manipulace. Nalepují se na zadní část brýlového skla vsazeného do brýlové obruby. Snižujívšak
zrakovou ostrost a kontrastní citlivost nositele.
Obrázek 13: Fresnelova folie
Velikost prizmatického účinku lze vypočítat dle Prenticeho rovnice. Prizmatický účinek
Δ, který bude na oko působit, bude-li se dívat mimo optický střed čočky o vrcholové lámavosti
𝑆′, lze vypočítat dle vzorce: 𝛥 = 𝑑𝑒𝑐 ∙ |𝑆′| / 10.
Tato rovnice byla později rozšířena Weinholdem, který ve svém vzorci respektuje
vzdálenost brýlové čočky od oka: 𝛥 = 𝑑𝑒𝑐 ∙ |𝑆′| / 1 − (𝑑 + 0,013) ∙ 𝑆′.
Využití prizmatické korekce
Binokulární vidění znamená vidět oběma očima pozorované objekty. Jednoduché
binokulární vidění umožňuje vytvoření jednoduchého obrazu pozorovaného předmětu, je to
schopnost vidět oběma očima pozorovaný předmět jednoduše (ne dvojitě). Stupně
jednoduchého binokulárního vidění jsou 1. superpozice, tj. schopnost překrýt oběma očima
VII. CSKO 20. 10. 2016
189
nestejné obrázky; 2. fúze, tj. spojit obraz pravého a levého oka v jeden smyslový vjem; 3.
stereopse, tj. vytvořit hloubkový vjem pozorovaných obrazů.
Mezi binokulární oční pohyby řadíme verzi (pohyb očí ve stejném směru) a vergenci
(pohyb očí v opačném směru). Mezi vergenční, nekonjugované (disjunktivní), pohyby řadíme
konvergenci (pohyb očí směrem dovnitř) a divergenci (pohyb očí směrem ven).
Prizmatickou korekci používáme k navození disjunktivních (vergenčních) pohybů, kdy se
oči hýbou opačným směrem. Setkáme se s ní zejména při korekci forií a tropií.
Nejprve je nutno říci, že ortoforie, neboli rovnovážný stav okohybných svalů, kdy je
dosaženo jednoduchého binokulárního vidění bez odchylky fixace obou očí, osy vidění obou
očí jsou při pohledu do dálky rovnoběžné a po zrušení fúze se vzájemné postavení očí nezmění,
se v populaci vyskytuje pouze ve 20 %. (Divišová, 1990)
Heterotropie, neboli strabismus, tj. zjevné šilhání, je stav očního aparátu, kdy osy vidění
se neprotínají ve stejném bodě, a je porušeno jednoduché binokulární vidění. Tato porucha je
navenek provázená asymetrickým postavení očí. Korekce heterotropie je spíše v kompetenci
práce oftalmologů.
Heteroforie je na rozdíl od heterotropie skrytým, latentním šilháním. Vyznačuje se
nerovnováhou zevních očních svalů po zrušení fúze. Je to porucha binokulární fixace právě po
zrušení fúze. Z hlediska etiologie rozlišujeme heteroforii statickou, která je podmíněna
vrozenými anomáliemi očnic, očních bulbů nebo očních svalů, dále akomodační způsobenou
poruchou AC/A poměru (poměr akomodační konvergence na jednotku akomodace), anebo je
heteroforie poruchou neurogenní. Dle směru odchylky rozlišujeme heteroforie horizontální
(esoforie- směrem dovnitř a exoforie-směrem ven), vertikální (hyperforie a hypoforie),
cykloforie (excykloforie nebo incykloforie) nebo odchylky smíšené.
Heteroforie můžeme rozdělit na kompenzovanou, kdy je vergenční systém schopen sám
odchylku překonat a není nutná korekce vady. Korigovat je ale potřeba dekompenzovanou
heteroforii, kdy vergenční aparát není schopen sám odchylku překonat, nastává rozmazané
vidění, diplopie i astenopické potíže a může vzniknout fixační disparita, neboli odchylka
fixačních os, kdy jednoduché binokulární vidění je zachováno.
Disociovaná heteroforie je stav, kdy fixační linie očí jsou v odchýleném postavení,
nefixují bod a fúze je zrušena. Vyšetření lze provádět například pomocí Maddoxova testu.
Asociovaná heteroforie neboli úhlová odchylka fixace je stav očního aparátu, kdy oči
v odchýleném postavení fixují, je zde přítomnost fúze i fúzních podnětů. Vyšetření lze
provádět pomocí metod MKH a Malletova testu.
VII. CSKO 20. 10. 2016
190
Obrázek 14: Malletův test
Stanovení prizmatické korekce
Diagnostika heteroforie je možná pouze po zrušení fúzních podnětů (například zakrytí
jednoho oka, mechanické rozdělení vjemu pravého a levého oka, červeno-zelené testy). Pokud
používáme centrální nebo periferní fúzní podnět, diagnostikujeme a měříme fixační disparitu.
Vyšetření heteroforie bychom měli začínat zakrývacím testem, kdy heteroforii jsme
schopni zjistit rychlým střídáním zakrývací destičky a pozorováním odkrývaného oka.
Maddoxův test se skládá z Maddoxova kříže s bodovým zdrojem světla a Maddoxovy
destičky s liniemi, kterou předložíme před jedno oko. Na kříži pak můžeme přímo zjistit
velikost a směr úchylky (tj. vzdálenost posunutí linie vyvolané bodovým zdrojem světla přes
destičku).
Bagoliniho skla jsou skla s vroubky pod úhly 135° a 45°, po jejich předložení před obě oči
dochází k rozptylu bodového zdroje světla do dvou linií kolmo na směr vroubkování.
Schoberův a Worthův test jsou anaglyfní testy, které lze použít pro vyšetřování do dálky
i do blízka.
Metoda MKH jako součást polatestu je nejnovější metodou měření heteroforie a fixační
disparity. Obsahuje několik testů, kdy pouze K-test vyšetřuje heteroforii a její motorickou část,
ostatní testy jako je ručičkový (R), hákový (H-test), stereotest (S) a stereovalenční test (SV)
slouží k diagnostice a měření fixační disparity.
VII. CSKO 20. 10. 2016
191
Obrázek 15: Schoberův test, Maddoxův kříž, Worthova světla, MKH
Graefovo prizma je vertikální prizma 6-8 pD, které se předkládá před jedno oko
k vytvoření umělé diplopie. Theringtonova varianta je modifikací do dálky i do blízka, kdy přes
prizma 12 pD dochází k posunu šipky na stupnici, která ukazuje na velikost a směr úchylky.
Obrázek 16: Karta forií
Důležité je vždy správně vykorigovat refrakční vadu. Například nekorigovaný
hypermetrop bude mít sklon k esoforii, myop naopak k exoforii. Korekci heteroforii můžeme
provádět pomocí ortoptického výcviku na haploskopu- troposkop, synoptofor, kde posilujeme
opačnou šířku fúze (u esoforie cvičení negativní fúzní rezervy- divergence).
Předpis prizmatické korekce se řídí několika pravidly:
Maddoxovo pravidlo - esoforii nad 3 pD korigujeme 50%, exoforii nad 2 pD 60% a
vertikální úchylky 80-100%
Sheardovo kritérium - opačně orientovaná šířka fúze musí být velká alespoň jako
dvakrát hodnota heteroforie, aby nevznikala astenopie: 𝑂Š𝐹 ≥ 2 𝑥 𝐻𝑇𝐹
Percivalovo kritérium - prizmatický účinek dle vzorce: ∆ =
1
3
𝑉𝐹𝑅 −
2
3
𝑀𝐹𝑅, kde VFR
jsou větší fúzní rezervy a MRF menší fúzní rezervy
MKH - pravidlo předpisu plné naměřené korekce.
Rutrle doporučuje při korigování pomocí prizmatických čoček začínat vložením 1 pD
v horizontálním směru, pro úchylku ve směru vertikálním 0,5 pD. Na 4 pD by mělo
docházet k posunu vztaženého bodu brýlové čočky o 1 mm proti směru báze.
Nežádoucí účinky prizmatické korekce jsou nejčastěji zkreslení vjemu, barevná vada,
makropsie nebo mikropsie (zvětšení nebo zmenšení pozorovaného objektu). Nositelé si
mohou stěžovat na bolesti hlavy i očí, je zde delší doba návyku.
Závěr
Tento příspěvek je pouze krátkým shrnutím základních bodů při diagnostice a korekci
heteroforie pomocí prizmatických korekčních pomůcek. Zdaleka zde není obsaženo vše, čím
lze prizmatickou korekci charakterizovat. Aplikace prizmatické korekce je velice individuální
záležitostí a je třeba ke každému klientovi přistupovat s individuální péčí. Práce „Podmínky
úspěchu předpisu prizmatické korekce“ nebude tedy sloužit jako návod pro předpis
VII. CSKO 20. 10. 2016
192
prizmatické korekce, spíše bude zmapováním nejvyužívanějších metod diagnostiky a korekce
heteroforií napříč územím České republiky. Práce bude poskytovat informace o
nejvyužívanějších metodách, pravidlech předpisů i například objednávkách prizmatických
čoček na základě největší úspěšnosti a spokojenosti klientů.
Zdroje
Hromádková, L. Šilhání. 3. nezměněné vyd. Brno: Národní centrum ošetřovatelství a
nelékařských zdravotnických oborů, 2011. str. 162. ISBN 978-80-7013-530-3.
Divišová, G. Strabismus. 2. vydání. Praha: AVICENUM, 1990. 312 s. ISBN 08-039-90.
Veselý, P. Využití Polatestu v praxi optometristy. 2007.
Jexová, S. Geometrická optika. Vyd. 1. Brno: Národní centrum ošetřovatelství a nelékařských
zdravotnických oborů, 2010. str. 218. ISBN 978-80-7013-521-1.
Najman, L. Prizmatická korekce. Česká oční optika. Brno: Společenstvo českých optiků a
optometristů, listopad 2012, č. 4/2012, roč. 53, stránky 30-34. ISSN 1211-233X.
Schwendtová, V., Brunner, R. Geometrická a pristrojová optika. [1.vyd.]. Martin: Osveta, 1998.
str. 292. ISBN 978-80-2170-523-4.
Rutrle, M. Binokulární korekce na polatestu. Vydání: první. Brno: Institut pro další vzdělávání
pracovníků ve zdravotnictví, 2000. str. 115. ISBN 80-7013-302-3.
VII. CSKO 20. 10. 2016
193
Prismatic correction
Author: Bc. Tereza Ouhelová
Supervisor: Mgr. Matěj Skrbek
The full name of the thesis “Conditions for the success of the prescription of the
prismatic correction” is one of the biggest question marks optometric practice. It hasn’t been
determined 100% valid rules for prescription of prismatic correction yet. This text is only a
summary of the basic data about what is the prismatic effect and how it works, where we can
use prismatic correction and how we can determine amount of prism.
What is the prismatic effect?
The optical prism has got a base and two faces. This optical prism with a small angle on
the top is used when it is necessary to divert the course of the light rays from the original
direction.
Picture 1: The deviation of the ray
The deviation of the ray we can call the deviacy and it can be calculated according to the
formula:
𝛿 = (𝑛 − 1) ∙ 𝜑,
where 𝛿 is the deviacy of the prism, 𝑛 characterized the conditions and material of the
optical prism and 𝜑 is an angle of optical prism. The deviacy we can also call prismatic effect.
Its value we can set in prismatic diopter [pD]. Prismatic effect of a single diopters has the
optical prism, which deflects the ray about one centimeter at a distance of one meter.
