www.HidenAnalytical.com Hiden EQP Mass/Energy Analyser for Plasma Diagnostics and Characterisation www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science EQP Overview The Hiden EQP System is an advanced plasma diagnostic tool with combined high transmission ion energy analyser and quadrupole mass spectrometer, acquiring both mass spectra at specified ion energies and ion energy distributions of selected plasma ions. The advanced EQP ioniser provides for neutral and radical detection, the electron attachment ionisation feature further enhancing the detection capability for radicals in electronegative plasma chemistries. www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Features • Sub PPM detection of plasma ions, neutrals and radicals. • Ion Energy Analysis, 0-100eV and 0-1000eV energy range versions are available. • Positive and Negative Ion Analysis. • Neutral and Radical Species Detection. • Electron attachment ionisation mode for the study of electro-negative radicals • Mass range options: 50, 300, 510 or 1000 amu • For afterglow, pulsed plasma, and laser ablation, a standard TTL signal gating input is included for time resolved studies. www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Applications EQP Systems are offered with a range of standard plasma sampling options to provide a non invasive sampling interface for a broad range of plasma applications including: • ECR- Electron Cyclotron Resonance • HIPIMS • Magnetron Discharge • Helicon Source • DC Glow Discharge Plasma • Pulsed Plasma & Laser Ablation • Parallel Plate - RF Plasma • ICP- Inductively Coupled Plasma www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science EQP System Schematic www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Typical Operating Configuration Plasma Typically 100 mTorr Mass Spectrometer Typically 1 x 10-7 Torr 60 l.min-1 Turbo Pump Sampling Orifice 100 µm www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Laser Drilled Orifice • User selected dimension from 30 - 300 m. • +ve / -ve ions, neutrals or radicals. • Pre-thinned for optimum sampling. • Plasma electrode coupling option – allows the user to configure the orifice to exactly follow electrode conditions during operation. www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science • Software controlled and optimised extraction and focussing optics. • Discriminates +ve and –ve ions as well as e- and radicals. • Fully tuneable for optimal detection. • Integrated ionisation source. Extraction Optics www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Ionisation Source • Fully software controllable electron energy (0-150 eV) and thermionic emission (0.2-2000 µA). • Electron Impact, Appearance Potential, Soft Ionisation modes allow for powerful characterisation of the neutral and radical species from the plasma.ccl2f2 plasma off -on -off. 18mTorr chamber preasure. SEM:c/s electron-energy : V 1 10 100 1000 5 9.16667 13.3333 17.5 21.6667 25.8333 30 ccl2f2 plasma off -on-off. 18mTorr chamber preasure. SEM:c/s electron-energy : V 1 10 100 1000 5 9.16667 13.3333 17.5 21.6667 25.8333 30 Plasma off Plasma on www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Ion Source Control 10 100 1000 10000 -2-10 1 2 3 4 5 6 7 8 910111213141516171819 C/S energy / eV 1 10 100 1000 10000 0 5 10 15 20 25 30 35 40 45 50 55 electron energy : V Intensity:c/s Plasma On Electron Energy Scans Plasma On/Off comparison of the production of CF2 ions. Energy Scan of Fast Neutrals Cu Atom Energy Distribution from a DC magnetron discharge. Plasma Off e + CF4  CF2 + + F2 + 2e (19.3eV) e + CF4  CF2 + + 2F +2e (20.9eV) www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science 45° Electrostatic Sector Energy Analyser • Constant transmission at all ion energies. • Minimum perturbation of ion flight path. • Energy resolution - 0.25 eV FWHM. • Energy scan at increments from 0.05 eV. • Floating option available up to 10 KeV. 0 50000 100000 150000 200000 250000 300000 350000 400000 450000 500000 0 5 10 15 20SEMC/S ION ENERGY EV www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science • Strict control over the quadrupole entrance and exit fields provides enhanced sensitivity for high mass transmission and increased abundance sensitivity. • Enhanced long-term stability. The bulk of the deselected ions from the ioniser deposit harmlessly on the RF-only pre-filter stage, minimising contamination on the mass selective primary filter. Triple Filter Mass Spectrometer www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Quadrupole Diameter • Configured with 6mm or 9mm What pole diameter do I need? • Total RF output power is fixed for a given generator. • Power demand increases dramatically with increasing RF frequency: (∝ ν5) • For given mass, performance improves with increasing frequency. • For given tolerances, transmission and mass separation improve with increasing pole diameter. • Overall size and cost increase with increasing pole diameter. • Enlarging pole diameter increases assembly capacitance and limits RF range (increases power losses). 