by Stuart Sutherland www.sutherland-hdl.com Verilog® HDL Quick Reference Guide based on the Verilog-2001 standard (IEEE Std 1364-2001) Sutherland HDL Copyright © 2001, Sutherland HDL, Inc., all rights reserved. Permission is granted by Sutherlaand HDL to download and/or print the PDF document containing this reference guide from www.sutherland-hdl.com for personal use only. The reference guide may not be used for commercial purposes or distributed in any form or by any means without obtaining express permission from Sutherland HDL. Verilog® HDL Quick Reference Guide based on the Verilog-2001 standard (IEEE Std 1364-2001) by Stuart Sutherland published by Sutherland HDL, Inc. 22805 SW 92nd Place Tualatin, OR 97062 (503) 692-0898 www.sutherland-hdl.com Copyright © 1992, 1996, 2001 by Sutherland HDL, Inc. 09/2007 Sutherland HDL Copyright © 1992, 1996, 2001 by Sutherland HDL, Inc. All rights reserved. No part of this book may be reproduced in any form or by any means without the express written permission of Sutherland HDL, Inc. Sutherland HDL, Inc. 22805 SW 92nd Place Tualatin, OR 97062-7225 Phone: (503) 692-0898 URL: www.sutherland-hdl.com ISBN: 1-930368-03-8 Verilog® is a registered trademark of Cadence Design Systems, San Jose, CA. Verilog HDL Quick Reference Guide Table of Contents 1.0 New Features In Verilog-2001 ..................................................... 1 2.0 Reserved Keywords ...................................................................... 2 3.0 Concurrency ................................................................................. 3 4.0 Lexical Conventions ..................................................................... 3 4.1 Case Sensitivity ................................................................... 3 4.2 White Space Characters ....................................................... 3 4.3 Comments ............................................................................ 3 4.4 Attributes ............................................................................. 3 4.5 Identifiers (names) ............................................................... 4 4.6 Hierarchical Path Names ..................................................... 4 4.7 Hierarchy Scopes and Name Spaces ................................... 4 4.8 Logic Values ........................................................................ 5 4.9 Logic Strengths .................................................................... 5 4.10 Literal Real Numbers .......................................................... 5 4.11 Literal Integer Numbers ...................................................... 6 5.0 Module Definitions ....................................................................... 7 5.1 Module Items ....................................................................... 7 5.2 Port Declarations ................................................................. 8 6.0 Data Type Declarations .............................................................. 10 6.1 Net Data Types .................................................................. 10 6.2 Variable Data Types .......................................................... 12 6.3 Other Data Types ............................................................... 14 6.4 Vector Bit Selects and Part Selects ................................... 15 6.5 Array Selects ..................................................................... 15 6.6 Reading and Writing Arrays .............................................. 15 7.0 Module Instances ........................................................................ 16 8.0 Primitive Instances ..................................................................... 18 9.0 Generate Blocks ......................................................................... 20 10.0 Procedural Blocks ....................................................................... 22 10.1 Procedural Time Controls .................................................. 23 10.2 Sensitivity Lists ................................................................. 23 10.3 Procedural Assignment Statements ................................... 24 10.4 Procedural Programming Statements ................................ 25 11.0 Continuous Assignments ............................................................ 27 12.0 Operators .................................................................................... 28 13.0 Task Definitions ......................................................................... 30 14.0 Function Definitions ................................................................... 31 15.0 Specify Blocks ............................................................................ 32 15.1 Pin-to-pin Path Delays ....................................................... 32 15.2 Path Pulse (Glitch) Detection ............................................ 33 15.3 Timing Constraint Checks ................................................. 34 16.0 User Defined Primitives (UDPs) ................................................ 35 17.0 Common System Tasks and Functions ...................................... 37 18.0 Common Compiler Directives .................................................... 40 19.0 Configurations ............................................................................ 42 20.0 Synthesis Supported Constructs ................................................. 44 Verilog HDL Quick Reference Guide 2 1.0 New Features In Verilog-2001 Verilog-2001, officially the “IEEE 1364-2001 Verilog Hardware Description Language”, adds several significant enhancements to the Verilog-1995 standard. • Attribute properties (page 4) • Generate blocks (page 21) • Configurations (page 43) • Combined port and data type declarations (page 8) • ANSI C style port definitions (page 8) • Arrays of net data types (page 11) • Multidimensional arrays (page 11, 13) • Variable initialization with declaration (page 13) • Bit and part selects of array words (page 16) • Indexed vector part selects (page 16) • Explicit in-line parameter passing (page 17) • Comma separated sensitive lists (page 24) • Combinational logic sensitivity wild card (page 24) • Inferred nets with any continuous assignment (page 28) • Power operator (page 29) • Signed arithmetic extensions (page 7, 9, 11, 13, 29, 32, 38) • ANSI C style task/function I/O definitions (page 31, 32) • Re-entrant tasks (page 31) • Recursive functions (page 32) • Constant functions (page 32) • On-detect pulse detection (page 34) • Negative pulse detection (page 34) • Negative timing constraints (page 35) • New timing constraint checks (page 35) • Enhanced file I/O (page 39) • Enhanced testing of invocation options (page 39) • Enhanced conditional compilation (page 41) • Disabling of implicit net declarations (page 41) © Sutherland HDL, Inc. 3 2.0 Reserved Keywords always and assign automatic† begin buf bufif0 bufif1 case casex casez cell† cmos config† deassign default defparam design† disable edge else end endcase endconfig† endfunction endgenerate† endmodule endprimitive endspecify endtable endtask event for force forever fork function generate† genvar† highz0 highz1 if ifnone initial instance† inout input integer join large liblist† localparam† macromodule medium module nand negedge nmos nor not noshowcancelled† notif0 notif1 or output parameter pmos posedge primitive pull0 pull1 pulldown pullup pulsestyle_onevent† pulsestyle_ondetect† rcmos real realtime reg release repeat rnmos rpmos rtran rtranif0 rtranif1 scalared signed showcancelled† small specify specparam strength strong0 strong1 supply0 supply1 table task time tran tranif0 tranif1 tri tri0 tri1 triand trior trireg unsigned use† vectored wait wand weak0 weak1 while wire wor xnor xor 4 Verilog HDL Quick Reference Guide 3.0 Concurrency The following Verilog HDL constructs are independent processes that are evaluated concurrently in simulation time: • module instances • primitive instances • continuous assignments • procedural blocks 4.0 Lexical Conventions 4.1 Case Sensitivity Verilog is case sensitive. 4.2 White Space Characters blanks, tabs, newlines (carriage return), and formfeeds. 4.3 Comments // begins a single line comment, terminated by a newline. /* begins a multi-line block comment, terminated by a */. 4.4 Attributes (* begins an attribute, terminated by a *). • An attribute specifies special properties of a Verilog object or statement, for use by specific software tools, such as synthesis. Attributes were added in Verilog-2001. • An attribute can appear as a prefix to a declaration, module items, statements, or port connections. • An attribute can appear as a suffix to an operator or a call to a function. • An attribute may be assigned a value. If no value is specified, the default value is 1. • Multiple attributes can be specified as a comma-separated list. • There are no standard attributes in the Verilog-2001 standard; Software tools or other standards will define attributes as needed. Attribute Example (* full_case, parallel_case *) case (state) ... endcase assign sum = a + (* CLA=1 *) b; † indicates new reserved words that were added in the Verilog-2001 standard. © Sutherland HDL, Inc. 5 4.5 Identifiers (names) • Must begin with alphabetic or underscore characters a-z A-Z _ • May contain the characters a-z A-Z 0-9 _ and $ • May use any character by escaping with a backslash ( \ ) at the beginning of the identifier, and terminating with a white space. • Identifiers created by an array of instances or a generate block may also contain the characters [ and ]. 4.6 Hierarchical Path Names A net, variable, task or function can be referenced anywhere in the design hierarchy using either a full or relative hierarchy path. • A full path consists of the top-level module, followed by any number of module instance names down to the object being reference. A period is used to separate each name in the hierarchy path. • A relative path consists of a module instance name in the current module, followed by any number of module instance names down to the object being referenced. A period is used to separate each name in the hierarchy path. 4.7 Hierarchy Scopes and Name Spaces There are four primary types of name spaces. • Global names are visible in all names spaces: • Module, primitive and configuration definition names • Text macro names (created by ‘define). Macro names are only visible from the point of definition on; source code compiled prior to the definition cannot see the macro names. • Scope names create a new level of hierarchy: • module definitions • function definitions • task definitions • named blocks (begin—end or fork—join) • Other name spaces: • specify blocks • attributes An identifier name defined within a name space is unique to that space and cannot be defined again within the same space. In general, references to an identifier name within a scope will search first in the local scope, and then search upward through the scope hierarchy up to a module boundary. Examples Notes adder legal identifier name XOR uppercase identifier is unique from xor keyword \reset- an escaped identifier (must be followed by a white space) 6 Verilog HDL Quick Reference Guide 4.8 Logic Values Verilog uses a 4 value logic system for modeling. There are two additional unknown logic values that may occur internal to the simulation, but which cannot be used for modeling. 4.9 Logic Strengths Logic values can have 8 strength levels: 4 driving, 3 capacitive, and high impedance (no strength). A net with multiple drivers can have a combination of strengths, represented as a pair of octal numbers, plus the value (e.g. 65X). 