Picture 2: Prismatic effect
Prismatic effect can be induced by moving optic center of spectacle lenses. The
advantage of this method is lower price, and speedy creation. On the other side there is a
number of disadvantages such as limited prismatic effect, reduce visual quality or insufficient
VII. CSKO 20. 10. 2016
194
of the diameter of the lens. The other option to achieve the desired prismatic correction is
ordering prismatic lenses, which we can find in the catalog of the manufacturers of spectacle
lenses. The main advantage is the higher visual quality, minimizing the defects on the vision
and, for example, the possibility of making spherical, cylindrical and bifocal or multifocal
lenses. Disadvantages are, however, such as higher cost and waiting time of production of this
lens. A special type of achieve the prismatic effect is Wafer or Fresnel prism. Wafer prism
made of plastic can be attached to a normal eyeglass in the frame. It is composed of series of
optical prisms formed into the strip.
Picture 17: Wafer prism
The newer type is Fresnel prism consists of a system of focal point with the bases
oriented identically. Its composed by the foils, whose main advantage is lightness, thinning
and easy handling. Plastic foils can be fixed on the back part of spectacled glass in frames.
However, Fresnel prism can reduce visual acuity and contrast sensitivity for the wearer.
Picture 18: Fresnel prism
The amount of the prismatic effect can be calculated by Prentice's equation. Prismatic
effect Δ, which affect the eye looking out of the optical center, can be calculated according to
the formula: 𝛥 = 𝑑𝑒𝑐 ∙ |𝑆| / 10.
This equation was later extended by Weinhold. His new formula respects the distance
of the lenses from the eye: 𝛥 = 𝑑𝑒𝑐 ∙ |𝑆| / 1 − (𝑑 0,013) ∙ 𝑆′.
The use of prismatic correction
Binocular vision means seeing with both eyes observed objects. Simple binocular vision
allows the creation of simple image of observed object, it is the ability to see with both eyes
the object observed simply (not double). The degrees of simple binocular vision are:
1. superposition, i.e. the ability to overlay both eyes different images; 2. fusion, i.e. to
combine the image of the right eye and the left eye in one sense; 3. stereopse, i.e. to create
an in-depth perception of the observed images.
VII. CSKO 20. 10. 2016
195
The binocular eye movements are version (the movement of the eyes in the same
direction) and vergence (eye movement in the opposite direction).
To the vergence eye movements we can include unconjugated (disjunctive) movements
such as convergence (movement of the eyes inward) and divergence (eye movement
outward).
Prismatic correction we can use to induce disjunctive (vergence) movements when the
eyes move in the opposite direction. We can use especially for the correction of phoria and
tropia.
First it is necessary to say what is ortophoria. Ortophoria or equilibrium of the
oculomotor muscles is achieved by a simple binocular vision without deviations of the fixation
of both eyes, the axis of vision of both eyes looking into the distance are parallel and after
cancel the fusion there is no deviation of the position of the eyes. Ortophoria occurs only 20%
in the population. (Divišová, 1990)
Heterotropia, or strabismus, i.e. obvious strabismus, is the condition of the vision
apparat, when the axis of vision do not intersect in the same point, and is violated simple
binocular vision. This disorder is outwardly guided by the asymmetrical position of the eyes.
Correction heterotropia is rather in the competence of the work of the ophthalmologists.
On the other hand of heterotropia, heterophoria is hidden. It is characterized by an
imbalance of the external ocular muscles after the cancellation of the fusion. It is a disorder
of binocular fixation just after the cancellation of the fusion. From the perspective of etiology,
we distinguish heterophoria static, which is determine by congenital anomalies of the orbits,
the eye or the eye muscles, further accommodative heterophoria caused by the disorder of
the AC/A ratio (ratio of accommodative convergence per unit of accommodation), or
heterophoria as a neurogenic disorder. According to the direction of the deviation we
distinguish heterophoria horizontal (esophoria - inwards and exophoria-outwards), the
vertical (hyperphoria and hypophoria), cyclophoria (excyclophorie or incyclophoria) or mixed
deviations.
Heterophoria can be divided into compensated, when vergence system can overcome
the deviation and it is not a required correction of defects. But we have to correct
decompensated heterophoria, when vergence system is not able to overcome the deviation,
occurs blurred vision, diplopia and asthenopic disorders and may cause fixation disparity, or
the deviation of the fixation axis, where the simple binocular vision is maintained.
Dissociated heterophoria is a condition where the fixation lines of the eyes are in
deflected position, do not fixed close point and the fusion is cancelled. The examination can
be performed, for example, using Maddox test.
Associated heterophoria or the angular deviation of the fixation is a condition where the
eyes in the deflected position fix, there is the presence of fusion and fusion stimulus. The
examination can be carried out using the methods of MKH and Mallet test.
VII. CSKO 20. 10. 2016
196
Picture 19: Mallet test
Determining prismatic correction
Diagnosis of heterophoria is possible after the abolition of the fusion stimulus (e.g.
covering one eye, the mechanical division of the visual perception of the right and left eye, a
red-green tests). If we use the central or peripheral fusion stimulus we diagnose and measure
fixation disparity.
Examination of heterophoria should begin with the cover test, we are able to find
heterophoria by rapid alternation of a shell plate, and observing the not covered eye.
Maddox test consists of Maddox cross with a point light and Maddox plate glass with
lines, which we put in front of one eye. On the cross, there we can directly determine the size
and direction of the deviations (i.e. distance of displacement of the line induced by the point
light across the plate).
Bagolini glass are glass with striations under the angles of 135° and 45°, after their
submission in front of both eyes occurs to the variance of the point light source into two lines
perpendicular to the direction of the striations.
Schober and Worth tests are anaglyphic tests that can be used for the investigation of
into the distance and into close range.
Method MKH (Measuring and Correction Method According Haase) as part of polatest
is the latest method of measurement of the heterophoria and fixation disparity. It contains
several tests, when only the K-test is convincing heterophoria and its motoric part, other tests
such as dial (R), hooked (H-test) stereotest (S) and stereovalence test (SV) used for diagnosis
and measurement of fixation disparity.
VII. CSKO 20. 10. 2016
197
Picture 20: Schober test, Maddox cross, Worthova test, MKH
Graef prism is a vertical prism of 6-8 pD, which is presented in front of one eye to the
creation the artificial diplopia. Therington’s variant is a modification to the distance and near
measuring, when through the prism 12 pD occurs to shift the arrow on the scale which shows
the size and direction of deviations.
Picture 21: Measuring of phorias
Most important is right correction of refractive defect. For example, the uncorrected
hyperopia will have a tendency to esophoria, myopia contrary to exophoria. We can also use
ortoptic training on haploscope device - troposcope, synoptophore. We can train the opposite
width of the fusion (we train negative fusion reserves – divergence in esophoria).
Prescription of prismatic correction is governed by several rules:
Maddox’s rule – esophoria above 3 pD correct by 50%, exophoria over the 2 pD by 60%
and vertical deviations by 80-100%
Sheard’s criterion - opposite-oriented width of fusion must be higher than twice of the
value of heterophoria, in order to avoid asthenopic disorders: OOF ≥ 2 x HTF
Percival's criterion - prismatic effect according to the formula: ∆ = 1/3 HFR- 2/3 LFR,
where HFR is higher fusion reserve and LFR lower fusion reserve
MKH - the full measured correction.
VII. CSKO 20. 10. 2016
198
Rutrle recommended to start correcting by using prismatic lenses 1 pD in the
horizontal direction, for deviation in the vertical direction is 0.5 pD. On the 4 pD, there
should be a shift in relation to point about 1 mm against the direction of the base.
Unwanted effects of prismatic correction are most often a distortion of perception,
chromatic aberration, macropsia or micropsia (zoom in or out of the observed object).
Wearers may complain of headaches and pain of the eye, there is a longer period of
habituation.
Conclusion
This text is only a brief summary of the essential points in the diagnosis and correction
of heterophoria by prismatic correction. There isn’t everything that can characterized
prismatic correction. The application of prismatic correction is a very individual matter and it
is necessary to each client approached with individual care. The thesis "Conditions for the
success of the prescription of the prismatic correction" will not, therefore, serve as a guide for
the prescription of the prismatic correction. Rather it will be by mapping the most highly used
methods of diagnostics and correction of heterophoria across the Czech Republic. The thesis
will provide information on the most relevant methods, rules, regulations and for example,
the orders of the prismatic lenses depends on success rate and contentment of the wearers.
Resources
Hromádková, L. Šilhání. 3. nezměněné vyd. Brno: Národní centrum ošetřovatelství a
nelékařských zdravotnických oborů, 2011. str. 162. ISBN 978-80-7013-530-3.
Divišová, G. Strabismus. 2. vydání. Praha: AVICENUM, 1990. 312 s. ISBN 08-039-90.
Veselý, P. Využití Polatestu v praxi optometristy. 2007.
Jexová, S. Geometrická optika. Vyd. 1. Brno: Národní centrum ošetřovatelství a nelékařských
zdravotnických oborů, 2010. str. 218. ISBN 978-80-7013-521-1.
Najman, L. Prizmatická korekce. Česká oční optika. Brno: Společenstvo českých optiků a
optometristů, listopad 2012, č. 4/2012, roč. 53, stránky 30-34. ISSN 1211-233X.
Schwendtová, V., Brunner, R. Geometrická a pristrojová optika. [1.vyd.]. Martin: Osveta, 1998.
str. 292. ISBN 978-80-2170-523-4.
Rutrle, M. Binokulární korekce na polatestu. Vydání: první. Brno: Institut pro další vzdělávání
pracovníků ve zdravotnictví, 2000. str. 115. ISBN 80-7013-302-3.
VII. CSKO 20. 10. 2016
199
Změny endotelových buněk rohovky a nitrooční tekutiny po
operaci katarakty fakoemulzifikací a za asistence
femtosekundového laseru.
Autor: Bc. Kateřina Pavlíčková
Školitel: Doc. MUDr. Šárka Pitrová, CSc., FEBO
Abstrakt
Cílem této studie je zjistit, jak laser, používaný při operaci katarakty, ovlivňuje tkáně
rohovky. Pacienti jsou rozděleni do dvou skupin podle podstoupené techniky operace
katarakty. První skupinu tvoří pacienti operovaní manuální technikou, druhou skupinu tvoří
pacienti operovaní za asistence femtosekundového laseru. Jsou porovnávány výsledky obou
skupin z předoperačního a pooperačního vyšetření rohovkového endotelu a pH nitrooční
tekutiny. Měření pH nitrooční tekutiny je prováděno pomocí vláknového senzoru založeného
na detekci fluorescence závislé na pH.
Úvod
Katarakta je definována jako zkalení čočky, což způsobuje snížení zrakové ostrosti.
Katarakta je nejčastější příčinou slepoty a její operace je světově nejčastěji prováděným
chirurgickým zákrokem. Její výskyt roste s věkem. Jedinou možnou léčbou je chirurgické
odstranění zkalené čočky a její nahrazení umělou nitrooční čočkou. [1, 2]
Ve vyspělých zemích je nejčastěji používanou metodou operace fakoemulsifikace. Pro
rozdělení zkalené čočky je využito ultrazvuku. [3]
Manuální chirurgické nástroje, používané pro tvorbu incizí a v dalších krocích operace,
mohou být částečně nahrazeny technologií femtosekundového laseru. Jejím cílem je zvýšení
přesnosti a bezpečnosti zákroku. I zde je však riziko vedlejších účinků. [2, 4]
Femtosekundovým laserem asistovaná operace katarakty využívá mechanismu
fotodisrupce pro tvorbu incizí, k otevření předního pouzdra čočky a pro fragmentaci čočky.
