Report LightCycler® 480 Software . iiiiiiiiiii ^Roche) 02122014mecAkvantifikace Experiment Creation Date 12/2/2014 4:40:29 PM Last Modified Date 12/3/2014 10:52:39 AM Operator LMDM Owner LMDM Start Time 12/2/2014 4:50:05 PM End Time 12/2/2014 5:51:22 PM Run State Completed Software Version LCS480 1.5.1.62 Macro Macro Owner Macro Status Templates Plate ID 03413008 Test ID Lot ID Color Comp ID Run Notes Programs Program Name Stagel Cycles 1 Analysis Mode None Target (°C) Acquisition Mode Hold (hh:mm:ss) Ramp Rate (°C/s) Acquisitions (per °C) Sec Target (°C) Step size (°C) Step Delay (cycles) 50 None 00:00:02 4.40 0 0 0 Program Name Stage2 Cycles 1 Analysis Mode None Target (°C) Acquisition Mode Hold (hh:mm:ss) Ramp Rate (°C/s) Acquisitions (per °C) Sec Target (°C) Step size (°C) Step Delay (cycles) 95 None 00:05:00 4.40 0 0 0 Program Name Stage3 Cycles 40 Analysis Mode Quantification Target (°C) Acquisition Mode Hold (hh:mm:ss) Ramp Rate (°C/s) Acquisitions (per °C) Sec Target (°C) Step size (°C) Step Delay (cycles) 95 None 00:00:10 4.40 0 0 0 60 Single 00:00:30 2.20 0 0 0 Program Name Stage4 Cycles 1 Analysis Mode Melting Curves Target (°C) Acquisition Mode Hold (hh:mm:ss) Ramp Rate (°C/s) Acquisitions (per °C) Sec Target (°C) Step size (°C) Step Delay (cycles) 95 None 00:00:15 4.40 0 0 0 60 None 00:01:00 2.20 0 0 0 95 Continuous 0.11 5 0 0 0 02122014mecAk\«intifikace 12/3/2014 Page 1 of 8 Program Name cooling Cycles 1 Analysis Mode None Target Acquisition Hold Ramp Rate Acquisitions Sec Target Step size Step Delay (°C) Mode (hh:mm:ss) (°C/s) (per °C) (°C) (°C) (cycles) 40 None 00:00:01 2.20 0 0 0 Samples Sample Count Subset 96 All Samples Pos Name ID Repl. Of Sample Notes A1 JB ehr. DNA A1 A2 JB ehr. DNA A1 A3 JB ehr. DNA A1 A4 JB ehr. DNA A4 A5 JB ehr. DNA A4 A6 JB ehr. DNA A4 A7 JB ehr. DNA A7 A8 JB ehr. DNA A7 A9 JB ehr. DNA A7 A10 JB ehr. DNA A10 A11 JB ehr. DNA A10 A12 JB ehr. DNA A10 B1 JB ehr. DNA B1 B2 JB ehr. DNA B1 B3 JB ehr. DNA B1 B4 JB ehr. DNA B4 B5 JB ehr. DNA B4 B6 JB ehr. DNA B4 B7 JB ehr. DNA B7 B8 JB ehr. DNA B7 B9 JB ehr. DNA B7 B10 non template B10 B11 non template B10 B12 non template B10 C1 07/629 C1 C2 07/629 C1 C3 07/629 C1 C4 07/629redena C4 C5 07/629redena C4 C6 07/629redena C4 C7 07/759 C7 C8 07/759 C7 C9 07/759 C7 02122014mecAk\^ntifikace 12/3/2014 Page 2 of 8 Samples Sample Count] 96 Subset All Samples Pos Name ID Repl. Of Sample Notes C10 07/759redena C10 C11 07/759redena C10 C12 07/759redena C10 D1 Sample 37 D2 Sample 38 D3 Sample 39 D4 Sample 40 D5 Sample 41 D6 Sample 42 D7 Sample 43 D8 Sample 44 D9 Sample 45 D10 Sample 46 D11 Sample 47 D12 Sample 48 E1 Sample 49 E2 Sample 50 E3 Sample 51 E4 Sample 52 E5 