4.10 Literal Real Numbers • Real numbers are represented in double-precision floating point form. • There must be a value on either side of the decimal point. • The value may only contain the characters 0-9 and underscore. Logic Value Description 0 zero, low, or false 1 one, high, or true z or Z high impedance (tri-stated or floating) x or X unknown or uninitialized L partially unknown; either 0 or Z, but not 1 (internal simulation value only) H partially unknown; either 1 or Z, but not 0 (internal simulation value only) Strength Level Strength Name Specification Keyword Display Mnemonic 7 supply drive supply0 supply1 Su0 Su1 6 strong drive strong0 strong1 St0 St1 5 pull drive pull0 pull1 Pu0 Pu1 4 large capacitive large La0 La1 3 weak drive weak0 weak1 We0 We1 2 medium capacitive medium Me0 Me1 1 small capacitive small Sm0 Sm1 0 high impedance highz0 highz1 HiZ0 HiZ1 value.value decimal notation baseeexponent baseEexponent scientific notation; there should be no space before and after the e or E token Examples Notes 0.5 must have value on both sides of decimal point 3e4 3 times 104 (30000) 5.8E-3 5.8 times 10-3 (0.0058) © Sutherland HDL, Inc. 7 4.11 Literal Integer Numbers • size (optional) is the number of bits in the number. Unsized integers default to at least 32-bits. • ’base represents the radix and sign property of the value. The base and sign characters are not case sensitive (e.g. ’b and ’B are equivalent). • The ? is another way of representing the Z logic value. • An underscore is ignored (used to enhance readability). The underscore cannot be used as the first character of the value. • Values are expanded from right to left (lsb to msb). • When size is fewer bits than value, the upper bits are truncated. • When size is more bits than value, and the left-most bit of value is 0 or 1, zeros are left-extended to fill the size. • When size is more bits than value, and the left-most bit of value is Z or X, the Z or X is left-extended to fill the size. • Signed numbers are interpreted as 2’s complement values. • Specifying a literal number as signed affects operations on the number; it does not affect expanding a value to the specified size of the number. value unsized decimal integer size’base value sized integer in a specific radix (base) Radix Symbol Legal Values unsigned binary ’b 0, 1, x, X, z, Z, ?, _ unsigned octal ’o 0–7, x, X, z, Z, ?, _ unsigned decimal ’d 0–9, _ unsigned hexadecimal ’h 0–9, a–f, A–F, x, X, z, Z, ?, _ signed binary ’sb 0, 1, x, X, z, Z, ?, _ signed octal ’so 0–7, x, X, z, Z, ?, _ signed decimal ’sd 0–9, _ signed hexadecimal ’sh 0–9, a–f, A–F, x, X, z, Z, ?, _ Examples Size Sign Radix Binary Equivalent 10 unsized signed decimal 0...01010 (32-bits) 'o7 unsized unsigned octal 0...00111 (32-bits) 1'b1 1 bit unsigned binary 1 8'sHc5 8 bits signed hex 11000101 6'hF0 6 bits unsigned hex 110000 (truncated) 6'hA 6 bits unsigned hex 001010 (zero filled) 6'shA 6 bits signed hex 001010 (zero filled) 6'bZ 6 bits unsigned binary ZZZZZZ (Z filled) 8 Verilog HDL Quick Reference Guide 5.0 Module Definitions Verilog HDL models are represented as modules. (refer to the next page for the syntax of port declarations) port_name can be either: • A simple name, which implicitly connects the port to an internal signal with the same name. • A name with an explicit internal connection, in the form of .port_name(signal), which connects the port to an internal signal with a different name, or a bit select, part select, or concatenation of internal signals. Note: it is the internal signal name that is given a direction, not the port name. The keyword macromodule is a synonym for module. 5.1 Module Items A module may contain any of the following items: • Module items may appear in any order, but port, data_type or parameter declarations must come before the declared name is referenced. • Module functionality may be represented as: • Behavioral or RTL — modeled with procedural blocks or continuous assignment statements. • Structural — a netlist of module instances or primitive instances. • A mix of behavioral and structural. ANSI-C Style Port List (added in Verilog-2001) module module_name #(parameter_declaration, parameter_declaration,... ) (port_declaration port_name, port_name,..., port_declaration port_name, port_name,...); module items endmodule Old Style Port List module module_name (port_name, port_name, ... ); port_declaration port_name, port_name,...; port_declaration port_name, port_name,...; module items endmodule data_type_declarations parameter_declarations module_instances primitive_instances generate_blocks procedural_blocks continuous_assignments task_definitions function_definitions specify_blocks (see section 6.0) (see section 6.3) (see section 7.0) (see section 8.0) (see section 9.0) (see section 10.0) (see section 11.0) (see section 13.0) (see section 14.0) (see section 15.0) © Sutherland HDL, Inc. 9 5.2 Port Declarations • port_direction is declared as: • input for scalar or vector input ports. • output for scalar or vector output ports. • inout for scalar or vector bidirectional ports. • data_type (optional) is any of the types listed in section 6.0, except real. Combined port/data type declarations were added in Verilog-2001. • signed (optional) indicates that values passed through the port are interpreted as 2’s complement signed values. If either the port or the data type of the internal signal connected to the port are declared as signed, then both are signed. Signed ports were added in Verilog-2001. • range (optional) is a range from [msb :lsb] (most-significant-bit to least- significant-bit). • If no range is specified, ports are 1-bit wide. • The msb and lsb must be a literal number, a constant, an expression, or a call to a constant function. • Either little-endian convention (the lsb is the smallest bit number) or bigendian convention (the lsb is the largest bit number) may be used. • The maximum port size may be limited, but will be at least 256 bits. Most software tools have a limit of 1 million bits. • Port/data type connection rules: • A real variable cannot be directly connected to a port. Real numbers can first be converted to or from 64-bit vectors using the $realtobits and $bitstoreal system tasks. • The port range and data type range must be the same (if different, some software tools will use the data type size instead of reporting an error). • The port direction must be declared before the data type is declared. Combined Declarations (added in Verilog-2001) port_direction data_type signed range port_name, port_name, ... ; Old Style Declarations port_direction signed range port_name, port_name, ... ; data_type_declarations (see section 6.0) input ports output ports inout ports Module Instance (outside the module) expression, net or variable types (except real) net types only net types only Module Definition (inside the module) net types only net or variable types (except real) net types only 10 Verilog HDL Quick Reference Guide Port Declaration Examples Notes input a,b,sel; three scalar (1-bit) ports input signed [15:0] a, b; two 16-bit ports that pass 2’s complement values, little endian convention output signed [31:0] result; 32-bit port; values passed through the port are in 2’s complement form output reg signed [32:1] sum; 32-bit port; the internal signal connected to the port is a signed reg data type inout [0:15] data_bus; big endian convention input [15:12] addr; msb:lsb may be any integer parameter WORD = 32; input [WORD-1:0] addr; constant expressions may be used in the declaration parameter SIZE = 4096; input [log2(SIZE)-1:0] addr; constant functions may be called in the declaration © Sutherland HDL, Inc. 11 6.0 Data Type Declarations Verilog has two major data type classes: • Net data types are used to make connections between parts of a design. • Nets reflect the value and strength level of the drivers of the net or the capacitance of the net, and do not have a value of their own. • Nets have a resolution function, which resolves a final value when there are multiple drivers on the net. • Variable data types are used as temporary storage of programming data. • Variables can only be assigned a value from within an initial procedure, an always procedure, a task or a function. • Variables can only store logic values; they cannot store logic strength. • Variables are un-initialized at the start of simulation, and will contain a logic X until a value is assigned. 6.1 Net Data Types Nets are used connect structural components together. • A net data type must be used when a signal is: • Driven by the output of a module instance or primitive instance. • Connected to an input or inout port of the module in which it is declared. • On the left-hand side of a continuous assignment. • net_type is one of the following keywords: General Rules For Choosing The Correct Data Type Class when a signal is driven by a module output, a primitive output, or a continuous assignment use a net type when a signal is assigned a value in a Verilog procedure use a variable type net_type signed [range] #(delay) net_name [array], ... ; net_type (drive_strength) signed [range] #(delay) net_name = continuous_assignment; trireg (capacitance_strength) signed [range] #(delay, decay_time) net_name [array], ... ; wire interconnecting wire; CMOS resolution wor wired outputs OR together; ECL resolution wand wired outputs AND together; open-collector resolution supply0 constant logic 0 (supply strength) supply1 constant logic 1 (supply strength) tri0 pulls down when tri-stated tri1 pulls up when tri-stated tri same as wire trior same as wor triand same as wand trireg holds last value when tri-stated (capacitance strength) 12 Verilog HDL Quick Reference Guide • signed (optional) indicates that values are interpreted as 2’s complement signed values. If either a port or the net connected to the port is declared as signed, then both are signed. Signed nets were added in Verilog-2001. • [range] (optional) is a range from [msb :lsb] (most-significant-bit to least- significant-bit). • If no range is specified, the nets are 1-bit wide. • The msb and lsb must be a literal number, a constant, an expression, or a call to a constant function. • Either little-endian convention (the lsb is the smallest bit number) or bigendian convention (the lsb is the largest bit number) may be used. • The maximum net size may be limited, but will be at least 65,536 bits (216 ) bits. Most software tools have a limit of 1 million bits. • delay (optional) may only be specified on net data types. The syntax is the same as primitive delays (refer to section 8.0). • [array] is [first_address : last_address][first_address : last_address]... • Any number of array dimensions may be declared. Arrays of nets were added in Verilog-2001. • first_address and last_address must be a literal number, a constant, an expression, or a call to a constant function. • Either ascending or descending address order may be used. • The maximum array size for each dimension may be limited, but is at least 16,777,216 (224 ). Most software tools have unlimited array sizes. • (strength) (optional) is specified as (strength1, strength0) or (strength0, strength1). See section 4.9 for the strength keywords. • decay_time (optional) specifies the amount of time a trireg net will store a charge after all drivers turn-off, before decaying to logic X. The syntax is (rise_delay, fall_delay, decay_time). The default decay is infinite. • The keywords vectored or scalared may be used immediately following the net_type keyword. Software tools and/or the