VII. CSKO 20. 10. 2016
200
Obr. 1: Mechanismus fotodisrupce. A absorpce energie laseru, B formování
plasmatu a kavitačních bublin, C expanze plynu a oddělení tkáně. [2]
Energie femtosekundového laseru je absorbována tkání, což vede k formování
plasmatu. Plasma rychle expanduje a tvoří se kavitační bubliny. Jejich silou dochází k oddělení
tkáně. Plynové kavitační bubliny, které jsou viditelné při laserové proceduře, mohou způsobit
změnu pH nitrooční tekutiny, což může ovlivnit tkáně oka. [2, 4]
Cílem této studie je zjistit, jak laser používaný při operaci katarakty ovlivňuje tkáně
rohovky, zvláště rohovkový endotel
Metodika
Tato studie se skládá ze dvou částí a to z analýzy počtu a morfologie buněk rohovkového
endotelu a z měření pH nitrooční tekutiny. Pacienti jsou rozděleni do dvou skupin podle
podstoupené techniky operace katarakty. První skupinu tvoří pacienti operovaní manuální
technikou, druhou skupinu tvoří pacienti operovaní za asistence femtosekundového laseru
s využitím platformy Victus.
VII. CSKO 20. 10. 2016
201
Obr. 2: Femtosecond laser platform Victus (TECHNOLAS Perfect Vision)
Obr. 3: Femtosecond laser platform Victus, vizualizace incizí. Na fotografii
jsou viditelné kavitační plynové bubliny.
Analýza buněk rohovkového endotelu
Rohovkový endotel je tvořen jednou vrstvou buněk pokrývajících vnitřní plochu rohovky.
[1, 3]
Analýza buněk rohovkového endotelu se bude skládat z předoperačních a několika
pooperačních vyšetření. Vyšetření probíhají na privátní Oční klinice Jana Leštáka, s.r.o. pomocí
KONANA MEDICAL CELL CHEK XL Clinical Specular Microscope. Jedná se o endotelový
mikroskop, jehož software provádí analýzu počtu a morfologie buněk endotelu. Výstup
z vyšetření je uveden na obrázcích 4 a 5.
VII. CSKO 20. 10. 2016
202
Obr. 4: Analýza endotelových buněk. CD – počet buněk na milimetr čtvereční,
CV – koeficient variace, HEX – procentuálnípočet hexagonálních buněk,NUM
– počet buněk použitých pro kalkulaci, PACHY – tloušťka rohovky.
Obr. 5: Analýza endotelových buněk. Vizualizace a zvýraznění obrysů buněk.
Měření pH nitrooční tekutiny
Nitrooční tekutiny vyplňuje přední a zadní komoru oka. Fyziologické pH se pohybuje
v rozmezí od 7,3 do 7,6. V průběhu forodisrupce tkáně může být pH nitrooční tekutiny
ovlivněno přeměnou oxidu uhličitého CO2 ,v kavitačních bublinách, na kyselinu uhličitou
H2CO3. To vede ke snížení pH nitrooční tekutiny. [4]
Vzorky nitrooční tekutiny o objemu přibližně 0,1 ml jsou odebírány po laserové
proceduře, u pacientů operovaných za asistence femtosekundového laseru, a před tvorbou
incizí u pacientů operovaných manuální technikou.
VII. CSKO 20. 10. 2016
203
Obr. 6: Odběr vzorku nitrooční tekutiny
První vzorky byly měřeny v Ústavu fotoniky a elektroniny AV ČR, v. v. i. pomocí
vláknového senzoru pro měření pH. Průměr optického vlákna byl snížen z konvenčních 125
μm na 20 μm a sonda byla pokryta pH-senzitivní vrstvou. Tento senzor je založen na
fluorescenčním pH-senzitivním barvivu (iontový pár HPTS a CTAB). [5, 6]
Obr. 7: Hrot vláknového senzoru. [6]
Jako excitační zdroj jsou použity laserové diody emitujícína 405 nm a 450 nm. Emitované
světlo je následně sbíráno ve zpětném směru optického vlákna. [5]
Obr. 8: Schéma měřícího přítroje. [5, 6]
Odpověď senzoru byla vyhodnocena jako poměr R (1) intenzit fluorescence při excitaci
při 450 nm a 405 nm.
𝑅 =
𝐼450
𝐼405
(1)
Tento poměr byl pro výpočet pH porovnán a kalibrační křivkou, která byla vytvořena po
proměření pufrů.
VII. CSKO 20. 10. 2016
204
Obr. 9: Kalibrační křivka a rovnice
Výsledky a diskuse
Analýza buněk rohovkového endotelu
Byla provedena první předoperační vyšetření u obou skupin pacientů. V dalším kroku
studie budou data z předoperačních vyšetření doplněna o data z pooperačních vyšetření.
Výpovědní hodnota výsledků bude vyhodnocena podle odchylky měření, která byla určena
opakovaným měřením jednoho konkrétního oka.
Cells/mm2 Cells/mm2
1 3040 8 3086
2 3115 9 3155
3 3003 10 3106
4 3077 11 3115
5 3205 12 3012
6 3125 13 3040
7 3058 14 3096
Arithmetic mean 3088
Standard deviation 53.5
Coefficient of variation (%) 1.73
Tab. 1: Stanovení odchylky měření
Měření pH nitrooční tekutiny
Pilotní skupina vzorků byla proměřena na Ústavu fotoniky a elektroniky. Výsledky jsou
uvedeny v následující tabulce 2.
Patient number pH Technique of the operation
1 7.59 manual technique
2 7.51 manual technique
3 7.60 manual technique
4 7.66 manual technique
5 7.65 manual technique
6 7.66 femtosecond laser
7 7.29 manual technique
8 7.49 femtosecond laser
Tab. 2: Měření pH nitrooční tekutiny
y = 0,4137x - 1,8472
0
0,25
0,5
0,75
1
1,25
1,5
5,5 6 6,5 7 7,5
R
pH
Calibration
VII. CSKO 20. 10. 2016
205
Cílem této studie bylo ověření metodologie analýzy endotelových buněk a měření pH
nitrooční tekutiny. Vzorky nitrooční tekutiny nebyly měřeny ihned po jejich odběru, proto
pravděpodobně nejsou výsledky přesné.
Závěr
V této práci byla demonstrována metodologie a první výsledky naší studie. Cílem je určit,
jak laser, používaný při operaci katarakty, ovlivňuje tkáně rohovky. Dokázali jsme vhodnost
zvolené metodiky. Dalším krokem studie bude doplnění dat z předoperačních vyšetření o data
z pooperačních vyšetření rohovkového endotelu. Pro dosažení přesných výsledků bude
měření pH nitrooční tekutiny prováděno ihned po odběru vzorku.
Poděkování
Tato práce vznikla za podpory Fakulty biomedicínského inženýrství Českého vysokého
učení technického, jmenovitě doc. Ing. Marie Pospíšilové, CSc. a prof. MUDr. Blanky Brůnové,
DrSc, dále za podpory Oční kliniky Jana Leštáka, s.r.o. a Ústavu fotoniky a elektroniky,
jmenovitě Ing. Ondřeje Podrazkého, Ph.D.
Zdroje
[1] Kuchynka, P. Oční lékařství. 1. vyd. Praha: Grada, 2007. ISBN 978-802-4711-638.
[2] Donaldson, K. E. ©1986–. Femtosecond laser–assisted cataract surgery. Journal of cataract
and refractive surgery. Fairfax, Va.: American Society of Cataract and Refractive Surgery,
November 2013(39).DOI: dx.doi.org/10.1016/j.jcrs.2013.09.002. ISSN 0886–3350. Available
from:
http://www.ascrs.org/sites/default/files/resresour/Femtosecond%20Cataract%20SurgerS%2
0Review_0.pdf
[3] Rozsíval, P. 2006. Oční lékařství. Vyd. 1. Praha: Karolinum, 373 s. ISBN 8072624040.
[4]Rossi, M., Censo, F. D., Censo, M. D., Oom, M. A. Changes in Aqueous Humor pH After
Femtosecond Laser-Assisted Cataract Surgery. Journal of Refractive Surgery [online].
2015, 31(7): 462-465. DOI: 10.3928/1081597x-20150623-04.
[5] Baldini, F., Homola, J., Lieberman, R. A., Podrazký, O., Mrázek, J., Vytykáčová, S.,
Proboštová, J., Kašík, I. Fiber optic pH sensing system with microscopic spatial resolution. DOI:
10.1117/12.2179471. ISBN 10.1117/12.2179471. Available from:
http://proceedings.spiedigitallibrary.org/proceeding.aspx?doi=10.1117/12.2179471
[6] Kašík, I., Podrazký, O., Mrázek, J., Martan, T., Matějec, V., Hoyerová, K., Kamínek, M. In vivo
optical detection of pH in microscopic tissue samples of Arabidopsis thaliana. Materials
Science and Engineering: C. 2013, 33(8), 4809-4815. DOI: 10.1016/j.msec.2013.07.045. ISSN
09284931. Dostupné také z: http://linkinghub.elsevier.com/retrieve/pii/S092849311300461X
VII. CSKO 20. 10. 2016
206
Changing of corneal endothelial cells and aqueous humor
after cataract surgery using phacoemulsification and
femtosecond laser-assisted procedure
Author: Bc. Kateřina Pavlíčková
Supervisor: Doc. MUDr. Šárka Pitrová, CSc., FEBO
Abstract
The aim of the study is to determine, how the laser, used in cataract surgery, affects the
tissue of the cornea. Patients are divided into two groups, according to different undertaken
technique of the operation. In the first group are patients, who were operated by manual
technique of cataract surgery. In the second group are patients, who were operated by
femtosecond laser-assisted cataract surgery. We will compare results of preoperative and
postoperative endothelial microscopy and pH of aqueous humor in both groups.
Measurement of pH of aqueous humor is realized by fiber-optic probes based on detection of
fluorescence, which depends on pH.
Introduction
Cataract is defined as any opacity of the lens in the eye. It leads to a decrease in visual
acuity. Cataract is the most common cause of blindness and cataract surgery is the most
commonly performed surgical procedure in the world. Cataracts become more common with
age. The only possible treatment of cataract is surgical remove opaque lens and implant
artificial intraocular lens. [1, 2]
Phacoemulsification is the most widely used cataract surgery in the developed world.
This procedure uses ultrasonic energy to emulsify the cataract lens. [3]
Manual surgical instruments, which are used for creating incisions and other steps of
procedure, may be partly substituted by femtosecond laser technology. Aim of this technology
is to improve safety and accuracy. However it has also disadvantages in side effects. [2, 4]
Femtosecond–laser assisted cataract surgery uses mechanism of phorodisruption for
creating incisions, for opening the anterior lens capsule and for lens fragmentation.
Femtosecond laser energy is absorbed by the tissue, resulting in plasma formation. This
plasma rapidly expands, creating cavitation bubbles. The force of the cavitation bubble
separates the tissue. Cavitation gas bubbles, visible during laser procedure, may cause
changes in pH of the aqueous humor, which may affect other tissues of the eye. [2, 4]
VII. CSKO 20. 10. 2016
207
Picture 1: Mechanism of Phorodisruption, A laser energy absorption, B
plasma and cavitation bubbles formation, C gas expansion and tissue
separation [2]
The aim of the study is to determine, how the laser, used in cataract surgery, affects the
tissue of the cornea, especially corneal endothelium.
Materials and methods
This study consists of two parts, analysis of the number and morphology of corneal
endothelial cells and aqueous humor pH measurement. Patients are divided into two groups,
according to different undertaken technique of the operation. In the first group are patients,
who were operated by manual technique of cataract surgery. In the second group are patients,
who were operated by femtosecond laser-assisted cataract surgery using femtosecond laser
platform Victus.
VII. CSKO 20. 10. 2016
208
Picture 2: Femtosecond laser platform Victus (TECHNOLAS Perfect Vision)
Picture 3: Femtosecond laser platform Victus, visualisation of incisions.
Cavitation gas bubbles are visible.
