Methodology of passive air sampling Roman Prokeš  Petra Přibylová  Kateřina Šebková  Jana Klánová  Ivan Holoubek          RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  1    Methodology of passive air sampling    Contents   1.  Sampler characterization ...................................................................................................................... 2  2.  Sampler deployment – site selection .................................................................................................... 4  3.  Installation and changing of PUF disk ................................................................................................... 5  3.1.  PUF disk installation ...................................................................................................................... 6  3.2.  PUF disk changing .......................................................................................................................... 9  4.  Transport and storage of PUF disk ...................................................................................................... 13                        CITATION:  Prokeš,  R.,  Přibylová,  P.,  Šebková,  K.,  Klánová,  J.,  Holoubek,  I.,  Methodology  of  Passive  Air  Sampling,  Masaryk  University, RECETOX. RECETOX‐TOCOEN REPORT No.704, 2019.  https://www.recetox.muni.cz/en/services/recetox‐laboratories/environmental‐monitoring‐networks            RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  2    1. Sampler characterization    Passive air sampler consists of two stainless steel bowls attached to the common axes to form a protective  chamber for the polyurethane foam disk (PUF disk). The disk is attached to the same rod and it is sheltered  against the wet and dry atmospheric deposition, wind and UV light. The air flux is stabilized by the PUF  disk  positioning  as  well.  The  sampling  period  depends  on  type  and  concentration  level  of  measured  pollutants, it´s usually from 4 to 12 weeks.  PUF disks are made from non‐colored foam with defined thickness (1,5 cm) and diameter (15 cm), and  small hole in the middle. All disks are cleaned in Soxhlet extractors in set of solvents chosen according to  the group of pollutants that is targeted for sampling.   PUF  disk  extracted  in  acetone  and  dichloromethane  (DCM)  is  appropriate  for  the  analyses  of  organochlorinated  pesticides  (OCPs),  polychlorinated  biphenyls  (PCPs)  and  polybrominated  diphenyl  ethers (PBDEs).  PUF disk extracted in acetone and toluene is appropriate for the analyses of polychlorinated dibenzo‐p‐ dioxins (PCDD), dibenzofurans (PCDD/Fs) and dioxins‐like PCBs.  Finally, PUF disk extracted in acetone and methanol is aimed at capturing perflourinated compounds and  its precursors (PFCs).  Each disk with the metal insert is wrapped in two layers of aluminium foil. The date of cleaning and type  of cleaning (solvents like DCM, toluene or methanol) are noted on the package. The labeled wrapped PUF  disks are placed in a zip‐lock polyethylene bag, excess air is removed and bag is closed. Clean disks are  stored in a freezer at ‐18°C prior to deployment.    Scheme of the passive air sampler with PUF disk.          RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  3    The assembly order of passive air sampler is (from top to bottom):   Hanging hook – to hang the sampler   Nut and safety nut – to fix the upper bowl   Pad   Upper bowl with diameter 30 cm placed upside down – protection of PUF disk   Pad   Nut – to fasten the upper bowl   Distance tube (longer one) – to fix PUF disk in proper position below upper bowl   Pad   PUF disk with stainless steel insert (clean disk is prepared in the lab)   Pad   Distance tube (shorter one) – to fix the PUF disk position above lower bowl   Nut – to fix the distance tube before the lower bowl mounting   Pad   Lower bowl with diameter 24 cm placed bottom down – condensed water can drain through four  holes in the bottom of the bowl   Pad   Nut and safety nut – to fix the lower bowl position   Safety hook – it protects the sampler against the falling apart due to vibrations caused by the  strong wind, simultaneously enables to stabilize the sampler in a vertical position.                            RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  4    2. Sampler deployment – site selection   Passive air sampler is only hanged in vertical position with the bigger bowl up and placed ideally in the  man breathing zone 1,5 – 2 m above the ground (preferably grass). The metal construction is commonly  used for the sampler installation and open terrain location without significant obstacles for free air stream  around the sampler is optimal. Sampler should be installed on a background station which is not affected  by the direct sources of air pollution. Do not install the sampler close to the fire place, chimney or outlet  and outflow of measured pollutants. To prevent damage or sampler loss a secured place is required.                 Passive air sampler deployment.    The sampling site may be located centrally so as to obtain information on time trends of regional sources.  