Sample 53 E6 Sample 54 E7 Sample 55 E8 Sample 56 E9 Sample 57 E10 Sample 58 E11 Sample 59 E12 Sample 60 F1 Sample 61 F2 Sample 62 F3 Sample 63 F4 Sample 64 F5 Sample 65 F6 Sample 66 F7 Sample 67 F8 Sample 68 F9 Sample 69 F10 Sample 70 F11 Sample 71 F12 Sample 72 02122014mecAkvantifikace 12/3/2014 Page 3 of 8 Samples Sample Count] 96 Subset All Samples Pos Name ID Repl. Of Sample Notes G1 Sample 73 G2 Sample 74 G3 Sample 75 G4 Sample 76 G5 Sample 77 G6 Sample 78 G7 Sample 79 G8 Sample 80 G9 Sample 81 G10 Sample 82 G11 Sample 83 G12 Sample 84 H1 Sample 85 H2 Sample 86 H3 Sample 87 H4 Sample 88 H5 Sample 89 H6 Sample 90 H7 Sample 91 H8 Sample 92 H9 Sample 93 H10 Sample 94 H11 Sample 95 H12 Sample 96 Revision History Reusion Date User Reason Abs Quant/2nd Derivative Max for All Samples (Abs Quant/2nd Derivative Max) Settings Channel 465-510 Color Compensation Off Program Stage3 Units Mode High Confidence Subset Name All Samples > - Late Cp call (last five cycles) has higher uncertainty, E - Extrapolated concentration in standard curve 02122014mecAkvantifikace 12/3/2014 Page 4 of 8 Results Inc Pos Name Type CP Concentration Standard Status 0 A1 JB chr. DNA Standard 13.52 2.58E1 3.00E1 0 A2 JB chr. DNA Standard 13.71 2.29E1 3.00E1 0 A3 JB chr. DNA Standard 13.32 2.93E1 3.00E1 0 A4 JB chr. DNA Standard 16.63 3.52E0 3.00E0 0 A5 JB chr. DNA Standard 16.60 3.59E0 3.00E0 □ A6 JB chr. DNA Standard 3.00E0 0 A7 JB chr. DNA Standard 20.44 3.05E-1 3.00E-1 0 A8 JB chr. DNA Standard 31.37 2.76E-4 3.00E-1 0 A9 JB chr. DNA Standard 20.46 3.02E-1 3.00E-1 0 A10 JB chr. DNA Standard 23.89 3.33E-2 3.00E-2 0 A11 JB chr. DNA Standard 23.80 3.53E-2 3.00E-2 0 A12 JB chr. DNA Standard 24.21 2.71 E-2 3.00E-2 0 B1 JB chr. DNA Standard 27.87 2.60E-3 3.00E-3 0 B2 JB chr. DNA Standard 27.95 2.47E-3 3.00E-3 0 B3 JB chr. DNA Standard 28.00 2.39E-3 3.00E-3 0 B4 JB chr. DNA Standard 30.89 3.74E-4 3.00E-4 0 B5 JB chr. DNA Standard 31.13 3.20E-4 3.00E-4 0 B6 JB chr. DNA Standard 31.22 3.04E-4 3.00E-4 0 B7 JB chr. DNA Standard 31.93 1.93E-4 3.00E-5 0 B8 JB chr. DNA Standard 35.00 2.68E-5 3.00E-5 > 0 B9 JB chr. DNA Standard 35.00 2.68E-5 3.00E-5 > □ B10 non template Negate Control □ B11 non template Negate Control □ B12 non template Negate Control 0 C1 07/629 Unknown 10.14 2.27E2 E 0 C2 07/629 Unknown 11.48 9.56E1 E 0 C3 07/629 Unknown 11.36 1.04E2 E 0 C4 07/629redena Unknown 14.96 1.02E1 0 C5 07/629redena Unknown 15.17 8.96E0 0 C6 07/629redena Unknown 15.04 9.75E0 0 C7 07/759 Unknown 12.74 4.27E1 E 0 C8 07/759 Unknown 12.85 3.97E1 E 0 C9 07/759 Unknown 12.84 3.99E1 E 0 C10 07/759redena Unknown 16.20 4.63E0 0 C11 07/759redena Unknown 16.27 4.43E0 0 C12 07/759redena Unknown 16.29 4.36E0 