Analysis of endothelial cells
Endothelium is a single layer of cells and covers inner surface of the cornea. Endothelium
does not regenerate. [1, 3]
Analysis of corneal endothelial cells will consist of preoperative and several
postoperative examinations (after 1 week, 1 month). Examinations are performed at the
Private Eye clinic JL, s.r.o. in Prague on KONANA MEDICAL CELL CHEK XL Clinical Specular
Microscope. Appliance takes photo of endothelium and software performs analysis of number
and morphology of endothelial cells. Output from examination is shown at Figure 4 and Figure
5.
Picture 4: Analysis of endothelial cells. CD-number of cells per square
millimetre, CV- coefficient of variation, HEX- percentage of hexagon (six-side)
cells, NUM- number of cells used for calculation, PACHY- corneal thickness.
VII. CSKO 20. 10. 2016
209
Picture 5: Analysis of endothelial cells. Visualization and highlighting of cells
outline.
Aqueous humor pH measurement
Aqueous humor is liquid, which fills the anterior and posterior chamber of the eye.
Physiological pH ranges from 7.3 to 7.6 and may be affected during photodisruption by
transformation of carbon dioxide CO2 to carbonic acid H2CO3. It leads to an acid shift of the
aqueous humor pH. [4]
Samples of 0.1 mL of aqueous humor are collected after laser procedure, in
femtosecond-laser group, and before incision are made in the phacoemulsification group.
Picture 6: Aqueous humor sample collection
First samples were measured in the Institute of Photonics and Electronics of the CAS in
dislocated laboratory in Prague Suchdol by fiber-optic pH detection. The diameter of the
optical fibers was reduced from the conventional 125 μm to 20 μm and tapered-fiber probes
were coated by the sensing layers. The sensor is based on fluorescent pH-sensitive dye - an
ion pair of 8hydroxypyrrene-1,3,6-pyrene trisulfonic acid trisodium salt (HPTS) and
hexadecyltrimethylammonium bromide (CTAB) immobilized on the tip of tapered-fiber
probes. [5, 6]
VII. CSKO 20. 10. 2016
210
Picture 7: Tapered-fiber probe tip [6]
Laser diodes, emitting at 405 nm and 450 nm are used as excitation sources. Emitted
light is collected in a back-direction by the optical fiber probe. [5]
Picture 8: Scheme of the measurement instrument. [5, 6]
Response of the probe was evaluated as a ratio R (1) of fluorescence intensities for
excitation at 450 nm and 405 nm respectively. [5]
𝑅 =
𝐼450
𝐼405
(1)
Ratio R was compared with the calibration, compiled by buffer measurement, for
calculating the pH value.
Picture 9: Calibration curve and equation
y = 0,4137x - 1,8472
0
0,25
0,5
0,75
1
1,25
1,5
5,5 6 6,5 7 7,5
R
pH
Calibration
VII. CSKO 20. 10. 2016
211
Results and discusion
Analysis of endothelial cells
First preoperative examinations were performed in both groups of patients. Data will be
completed with postoperative examinations in next step of this study. Predictive value of the
results will be evaluated according to measurement of deviation.
Cells/mm2 Cells/mm2
1 3040 8 3086
2 3115 9 3155
3 3003 10 3106
4 3077 11 3115
5 3205 12 3012
6 3125 13 3040
7 3058 14 3096
Arithmetic mean 3088
Standard deviation 53.5
Coefficient of variation (%) 1.73
Chart 1: Measurement of deviation
Aqueous humor pH measurement
Pilot group of samples of aqueous humor were measured in Institute of Photonics and
Electronics.
Patient number pH Technique of the operation
1 7.59 manual technique
2 7.51 manual technique
3 7.60 manual technique
4 7.66 manual technique
5 7.65 manual technique
6 7.66 femtosecond laser
7 7.29 manual technique
8 7.49 femtosecond laser
Chart 2: Aqueous humor pH measurement
The aim of the study was to verify methodology of endothelial cells and aqueous humor
pH measurements. The pH samples were not measured immediately after their collecting and
therefore our results are probably not correct.
Conclusions
In this paper we have demonstrated methodology and the first results of our study. The
aim was to determine, how the laser, used in cataract surgery, affects the tissue of the cornea.
We have proved that the chosen methodology is appropriate for measurement of
aqueous humor pH and for analysis of endothelial cells.
VII. CSKO 20. 10. 2016
212
Next step of this study will be concern on summarize of preoperative and postoperative
data from examinations of endothelial cells. Measurement of pH will be performed
immediately after sample collecting to achieve exact results.
Acknowledgements
This work was supported by Czech Technical University’s foundation SVK 46/15/F7, Eye
clinic of Jan Lešták and by Institute of Photonics and Electronics of the CAS
Resources
[1] Kuchynka, P. Oční lékařství. 1.vyd. Praha: Grada, 2007. ISBN 978-802-4711-638.
[2] Donaldson, K. E. ©1986–. Femtosecond laser–assisted cataract surgery. Journal of cataract
and refractive surgery. Fairfax, Va.: American Society of Cataract and Refractive Surgery,
November 2013(39).DOI: dx.doi.org/10.1016/j.jcrs.2013.09.002. ISSN 0886–3350. Available
from:
http://www.ascrs.org/sites/default/files/resresour/Femtosecond%20Cataract%20SurgerS%2
0Review_0.pdf
[3] Rozsíval, P. 2006. Oční lékařství. Vyd. 1. Praha: Karolinum, 373 s. ISBN 8072624040.
[4] Rossi, M., Censo, F. D., Censo, M. D., Oom, M. A. Changes in Aqueous Humor pH After
Femtosecond Laser-Assisted Cataract Surgery. Journal of Refractive Surgery [online].
2015, 31(7): 462-465. DOI: 10.3928/1081597x-20150623-04.
[5] Baldini, F., Homola, J., Lieberman, R. A., Podrazký, O., Mrázek, J., Vytykáčová, S.,
Proboštová, J., Kašík, I. Fiber optic pH sensing system with microscopic spatial resolution. DOI:
10.1117/12.2179471. ISBN 10.1117/12.2179471. Available from:
http://proceedings.spiedigitallibrary.org/proceeding.aspx?doi=10.1117/12.2179471
[6] Kašík, I., Podrazký, O., Mrázek, J., Martan, T., Matějec, V., Hoyerová, K., Kamínek, M. In vivo
optical detection of pH in microscopic tissue samples of Arabidopsis thaliana. Materials
Science and Engineering: C. 2013, 33(8), 4809-4815. DOI: 10.1016/j.msec.2013.07.045. ISSN
09284931. Dostupné také z: http://linkinghub.elsevier.com/retrieve/pii/S092849311300461X
VII. CSKO 20. 10. 2016
213
Symetrická a asymetrická konvergence
Autor: Bc. Nikola Repková
Školitel: Mgr. Matěj Skrbek
Úvod
Konvergence je stáčení obou bulbů směrem dovnitř a velmi úzce je spojena s akomodací.
Když se díváme na blízký předmět, osy obou očí se sbíhají tak, aby paprsek dopadl na žluté
skvrny obou očí.
Konvergenci umožňují zevní oční svaly. Jedná se vlastně o disjunktní souhyby očí, které
umožňují změnu fixační vzdálenosti i pozorovací úhel. Reflex konvergence se vyvíjí kolem 5. až
6. měsíce života dítěte.
Konvergence se uskutečňuje skrze motorickou fúzi, to znamená, že se oči pohybují tak,
aby se zrakové osy zaměřily na sledovaný objekt. Pokud se tak stane, může nastat senzorická
fúze, která umožňuje sloučit dva stejné nebo téměř stejné sítnicové obrazy so jednoho
binokulárního vjemu.
Konvergenci většinou udáváme pomocí jednotky prizmatická dioptrie. Jednu
prizmatickou dioptrii definujeme jako odchylku očí o jeden centimetr od přímého směru na
vzdálenost jeden metr. Z toho můžeme odvodit, že úhel konvergence obou očí udaný
v prizmatických dioptriích odpovídá pupilární vzdálenosti udané v centimetrech vydělené
pozorovací vzdálenosti v metrech. Jestliže potřebujeme popsat konvergenci pouze jednoho
oka (což při zjišťování asymetrické konvergence potřebujeme), musíme udávat poloviční
hodnotu pupilární vzdálenosti.
Stejně jako má akomodace blízký bod, tak má i konvergence blízký bod (near point of
convergence, NPC). Je to nejmenší vzdálenost předmětu nacházejícího se před okem, kdy ještě
tento předmět vidíme jednoduše. Nebývá stejně velký jako blízký bod akomodace a také se
v průběhu života příliš nemění. Ve 40. roce života bývá většinou vzdálen asi 8 centimetrů od
kořene nosu a ve 20 letech asi 5 centimetrů. Pokud je blízký bod konvergence větší než deset
centimetrů, je konvergence nedostatečná. Konvergenční oblast je prostor mezi blízkým a
dalekým bodem konvergence.
Složky konvergence
Dle Maddoxe dělíme konvergenci do dvou skupin – konvergenci volní, kterou můžeme
vyvolat našim úsilím, a konvergenci reflexní, u které rozlišujeme čtyři složky: konvergence
tonická, konvergence akomodační, konvergence fúzní a konvergence proximální.
Tonická konvergence je popisována jako pohyb očí z divergence, tedy klidové
anatomické pozice, do více konvergenční pozice. Jestliže je tonická konvergence
nedostatečná, může se projevovat exoforie. Naopak jestliže je tonická konvergence
nadměrná, může se projevovat esoforie.
VII. CSKO 20. 10. 2016
214
Akomodační konvergence je konvergence způsobená akomodací. Většinou ji udáváme
pomocí AC/A poměru, který by měl být 1:3.
Proximální neboli psychická konvergence se uskutečňuje vědomím blízkého předmětu.
Fúzní konvergence tzv. dorovnává oční osy, aby obraz předmětu dopadal na fovey sítnic
a pozorovaný předmět byl viděn jednoduše. Jejím stimulem bývá disparátní zobrazení.
Asymetrická konvergence
Jestliže je pozorovaný předmět ve střední rovině, mluvíme o symetrické konvergenci.
Pokud leží pozorovaný předmět mimo střední rovinu, mluvíme o asymetrické konvergenci.
Asymetrickou konvergenci užíváme běžně – například při změně fixace ze vzdálenějšího
předmětu přímo vepředu na blízký objekt, který je umístěný na straně.
Asymetrická konvergence se velmi často objevuje u divergentního strabismu. Lze ho
očekávat i u osob esofórií či exoforií do blízka.
Obr. 1: Asymetrická konvergence
Anomálie konvergence
Insuficientní (nedostatečná) konvergence
Projevuje se velkou exoforií na blízké předměty, přitom jsou oči při pohledu do dálky
rovnoběžné nebo mají pouze malou exoforii.
Excesivní (nadměrná) konvergence
Jedná se o velmi zřejmou esoforii na blízko, při pohledu do dálky jsou oči rovnoběžné.
Nacházíme ji u překorigované myopie, nekorigované hypermetropie nebo po aplikaci
cykloplegik. Odstraníme ji správnou korekcí.
Insuficientní (nedostatečná) divergence
U insuficience divergence rozlišujeme mezi primární insuficiencí, která se projevuje
značnou esoforií na dálku a malou esoforií na blízko, a sekundární insuficiencí divergencí, u
které je typicky větší esoforie na blízko než na dálku.
Excesivní (nadměrná) divergence
U excesu divergence se nachází exoforie na dálku a stejná nebo menší exoforie do blízka.