50/300/510 amu 50/300/510/1000/2500 amu 6mm 9mm www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science • 7 decade continuous dynamic range. • 24 bit counter for 1 c/s resolution. • Faraday Cup option for high density plasmas. • Signal gating with 50 ns time resolution for energy & mass distributions. • Comprehensive data export options. Secondary Electron Multiplier (SEM) Detector www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science • Signal gating input with 0.1 µs resolution is standard. • Enhanced signal gating modes including programmable signal gating and MCS are available as system options or upgrades. • Programmable signal gating includes foreground and background delay timers to monitor two time zones with respect to a relative repeated event. Programmable Signal Gating Features: • 0.1 µs minimum gate delay and width. • Automatic background subtraction for modulated molecular beam studies. • Ion flight time measurements. www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science • Optional innovative Multi-Channel Scalar (MCS) device integrated into controller firmware and MASsoft v7 software. • 6000-bin multichannel scalar resolution offering 50 ns time resolution. • Data is intuitive to obtain and can be manipulated in external programmes such as Excel and Origin. Multi-Channel Scalar (MCS) Device Suitable for transient event analysis applications such as: • Beam chopper inlets. • Plasma ignition/modulation/extinction experiments. • Ion flight time measurements. www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science • Analysis through: - viewport - grounded electrode - driven electrode • High pressure plasmas with double differential pumping. • Magnetically confined plasmas with optional Mu-metal & radio-metal shielding. • Analysis of high mass (1000 amu). • Analysis of high energy (1000 eV). Configuration Options www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science 1000 amu EQP with z drive EQP with RF driven electrode Configuration Options www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Clamping ring Driven Electrode Extractor nozzle Electrode support body Driven Electrode Controllable Orifice Cover Configuration Options www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science MASsoft 7 Professional control software A multilevel software package allowing both simple control of mass spectrometer parameters and complex manipulation of data plus control of external devices. www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Selected Publications • Latest publications • Negative-ion surface production in hydrogen plasmas: modelling of negativeion energy distribution functions and comparison with experiments. 2013. A Ahmad et al. Plasma Sources Sci. Technol. 22 025006 • Spacially enhanced Langmuir probe measurements of a magnetically enhanced hollow cathode arc plasma. 2011. B Zimmermann et al. Surface and coatings technology 205 5393-5396 • Quantification of the deuterium ion fluxes from a plasma source. 2011. A Manhard et al. Plasma Sources Sci. Technol. 20 015010 • Advantages of highly ionized pulse plasma magnetron sputtering of silver for improved E. coli inactivation. 2012. O Baghriche et al. Thin Solid Films 520 3567- 3573 • Influence of high power impulse magnetron sputtering plasma ionization on the microstructure of TiN thin films. 2011. AP Ehiasarian. J. Appl. Phys. 109 104314 www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Selected Hiden EQP Users • Xi’an Modern Chemistry Institute • University d’Orleans • Southwest Research Institute • KRICT • INP Greifswald • Applied Materials • Fraunhofer IWS • Ruhr-Universität Bochum www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science • High performance probe for mass and energy analysis of ions, radicals and neutrals from a plasma. • A large number of options are available in order to sample from a variety of plasma types. • The EQP sees use worldwide in a variety of plasma applications. 0 100000 200000 300000 400000 500000 0 5 10 15 20 SEMc/s Ion Energy eV Summary www.HidenAnalytical.com Quadrupole Mass Spectrometers for Advanced Science Hiden Analytical Ltd. 420 Europa Boulevard Warrington, WA5 7UN, England HidenAnalytical.com info@hiden.co.uk Tel: +44 (0)1925 445 225