PřF:C9072 Analysis by ICP-MS - Course Information
C9072 Analysis of solid and liquid samles by ICP-MS
Faculty of ScienceAutumn 2016
- Extent and Intensity
- 2/0/0. 2 credit(s) (fasci plus compl plus > 4). Type of Completion: zk (examination).
- Teacher(s)
- Mgr. Michaela Vašinová Galiová, Ph.D. (lecturer)
- Guaranteed by
- prof. RNDr. Viktor Kanický, DrSc.
Department of Chemistry – Chemistry Section – Faculty of Science
Supplier department: Department of Chemistry – Chemistry Section – Faculty of Science - Prerequisites
- Knowledge of General Chemistry
- Course Enrolment Limitations
- The course is also offered to the students of the fields other than those the course is directly associated with.
- fields of study / plans the course is directly associated with
- Analytical Chemistry (programme PřF, N-CH)
- Inorganic Chemistry (programme PřF, N-CH)
- Physical Chemistry (programme PřF, N-CH)
- Environmental Chemistry (programme PřF, N-CH)
- Organic Chemistry (programme PřF, N-CH)
- Course objectives
- The aim of the course is to prepare students to apply theoretical knowledge and practical experience in their own scientific and research work.
- Syllabus
- • ICP-MS fundamentals, Operation and performance of ICP-MS, SW, HW, Instrument adjustment and performance for solution analysis, instrument routine maintenance, data acquisition, error messages and troubleshooting, logbook. • Operation and performance of LA (213 nm, 193 nm), basics of LA operation, SW, HW, connecting of LA with ICP-MS in various combinations of ICP-MS and LA, sample preparation and positioning in ablation chamber, spot and raster analysis, line scan analysis. • Method creation for solution analysis, importance and implementation of internal reference/standard, spectral interferences, their detection, evaluation and correction/minimization, collision\reaction cell tuning, PN-ICP-MS calibration, preparation of standard/sample solutions, blank solution. • Method creation for LA-ICP-MS, adjustment and optimization of LA-ICP-MS, calibration using synthetic reference materials, data acquisition and treatment at spot analysis, quantification, internal standard application, fractionation. • Elemental mapping with LA-ICP-MS, data acquisition and treatment at grid of points and line-scan. • Examples of practical methods.
- Literature
- VAŠINOVÁ GALIOVÁ, Michaela, Viktor KANICKÝ and Jan HAVLIŠ. Laser ablation inductively coupled plasma mass spectrometry as a toll in biological sciences. In Vladimír Havliček; Jaroslav Spížek. Natural Products Analysis: Instrumentation, Methods, and Applications. New Jersey: Wiley, 2014, p. 313-348. ISBN 978-1-118-46661-2. Available from: https://dx.doi.org/10.1002/9781118876015.ch9. URL info
- BECKER, Johanna Sabine. Inorganic mass spectrometry : principles and applications. Chichester: John Wiley & Sons, 2007, xx, 496. ISBN 9780470012000. info
- Teaching methods
- Theory and practice
- Assessment methods
- Theory and practice examination
- Language of instruction
- Czech
- Further Comments
- The course is taught annually.
The course is taught: every week.
- Enrolment Statistics (recent)
- Permalink: https://is.muni.cz/course/sci/autumn2016/C9072