VII. CSKO 20. 10. 2016
215
Paralýza konvergence
Obrnou konvergence je označováno sekundární onemocnění poruchy mozku, nesmíme
jej zaměnit s oslabením konvergence. Projevuje se akutním začátkem potíží, velmi zřetelnou
exotropií do blízka, přitom jsou oči do dálky paralelní. Pacient není schopen konvergovat,
akomodace není narušena, ale pacient trpí diplopií při fixaci do blízka. Při podezření na
paralýzu konvergence je nutné provést tyto vyšetření: zakrývací test do blízka i do dálky,
velikost blízkého bodu konvergence i akomodace, zjišťujeme oční motilitu a poté odešleme
pacienta na neurologické vyšetření, kde zjistí a pokud možno vyléčí neurologickou poruchu.
Obrna konvergence se napravuje správnou korekcí refrakční vady, cvičením konvergence,
můžeme využít ortoptických cvičení nebo můžeme pacientovi předepsat prizmatickou korekci.
Vyšetření konvergence
Subjektivní měření NPC
Toto měření je založené na rozdvojení obrazu. Pacient za vzdálenosti 50 cm pozoruje
například hrot propisky, kterou postupně posouváme směrem k nosu, jakmile se pacientovi
hrot rozdvojí, našli jsme bod rozdvojení. Poznamenáme si jeho hodnotu v centimetrech.
Potom začneme propiskou posunovat opačným směrem, tedy od nosu. Jakmile se pacientovi
hrot propisky opět spojí v jeden, získali jsme bod spojení. Hodnoty rozdvojení a spojení
zapisujeme do zlomku (v cm). Bod rozdvojení nabývající hodnot 7,5 cm a méně považujeme
za fyziologický. Fyziologické hodnoty u bodu spojení by měly dosahovat velikosti 10,5 cm a
méně.
Objektivní měření NPC
Objektivní blízký bod konvergence je bod, kde přestane jedno oko fixovat. Při tomto
testu také posouváme propisku směrem k nosu a přitom sledujeme oko vyšetřovaného – tedy
v jaké vzdálenosti propisky od nosu se oko vytočilo ven.
Měření pozitivní fúzní rezervy
U tohoto vyšetření pacient sleduje písmeno ve vzdálenosti 6 metrů a poté ze 40
centimetrů, následně předkládáme před jedno oko, pomocí prizmatické lišty, prizma.
Poznačíme si velikost prizmatu, kdy se pacientovi písmeno zamlžilo (blur point), poté kdy se
pacientovi písmeno rozdvojilo (break point) a jak poslední si poznačíme, kdy se pacientovi
písmeno opět spojilo (recovery point). Fyziologické hodnoty break pointu do dálky by měly být
18 – 22 pD a do blízka 26 – 34 pD.
Závěr
Vergenční oční pohyby, konvergence a divergence, jsou důležité pro správné binokulární
vidění. Jestliže je funkce konvergence nějakým způsobem narušena, může způsobovat např.
astenopické potíže, působit esoforii či exoforii, popřípadě diplopii. Problémy s konvergencí
mohou být indikátorem jiných očních onemocnění, a proto je důležité pečlivě sledovat její
vývoj, abychom mohli včas začít s korekcí vady a nácvikem správné konvergence.
VII. CSKO 20. 10. 2016
216
Zdroje
Jeřábková, A. Insuficience konvergence. Česká oční optika. 2013, 2013(3), 32-33.
Šinoglová, P. Inkonkomitantní strabizmus a jeho řešení v optometrii. Česká oční optika.
2015,2015(2), 46-50.
Randulová, J. Akomodace a konvergence. Brno, 2008. Bakalářská práce.
Přehnalová, M. Vergence a akomodace. Olomouc, 2011. Bakalářská práce.
Kollegová, H. Poruchy konvergence a divergence. Měření blízkého bodu konvergence. Brno,
2012. Diplomová práce.
Končáková, L. Strabismus u dospělé populace. Brno, 2007. Diplomová práce.
Tamler, E., Jampolsky, A., Marg, E. An Electromyographic Study of asymmetric convergence.
1958, 1958, 174-182.
Lešinská,L. Synoptofor - možnostivyšetřenía jeho vyhodnocení. Brno, 2011. Bakalářská práce.
Horká, D. Strabismus. Brno, 2007. Bakalářská práce.
VII. CSKO 20. 10. 2016
217
Symmetric and asymmetric convergence
Author: Bc. Nikola Repková
Supervision: Mgr. Matěj Skrbek
Introduction
Convergence is racking of both eyeballs inwards and closely associated with
accommodation. When we look at close objects axes of both eyes converge so that the beam
struck the macula of both eyes.
Convergence lets external eye muscles. This is actually a disjoint souhyby eyes that allow
changing the fixation distance and viewing angle. Reflex convergence evolves around 5 to 6
months after birth.
Convergence is effected through a motor fusion, ie. the eyes move so that the visual axis
focused on object tracking. If that happens, there may be sensory fusion, which allows you to
merge two are almost the same retinal images of a binocular perception.
Convergence usually specified by using the unit prism diopters. One prism diopter is
defined as a deviation of the eyes of one centimeter from a straight line over a distance of one
meter. From this we can deduce that the angle of convergence of the two eyes given in
prismatic diopters corresponds pupillary distances given in centimeters divided by the viewing
distance in meters. If we need to describe the convergence of only one eye (which in detecting
asymmetric convergence needed) should give half the value of the pupillary distance.
Like a near point of accommodation, and has a near point of convergence (near point of
convergence, NPC). It is the smallest distance of the object located in front of the eye, yet
when this subject see easily. It is not as big as the near point of accommodation and also
throughout their lives have not changed much. In the 40th year of life it is usually located
about 8 centimeters from the base of the nose and at 20 years of about 5 centimeters. If the
near point of convergence larger than ten centimeters convergence is insufficient.
Convergence zone is the space between the near and distant point of convergence.
Ingredients convergence
According to Maddox convergence divided into two groups - voluntary convergence,
which may cause our effort and convergence reflex, in which there are four components: tonic
convergence, accommodative convergence, convergence and fusion of the proximal
convergence.
Tonic convergence is described as eye movements of divergence, ie the rest of
anatomical position to more convergence position. If the tonic convergence insufficient, it
may appear exoforie. Conversely, if a tonic convergence excessive, it may appear esoforie.
Accommodative convergence, convergence is caused by accommodation. Usually we
specified by using the AC / A ratio, which should be 1: 3rd
Proximal or psychical convergence takes place near object consciousness.
The fusion of so-called convergence. Balances the eye axis to image the subject turned
to the retina, the fovea observed object was seen easily. Its stimulus is disparate views.
VII. CSKO 20. 10. 2016
218
Asymmetric convergence
If the observed object is in the middle plane, talking about symmetrical convergence. If
the observed object is located outside the central plane, talking about asymmetrical
convergence. Commonly used asymmetric convergence - for example, when changing the
fixation of the distant object directly in front on a nearby object, which is located on the side.
Asymmetric convergence often occurs in divergent strabismus. It can be expected in
people esoforia or exoforia near.
Picture 1: Asymmetric convergence
Anomalies convergence
Insufficiency (lack of) convergence
Manifested great exoforia on nearby objects, while the eyes looking into the distance
parallel or have only a small exoforia.
Excessive (over) convergence
This is a very obvious esoforia to close, looking into the distance, the eyes are parallel.
We find it in overcorrection of myopia, hyperopia, uncorrected or after application
cycloplegics. Remove it proper correction.
Insufficiency (lack of) divergence
For insufficiency divergence we distinguish between primary impairment, which is
manifested considerable esoforia distance and small esoforia to close, and secondary
insufficiency divergence in which is typically greater than esoforia at close distance.
Excessive (over) divergence
In excess of divergence is exoforia distance and equal to or less exoforia near.
Paralysis convergence
Paralysis of convergence is called secondary disease disorders of the brain, we must not
confuse it with the weakening of convergence. It manifests itself in early acute problems is
very clear exotropia near, yet they are the eyes into the distance parallel. The patient is unable
to converge, accommodation is not disturbed, but when the patient is suffering from diplopia
at near fixation. In suspected paralysis of convergence, it is necessary to perform these tests:
masking test for near and far away, the size of the near point of convergence and
accommodation, we find ocular motility, and then send the patient for neurological
examination, which determines if possible cure neurological disorder. Polio convergence
correction corrects correct refractive errors, convergence exercise, we can use orthoptic
exercise or the patient can be prescribed prismatic correction.
VII. CSKO 20. 10. 2016
219
Examination of convergence
Subjective measurements NPC
This measurement is based on the double images. Patients under 50 cm watching
example tip pens, which are moving gradually towards the nose when the patient spike split
in two, we found a point of bifurcation. Note the its value in centimeters. Then we begin to
pen move in the opposite direction, ie from the nose. Once the patient tip pens reunited at
one point we got the connection. Values bifurcation and links are written to a fraction (in cm).
Bifurcation point having a value 7.5 cm and less regard as physiological. Physiological values
at the point of connection should reach the size of 10.5 cm and less.
Objective measurements NPC
Objective near point of convergence is the point where one eye fixed stops. In this test
also pushing the stylus towards the nose while watching eye examined - ie how far pens from
nose to eye pissed out.
Measurement positive fusion reserves
In this examination of patient monitors, point at a distance of 6 meters and then from
40 cm, then present before one eye, using a prism sheet, prism. Make a mark the size of the
prism, when the patient letter blurred (blur point), after which the patient forked point (break
point) and how you last make a mark where the patient letter reunited (recovery point).
Normal values break point into the distance should be 18 to 22 PD at near 26-34 pD.
Conclusion
Convergent eye movements, convergence and divergence, are important for proper
binocular vision. If the function of the convergence somehow impaired, for example, may
cause asthenopic trouble, causing esoforia or exoforia or diplopia. Problems with convergence
may be an indicator of other eye diseases, so it is important to carefully monitor its
development, we can start early with correction of defects and practicing proper convergence.
Resources
Jeřábková, A. Insuficience konvergence. Česká oční optika. 2013, 2013(3), 32-33.
Šinoglová, P. Inkonkomitantní strabizmus a jeho řešení v optometrii. Česká oční optika.
2015,2015(2), 46-50.
Randulová, J. Akomodace a konvergence. Brno, 2008. Bakalářská práce.
Přehnalová, M. Vergence a akomodace. Olomouc, 2011. Bakalářská práce.
Kollegová, H. Poruchy konvergence a divergence. Měření blízkého bodu konvergence. Brno,
2012. Diplomová práce.
Končáková, L. Strabismus u dospělé populace. Brno, 2007. Diplomová práce.
Tamler, E., Jampolsky, A., Marg, E. An Electromyographic Study of asymmetric convergence.
1958, 1958, 174-182.
Lešinská, L. Synoptofor - možnostivyšetřenía jeho vyhodnocení. Brno, 2011. Bakalářská práce.
Horká, D. Strabismus. Brno, 2007. Bakalářská práce.
VII. CSKO 20. 10. 2016
220
Vliv anizometropie na kvalitu vidění
Autor: Bc. Eva Staffová
Školitel: Mgr. Petr Veselý, Dis., Ph.D.
Tato studie se zabývá subjektivním hodnocením projevů anizometropie a aniseikonie a
hledá subjektivní hranici binokulárního vidění u pacientů při navozené aniseikonii. Prozatím se
studie účastnilo 37 subjektů, průměrný věk byl 23 let. Pacienti dosáhli s vlastní korekcí nebo
po subjektivním vykorigování minimálně visu 1,0 a byli bez oční patologie a výrazné
anizometropie. Pomocí size lens byla pacientům navozena aniseikonie a formou dotazníku
byly zjišťovány subjektivní příznaky pacienta při čtení textu.
Nejzávažnějším projevem aniseikonie je dvojité vidění. V naší studii udávalo diplopii
pouze 30 % subjektů při navození 6% aniseikonie a necelých 60 % subjektů při aniseikonii 8 %.