0 D1 Sample 37 Unknown > - Late Cp call (last five cycles) has higher uncertainty, E - Extrapolated concentration in standard curve 02122014mecAkvantifikace 12/3/2014 Page 5 of 8 Results Inc Pos Name Type CP Concentration Standard Status 0 D2 Sample 38 Unknown 0 D3 Sample 39 Unknown 0 D4 Sample 40 Unknown 0 D5 Sample 41 Unknown 0 D6 Sample 42 Unknown 0 D7 Sample 43 Unknown 0 D8 Sample 44 Unknown 0 D9 Sample 45 Unknown 0 D10 Sample 46 Unknown 0 D11 Sample 47 Unknown 0 D12 Sample 48 Unknown 0 E1 Sample 49 Unknown 0 E2 Sample 50 Unknown 0 E3 Sample 51 Unknown 0 E4 Sample 52 Unknown 0 E5 Sample 53 Unknown 0 E6 Sample 54 Unknown 0 E7 Sample 55 Unknown 0 E8 Sample 56 Unknown 0 E9 Sample 57 Unknown 0 E10 Sample 58 Unknown 0 E11 Sample 59 Unknown 0 E12 Sample 60 Unknown 0 F1 Sample 61 Unknown 0 F2 Sample 62 Unknown 0 F3 Sample 63 Unknown 0 F4 Sample 64 Unknown 0 F5 Sample 65 Unknown 0 F6 Sample 66 Unknown 0 F7 Sample 67 Unknown 0 F8 Sample 68 Unknown 0 F9 Sample 69 Unknown 0 F10 Sample 70 Unknown 0 F11 Sample 71 Unknown 0 F12 Sample 72 Unknown 0 G1 Sample 73 Unknown 18.10 1.37E0 0 G2 Sample 74 Unknown > - Late Cp call (last five cycles) has higher uncertainty, E - Extrapolated concentration in standard curve 02122014mecAkvantifikace 12/3/2014 Page 6 of 8 Results Inc Pos Name Type CP Concentration Standard Status 0 G3 Sample 75 Unknown 0 G4 Sample 76 Unknown 0 G5 Sample 77 Unknown 0 G6 Sample 78 Unknown 0 G7 Sample 79 Unknown 0 G8 Sample 80 Unknown 0 G9 Sample 81 Unknown 0 G10 Sample 82 Unknown 0 G11 Sample 83 Unknown 0 G12 Sample 84 Unknown 0 H1 Sample 85 Unknown 0 H2 Sample 86 Unknown 0 H3 Sample 87 Unknown 0 H4 Sample 88 Unknown 0 H5 Sample 89 Unknown 0 H6 Sample 90 Unknown 0 H7 Sample 91 Unknown 0 H8 Sample 92 Unknown 0 H9 Sample 93 Unknown 0 H10 Sample 94 Unknown 0 H11 Sample 95 Unknown 0 H12 Sample 96 Unknown > - Late Cp call (last five cycles) has higher uncertainty, E - Extrapolated concentration in standard curve Statistics Samples Mean Cp Std Cp Mean cone Std cone A1, A2, A3 13.52 0.19 2.60E1 3.20E0 A4, A5 16.61 0.02 3.56E0 5.15E-2 A7, A8, A9 24.09 6.30 2.03E-1 1.75E-1 A10, A11, A12 23.97 0.22 3.19E-2 4.27E-3 B1, B2, B3 27.94 0.07 2.49E-3 1.09E-4 B4, B5, B6 31.08 0.17 3.33E-4 3.67E-5 B7, B8, B9 33.98 1.77 8.22E-5 9.58E-5 C1, C2, C3 10.99 0.74 1.42E2 7.34E1 C4, C5, C6 15.06 0.11 9.65E0 6.44E-1 C7, C8, C9 12.81 0.06 4.08E1 1.69E0 C10,C11,C12 16.25 0.05 4.47E0 1.37E-1 02122014mecAkvantifikace 12/3/2014 Page 7 of 8 Amplification Curves Standard Curve — Sttf. curve Samples Error: 0.0213 Efficiency: 1.899 Slope: -3.590 Ylntercept: 18.59 Link: 0.000 -2 -1.5 -1 Log Concentration 1.5 Analysis Notes 02122014mecAk\«intifikace 12/3/2014 Page 8 of 8