Verilog PLI may restrict access to individual bits within a vector that is declared as vectored. Net Declaration Examples Notes wire a, b, c; 3 scalar (1-bit) nets tri1 [7:0] data_bus; 8-bit net, pulls-up when tri-stated wire signed [1:8] result; an 8-bit signed net wire [7:0] Q [0:15][0:256]; a 2-dimensional array of 8-bit wires wire #(2.4,1.8) carry; a net with rise, fall delays wire [0:15] (strong1,pull0) sum = a + b; a 16-bit net with drive strength and a continuous assignment trireg (small) #(0,0,35) ram_bit; net with small capacitance and 35 time unit decay time © Sutherland HDL, Inc. 13 6.2 Variable Data Types Variable data types are used for programming storage in procedural blocks. • Variables store logic values only, they do not store logic strength. • A variable data type must be used when the signal is on the left-hand side of a procedural assignment. • Variables were called “registers” in older versions of the Verilog standard. • variable_type is one of the following: • signed (optional) may only be used with reg variables, and indicates that values are interpreted as 2’s complement signed values. If either a port or the reg connected to the port is declared as signed, then both are signed. Signed reg variables were added in Verilog-2001. • [range] (optional) may only be used with reg variables, and is a range from [msb :lsb] (most-significant-bit to least-significant-bit). • If no range is specified, then reg variables are 1-bit wide. • The msb and lsb must be a literal number, a constant, an expression, or a call to a constant function. • Either little-endian convention (the lsb is the smallest bit number) or bigendian convention (the lsb is the largest bit number) may be used. • The maximum reg size may be limited, but will be at least 65,536 (216 ) bits. Most software tools have a limit of 1 million bits. • [array] is [first_address : last_address][first_address : last_address]... • Any number of array dimensions may be declared. Variable arrays of more than one dimension were added in Verilog-2001. • first_address and last_address must be a literal number, a constant, an expression, or a call to a constant function. • Either ascending or descending address order may be used. • The maximum array size for each dimension may be limited, but is at least 16,777,216 (224 ). Most software tools have unlimited array sizes. • A one-dimensional array of reg variables with is referred to as a memory. • initial_value (optional) sets the initial value of the variable. • The value is set in simulation time 0, the same as if the variable had been assigned a value in an initial procedure. • If not initialized, the default value for reg, integer and time variables is X, and the initial value for real and realtime variables is 0.0. • Specifying the initial value as part of the variable declaration was added in Verilog-2000 variable_type signed [range] variable_name, variable_name, ... ; variable_type signed [range] variable_name = initial_value, ... ; variable_type signed [range] variable_name [array], ... ; reg a variable of any bit size; unsigned unless explicitly declared as signed integer a signed 32-bit variable time an unsigned 64-bit variable real a double-precision floating point variable realtime same as real 14 Verilog HDL Quick Reference Guide • The keywords vectored or scalared may be used immediately following the reg keyword. Software tools and/or the Verilog PLI may restrict access to individual bits within a vector that is declared as vectored. Variable Declaration Examples Notes reg a, b, c; three scalar (1-bit) variables reg signed [7:0] d1, d2; two 8-bit signed variables reg [7:0] Q [0:3][0:15]; a 2-dimensional array of 8-bit variables integer i, j; two signed integer variables real r1, r2; two double-precision variables reg clock = 0, reset = 1; two reg variables with initial values © Sutherland HDL, Inc. 15 6.3 Other Data Types Declaration syntax: • signed (optional) indicates that values are interpreted as 2’s complement signed values. Signed constants were added in Verilog-2001. • [range] (optional) is a range from [msb :lsb] (most-significant-bit to least- significant-bit). • If no range is specified, the constant will default to the size of the last value initially assigned to it after any parameter redefinitions. • The msb and lsb must be a literal number, a constant, an expression, or a call to a constant function. • Either little-endian convention (the lsb is the smallest bit number) or bigendian convention (the lsb is the largest bit number) may be used. • The maximum range may be limited, but will be at least 65,536 (216) bits. Most software tools have a limit of 1 million bits. • constant_type (optional) can be integer, time, real or realtime. A constant declared with a type will have the same properties as a variable of that type. If no type is specified, the constant will default to the data type of the last value assigned to it, after any parameter redefinitions. parameter a run-time constant for storing integers, real numbers, time, delays, or ASCII strings; may be redefined for each instance of a module (see section 7.0). localparam a local constant for storing integers, real numbers, time, delays, or ASCII strings; may not be directly redefined, but may be indirectly redefined by assigning the localparam the value of a parameter.. specparam a specify block constant for storing integers, real numbers, time, delays or ASCII strings; may be declared in the module scope or the specify block scope; may be redefined through SDF files or the PLI. genvar a temporary variable used only within a generate loop; cannot be used anywhere else, and cannot be read during simulation. event a momentary flag with no logic value or data storage; can be used for synchronizing concurrent activities within a module. parameter signed [range] constant_name = value, ... ; parameter constant_type constant_name = value, ... ; localparam signed [range] constant_name = value,...; localparam constant_type constant_name = value, ... ; specparam constant_name = value, ... ; event event_name, ... ; 16 Verilog HDL Quick Reference Guide 6.4 Vector Bit Selects and Part Selects • A bit select can be an integer, a constant, a net, a variable or an expression. • A constant part select is a group of bits from within the vector • The part select must be contiguous bits. • The bit numbers must be a literal number or a constant. • The order of the part select must be consistent with the declaration of the vector (e.g. if the lsb is the the lowest bit number in the declaration, then the lsb of the part select must also be the lowest bit number). • Variable part selects can vary the starting point of the part select, but the width of the part select must be a literal number, a constant or a call to a constant function. Variable part selects were added in Verilog-2001. • +: indicates the part select increases from the starting point. • -: indicates the part select decreases from the starting point. 6.5 Array Selects • An array select can be an integer, a net, a variable, or an expression. • Multiple indices, bit selects and part selects from an array were added in Verilog-2001. 6.6 Reading and Writing Arrays • Only one element at a time within an array can be read from or written to. • A memory array (a one-dimensional array of reg variables) can be loaded using the $readmemb, $readmemh, $sreadmemb, or $sreadmemh system tasks. Data Type Examples Notes parameter [2:0] s1 = 3’b001, s2 = 3’b010, s3 = 3’b100; three 3-bit constants parameter integer period = 10; an integer constant localparam signed offset = -5; unsized signed constant defaults to width of initial value event data_ready, data_sent; two event data types Bit Select vector_name[bit_number] Constant Part Select vector_name[bit_number : bit_number] Variable Part Select (added in Verilog-2001) vector_name[starting_bit_number +: part_select_width] vector_name[starting_bit_number -: part_select_width] array_name[index][index]... array_name[index][index]...[bit_number] array_name[index][index]...[part_select] © Sutherland HDL, Inc. 17 7.0 Module Instances • Port order connections list the signals in the same order as the port list in the module definition. Unconnected ports are designated by two commas with no signal listed. • Port name connections list both the port name and signal connected to it, in any order. • instance_name (required) is used to make multiple instances of the same module unique from one another. • instance_array_range (optional) instantiates multiple modules, each instance is connected to different bits of a vector. • The range is specified as [left_hand_index : right_hand_index]. • If the bit width of a module port in the array is the same as the width of the signal connected to it, the full signal is connected to each instance of the module. • If the bit width of a module port is different than the width of the signal connected to it, each module port instance is connected to a part select of the signal, with the right-most instance index connected to the right-most part of the vector, and progressing towards the left. • There must be the correct number of bits in each signal to connect to all instances (the signal size and port size must be multiples). • Instance arrays were added in Verilog-1995, but many software tools did not support them until Verilog-2001. • Multiple instances of a module can also be created using a generate block (see section 9.0). • parameter values within a module may be redefined for each instance of the module. Only parameter declarations may be redefined; localparam and specparam constants cannot be redefined. • Explicit redefinition uses a defparam statement with the parameter’s hierarchical name. • In-line implicit redefinition uses the # token as part of the module instantiation. Parameter values are redefined in the same order in which they are declared within the module. • In-line explicit redefinition uses the # token as part of the module instantiation. Parameter values may be redefined in any order. In-line explicit parameter redefinition was added in Verilog-2001. Port Order Connections module_name instance_name instance_array_range (signal, signal, ...); Port Name Connections module_name instance_name instance_array_range ( .port_name(signal), .port_name(signal), ... ); Explicit Parameter Redefinition defparam heirarchy_path.parameter_name = value; In-line Implicit Parameter Redefinition module_name #(value,value, ...) instance_name (signal, ... ); In-line Explicit Parameter Redefinition (added in Verilog-2001) module_name #(.parameter_name(value), .parameter_name(value), ...) instance_name (signal, ... ); 18 Verilog HDL Quick Reference Guide Module Instance Examples module reg4 (output wire [3:0] q, input wire [3:0] d, input wire clk); //port order connection, no connection to 2nd port position dff u1 (q[0], , d[0], clk); //port name connection, qb not connected dff u2 (.clk(clk),.q(q[1]),.data(d[1])); //explicit parameter redefinition dff u3 (q[2], ,d[2], clk); defparam u3.delay = 3.2; //in-line implicit parameter redefinition dff #(2) u4 (q[3], , d[3], clk); //in-line explicit parameter redefinition dff #(.delay(3)) u5 (q[3], , d[3], clk); endmodule module dff (output q, output qb, input data, input clk); parameter delay = 1; //default delay parameter dff_udp #(delay) (q, data, clk); not (qb, q); endmodule Array of Instances Example module tribuf64bit (output wire [63:0] out, input wire [63:0] in, input wire enable); //array of 8 8-bit tri-state buffers; each instance is connected //to 8-bit part selects of the 64-bit