Téměř 80 % probandů nepocítilo žádnou změnu při navození 2% aniseikonie. Nepříjemná
bolest oka byla většinou subjektů udávána až při navození aniseikonie od 6 %. Nejméně
zaznamenané symptomy byly: nevolnost, potíže se čtením a distorze.
Úvod
Jako anizometropii označujeme stav, kdy je přítomna rozdílná refrakce na obou očích.
Malý rozdíl v refrakci obou očí se vyskytuje poměrně často, absolutně stejný refrakční stav
obou očí je poměrně vzácný. Vlivem anizometropie dochází ke vzniku aniseikonie. Aniseikonie
znamená nestejnou velkost retinálních obrazů obou očí a může být příčinou zhoršené kvality
vidění.
Anizometropie
Anizometropii můžeme dělit z hlediska příčiny a z hlediska refrakčních vad. Z hlediska
příčiny dělíme anizometropii na refrakční (systémovou), kdy je délka obou očí stejná, ale je
přítomen rozdíl v optické mohutnosti lomivých prostředí oka a na axiální, kdy jsou optické
mohutnosti optických prostředí oka stejné, ale axiální délka očí je rozdílná. Může nastat
situace, kdy jsou přítomny oba dva typy a nastává anizometropie smíšená. Z hlediska
refrakčních vad rozdělujeme anizometropii na hypermetropickou, myopickou, astigmatickou
a smíšenou, kdy je jedno oko myopické a druhé hypermetropické. Dle výzkumu Trottera z roku
1967 se vyskytuje anizometropie do 1 D u 91% anizometropů, od 1 D až 1,75 D u 5% pacientů,
od 2 D až 2,7 5D u 2% pacientů a anizometropie vyšší než 3 D jen u 1,6% pacientů.
U korigované anizometropie nastávají tyto potíže: anizoforie, aniseikonie a boj o
optimální akomodaci mezi pravým a levým okem. Anizoforie nastává při pohledu přes okraj
brýlové čočky, z důvodu různé vrcholové lámavosti brýlových čoček působí na oči nestejný
prizmatický účinek. [1,3,5]
Aniseikonie
Aniseikonie je typickým projevem anizometropie. Jedná se o nestejnou velikost
retinálních obrazů pravého a levého oka. Aniseikonii můžeme rozdělovat na fyziologickou,
VII. CSKO 20. 10. 2016
221
která nastává vlivem asymetrické konvergence, dále na arteficiální (brýlovou), která vzniká
z důvodu rozdílné vrcholové lámavosti korekčních čoček a na anatomickou, která vzniká
z důvodu anatomických rozdílů na pravém a levém oku (například rozdílná axiální délka). Dále
můžeme aniseikonii dělit dle osy na horizontální, vertikální, šikmou a smíšenou.
Obrázek 22: Různé formy aniseikonie – dělení dle osy [1]
Vztah mezi anizometropií a aniseikonií je takový, že asi 0,5 D anizometropie znamená asi
1 % v rozdílu velikosti retinálních obrazů. Klinicky významná aniseikonie je od 2 % rozdílu
velikostí sítnicových obrazů pravého a levého oka, tedy 1 D anizometropie. Za hranici
binokulárního vidění je považována aniseikonie asi 5 %. Dle studie Bannona a Trillera z roku
1994 patří mezi charakteristické projevy aniseikonie: bolest hlavy, astenopie, fotofobie, obtíže
při čtení, nevolnost, diplopie, nervozita, závratě, malátnost, dezorientace. [1,4]
Soubor a metodika
Studie se prozatím zúčastnilo 37 subjektů, z toho 30 žen a 7 mužů. Průměrný věk byl 23
let (minimum 19 let, maximum 64 let, SD 9 let). Podmínkou účasti ve studii je dosažený visus
minimálně 1,0 na dálku, pacient bez oční patologie a výrazné anizometropie. Cílem této studie
je nalézt subjektivní hranici binokulárního vidění u pacientů bez anizometropie a zjistit
subjektivní příznaky při uměle navozené aniseikonii.
U každého pacienta byla na začátku ověřena hodnota zrakové ostrosti s vlastní korekcí,
pokud nebylo dosaženo visu 1,0 s vlastní korekcí, byl pacient dokorigován, aby bylo dosaženo
visu alespoň 1,0 na obou očích. Následně byla ověřena přítomnost aniseikonie pomocí
anaglyfního hákového testu a červenozeleného filtru. U žádného z pacientů nebyla zjištěna
přítomnost aniseikonie. Následovalo ověření zrakové ostrosti do blízka pomocí čtecího textu,
pacient musel přečíst řádek 0,8. Při fixaci textu byly pacientovi postupně předkládány size lens
před pravé oko. Hodnoty size lens byly 2 %, 4 %, 6 %, 8 %. Při každém předložení čočky byl
pacient vyzván, aby zvolený řádek textu přečetl a byl dotazován na otázky z dotazníku (viz
tabulka 1). Pacient byl dotazován, zda příznak vnímá či ne. Size lens byly předkládány od
nejnižší hodnoty po nejvyšší. Výsledky dotazníky byly zavedeny do tabulky Excel a zpracovány
pomoci Excel grafů. Při tvorbě dotazníku jsme se inspirovali studií Jasona Wilsnona, 2011 –
Measuring aniseikonia using filters to simulate cataract. [2,6]
VII. CSKO 20. 10. 2016
222
Tabulka 1: Dotazník ke studii
Obrázek 2: Dotazník ze studie Jasona Wilsona, 2011 – Measuring aniseikonia
using filters to simulate cataract [2]
VII. CSKO 20. 10. 2016
223
Výsledky
Odpovědi z dotazníku byly zaznamenány do Excel tabulek a vyhodnoceny pomocí grafů.
Každý graf je vytvořen pro určitý subjektivní symptom. Hodnotili jsme, jak velké procento
pacientů zaznamenalo určitý symptom při předložené hodnotě size lens. V souhrnném grafu
je zaznamenána velikost aniseikonie pro každý subjektivně pocítěný projev, který
zaznamenalo alespoň 50 % probandů. Z prvního grafu vyplývá, že pouze asi 20 % probandů
zaznamenalo změnu při aniseikonii 2 %. Při aniseikonii o hodnotě 4 %, která se blíží udávané
hranici binokulárního vidění, zaznamenalo změnu již přibližně 75% pacientů. Z uvedeného
grafu, tedy můžeme usoudit, že aniseikonie 4 % a více bude pro pacienta těžko snesitelná.
Graf 1: Velikost aniseikonie, při které pacient pocítl změnu
Z grafu 2 můžeme zjistit, jaké procento probandů pociťovalo při předložení size lens
nepříjemnou bolest, nebo tzv. tahání za oči. U 2% aniseikonie bolest udávalo pouze malé
procento lidí. Při předložení size lens o hodnotě 4 % zaznamenalo bolest očí téměř 40 %
subjektů. A při navození aniseikonie 6 % již zaznamenalo nepříjemné a bolestivé pocity asi 70
% probandů. Takové procento aniseikonie by tedy bylo pro většinu pacientů již neúnosné.
Graf 2: velikost aniseikonie, při které pacient pociťuje bolest oka
Další dotaz se týkal nevolnosti a motání hlavy. Pacient byl požádán, aby po předložení
size lens četl text a byl dotazován, zda se mu při čtení nedělá nevolno a jestli se mu nemotá
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
procentopacientů
Velikost aniseikonie v %
Pacient pociťuje změnu
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
procentopacientů
Velikost aniseikonie v %
Bolest oka/tahání za oči
VII. CSKO 20. 10. 2016
224
hlava. Z grafu 3 vidíme, že do 6% aniseikonie byl tento projev pacienty potvrzen pouze v malé
míře. Až v případě 8% aniseikonie udávalo nevolnost a motání hlavy téměř 50 % probandů.
Graf 3: Velikost aniseikonie, při které pacient udává nevolnost a motání hlavy
Graf 4 udává, jak velké procento probandů mělo při předkládání size lens potíže se
čtením. Při předložení size lens byl pacient dotázán, zda text dokáže přečíst a byl vyzván, aby
text přečetl. Situace, která byla zaznamenána do dotazníku jako problém se čtením, byla,
pokud pacient nepřečetl text vůbec. Z grafu můžeme vidět, že při aniseikonii 2 % a 4 % neměl
potíže se čtením žádný z pacientů. V případě 6% aniseikonie to bylo pouze necelých 10 %
probandů a v případě 8% aniseikonie asi 30 % probandů. Výrazné potíže se čtením při
navozené aniseikonii se tedy neukázaly.
Graf 4: Velikost aniseikonie, při které pacient udává potíže se čtením
Graf 5 se týká distorze a vlnění obrazu. Můžeme vidět, že tento problém nenastával příliš
často. Pacient byl dotázán, zda se mu text zdá zdeformovaný, zvlněný nebo prohnutý a byl
vyzván, aby text četl. Tento projev byl pacienty častěji udáván až při navození 8% aniseikonie,
zde udávalo distorzi obrazu asi 35% probandů.
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
procentopacientů
Velikost aniseikonie v %
Nevolnost/motání hlavy
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
procentopacientů
Velikost aniseikonie v %
Potíže se čtením
VII. CSKO 20. 10. 2016
225
Graf 5: Velikost aniseikonie, při které pacient pociťuje distorzi a vlnění obrazu
V grafu 6 můžeme vidět, jaké procento probandů udávalo při navození aniseikonie
dvojité vidění. Můžeme vidět, že při aniseikonii 6 % diplopii udávalo pouze asi 30 % probandů.
V tomto případě by se tedy u téměř 70 % subjektů nepotvrdila hranice binokulárního vidění
5% aniseikonie. Až při navozené aniseikonii 8 % udávalo dvojité vidění více než 50 % subjektů.
Graf 6: Velikost aniseikonie, při které pacient udává dvojité vidění
Poslední graf shrnuje všechny subjektivní příznaky do jednoho grafu. Můžeme vidět, že
alespoň 50 % probandů zaznamenalo změnu již u 4% aniseikonie, minimálně 50 % probandů
pociťovalo nepříjemnou bolest a tahání za oči až u 6% aniseikonie a minimálně 50 % probandů
zaznamenalo dvojité vidění až při aniseikonii 8 %. Příznaky jako nevolnost, distorzi a potíže se
čtením neudávalo 50 % subjektů ani při 8% aniseikonii.
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
procentopacientů
Velikost aniseikonie v %
Distorze/vlnění obrazu
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
procentopacientů
Velikost aniseikonie v %
Dvojité vidění
VII. CSKO 20. 10. 2016
226
Graf 7: Aniseikonie, kdy alespoň 50% subjektů pociťovalo uvedené potíže
Diskuze
Literatura udává, že hranice binokulárního vidění je 5% aniseikonie, v naší studii se tato
hypotéza potvrdila pouze u 30 % subjektů, tito udávali dvojité vidění při navození 6%
aniseikonie. Dále jsme zjistili, že téměř 80 % probandů, nepocítilo žádnou změnu při navození
2% aniseikonie. Z naší studie by tedy vyplývalo, že anizometropie o hodnotě 1 D by neměla
působit pacientovi žádné problémy. Nevolnost, potíže se čtením a distorzi obrazu v naší studii
zaznamenalo při všech hodnotách navozené aniseikonie pouze pod 50 % probandů.
Závěr
Naší studie se zúčastnilo prozatím 37 subjektů bez oční patologie, bez vlastní aniseikonie
a s dosaženým visem minimálně 1,0. Pomocí dotazníku byly zjišťovány subjektivní pocity
probandů při uměle navozené aniseikonii. Dotazy byly pokládány postupně, od dotazů na
nejméně závažné projevy aniseikonie po nejzávažnější projev aniseikonie, což je porucha
binokulárního vidění - diplopie.