The site should avoid individual and large sources of pollutants so that they reflect a large area around the  site and not emissions from just a few local point sources. Requirements for such a site also include  geographic considerations and appropriately use already existing meteorological station. Site description  should follow a standardized approach and should be documented in a sampling protocol (see chapter 3).                  RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  5    3. Installation and changing of PUF disk   All sampling material is prepared before passive air sampler installation. There is a list of material which is  needed for PUF disk installation:   Passive air sampler – two bowls (one big and one small bowl), one threaded rod, six nuts, six pads,  two distance tubes (one big and one small tube), one safety hook [provided]   PUF disk [provided]   Sampling protocol [provided] and pen    Open‐end or ring spanner (17 mm)   Cooler box   Wash bottle with ethanol (alternatively hexane, acetone or isopropanol)   Paper tissue   Permanent marker   Aluminium foil   Disposable examination nitrile gloves (alternatively latex gloves)   Manual – Methodology of passive air sampling [provided].    Sampling material preparation    It is necessary to locate the sampling site with GPS coordinates (latitude and longitude) and altitude as  well as to take the pictures of sampler location during the first sampler installation. It is useful for the  sampler  deployment  to  prepare  the  metal  construction,  binding  wire  or  rope  for  before  the  first  installation.  The installation and PUF disk changing is only made with gloves according to the procedure below.            RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  6    3.1.PUF disk installation   1. The upper part mounting:   - two nuts are screwed on the top of threaded  rod,   - pad, upper bowl and pad are put on the rod,  - upper bowl is fasten with nut (to tighten use  the spanner).        2. Put the longer distance tube and pad on the  rod.        3. Remove  the  non‐exposed  PUF  disk  from  cooler box, unpack from polyethylene bag and  two layers of aluminium foil.                 RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  7    4. The unpacked PUF disk with metal tube insert  is  put  on  the  rod  using  aluminium  foil,  see  picture below.        5. Put the pad and shorter distance tube on the  rod.        6. PUF disk is fixed with nut (to tighten use the  spanner).                RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  8    7. Put the pad, lower bowl and pad on the rod.        8. Two nuts are used for the fixing of lower bowl  in  proper  position  (to  tighten  use  the  spanner).        9. Finally insert the safety hook to the small hole  in the rod.                RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  9    10.Place the passive air sampler with PUF disk on  the  prepared  metal  construction.  Use  the  hook on the top of the sampler and mount the  sampler on the construction with a climbing  carabine,  wire  or  rope.  If  there  is  no  metal  construction, use the wire or rope and fix the  sampler  on  an  unobstructed  tree  branch  about two meters above ground.        11.All  sampling  data  must  be  written  in  the  sampling  protocol  –  write  the  sample  code,  start  of  sampling,  site  description,  GPS  coordinates, weather conditions and possible  sampling influences.          3.2.PUF disk changing   Passive samplers should remains in the field for 3 months (84 days). Exposed PUF disks are removed by  reversing the installation steps.  12.Detach the passive air sampler from the metal  construction.  13.Remove the safety hook, nut, safety nut and  pad starting from bottom.  14.Carefully  remove  the  lower  bowl  without  contact with PUF disk.  15.Remove the pad and nut fixing the distance  tube.              RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  10      16.Carefully  remove  the  shorter  distance  tube  and the pad next to PUF disk.        17.  Using  aluminium  foil  remove  PUF  disk together with metal insert from the rod.          18.  Wrap  PUF  disk  into  two  layers  of  aluminium foil.                RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  11          19.PUF disk must be labeled using the permanent  marker with the sampling code according to  annex 1.         20.Place  PUF  disk  into  polyethylene  bag  (zip‐ lock), push out the air from bag and close it.                RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  12    21.Exposed  PUF  disk  is  transported  using  the  cooler box to the storage place.        22.Write all data including the end of sampling to  the sampling protocol.      23.It is necessary to check the passive air sampler  before  new  PUF  disk  installation.  Clean  the  sampler with ethanol and paper tissue.              24.The installation of non‐exposed PUF disk must  be realized according to the procedure which  is described in steps from 3 to 11.                  RECETOX, Masaryk University, Kamenice 753/5, pavilion A29, 625 00 Brno, Czech Republic  13    4. Transport and storage of PUF disk   All exposed PUF disks are transported to the storage place and stored in a freezer at ‐18°C until the  shipment or analyses of targeted analytes. The shipment of PUF disks is organized according to the  appended table. There is an information about number and type of samples, their coding and  responsible laboratory.