vectors; The scalar enable line //is connected to all instances tribuf8bit i[7:0] (out, in, enable); endmodule module tribuf8bit (output wire [7:0] y, input wire [7:0] a, input wire en); //array of 8 Verilog tri-state primitives; each bit of the //vectors is connected to a different primitive instance bufif1 u[7:0] (y, a, en); endmodule © Sutherland HDL, Inc. 19 8.0 Primitive Instances • delay (optional) represents the propagation delay through a primitive. The default delay is zero. Integers or real numbers may be used. • Separate delays for 1, 2 or 3 transitions may be specified. • Each transition may have a single delay or a min:typ:max delay range. • strength (optional) is specified as (strength1, strength0) or (strength0, strength1). The default is (strong1, strong0). Refer to section 4.9 for strength keywords. • Only gate primitives may have the output drive strength specified. Switch primitives pass the input strength level to the output. Resistive switches reduce the strength level as it passes through. • instance_name (optional) may used to reference specific primitives in configurations, debugging tools, schematic diagrams, etc. gate_type (drive_strength) #(delay) instance_name [instance_array_range] (terminal, terminal, ... ); switch_type #(delay) instance_name [instance_array_range] (terminal, terminal, ... ); Gate Primitives Terminal Order and Quantity and or xor nand nor xnor (1–output, 1-or-more–inputs) buf not (1-or-more–outputs, 1–input) bufif0 bufif1 notif0 notif1 (1–output, 1–input, 1–control) pullup pulldown (1–output) User Defined Primitive (1–output, 1-or-more–inputs) Switch Primitives Terminal Order and Quantity pmos rpmos nmos rnmos (1–output, 1–input, 1–control) cmos rcmos (1–output, 1–input, n-control, p-control) tran rtran (2–bidirectional-inouts) tranif0 rtranif0 tranif1 rtranif1 (2–bidirectional-inouts, 1–control) Delays Transitions represented (in order) 1 all output transitions 2 rise, fall output transitions 3 rise, fall, turn-off output transitions (turn-off delay is the time for a tri-state primitive to transition to Z) 20 Verilog HDL Quick Reference Guide • instance_array_range (optional) instantiates multiple primitives, each instance is connected to different bits of a vector. • The range is specified as [left-hand-index : right-hand-index]. • Primitive instances are connected with the right-most instance index connected to the right-most bit of each vector, and progressing to the left. • Vector signals must be the same size as the array. • Scalar signals are connected to all instances in the array. • Instance arrays were added in Verilog-1995, but many software tools did not support them until Verilog-2001. • Multiple instances of a primitive can also be created using a generate block (see section 9.0). Primitive Instance Examples Notes and i1 (out,in1,in2); zero delay gate primitive and #5 (o,i1,i2,i3,i4); same delay for all transitions not #(2,3) u7 (out,in); separate rise & fall delays buf (pull0,strong1)(y,a); output drive strengths wire [31:0] y, a; buf #2.7 i[31:0] (y,a); array of 32 buffers © Sutherland HDL, Inc. 21 9.0 Generate Blocks Generate blocks provide control over the creation of many types of module items. A generate block must be defined within a module, and is used to generate code within that module. Generate blocks were added in Verilog-2001. • genvar is an integer variable which must be a positive value. They may only be used within a generate block. Genvar variables only have a value during elaboration, and do not exist during simulation. Genvar variables must be declared within the module where the genvar is used. They may be declared either inside or outside of a generate block. • generate_items are: genvar_name = constant_expression; net_declaration variable_declaration module_instance primitive_instance continuous_assignment procedural_block task_definition function_definition if (constant_expression) generate_item or generate_item_group if (constant_expression) generate_item or generate_item_group else generate_item or generate_item_group case (constant_expression) genvar_value : generate_item or generate_item_group genvar_value : generate_item or generate_item_group ... default: generate_item or generate_item_group endcase for (genvar_name = constant_expression; constant_expression; genvar_name = constant_expression) generate_item or generate_item_group • generate_item_group is: begin: generate_block_name generate_item generate_item ... end genvar genvar_name, ... ; generate genvar genvar_name, ... ; generate_items endgenerate 22 Verilog HDL Quick Reference Guide • A generate for loop permits one or more generate items to be instantiated multiple times. The index loop variable must be a genvar. • A generate if—else or case permits generate items to be conditionally instantiated based on an expression that is deterministic at the time the design is elaborated. • generate_block_name (optional) is used to create a unique instance name for each generated item. • Task and function definitions are permitted within the generate scope, but not in a generate for-loop. That is, only one definition of the task or function can be generated. Generate Block Examples /* If the input bus widths are 8-bits or less, generate an instance of a carrylook-ahead multiplier. If the input bus widths are greater than 8-bits, generate an instance of a wallace-tree multiplier */ module multiplier (a, b, product); parameter a_width = 8, b_width = 8; localparam product_width = a_width + b_width; input [a_width-1:0] a; input [b_width-1:0] b; output [product_width-1:0] prod; generate if ((a_width < 8) || (b_width < 8)) CLA_mult #(a_width, b_width) m (a, b, prod); else WALLACE_mult #(a_width, b_width) m (a, b, prod); endgenerate endmodule /* A parameterized gray-code to binary-code converter using a loop to generate a continuous assignment for each bit of the converter */ module gray2bin1 (bin, gray); parameter SIZE = 8; output [SIZE-1:0] bin; input [SIZE-1:0] gray; genvar i; generate for (i=0; i> m >> n shift m right n-times and fill with zeros Unary Reduction Operators & &m AND all bits in m together (1-bit result) ~& ~&m NAND all bits in m together (1-bit result) | |m OR all bits in m together (1-bit result) ~| ~|m NOR all bits in m together (1-bit result) ^ ^m exclusive-OR all bits in m (1-bit result) ~^ or ^~ ~^m exclusive-NOR all bits in m (1-bit result) Logical Operators ! !m is m not true? (1-bit True/False result) && m && n are both m and n true? (1-bit True/False result) || m || n are either m or n true? (1-bit True/False result) Equality and Relational Operators (return X if an operand has X or Z) == m == n is m equal to n? (1-bit True/False result) != m != n is m not equal to n? (1-bit True/False result) < m < n is m less than n? (1-bit True/False result) > m > n is m greater than n? (1-bit True/False result) <= m <= n is m less than or equal to n? (1-bit True/False result) >= m >= n is m greater than or equal to n? (1-bit True/False result) Identity Operators (compare logic values 0, 1, X, and Z) === m === n is m identical to n? (1-bit True/False results) !== m !== n is m not identical to n? (1-bit True/False result) Miscellaneous Operators ? : sel?m:n conditional operator; if sel is true, return m: else return n {} {m,n} concatenate m to n, creating a larger vector {{}} {n{ }} replicate inner concatenation n-times –> -> m trigger an event on an event data type 30 Verilog HDL Quick Reference Guide 12.1 Operator Expansion Rules As a general rule, all operands in an expression are first expanded to the size of the largest vector in the statement (including both sides of an assignment statement). Concatenate and replicate operations are evaluated before the expansion, and represent a new vector size. • Unsigned operands are expanded by left-extending with zero. • Signed operands are expanded by left-extending with the value of the mostsignificant bit (the sign bit). 12.2 Arithmetic Operation Rules For most operators (there are exceptions) all operands in the expression are used to determine how the operation is performed: • If any operand is real, then floating-point arithmetic will be performed. • If any operand is unsigned, then unsigned arithmetic will be performed. • If all operands are signed, then signed arithmetic will be performed. • An operand can be “cast” to signed or unsigned using the $signed and $unsigned system functions (added in Verilog-2001). 12.3 Operator Precedence Compound expressions are evaluated in the order of operator precedence. Operators within parenthesis have a higher precedence and are evaluated first. Arithmetic Operators + m + n add n to m – m - n subtract n from m – -m negate m (2’s complement) * m * n multiply m by n / m / n divide m by n % m % n modulus of m / n ** m ** n m to the power n (new in Verilog-2001) <<< m <<< n shift m left n-times, filling with 0 (new in Verilog-2001) >>> m >>> n shift m right n-times; fill with value of sign bit if expression is signed, otherwise fill with 0 (Verilog-2001) ! ~ + – (unary) highest precedence {} {{}} () ** * / % + – (binary) << >> <<< >>> < <= > >= == != === !== & ~& ^ ~^ | ~| && || ?: lowest precedence © Sutherland HDL, Inc. 31 13.0 Task Definitions Tasks are analogous to subroutines in other languages. • Must be declared within a module, and are local to that module. • Must be called from an initial procedure, an always procedure or another task. • May have any number of input, output or inout ports, including none. • Tasks may contain time controls (#, @, or wait). automatic (optional) allocates storage space each time the task is called, allowing the task to be re-entrant (the task can be called while previous calls to the task are still executing). Automatic tasks were added in Verilog-2001. port_declaration can be: • port_direction signed range • port_direction reg signed range • port_direction port_type port_direction can be input, output or inout. range (optional) is a range from [msb :lsb] (most-significant-bit to leastsignificant-bit). msb and lsb must be a literal number, a constant, an expression, or a call to a constant function. If no range is specified, the ports are 1-bit wide. port_type can be integer, time, real or realtime. signed (optional) indicates that values are interpreted as 2’s complement signed values. ANSI-C Style Task Declaration (added in Verilog-2001) task automatic task_name ( port_declaration port_name, port_name, ... , port_declaration port_name, port_name, ... ); local variable declarations procedural_statement or statement_group endtask Old Style Task Declaration (port declarations determine the order signals are passed in/out of the task) task automatic task_name; port_declaration port_name, port_name, ...; port_declaration port_name, port_name, ...; local variable declarations procedural_statement or statement_group endtask Example of a Task //TASK DEFINITION (must be declared within a module) task read_mem (input [15:0] address, output [31:0] data ); begin read_request = 1; wait (read_grant) addr_bus = address; data = data_bus; #5 addr_bus = 16'bz; read_request = 0; end endtask //TASK CALL always @(posedge clock) read_mem(PC, IR); 32 Verilog HDL Quick Reference Guide 14.0 Function Definitions Functions: • Must be declared within a module, and are local to that module. • Return the value assigned to the function name. • May be called any place an expression value can be used. • Must have at least one input; may not have outputs or inouts. • May not contain time controls or non-blocking assignments. automatic (optional) allocates storage space for each function call, allowing recursive function calls. Automatic functions were added in Verilog-2001. range_or_type (optional) is the function return type or input type. The default is a 1-bit reg. range_or_type can be: • signed [msb :lsb] • reg signed [msb :lsb] • integer, time, real or realtime signed (optional) indicates that the return value or input values are interpreted as 2’s complement signed values. Signed functions were added in Verilog-2001. 