Na závěr se podíváme podrobněji na výsledky pro hodnotu navozené aniseikonie 6 %,
což je blízko k udávané hranici binokulárního vidění 5 %, pak při této aniseikonii bylo jako
nečastější projev udáváno zaznamenání změny (zaznamenalo téměř 85 % probandů), dále
bolest oka/tahání za oči (70 % subjektů), nevolnost a motání hlavy (30 % subjektů), dále dvojité
vidění (30 % probandů), další příznak byla distorze a vlnění obrazu (udávalo asi 25 %
probandů), nejméně udávaným projevem byly potíže se čtením (7 % probandů).
0%
1%
2%
3%
4%
5%
6%
7%
8%
9%
velikostaniseikoniev%
Velikost aniseikonie, kdy alespoň 50% pacientů
pociťuje uvedené potíže
Pociťuje změnu? Bolest oka/tahání za oči?
Nevolnost/motání hlavy Potíže se čtením
Distorze/vlnění obrazu? Dvojité vidění
VII. CSKO 20. 10. 2016
227
Zdroje
Česká oční optika [online]. 2006, 47(03) [cit. 2016-06-25]. ISSN 1211-233X. Dostupné z:
http://www.4oci.cz/dokumenty/pdf/4oci_2006_03.pdf
Wilson, J. MEASURING ANISEIKONIA USING SCATTERING FILTERS TO SIMULATE
CATARACT [online]. BIRMINGHAM, ALABAMA, 2011 [cit. 2016-06-25]. Dostupné z:
http://www.mhsl.uab.edu/dt/2011m/wilson.pdf
Kubošová, R. Anizometropie a anizeikonie - diagnostika, princip korekce [online]. Brno, 2015
[cit. 2016-06-25]. Dostupné z: http://is.muni.cz/th/395303/lf_b/BP.pdf
Autrata, R. Nauka o zraku. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví,
2002. ISBN 80-7013-362-7.
Mccarthy, P. Anisometropia: what difference does it make? Optometry in Practice [online].
2013,14(1), 10 [cit. 2016-06-27]. Dostupné z: http://www.college-
optometrists.org/filemanager/root/site_assets/oip/14-1/6178_oip_vol_14_issue_1-
2013_1_p1-10_mccarthy_interactive_d5_5.pdf
Rutrle, M. Přístrojová optika: učební texty pro oční optiky a oční techniky, optometristy a
oftalmology. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví, 2000. ISBN 80-
7013-301-5.
VII. CSKO 20. 10. 2016
228
Anisometropia effect on the quality of vision
Author: Bc. Eva Staffová
Supervisor: Mgr. Petr Veselý, Dis., Ph.D.
This study focuses on the subjective assessment of anisometropia and aniseikonia
symptoms and finds subjective threshold of binocular vision by patients with induced
aniseikonia. For now, in the study are participated 37 subjects, mean age was 23 years.
Patients achieved with its own correction or after subjective correction the visual acuity at
least 1.0, there was no ocular pathology and significant anisometropia. Using size-lens the
patients has been induced aniseikonia and using a questionnaire we determined subjective
symptoms of the patient when he was reading the text.
The most serious manifestation of aniseikonia is double vision. In our study, diplopia was
reported by only 30 % of subjects in inducing aniseikonia 6 % and by less than 60 % of subjects
at aniseikonia 8 %. Almost 80 % of the probands did not feel any change in the induction of
2% aniseikonia. Inconvenient eye pain was usually noticed by subjects in inducing aniseikonia
from 6 %. The least reported symptoms were nausea, difficulty by reading and distortion.
Introduction
Anisometropia is a condition, which is present in different refraction in both eyes. Little
difference in refraction of both eyes occurs quite frequently, absolutely the same refraction
of both eyes is quite rare. Anisometropia due to the formation of the aniseikonia. Aniseikonia
means unequal size of the retinal images of both eyes and can cause impaired vision quality.
Anisometropia
Anisometropia can be divided in terms of causes and in terms of refractive errors. From
the viewpoint causes is anisometropia divided in refractive anisometropia (system) when the
length of both eyes is the same but the difference is present in the optical power of the
refractive media of the eyes and the other type is the axial anisometropia,where the refractive
power of the optical media of the eyes iss of the same, but the axial length of the eyes is
different. There may be situations where they are presented both types and mixed
anisometropia occurs. In terms of refractive errors is anisometropia divided in hyperopic
anisometropia, myopic, astigmatic and mixed, when one eye is myopic and hypermetropic
second. According to research Trotter, 1967 occurs anisometropia to 1 D in 91 %
anizometropic patients from 1 D to 1,75 D 5 % of patients, from 2 D to 2,75 D 2 % of patients
and anisometropia greater than 3 D only in 1,6 % of patients.
With corrected anisometropia occurs the following problems: anisophoria, aniseikonia
and fight for the best accomodate between left and right eye. Anisophoria occurs when
patient is looking over the edge of spectacle lenses, due to different refractive power of
spectacle lenses, act on the eyes uneven prismatic effect. [1,3,5]
VII. CSKO 20. 10. 2016
229
Aniseikonia
Aniseikonia is a typical manifestation of anisometropia. It means unequal of size retinal
images of the right and left eye. Aniseikonia can be divided into physiological, which occurs
due to asymmetric convergence, artificial (spectacle), which arises from the difference in
optical power of corrective lenses and anatomical, that arise because of anatomical
differences in the right and left eyes (for example different axial length). In addition, can
aniseikonia be divided according to the axis into horizontal, vertical, oblique mixed.
Figure 1: Types of aniseikonia – dividing according to the axis[1]
The relationship between anisometropia and aniseikonia is such that about 0.5 D
anisometropia represents about 1 % of the difference in the size of retinal images. Clinically
significant aniseikonia is from 2% difference in size of the retinal images of the right and left
eyes, thus 1 D anisometropia. As a threshold of binocular vision is considered aniseikonia
about 5 %. According to a study from Bannon and Triller, 1994 these are the characteristic
symptoms aniseikonia: headache, asthenopia, photophobia, difficulty in reading, nausea,
diplopia, nervousness, dizziness, drowsiness, disorientation. [1,4]
Patients and Methods
The study has so far participated 37 subjects, including 30 women and 7 men. Mean age
was 23 years (minimum 19 years, maximum 64 years, SD 9 years). The condition of
participation in the study is made of at least 1,0 visual acuity, patients without significant
ocular pathology and anisometropia. The aim of this study is to find a subjective threshold of
binocular vision by patients without anisometropia and establish the subjective symptoms
with artificially induced aniseikonia.
By each patient was verified his visual acuity with its own correction, if not achieved
visual acuity 1,0 with own correction, the patient has been corrected to achieve visual acuity
at least 1,0 on both eyes. It was subsequently verified the presence aniseikonia using anaglyph
hook test and red-green filter. By none of the patients was detected aniseikonia. Followed by
verification of visual acuity at near with reading of the text, the patient had to read a line of
0,8. While he was fixing the text, was presented to the patient gradually size lens in front of
the right eye. The values of lens size was 2 %, 4 %, 6 %, 8 %. Each time the lens has been
presented, the patient was asked to read the selected text line and was interviewed on the
VII. CSKO 20. 10. 2016
230
questionnaire (see Table 1). The patient was asked if the symptoms of aniseikonia is perceived
or not. Size lens were presented from the lowest value to highest. The results of the
questionnaires were introduced into an Excel spreadsheet and processed using Excel graphs.
When creating the questionnaire, we were inspired by studies from Jason Wilson, 2011 Measuring
aniseikonia using filters to simulate cataract. [2,6]
Table 1: Questionnaire
Figure 2: Questionaire from Jason Wilson´s study, 2011[2]
VII. CSKO 20. 10. 2016
231
Results
Questionnaire responses were recorded in Excel spreadsheets and analyzed using
charts. Each chart is created for a subjective symptom. We evaluated how large percentage of
patients experienced some symptom in the presented value of the lens size. The general chart
is recorded for each value of aniseikonia for each subjectively noticed symptom, that has
experienced at least 50 % of the probands. The first chart shows that only about 20 % of the
probands noticed changes in aniseikonia 2 %. When aniseikonia was 4 %, which is close to the
threshold of binocular vision, has experienced a change of approximately 75 % of patients.
From this chart, we can conclude that already aniseikonia 4 % will be for the patient less
tolerable.
Chart 1: Value of aniseikonie, when the patient notices change
From chart 2 we can determine what percentage of the probands felt by persenting size
lens unpleasant pain in eyes. At 2% aniseikonia the pain was reported by only a small
percentage of people. When presenting the size lens of 4 % experienced pain in the eyes of
almost 40 % of subjects. And in inducing aniseikonia 6 % have already experienced unpleasant
and painful sensations around 70 % of the probands. Such percentage aniseikonia would thus
be for the majority of patients already unbearable.
Chart 2: Value of aniseikonie, when the patient feels eyes pain
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
percentageofpatients
Aniseikonia value in %
Patient notices the change
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
percentageofpatients
Aniseikonia value in %
Eyes pain
VII. CSKO 20. 10. 2016
232
Another question concerned the nausea and dizziness. The patient was asked to read
the text after presenting size lens and was asked whether he feels some dizziness or nausea.
From Figure 3, we see that by 6% aniseikonia this manifestation confirmed patients only to a
small extent. Except in the case of 8% aniseikonia, here was reported nausea and dizziness
nearly 50 % of probands.
Chart 3: Value of aniseikonie, when the patient feels dizzines or nausea
Figure 4 shows how a large percentage of probands when presenting size lens has
difficulty with reading. When presenting lens size, the patient was asked to read the text. The
situation, which was recorded in a questionnaire as a problem with reading, was when a
patient did not read the text at all. From the graph we can see that when we induced
aniseikonia 2 % and 4 % the patients had no difficulty with reading. In the case of 6%
aniseikonia it was only less than 10% of the probands and the 8% aniseikonia about 30 % of
probands. Significant difficulty with reading by induced aniseikonia therefore was not proven.
Chart 4: Value of aniseikonia, when the patient indicates difficulty by reading
Chart 5 relates to distortion of the image. We can see that this symptom is not
experienced very often. The patient was asked whether his text seems distorted, warped or
bent and was asked to read the text. This symptom was frequently stated by patients at
induction of 8% aniseikonia, there was reported distortion about 35 % of probands.
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
percentageofpatients
Aniseikonia value in %
Dizziness/nausea
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
percentageofpatients
Aniseikonia value in %
Difficulty by reading
VII. CSKO 20. 10. 2016
233
Chart 5: Value of aniseikonia, when the patient indicates distortion
In chart 6, we can see what percentage of probands was reported in inducing aniseikonia
double vision. We can see that when aniseikonia was 6 %, diplopia was reported by only about
30 % of the probands. In this case, therefore, in almost 70 % of the subjects did not confirm
the threshold of binocular vision – 5% aniseikonia. When induced aniseikonia was 8 %
reported double vision more than 50 % of subjects.
Chart 6: Value of aniseikonia, when the patient indicates double vision
The last chart summarizes all subjective symptoms in one graph. We can see that at least
50 % of the probands noticed changes already at 4% aniseikonia, at least 50 % of the probands
felt uncomfortable pain behind the eyes by 6% aniseikonia and at least 50 % of probands
experienced double vision when aniseikonia was 8 %. Symptoms such as nausea, distortion
and difficulty reading did not notice neither 50 % of subjects even while 8% aniseikonia.
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
percentageofpatients
Aniseikonia value in %
Distortion
0%
20%
40%
60%
80%
100%
2% 4% 6% 8%
percentageofpatients
Aniseikonia value in %
Double vision
VII. CSKO 20. 10. 2016
234
Chart 7: The value of aniseikonia when at least 50 % of patients indicated
referred difficulties
Discussion
Literature indicates that the limits of binocular vision is 5% aniseikonia, in our study, this
hypothesis is confirmed only in 30 % of subjects, they reported diplopia by inducing 6%
aniseikonia. Furthermore, we found out that almost 80 % of the probands did not feel any
change in the induction of 2% aniseikonia. From our studies therefore suggest that
anisometropia a value 1 D should not cause any problems to the patients. Nausea, difficulty
reading and image distortion in our study experienced at all values of induced aniseikonia just
under 50 % of the probands.
Conclusion
Our study involved 37 subjects with no ocular pathology, without its own aniseikonia
and achieved visual acuity at least 1,0. Using a questionnaire were investigated subjective
feelings of probands in artificially induced aniseikonia. Questions were considered
sequentially, from questions of least serious manifestations aniseikonia to the most serious
manifestation aniseikonia, a disorder of binocular vision.
In conclusion, we look in more detail at the results for the value of the induced
aniseikonia 6 %, which is close to the indicated limit of binocular vision 5 %. By indicated
aniseikonia 6 % was as the most common manifestation determined at feeling changes
(recorded almost 85 % of the probands) further eye pain (70 % of subjects), nausea and
dizziness (30 % of subjects), followed by double vision (30 % probands), another symptom the
distortion of image (was reported about 25 % of probands), at least indicated symptom
was difficulty reading (7 % probands).
0%
1%
2%
3%
4%
5%
6%
7%
8%
9%
Aniseikoniavaluein%
The value of aniseikonia when at least 50% of patients
indicated referred difficulties
Does the patient feel the change? Eye pain is presented?
Nausea/dizzines? Difficulty by reading?
VII. CSKO 20. 10. 2016
235
References
Česká oční optika [online]. 2006, 47(03) [cit. 2016-06-25]. ISSN 1211-233X. Dostupné z:
http://www.4oci.cz/dokumenty/pdf/4oci_2006_03.pdf
Wilson, J. MEASURING ANISEIKONIA USING SCATTERING FILTERS TO SIMULATE
CATARACT [online]. BIRMINGHAM, ALABAMA, 2011 [cit. 2016-06-25]. Dostupné z:
http://www.mhsl.uab.edu/dt/2011m/wilson.pdf
Kubošová, R. Anizometropie a anizeikonie - diagnostika, princip korekce [online]. Brno, 2015
[cit. 2016-06-25]. Dostupné z: http://is.muni.cz/th/395303/lf_b/BP.pdf
Autrata, R. Nauka o zraku. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví,
2002. ISBN 80-7013-362-7.
Mccarthy, P. Anisometropia: what difference does it make? Optometry in Practice [online].
2013,14(1), 10 [cit. 2016-06-27]. Dostupné z: http://www.college-
optometrists.org/filemanager/root/site_assets/oip/14-1/6178_oip_vol_14_issue_1-
2013_1_p1-10_mccarthy_interactive_d5_5.pdf
Rutrle, M. Přístrojová optika: učební texty pro oční optiky a oční techniky, optometristy a
oftalmology. Brno: Institut pro další vzdělávání pracovníků ve zdravotnictví, 2000. ISBN 80-
7013-301-5.
VII. CSKO 20. 10. 2016
236
Lids and contact lenses
Author: Erna Vukalić
Contact lenses can be classified by four elements – nature of the material they are made
of, their wearing schedule, their purpose, and their design. A number of factors determine
whether a client is a good candidate for wearing contact lenses.
A detailed history (information about the client's general medical health, ocular health,
family history of eye disease etc.) and an ocular examination are necessary for fitting a contact
lens.
Contact lens wearing may be compromised by many segment conditions (ectropion,
entropion, blepharitis, lagophthalmos etc.) or be the cause of such conditions.
Contraindications for contact lenses may include ocular infections and inflammation.
Whichever contraindication is eliminated, the client can be reevaluated, bearing in mind that
a successful fitting is almost always based on a strong indication.
Anatomy and physiology
Apart from providing mechanical defense for the eye and maintaining a clear refracting
surface of the eye by forming the tear layer after every blink, eyelids play a significant role in
the positioning, orientation and movement of contact lenses.
Lid function includes: mechanical protection for the eye, providing corneal metabolism
by circulating tears, and keeping clear the first refracting surface of the eye by forming the
tear layer after every blink. Understanding of the eyelid blink dynamics is essential for fitting
toric and bifocal lenses. Those dynamics are explained through a number of anatomical
components of the lid, muscles (orbicularis oculi for lid closure and levator palpebrae
superioris for lid elevation), skin (dermis), lashes (cilia), nerves (third and seventh cranial
nerve, autonomic nerves), connective tissue (tarsal plates), glands (Zeiss, Moll, and
Meibomian).
VII. CSKO 20. 10. 2016
237
Picture 1: Sagittal section through the eye
Examination
Knowing the client history is essential for establishing the viability of wearing contact
lens, so all potential and current lens wearers should undergo a full ophthalmic history and
examination in order to exclude any conditions that may contraindicate lens wearing, record
any abnormalities and identify and treat conditions such as blepharitis before the lens are
worn.
An accurate eye examination requires a careful assessment of the eyelids, eyelashes and
the lacrimal system.
The palpebral aperture is normally 9-11 mm in height, 26-30 mm in width and its size is
defined by the shape and position of the eyelids. The size of the client’s fissure has a direct
influence on fitting RGP lenses and problem solving.
Also, the eyelid tension is an important factor when fitting rigid, alternating, bifocal
lenses because the lower eyelid needs to be sufficiently tight and high so that it can push the
lens up with downward gaze to center the reading portion over the pupil.
Blinking is very important for corneal health and integrity and it can be divided into
reflex, conscious and unconscious (spontaneous). Spontaneous blinking is the most common
type of blinking which occurs 10-15 times per minute and its total duration is 250 to 300 msec.
If RGP lens wearer blinks incompletely or infrequently, this can result in dryness and in 3 and
9 o'clock staining. Clients with such problems should be instructed to practice closing the eye
gently and completely. The contact lens moves with each blink, and the blink-associated lens
VII. CSKO 20. 10. 2016
238
movement results in decreased visual performance. However, this decrease is not noticed due
to the suppression of vision that occurs with each blink.
The Meibomian glands secrete oil that makes up a lipid layer of the tear film. Poor tear
film quality and contact lens problems are the result of cloudy or insufficient oil production.
Diseases related to contact lens wearing
Scarred and distorted eyelids may lead to dryness and irritation of the eyelid margins by
the lens edge. If stagnant pools of tear fluid are created, the risk of infection increases.
Pathological changes to the eyelids may include:
Entropion - an inversion of the eyelid towards the globe that usually causes discomfort
because eyelashes rub against the cornea. This may result in bad lens positioning due to the
lower lid interference with the lens.
Picture 2: A lower eyelid entropion (Source: www.eyelidsurgery.co.uk)
Ectropion - an eversion of the eyelid mainly caused by senile changes, scarring of the
anterior lamella of the eyelid or facial nerve (cranial nerve VII) palsy. The puncta are everted
and can result in poor lacrimal drainage with a stagnant pool of tear fluid in the lower fornix
which may lead to an infection. Ectropion is frequently associated with chronic conjunctivitis
and epiphora. This state of the eyelid causes the problem in the form that the lower lid cannot
be relied upon to help position the lens. In other words, rigid and soft lenses may mislocate
inferiorly. This may also result in dryness due to an excessive rate of tear loss.
Lagophthalmos - refers to the incomplete eyelid closure. It can be caused by a number
of factors (facial nerve lesions, orbicularis weakness, ectropion or mechanical displacement
due to tumours) and may lead to corneal exposure and create keratitis. A soft lens will provide
protection, but if the lagophthalmos is severe, lenses can fall out of the eye. RGP lenses do
not completely cover the cornea and can cause corneal desiccation outside the lens edge,
usually in 3 and 9 o’clock position.
Blepharitis - may result in trichiasis, loss of lashes, scarring of the eyelid and can cause
chalazia and styes. Visible redness, sticking eyelashes, scales at eyelash roots are manifested.
One feels warmth, itching, slight photophobia, as well as a foreign body feeling. Dryness of
the eye is felt more acutely in the morning and there is intolerance to lenses. Therapy is
VII. CSKO 20. 10. 2016
239
required in the form of antibiotics, corticosteroids, artificial tears, increased hygiene of the
lids. Lenses should not be worn during the acute phase (which usually lasts about seven days).
An external hordeolum - commonly known as "stye". It's a discrete, inflamed swelling of
the anterior lid margin and is typical for an acute staphylococcal infection, sometimes related
to the inflammation of Zeis or Moll’s gland. Clients should stop wearing lenses during the acute
phase of the formation of a stye.
Picture 3: Hordeolum (Source: Western Ophthalmic Hospital)
A chalazion - chronic granuloma of the Meibomian glands that can occur when a
Meibomian gland is blocked. It is a well-formed firm swelling in the upper or lower eyelid that
can be related to a conjunctival granuloma, which can be seen when the eyelid is everted.
Chalazion presses the globe and it can cause astigmatism. It is not recommended to prescribe
spectacles or fit contact lenses until the swelling has subsided.
Picture 4: Chalazion (Source: www.primehealthchannel.com)
Location Etiology Pain
Hordeolum (Stye) Follicle or Tarsal Gland
Sterile or purulent
inflammation
Tender
Chalazion Tarsal Gland
Obstruction of
meibomian gland
Non-
tender
Table 1: Difference between hordeolum and chalazion
VII. CSKO 20. 10. 2016
240
Conclusion
With people who wear or will wear contact lenses, eyelids have an essential role. As the
physiological structure of the lid has a vital function, therefore many illnesses which the lid
can contract have a huge effect on the wearers of contact lenses. Contact lenses are
contraindicated among those people until the illnesses have been treated.
If a person prefers wearing contact lenses, it is important to perform an examination
and assessment to determine whether that person is an adequate candidate for wearing
contact lenses. An optometrist's duty is to give quality advice and instruct the person on using
the contact lenses, maintaining the hygiene and cleanliness of the contact lenses, as well as
warning the clients about possible complications while using the contact lenses.
References
Millis, E. A. W. Medical Contact Lens Practice. New York: Butterworth-Heinemann, 2005. ISBN
978-075-0643-276.
Efron, N. Contact Lens Complications Expert Consult - Online and Print. 3rd ed. London:
Elsevier Health Sciences UK, 2012. ISBN 978-145-5737-741.
Mannis, M. J. Contact lenses in ophthalmic practice. New York: Springer, c2003. ISBN
0387404007.
Hom, M. M. Manual of contact lens prescribing and fitting. Boston: Butterworth-Heinemann,
2006. ISBN 0750697415.
Beljan, J., Beljan, K., Beljan, Z. Complications caused by contact lens wearing.Collegium
antropologicum 37 Suppl 1. 2013, 179-187.
Název: Sborník přednášek a posterů
„VII. CELOSTÁTNÍ STUDENTSKÁ KONFERENCE OPTOMETRIE
A ORTOPTIKY S MEZINÁRODNÍ ÚČASTÍ“
Vydal: NCONZO, Vinařská 6, 603 00 Brno
Pořadatelé sborníku: Mgr. Pavel Beneš, Ph.D.1
; Mgr. Sylvie Petrová1
;
Doc. MUDr. Svatopluk Synek, CSc.1
; Mgr. Petr Veselý, DiS., Ph.D.1
;
Bc. Marie Kodetová1
; Bc. Zuzana Odvárková; Bc. Jolana Nedvědová1
1
Katedra optometrie a ortoptiky, LF MU Brno, Pekařská 53, 656 91 Brno
Počet stran: 240
Výrobní číslo: 57/2016
ISBN: 978-80-7013-583-9
Tirážní znak: 57-853-16