14.1 Constant Functions Constant functions (new in Verilog-2001) are functions with restrictions so that the function can be evaluated at elaboration (before simulation starts running). • Only locally declared variables can be referenced. Net types cannot be used. • Parameter values used within the function must be defined before the function is called. Parameter values should not be redefined using defparam. • Can call other constant functions, but not in a context where a constant expression is required (such as to declare port sizes). • System function calls are illegal. System task calls are ignored. • Hierarchical references are illegal. ANSI-C Style Function Declaration (added in Verilog-2001) function automatic range_or_type function_name ( input range_or_type port_name, port_name, ... , input range_or_type port_name, port_name, ... ); local variable declarations procedural_statement or statement_group endfunction Old Style Function Declaration (port declarations determine the order signals are passed into the function) function automatic [range_or_type] function_name; input range_or_type port_name, port_name, ... ; input range_or_type port_name, port_name, ... ; local variable declarations procedural_statement or statement_group endfunction Example of a Function function automatic [63:0] factorial (input reg [31:0] n); if (n<=1) factorial = 1; else factorial = n * factorial(n-1); //recursive call endfunction if ( factorial(data) <= LIMIT ) //function call © Sutherland HDL, Inc. 33 15.0 Specify Blocks 15.1 Pin-to-pin Path Delays • Simple path delay statement: (input_port polarity:path_token output_port ) = (delay); • Edge-sensitive path delay: (edge input_port path_token (output_port polarity:source)) = (delay); • edge (optional) may be either posedge or negedge. If not specified, all input transitions are used. • source (optional) is the input port or value the output will receive. The source is ignored by most logic simulators, but may be used by timing analyzers. • State-dependent path delay: if (first_condition) simple_or_edge-sensitive_path_delay if (next_condition) simple_or_edge-sensitive_path_delay ifnone simple_path_delay • Different delays for the same path can be specified. • condition may only be based on input ports. • Most operators may be used, but should resolve to true/false (X or Z is considered true; if the condition resolves to a vector, only the lsb is used). • Each delay for the same path must have a different condition or a different edge-sensitive edge. • The ifnone condition (optional) may only be a simple path delay, and serves as a default if no other condition evaluates as true. • polarity (optional) is either + or –. A – indicates the input will be inverted. Polarity is ignored by most simulators, but may be used by timing analyzers. • path_token is either *> for full connection or => for parallel connection. • Parallel connection indicates each input bit of a vector is connected to its corresponding output bit (bit 0 to bit 0, bit 1 to bit 1, ...) • Full connection indicates an input bit may propagate to any output bit. • Separate delay sets for 1, 2, 3, 6 or 12 transitions may be specified. • Each delay set may have a single delay or a min:typ:max delay range. specify specparam_declarations (see 6.3) simple_pin-to-pin_path_delay edge-sensitive_pin-to-pin_path_delay state-dependent_pin-to-pin_path_delay timing_constraint_checks endspecify Delays Transitions represented (in order) 1 all output transitions 2 rise, fall output transitions 3 rise, fall, turn-off output transitions 6 rise, fall, 0–>Z, Z–>1, 1–>Z, Z–>0 12 rise, fall, 0->Z, Z->1, 1->Z, Z->0, 0->X, X->1, 1->X, X->0, X->Z, Z->X 34 Verilog HDL Quick Reference Guide 15.2 Path Pulse (Glitch) Detection A pulse is a glitch on the inputs of a module path that is less than the delay of the path. A special specparam constant can be used to control whether the pulse will propagate to the output (transport delay), not propagate to the output (inertial delay), or result in a logic X on the output. specparam PATHPULSE$input$output = (reject_limit, error_limit); specparam PATHPULSE$ = (reject_limit, error_limit); • reject_limit is a delay value, or min:typ:max delay set, that is less than or equal to the delay of a module path. Any pulse on the input that is less than or equal to the reject limit will be cancelled (not propagate to the output). • error_limit is a delay value, or min:typ:max delay set, that is greater than or equal to the reject_limit and less than or equal to the delay of a module path. Any pulse on the input greater than the error_limit will propagate to the output. Any pulse less than or equal to the error_limit and greater than the reject_limit will be propagated as a logic X to the output. • A PATHPULSE$ specparam with no input to output path applies to all module paths that do not have a specific PATHPULSE$ specparam. • A single limit can be specified, in which case the reject and error limits will be the same. The parenthesis can be omitted when there is a single value. Verilog-2001 adds the following reserved words which can be used within a specify block for greater pulse propagation accuracy. pulsestyle_onevent list_of_path_outputs; Indicates that a pulse propagates to a path output as an X, with the same delay as if a valid input change had propagated to the output. This is the default behavior, and matches Verilog-1995. pulsestyle_ondetect list_of_path_outputs; Indicates that as soon as a pulse is detected, a logic X is propagated to a path output, without the path delay. (continued on next page) Path Delay Examples Notes (a => b) = 1.8; parallel connection path; one delay for all output transitions (a -*> b) = 2:3:4; full connection path; one min:typ:max delay range for all output transitions; b receives the inverted value of a specparam t1 = 3:4:6, t2 = 2:3:4; (a => y) = (t1,t2); different path delays for rise, fall transitions (posedge clk => (qb -: d)) = (2.6, 1.8); edge-sensitive path delay; timing path is positive edge of clock to qb; qb receives the inverted value of data if (rst && pst) (posedge clk=>(q +: d))=2; state-dependent edge sensitive path delay if (opcode = 3'b000) (a,b *> o) = 15; if (opcode = 3'b001) (a,b *> o) = 25; ifnone (a,b *> o) = 10; state-dependent path delays; an ALU with different delays for certain operations (default delay has no condition) © Sutherland HDL, Inc. 35 showcancelled list_of_path_outputs; Indicates that a negative pulse, where the trailing edge of the pulse occurs before the leading edge, will not propagate to the output. This is the default behavior, and matches Verilog-1995. noshowcancelled list_of_path_outputs; Indicates that negative pulses propagate to the output as a logic X. 15.3 Timing Constraint Checks Timing constraint checks are special tasks that model restrictions on input changes, such as setup times and hold times. Timing checks measure the delta between a reference_event and a data_event. • data_event and reference_event signals must be module input ports. • limit is a constant expression that represents the amount of time that must be met for the constraint. The expression can be a min:typ:max delay set. • notifier (optional) is a 1-bit reg variable that is automatically toggled whenever the timing check detects a violation. • stamptime_condition (optional) and checktime_condition (optional) are conditions for enabling or disabling negative timing checks. These arguments were added in Verilog-2001. • delayed_ref (optional) and delayed_data (optional) are delayed signals for negative timing checks. These arguments were added in Verilog-2001. • event_based_flag (optional) when set, causes the timing check to be event based instead of timer based. This argument was added in Verilog-2001. • remain_active_flag (optional) wen set, causes the timing check to not become inactive after the first violation is reported. This argument was added in Verilog-2001. • start_edge_offset and end_edge_offset are delay values (either positive or negative) which expand or reduce the time in which no change can occur. • $recrem, $timeskew and $fullskew were added in Verilog-2001. $setup(data_event, reference_event, limit, notifier); $hold(reference_event, data_event, limit, notifier); $setuphold(reference_event, data_event, setup_limit, hold_limit, notifier, stamptime_condition, checktime_condition, delayed_ref, delayed_data); $recovery(reference_event, data_event, limit, notifier); $removal(reference_event, data_event, limit, notifier); $recrem(reference_event, data_event, recovery_limit, removal_limit, notifier, stamptime_cond, checktime_cond, delayed_ref, delayed_data); $skew(reference_event, data_event, limit, notifier); $timeskew(reference_event, data_event, limit, notifier, event_based_flag, remain_active_flag); $fullskew(reference_event, data_event, data_skew_limit, ref_skew_limit, notifier, event_based_flag, remain_active_flag); $period(reference_event, limit, notifier); $width(reference_event, limit, width_threshold, notifier); $nochange(reference_event, data_event, start_edge_offset, end_edge_offset, notifier); 36 Verilog HDL Quick Reference Guide 16.0 User Defined Primitives (UDPs User Defined Primitives define new primitives, which are used exactly the same as built-in primitives. • All terminals must be scalar (1-bit). • Only one output is allowed, which must be the first terminal. • The maximum number of inputs is at least 9 inputs for a sequential UDP and 10 inputs for a combinational UDP. • Logic levels of 0, 1, X and transitions between those values may be represented in the table. The logic value Z is not supported with UDPs. A Z value on a UDP input is treated as an X value. • reg declaration (optional) defines a sequential UDP by creating internal storage. Only the output may be declared a reg. • initial (optional) is used to define the initial (power-up) state for sequential UDP's. Only the logic values 0, 1, and X may be used. The default state is X. In Verilog-2001, the initial value can be assigned in the declaration. 16.1 UDP Table Entries input_logic_values : output_logic_value ; • Combinational logic table entry. Only logic level values may be specified (0, 1, X and don’t cares). input_logic_values : previous_state : output_logic_value ; • Sequential logic table entry. May only be used when the output is also declared as a reg data type. Both input logic level and input logic transition values may be specified. • A white space must separate each input value in the table. • The input values in the table must be listed in the same order as the terminal list in the primitive statement. • Any combination of input values not specified in the table will result in a logic X (unknown) value on the output. ANSI-C Style Port List (added in Verilog-2001) primitive primitive_name ( output reg = logic_value terminal_declaration, input terminal_declarations ); table table_entry; table_entry; endtable endprimitive Old Style Port List primitive primitive_name (output, input, input, ... ); output terminal_declaration; input terminal_declarations; reg output_terminal; initial output_terminal = logic_value; table table_entry; table_entry; endtable endprimitive © Sutherland HDL, Inc. 37 • Only one signal may have an edge transition specified for each table entry. • If an edge transition is specified for one input, the UDP becomes sensitive to transitions on all inputs. Therefore, all other inputs must have table entries to cover transitions, or when the transition occurs the UDP will output an X. • Level sensitive entries have precedence over edge sensitive table entries. 16.2 UDP Table Symbols Truth Table Symbol Definition 0 logic 0 on input or output 1 logic 1 on input or output x or X unknown on input or output – no change on output (sequential UDPs only) ? don't care if an input is 0, 1, or X b or B don't care if and input is 0 or 1 (vw) input transition from logic v to logic w e.g.: (01) represents a transition from 0 to 1 r or R rising input transition: same as (01) f or F falling input transition: same as (10) p or P positive input transition: (01), (0X) or (X1) n or N negative input transition: (10), (1X) or (X0) * Any possible input transition: same as (??) UDP Examples primitive mux (y, a, b, sel); //COMBINATIONAL UDP output y; input sel, a, b; table //Table order for inputs // a b sel : y //matches primitive statement 0 ? 0 : 0; //select a; don’t care on b 1 ? 0 : 1; //select a; don’t care on b ? 0 1 : 0; //select b; don’t care on a ? 1 1 : 1; //select b; don’t care on a endtable endprimitive primitive dff //SEQUENTIAL UDP (output reg q = 0, input clk, rst, d ); table // d clk rst:state:q ? ? 0 : ? :0; //low true reset 0 R 1 : ? :0; //clock in a 0 1 R 1 : ? :1: //clock in a 1 ? N 1 : ? :-; //ignore negedge of clk * ? 1 : ? :-; //ignore all edges on d ? ? P : ? :-; //ignore posedge of rst 0 (0X) 1 : 0 :-; //reduce pessimism 1 (0X) 1 : 1 :-; //reduce pessimism endtable endprimitive 38 Verilog HDL Quick Reference Guide 17.0 Common System Tasks and Functions • System tasks and functions begin with a $ (dollar sign). • The IEEE 1364 Verilog standard defines a number of standard system task and system functions. • Software tool vendors may define additional proprietary system tasks and functions specific to their tool, such as for waveform displays. • Simulator users may define additional system tasks and functions using the Verilog Programming Language Interface (PLI). 17.1 Text Output System Tasks $display(“text_with_format_specifiers”, list_of_arguments); $displayb(“text_with_format_specifiers”, list_of_arguments); $displayo(“text_with_format_specifiers”, list_of_arguments); $displayh(“text_with_format_specifiers”, list_of_arguments); Prints the formatted message when the statement is executed. A newline is automatically added to the message. If no format is specified, the routines default to decimal, binary, octal and hexadecimal formats, respectively. $write(“text_with_format_specifiers”, list_of_arguments); $writeb(“text_with_format_specifiers”, list_of_arguments); $writeo(“text_with_format_specifiers”, list_of_arguments); $writeh(“text_with_format_specifiers”, list_of_arguments); Like $display statement, except that no newline is added. $strobe(“text_with_format_specifiers”, list_of_arguments); $strobeb(“text_with_format_specifiers”, list_of_arguments); $strobeo(“text_with_format_specifiers”, list_of_arguments); $strobeh(“text_with_format_specifiers”, list_of_arguments); Like the $display statement, except that the printing of the text is delayed until all simulation events in the current simulation time have executed. $monitor(“text_with_format_specifiers”, list_of_arguments); $monitorb(“text_with_format_specifiers”, list_of_arguments); $monitoro(“text_with_format_specifiers”, list_of_arguments); $monitorh(“text_with_format_specifiers”, list_of_arguments); Invokes a background process that continuously monitors the arguments listed, and prints the formatted message whenever one of the arguments changes. A newline is automatically added to the message. Text Formatting Codes %b %o %d %h %e %f %t %s binary values octal values decimal values hex values real values–exponential real values–decimal formatted time values character strings %m %l \t \n \” \\ %% hierarchical name of scope configuration library binding print a tab print a newline print a quote print a backslash print a percent sign %0b, %0o, %0d and %0h truncates any leading zeros in the value. %e and %f may specify field widths (e.g. %5.2f ). %m and %l do not take an argument; they have an implied argument value. The format letters are not case sensitive (i.e. %b and %B are equivalent). © Sutherland HDL, Inc. 39 17.2 File I/O System Tasks and Functions mcd = $fopen(“file_name”); fd = $fopen(“file_name”, type); A function that opens a disk file for writing, and returns an integer value. • mcd is a multi-channel-descriptor with a single bit set. Multiple mcd’s can be or’ed together to write to multiple files at the same time. An mcd file is always opened as a new file for writing only. Bit 0 is reserved and represents the simulator’s output window. Bit 31 is reserved and represents that the channel is an fd, not an mcd. • fd is a single-channel descriptor which has multiple bits set; bit 31 and at least one other bit will be set. An fd file can be opened for either reading or writing, and can be opened in append mode. Only one file can be read or written to at a time using an fd. The fd was added in Verilog-2001. • type is one of the following character strings: $fclose(mcd_or_fd); Closes a disk file that was opened by $fopen. $fmonitor(mcd_or_fd, “text with format specifiers”, signal, signal,...); $fdisplay(mcd_or_fd, “text with format specifiers”, signal, signal,...); $fwrite(mcd_or_fd, “text with format specifiers”, signal, signal,...); $fstrobe(mcd_or_fd, “text with format specifiers”, signal, signal,...); Variations of the text display tasks that write to files. Verilog-2001 adds several system functions similar to C file I/O functions: c = $fgetc(fd); code = $ungetc(c, fd); code = $fgets(str, fd); code = $fscanf(fd, format, arguments); code = $fread(reg_variable, fd); code = $fread(memory_array, fd, start, count); position = $ftell(fd); code = $fseek(fd, offset, operation); code = $rewind(fd); errno = $ferror(fd, str); $fflush(mcd_or_fd); 17.3 Other Common System Tasks and Functions $finish(n); Finishes a simulation and exits the simulation process. n (optional) is 0, 1 or 2, and may cause extra information about the simulation to be displayed. $stop(n); Halts a simulation and enters an interactive debug mode. “r” or “rb” open for reading “w” or “wb” truncate to zero length or create for writing “a” or “ab” append; open for writing at end of file “r+”, “r+b”, or “rb+” open for update (reading and writing) “w+”, “w+b”, or “wb+” truncate or create for update “a+”, “a+b”, or “ab+” append; open or create for update at end-of-file 40 Verilog HDL Quick Reference Guide $time $stime $realtime Returns the current simulation time as a 64-bit vector, a 32-bit integer or a real number, respectively. $timeformat(unit, precision, “suffix”, min_field_width); Controls the format used by the %t text format specifier. • unit is the base that time is to be displayed in, where: • precision is the number of decimal points to display. • suffix is a string appended to the time, such as “ ns”. • min_field_width is the minimum number of characters to display. Example: $timeformat (-9, 2, “ns”, 10); $printtimescale(module_hierarchical_name); Prints the time scale of the specified module, or the scope from which it is called if no module is specified. signed_value = $signed(unsigned_value) unsigned_value = $unsigned(signed_value) Converts a value to or from a signed value; affects math operations and sign extension. These system functions were added in Verilog-2001. $swrite(reg_variable, format, arguments, format, arguments,...); $swriteb(reg_variable, format, arguments, format, arguments,...); $swriteo(reg_variable, format, arguments, format, arguments,...); $swrited(reg_variable, format, arguments, format, arguments,...); $sformat(reg_variable, format, arguments); Similar to $write, except that the string is written to the reg variable instead of to a file. These system tasks and functions were added in Verilog-2001. code = $sscanf(str, format, arguments); Similar to $fscanf, but reads values from a string. Added in Verilog-2001. $readmemb(“file_name”, variable_array, start_address, end_address); $readmemh(“file_name”, variable_array, start_address, end_address); Loads the contents of a file into a memory array. The file must be an ASCII file with values represented in binary ($readmemb) or hex ($readmemh). Start and end address are optional. 64-bit_reg_variable = $realtobits(real_variable); real_variable = $bitstoreal(64-bit_reg_variable); Converts double-precision real variables to and from 64 bit reg vectors, so that the real value can be passed through 64-bit ports. integer = $test$plusargs(“invocation_option”) integer = $value$plusargs(“invocation_option=format”, variable) Tests the invocation command line for the invocation option. The option must begin with a + on the command line, but the + is not included in the string. If found, the routines return a non-zero value. $value$plusargs converts any text following the string up to a white space to the format specified, and puts the value into the second argument. Allowable formats are %b, %o, %d, %h, %e, %f, %g and %s. 0 -1 -2 -3 = = = = 1sec 100ms 10ms 1ms -4 -5 -6 = = = 100us 10us 1us -7 -8 -9 = = = 100ns 10ns 1ns -10 -11 -12 = = = 100ps 10ps 1ps -13 -14 -15 = = = 100fs 10fs 1fs © Sutherland HDL, Inc. 41 18.0 Common Compiler Directives Compiler directives provide a method for software tool vendors to control how their tool will interpret Verilog HDL models. • Compiler directives begin with the grave accent character ( ` ). • Compiler directives are not Verilog HDL statements; there is no semi-colon at the end of compiler directives. • Compiler directives are not bound by modules or by files. When a tool encounters a compiler directive, the directive remains in effect until another compiler directive either modifies it or turns it off. `resetall Resets all compiler directives that have a default back to their default. Directives that have no default are not affected. `timescale time_unit base / precision base Specifies the time units and precision for delays: • time_unit is the amount of time a delay of 1 represents. The time unit must be 1, 10, or 100 • base is the time base for each unit, ranging from seconds to femtoseconds, and must be: s ms us ns ps or fs • precision and base represent how many decimal points of precision to use relative to the time units. Example: `timescale 1 ns / 10 ps Indicates delays are in 1 nanosecond units with 2 decimal points of precision (10 ps is .01 ns). Note: There is no default timescale in Verilog; delays are simply relative numbers until a timescale directive declares the units and base the numbers represent. `define macro_name text_string `define macro_name (arguments) text_string (arguments) Text substitution macro. Allows a text string to be defined as a macro name. • text_string will be substituted in place of the macro_name where ever the macro name is used. • text_string is terminated by a carriage return—the string must be on one line. • arguments are evaluated before text is substituted. • The macro_name must also be preceded by the grave accent mark ( ` ) each time the macro name is used. • Comments may be used—they are not substituted into the place of the macro name. Examples: `define cycle 20 //clock period always #(`cycle/2) clk = ~clk; `define NAND(dval) nand #(dval) `NAND(3) i1 (y,a,b); `NAND(3:4:5) i2 (o,c,d); `undef macro_name Removes the definition of a macro name. 42 Verilog HDL Quick Reference Guide `ifdef macro_name `ifndef macro_name verilog_source_code `else verilog_source_code `elsif verilog_source_code `endif Conditional compilation. Allows Verilog source code to be optionally included, based on whether or not macro_name has been defined using the `define compiler directive or the +define+ invocation option. The ‘ifndef and ‘elsif directives were added in Verilog-2001. Example: `ifdef RTL wire y = a & b; `else and #1 (y,a,b); `endif `include “file_name” File inclusion. The contents of another Verilog HDL source file is inserted where the `include directive appears. `celldefine `endcelldefine Flags the Verilog source code between the two directives as a cell. Some tools, such as a delay calculator for an ASIC, need to distinguish between a module that represents an ASIC cell and other modules in the design. `default_nettype net_data_type `default_nettype none Changes the net data type to be used for implicit net declarations. Any of the net data types may be specified. By default, the implicit net data type is wire. If none is specified, then implicit net declarations are disabled, and all nets must be explicitly declared (specifying none was added in Verilog-2001). `unconnected_drive pull1 `unconnected_drive pull0 `nounconnected_drive Determines what logic value will be applied to unconnected module inputs. The default is `nounconnected_drive, meaning unconnected inputs and nets float at high impedance. `uselib file= dir= libext= Specifies the Verilog source library file or directory in which the compiler should search for the definitions of modules or UDPs instantiated in a design. A `uselib directive with no arguments removes any preceding library search directives. Note: This directive is not part of the IEEE 1364 Verilog standard, but is implemented in most Verilog simulators. Example: `uselib file=/models/rtl_lib ALU i1 (y1,a,b,op); //RTL model `uselib dir=/models/gate_lib libext=.v ALU i2 (y2,a,b,op); //Gate model `uselib //turn off `uselib searching © Sutherland HDL, Inc. 43 19.0 Configurations Configurations (added in Verilog-2001) are a set of rules to specify the exact source description to be used for each module or primitive instance in a design. The configuration block is Verilog source code; it can be compiled along with the Verilog model source code. • Verilog designs are modeled the same as in Verilog-1995. • Configuration blocks are specified outside of module boundaries. The blocks can be in the same files as the Verilog source code, or they can be in separate files. • A cell is the name of a module, primitive or another configuration. • Symbolic library names are used within the configuration block. A symbolic library is a logical collection of cells. The cell name must be the same as the name of the module, primitive or configuration. • library map files are used to map the symbolic library names to physical file locations. • The library binding information for module instances can be displayed during simulation using the format specifier %l, which will print the library_name.cell_name of the module containing the print statement. 19.1 Configuration Blocks The config—endconfig is a design element, similar to a module, and exists in the same Verilog name space as module and primitive names. The configuration block contains a set of rules for searching for the Verilog source description to bind to a particular instance of the design. • design specifies the library and cell of the top-level module or modules in the design hierarchy. There can only be one design statement, but multiple top-level modules can be listed. The design statement must the first statement in the configuration. • lib_name. (optional) specifies which symbolic library contains the cell. If the library name is omitted, then the library which contains the config is used to search for the cell. • cell_name (required) is the name of the module that is the top of the design hierarchy represented by the configuration. • default liblist specifies in which libraries to search for all instances which do not match a more specific selection clause. The libraries are searched in the order listed. For many designs, the default liblist may be all that is needed to specify the configuration. • list_of_library_names is a comma-separated list of symbolic library names. config config_name; design lib_name.cell_name; default liblist list_of_library_names; cell lib_name.cell_name liblist list_of_library_names; cell lib_name.cell_name use lib_name.cell_name:config_name; instance hierarchy_name liblist list_of_library_names; instance hierarchy_name use lib_name.cell_name:config_name; endconfig 44 Verilog HDL Quick Reference Guide • cell specifies a specific set of libraries in which to search for the source code for that module or primitive name, instead of the libraries and order specified in the default statement. • lib_name. (optional) specifies which symbolic library contains the cell. • cell_name (required) is the name of a module or primitive. • instance specifies a specific set of libraries in which to search for the source code for that specific module or primitive instance, instead of the libraries and/or order specified in the default statement. • hierarchy_name is the full hierarchy path name of an instance of a module or primitive. The hierarchy path must start with the name specified in the design statement. • use (optional) specifies the location for a specific cell or instance of a cell, instead of searching a for the cell in the default libraries. • lib_name. (optional) specifies which symbolic library contains the cell. • :config_name (optional) specifies that a different configuration block should be used for the specified instance or cell. The design statement in that configuration specifies the actual binding information. 19.2 Library Map Files A separate file is used to map symbolic libraries to the physical file locations. • The library map file contains library statements, include statements and Verilog-style comments. • The map file is not Verilog source code. • If the source files are moved, only the map file needs to be modified; The Verilog source code and configuration blocks do not need to be changed. • lib_name defines the symbolic library name which will be reference in configuration blocks. • list_of_file_paths is a comma-separated list of operating system paths to one or more directories or specific files. • A path which ends in / includes all files in the specified directory (identical to a path which ends with /*). • A path which does not begin with / is relative to the directory in which the current library map file is located. • Special symbols can be used in the path: • -incdir specifies where to search for files referenced by `include directives in the Verilog source code. • include library_map_file_path allows one library map file to reference another library map file. library lib_name list_of_file_paths, -incdir list_of_file_paths; include library_map_file_path; ? single character wild card (matches any single character) * multiple character wild card (matches any number of characters) ... hierarchical wild card (matches any number of hierarchical directories) .. specifies the parent directory . specifies the directory containing the lib.map © Sutherland HDL, Inc. 45 20.0 Synthesis Supported Constructs Following is a list of Verilog HDL constructs supported by most synthesis tools. The list is based on a preliminary draft of the IEEE 1364.1 “Verilog Register Transfer Level Synthesis” standard (this standard was not complete at the time this reference guide was written). The list is not specific to any one tool—each synthesis tool supports a unique subset of the Verilog language. Verilog HDL Constructs Notes module declarations fully supported port declarations input output inout fully supported; any vector size supported net data types wire wand wor supply0 supply1 scalars and vectors fully supported variable data types reg integer • may be scalar or vector or variable array • may be restricted to only making assignments to a variable from just one procedure • integers default to 32 bits parameter constants limited to integers; parameter redefinition may not be supported literal integer numbers fully supported; all sizes and bases module instances fully supported; both port order and port name instantiation supported primitive instances and nand or nor xor buf not bufif1 bufif0 notif1 notif0 fully supported assign continuous assignment fully supported; both explicit and implicit forms are supported assign procedural continuous assignment fully supported, but the deassign keyword may not be supported function definitions may only use supported constructs task definitions may only use supported constructs always procedural block must have a sensitivity list begin—end statement groups fully supported; both named and unnamed blocks are supported; fork—join statement groups are not supported = blocking procedural assignment <= non-blocking procedural assignment fully supported; may be restricted to using only one type of assignment for all assignments to the same variable 46 Verilog HDL Quick Reference Guide New constructs in the Verilog-2001 standard that are expected to be supported by synthesis: • Comma-separated sensitivity lists • @* combinational logic sensitivity • Combined port/data type declaration • ANSI C style port declarations • Implicit nets with continuous assignments • Multi-dimensional arrays • Array bit and part selects • Signed data types • Signed literal numbers • <<<, >>> arithmetic shifts • ** power operator (may have restrictions) • Recursive functions (the number of recursions must be able to be determined at elaboration time) • Sized parameters • Explicit in-line parameter passing • ‘ifndef and ‘elsif compiler directives if if—else case casex casez decision statements logic X and Z only supported as “don’t care” bits for loops the step assignment must be an increment or decrement (+ -) while loops forever loops loop must take one clock cycle for each loop cycle (i.e.: an @(posedge clk) or @(negedge clk) must be within the loop) disable statement group must be used within the same named block that is being disabled operators & ~& | ~| ^ ^~ ~^ == != < > <= => ! && || << >> {} {{}} ?: + - * / operands may be: • scalar or vector • constant or variable • the === and !== operators are not supported vector bit selects vector part selects fully supported on the right-hand side of an assignment; restricted to constant bit or part selects on the left-hand side of an assignment Verilog HDL Constructs Notes © Sutherland HDL, Inc. 47 Notes: Index 48 Symbols ! .....................................................28 != ...................................................28 !== .................................................28 # ..............................................16, 23 $ (system tasks/functions) .............37 $ (timing checks) ..........................34 % (modulus operator) ...................29 % (text format codes) ....................37 & ...................................................28 && ................................................28 (* .....................................................3 * ....................................................29 *) .....................................................3 ** ..................................................29 */ .....................................................3 *> ..................................................32 + ..............................................29, 32 - ...............................................29, 32 -> ...................................................28 -incdir ............................................43 / .....................................................29 /* .....................................................3 // ......................................................3 < ....................................................28 << ..................................................28 <<< ................................................29 <= ............................................24, 28 = ....................................................24 == ..................................................28 === ................................................28 => ..................................................32 > ....................................................28 >= ..................................................28 >> ..................................................28 >>> ................................................29 ? .......................................................6 ?: ....................................................28 @ ...................................................23 @* .................................................23 \ (escaped identifiers) ......................4 ^ .....................................................28 ^~ ..................................................28 { } ..................................................28 {{ }} ..............................................28 | ..................................................... 28 || .................................................... 28 ~ .................................................... 28 ~& ................................................. 28 ~^ .................................................. 28 ~| ................................................... 28 ‘ (compiler directives) .................. 40 A always ........................................... 22 and ..........................................18, 28 arrays of instances ..............4, 16, 19 arrays of nets ..........................11, 15 arrays of variables ..................12, 15 assign ............................................ 24 attributes ......................................... 4 automatic ................................30, 31 B base ................................................. 6 begin .............................................22 binary radix ............................... 6, 37 blocking assignment ..................... 24 buf ................................................. 18 bufif0 ............................................ 18 bufif1 ............................................ 18 C case ............................................... 25 casex .............................................25 casez .............................................25 cell ..........................................41, 42 cmos .............................................. 18 comments ........................................ 3 compiler directives ....................... 40 concurrency .................................... 3 config ............................................ 42 configuration blocks ..................... 42 constant functions ......................... 31 continuous assignment ................. 27 D data type declarations ................... 10 data types ................................10, 12 deassign ........................................ 24 decimal radix ............................ 6, 37 default ........................................... 42 defparam ....................................... 16 49 Index delays ....................11, 18, 23, 32, 40 design ............................................42 disable ...........................................25 E else ................................................25 end .................................................22 endcase ..........................................25 endconfig ......................................42 endgenerate ...................................20 endprimitive ..................................35 endspecify .....................................32 endtask ....................................30, 31 escaped identifiers ...........................4 event ..............................................14 F for ..................................................25 force ..............................................24 forever ...........................................25 fork ................................................22 function .........................................31 G generate .........................................20 genvar ......................................14, 20 H hexadecimal ....................................6 hexadecimal radix .........................37 hierarchical path names ..................4 hierarchy .........................................4 highz0............................................1 5 highz1............................................1 5 I identifiers ........................................4 if ..............................................25, 32 ifnone ............................................32 include ...........................................43 initial .............................................22 inout ................................................8 input ................................................8 instance .........................................42 instance name ..........................16, 18 integer data type ............................12 integer numbers ...............................6 intra-assignment delay ..................24 J join 2................................................2 K keywords, list of .............................2 L large ................................................5 liblist .............................................42 library ...........................................43 localparam .................................... 14 logic strengths .................................5 logic values .....................................5 M medium 5 memories ....................12, 15, 38, 39 module definitions ..........................7 module instances ..........................16 N name space .....................................4 names ..............................................4 nand ..............................................18 negedge ...................................23, 32 net data types ................................10 nets ................................................10 nmos .............................................18 non-blocking assignment ..............24 nor .................................................18 not .................................................18 notif0 ............................................18 notif1 ............................................18 O octal radix .................................6, 37 operator precedence ......................29 operators, list of ............................28 or .......................................18, 23, 28 output ..............................................8 P parameter ................................14, 16 path delays ....................................32 path names ......................................4 pmos .............................................18 polarity ..........................................32 port declarations .............................8 posedge ...................................23, 32 Index 50 precision ........................................40 primitive definitions ......................35 primitive instances ........................18 procedural blocks ..........................22 pull0 ................................................5 pull1 ................................................5 pulldown .......................................18 pullup ............................................18 R radix ................................................6 rcmos .............................................18 re-entrant tasks ..............................30 real ................................................12 realtime .........................................12 recursive functions ........................31 reg .................................................12 release ...........................................24 repeat .............................................25 rnmos ............................................18 rpmos ............................................18 rtran ...............................................18 rtranif0 ..........................................18 rtranif1 ..........................................18 S scientific notation ............................5 scopes ..............................................4 sensitivity list ................................22 signed ................8, 11, 12, 14, 30, 31 signed arithmetic ...........................29 small ................................................5 specify blocks ...............................32 specparam .....................................14 strength ..........................5, 11, 18, 27 strong0 ............................................5 strong1 ............................................5 supply0 ......................................5, 10 supply1 ......................................5, 10 synthesis ........................................44 system tasks/functions ..................37 T task ................................................30 time controls .................................23 time data type ................................12 time units .......................................40 timing checks ................................ 34 tran ................................................ 18 tranif0 ........................................... 18 tranif1 ........................................... 18 transport delay .............................. 24 tri .................................................. 10 tri0 ................................................ 10 tri1 ................................................ 10 triand .............................................10 trior ............................................... 10 trireg .............................................10 U use ................................................. 42 User Defined Primitives .........18, 35 V variables ........................................ 12 W wait ............................................... 23 wand .............................................10 weak0 .............................................. 5 weak1 .............................................. 5 while .............................................25 wire ............................................... 10 wor ................................................ 10 X xnor .........................................18, 28 xor ...........................................18, 28 suggested retail: $14.95 A complete reference on the Verilog Hardware Description Language, covering the syntax and semantics of the Verilog HDL. Many examples illustrate how to use Verilog. Includes synthesis supported constructs, common system tasks and a list of what is new in the Verilog-2001 standard. Fully indexed for easy reference. published by Sutherland HDL, Incorporated 22805 SW 92nd Place Tualatin, OR 97062 (503) 692-0898 www.sutherland-hdl.com Sutherland HDL, Inc. provides expert Verilog and SystemVerilog training workshops Sutherland HDL also sells the Verilog PLI Quick Reference Guide, covering the Verilog Programming Language Interface. Verilog® HDL Quick Reference Guide based on the Verilog-2001 standard (IEEE Std 1364-2001) Sutherland HDL